Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹4.6 L+₹6,777.50 (1.49%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹4.6 L+₹7,275 (1.60%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S UK MECH AND ELECT ENGG WORKS L3 | R M ENTERPRISES L2 | M/S ISHAN ELECTRICAL and MECH. ENGG. WORKS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Repair of 105 TR capacity water cooled Air conditioning chiller Plant No II installed at Plant room of GMCH, Jammu by way of disconnecting of electrical connections and holding the water supply by closing the butterfly valves of the inlet and outlet chiller pipelines. The job includes removing the 105 TR screw compressor from it installed position by removing all the connected gas/oil pipeline connections to it and loading it on mechanical transport by manual means and sending to designated workshop for dismantling and repairs. The job includes replacement of complete bearing inside compressor -11 No’s set in screw compressor along with replacement of gasket set -14 No’s. The job also includes replacement of Piston ring- 05 No’s set and also replacement of 02 No’s filters inside the compressor. The job includes filling of fresh Polyolester compressor oil- 25 ltrs. Then assembling the screw compressor and sending to site i.e main plant Room of GMCH Jammu for installation. Installing the compressor on its original position and Then recharging the plant with fresh refrigerant gas R-407- 150 Kg and opening the butterfly valves to circulate water and then making all the electrical connections testing of chillar plant on no load and on full load. Complete job includes cost of materiai, labour, transportation and all types of taxes etc. | 1 | job | 0.01 ₹4,62,675 | 0.01 ₹4,62,177.5 | 0.01 ₹4,55,400 Lowest |
Tender Value
₹4.7 L
EMD Value
₹10,000
Closing Date
13 Jun 2026, 4:00 pmClosed
XEN MH DIVISION GMCH JAMMU
XEN MH DIVISION GMCH JAMMU
Repair of 105 TR capacity water cooled Air conditioning chiller Plant No II installed at Plant room of GMCH, Jammu.
2026_PWDJK_311647_1
MHDJ/e-NIT 64 of 2026-27
Open Tender
Repair and Maintenance Services
Turn-key
10 days
GMCH
as per e nit
2 documents required · 2 mandatory
₹200
XEN MH DIVISION GMCH JAMMU
₹10,000
10 Jul 2026
5 Jun 2026
15 Jun 2026
5 Jun 2026
13 Jun 2026
8 Jun 2026
5 Jun 2026 - 13 Jun 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division GMCH Jammu.
XEN MH DIVISION GMCH JAMMU
MHDJ/e-NIT 64 of 2026-27 Dated: 05.06.2026 Due : 13.06.2026
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate including GST to be quoted by the bidder Rs. P Currency Convertion against each Item Quoted Currency in INR / Other Currency Rebate on old parts in Percentage (%) if any Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Net Cost of item Rs. P
1 Repair of 105 TR capacity water cooled Air conditioning chiller Plant No II installed at Plant room of GMCH, Jammu by way of disconnecting of electrical connections and holding the water supply by closing the butterfly valves of the inlet and outlet chiller pipelines. The job includes removing the 105 TR screw compressor from it installed position by removing all the connected gas/oil pipeline connections to it and loading it on mechanical transport by manual means and sending to designated workshop for dismantling and repairs. The job includes replacement of complete bearing inside compressor -11 No’s set in screw compressor along with replacement of gasket set -14 No’s. The job also includes replacement of Piston ring- 05 No’s set and also replacement of 02 No’s filters inside the compressor. The job includes filling of fresh Polyolester compressor oil- 25 ltrs. Then assembling the screw compressor and sending to site i.e main plant Room of GMCH Jammu for installation. Installing the compressor on its original position and Then recharging the plant with fresh refrigerant gas R-407- 150 Kg and opening the butterfly valves to circulate water and then making all the electrical connections testing of chillar plant on no load and on full load. Complete job includes cost of materiai, labour, transportation and all types of taxes etc. 1 job Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
BOQ_1009050.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .