Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC 37 CENTRAL ROAD AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | ₹1.2 Cr | L1 | Accepted-AOC selected as L1 bidder |
| 2 | L2₹1.2 Cr+₹6.2 L (5.23%)Rejected-AOC JAGAHARIMURA AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | ₹1.2 Cr+₹6.2 L (5.23%) | L2 | Rejected-AOC Not selected as the bidder rate is higher |
Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
5 Sept 2023, 9:00 amClosed
DGM ED Sabroom
DGM ED Sabroom
Electrification of Special economic Zone Jalefa Sabroom South Tripura
2023_POWER_41230_1
DNIT/dgm/ED-sbm/23-24/01 Dated 12.05.2023
Open Tender
Electrical Works
Turn-key
180 days
DGM ED Sabroom
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
Yes
₹2.1 L
Yes
19 Oct 2023
25 Aug 2023
6 Sept 2023
25 Aug 2023
5 Sept 2023
25 Aug 2023
25 Aug 2023 - 4 Sept 2023
Amount
9.0 mtr long galvenised steel tubular pole(SP-32)
11 mtr. long galvenised Steel Tubular pole(SP-57)
Stay set complete
A.C.S.R. conductor (Rabbit 50 sq mm)
G.I. strainded wire (Stay wire)
Strain insulator ( H.T).
11 KV Disc insulator
11 KV disc fittings
11 KV Pin insulator with GI pin
Galvanised Channel (75x40x40x6 mm)
Galvanised Angle (65x65x6 mm)
11 KV G.O. Switch
11 KV D.O.Fuse Set
2.5 mtr. long 40 mm dia. G.I. pipe for earthig of O.H. cable termination point
8 SWG G.I. wire (4 mm) for earth connectivity
¾ th inch dia. Polythin Pipe
Cement Concreting of Steel pole
Erection of 1 (one) no. RCC piler base of size 1.5x2.0x0.75 mtr including supply of all materials
120 sqmm bi- metalic lugs
Galvanised Bkt. Clamp (50x6 mm)
Galvanised Stay Clamp (50x6 mm)
Galvanised Nuts & Bolts (assorted size)
Erection of 9.0 mtr long galvenised steel tubular pole
Erection of 11 mtr. long galvenised Steel Tubular pole
Erection of Stay set complete
Erection of A.C.S.R. conductor (Rabbit 50 sq mm)
Erection of G.I. strainded wire (Stay wire)
Erection of Strain insulator ( H.T).
Erection of 11 KV Disc insulator
Erection of 11 KV disc fittings
Erection of 11 KV Pin insulator with GI pin
Erection of Galvanised M.S. Channel (75x40x40x6 mm)
Erection of Galvanised M.S. Angle (65x65x6 mm)
Erection of 11 KV G.O.. Set
Erection of 11 KV L.A.
Erection of 11 KV D.O.Fuse Set
Excavation, erection, testing & commissioning of 40mm dia, 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover plates on GI frame, charcoal, salt and other accessories complete.
Erection of 8 SWG G.I. wire (4 mm) for earth connectivity
Erection of ¾ th inch dia. Polythin Pipe
Erection of 1 (one) no. RCC piler base of size 1.5x2.0x0.75 mtr including supply of all materials
Erection of 120 sqmm bi- metalic lugs
Erection of Galvanised Bkt. Clamp (50x6 mm)
Erection of Galvanised Stay Clamp (50x6 mm)
Supplying of 11 KV U.G.,240 sq. mm. 3C, TR-XLPE insulated conductor and insulation screened Aluminium conductor Power cable as per IS : 7098/II/1985 ans latest amendments incl. taxes , duties,freight & insurance etc as per technical spec of the Bid document.
Outdoor type Heat Shrink Jointing kit suitable for 240 sq. mm. 3XC, XLPE UG cable
Indoor type heat shrink cable jointing kit size of 240 sqmm 3XC, XLPE UG cable.
Supply of HT kiosk/11 Kv outdoor type feeder piller made of 10SWG MS sheet complete with aluminium busbar, HT insulator etc sa required provided with Rocking System with ID marking with G special UG line and panting to be fitted on structure of M S Angle(65x65x6mm) and flat(50X6 mm) as required and concreting of ratio 1:2:4(0.054cum/leg) with excavation of earth centering shuttering & disposal of excess soil.
9.0 mtr long galvenised steel tubular pole
Galvanised Stay set complete
Stay Insulator (HT)
Stander Stay Wire
11 KV G.O.. Set
11 KV Pin Insulator with GI Pin
11 KV Danger Board
Galvanised 75x40x40x6 mm M.S. Channel
Galvanised M.S. Angle (65x65x6 mm)
GI Bkt. Clamp (50x6 mm)
GI Stay Clamp (50x6 mm)
GI Nuts & bolts of assorted size
2.5 mtr. long 40 mm dia. G.I. pipe for earthig of O.H. cable termination point
8 SWG G.I. wire (4 mm) for earth connectivity
¾ th inch dia. Polythin Pipe
100 mm. dia. TATA/JINDAL/ BANSAL make best quality G.I. pipe as per IS:1239 (as per price list)
Supply of 11 KV,800 Amps continuos rated current, 350 MVA rupturing capacity Indoor Vaccum Circuit Breaker ( for outgoing feeder), complete with 1 set of CT of ratio 200/1.5 Control & Relay Pannel Simplex type with 110 Volt DC actuated electrical closing/ tripping mechanism and internal wiring , 2-Over current & 1-earth fault combined micom digital relay, 1 no electromechanical AREVA Master Trip Realy auxiliary relays as required, 1 no. L& T / SECURE make "Tri-Vector" Meter (SCADA compatible), 3 Ammeter, 1 Voltmeter, 1 C.T opareted static KW meter, with panel bus mounted C.T and integal earthing facility including inemal arc tested panel Conforming to relevant ISS/IEC as reqd. including standard indication facilities as per reqirment detyailed herein after.
Supply of 11 kv Ring Main Unit : 12 KV motorrised ringmain unit, self power typewith CPT or by other means, solid or SF6 installation, outdoor enclouser, FPI, battery and charging system, software, all accessories and tools as provided in technical specification 3 way RMU Type SBBBSS.
Laying & commisioning of 3XC, 240 Sqmm, 6.35/11KV, XLPE insulated armoured HT power cable direct into earth including excavation of earth up-to a depth of 1100 mm (Width of the trench 40 cm) including 1st class brick protection of two layer flat brick soling, 300 mm. sand (river sand) cushoning and refilling and ramming the excavated soil and also make devider by layig of bricks to protect both the cables as per direction of the EIC.
Erection of HT kiosk/11 Kv outdoor type feeder piller made of 10SWG MS sheet complete with aluminium busbar, HT insulator etc sa required provided with Rocking System with ID marking with G special UG line and panting to be fitted on structure of M S Angle(65x65x6mm) and flat(50X6 mm) as required and concreting of ratio 1:2:4(0.054cum/leg) with excavation of earth centering shuttering & disposal of excess soil.
Fitting, fixing of outdoor type Heat Shrink Jointing kit suitable for 240 sq. mm. 3XC, XLPE UG cable
Earth work in excavation in foundation trenches not exceeding 1.2m in depth. On plan or drains not exceeding 0.5 width . On plan including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil.
Filling in plinth with sand under floors including watering, ramming , consolidating and dressing complete.
Fitting, fixing of Indoor type heat shrink cable jointing kit size of 240 sqmm 3XC, XLPE UG cable.
Erection of 9.0 mtr long galvenised steel tubular pole
Erection of Stay set complete
Erection of Stay Insulator (HT)
Erection of Stander Stay Wire
Erection of 11 KV G.O.. Set
Erection of 11 KV Pin Insulator with GI Pin
Erection of Galvenised 75x40x40x6 mm M.S. Channel
Erection of Galvenised M.S. Angle (65x65x6 mm)
Erection of Galvanised Bkt. Clamp (50x6 mm)
Erection of Galvanised Stay Clamp (50x6 mm)
Excavation, erection, testing & commissioning of 40mm dia, 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover plates on GI frame, charcoal, salt and other accessories complete.
Erection of 8 SWG G.I. wire (4 mm) for earth connectivity
Laying of 100 mm. dia. TATA/JINDAL/ BANSAL make best quality G.I. pipe as per IS:1239 (as per price list)
Erection of 11 KV,800 Amps continuos rated current, 350 MVA rupturing capacity Indoor Vaccum Circuit Breaker ( for outgoing feeder), complete with 1 set of CT of ratio 200/1.5 Control & Relay Pannel Simplex type with 110 Volt DC actuated electrical closing/ tripping mechanism and internal wiring , 2-Over current & 1-earth fault combined micom digital relay, 1 no electromechanical AREVA Master Trip Realy auxiliary relays as required, 1 no. L& T / SECURE make "Tri-Vector" Meter (SCADA compatible), 3 Ammeter, 1 Voltmeter, 1 C.T opareted static KW meter, with panel bus mounted C.T and integal earthing facility including inemal arc tested panel Conforming to relevant ISS/IEC as reqd. including standard indication facilities as per reqirment detyailed herein after.
Cable identification marker: Providing of pre-cast cement concrete cable identification route marker (1 cement: 2 sand : 4 graded stone aggregrate 6 mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement morter 1:3 (1 cement: 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker shall be embossed " DANGERS: TSECL, 11KV Power cable" with black colour letter (Both side). The vissible part shall be painted with yellow colour Japan Paint.
Erection, testing & commissioning of 11 kv Ring Main Unit : 12 KV motorrised ringmain unit, self power typewith CPT or by other means, solid or SF6 installation, outdoor enclouser, FPI, battery and charging system, software, all accessories and tools as provided in technical specification 3 way RMU Type SBBBSS with appropriate civil work.
KAJAL DAS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .