Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC | L1 | Accepted-AOC Agreement executed | |
| 2 | L2₹10.6 L+₹2,198 (0.21%)Rejected-AOC 25 P NO 310 | L2 | Rejected-AOC Second lowest valid tender |
Tender Value
Refer Docs
EMD Value
₹26,396
Closing Date
30 Sept 2023, 6:00 pmClosed
Assistant Executive Engineer
O/o the Assistant Executive Engineer, PWD Electrical Sub Division, Kozhikode
Rehabilitation of C H Fly over in Kozhikode district-Providing Street Lights - General Electrical Work
2023_PWD_605913_1
PWD/BLDG/TR/15729/2023
Open Tender
Electrical Works
Item Rate
120 days
Kozhikode
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,760
₹26,396
12 Oct 2023
23 Sept 2023
3 Oct 2023
23 Sept 2023
30 Sept 2023
23 Sept 2023
Amount
SITC of Street Lights
OD117086/2023-2024:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III single arm bracket one meter including junction box etc. complete 8 Meters
90.15.3.7:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 8 Meters
OD113301/2023-2024:Supply of 120w(+/-3w) LED Streetlight with minimum 16,800 Lumens light output in 5700K CCT, Greater than 140 Lumens per watt system efficacy using high power LED having minimum 75,000 burning hours as per L70. The driver shall have 140-270 Operating voltage range and 440V withstand capacity for min 8 hours. THD <10% and Power factor 0.95. The housing shall be made of LM6 grade single piece pressure diecast aluminium housing having 500hours NSS salt spray tested finish and Polycarbonate cover made using injection moulding with lens to achieve IP66 with IK10 Protection. The luminaire and Driver shall be seperately BIS Approved of same brand equivalent of Philips BRP503 LED168 CW R3C PSU S1 SPD or Techno commercial equivalent
OD117088/2023-2024:Supply and fixing of Threaded rod foundation bolt 4nos of 8.8 Grade M20 size in 600mm length using chemical anchoring vertically on the footpath. The bolt shall be anchored minimum 10cm inside main concrete and through top slab including 2 nuts washers equivalent to HIlti Threaded rod AM20x3000 8.8 Zinced + Injectable Motar HIT-RE 500 V4/500
OD117557/2023-2024:Steel reinforcement for RCC Work including straightening, cutting, bending, placing in position and binding all complete.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD117237/2023-2024:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to structure using clamps, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.50 mm dia
90.12.5.39:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
OD117814/2023-2024:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench 40/32 mm or nearest size
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
OD117819/2023-2024:Supplying and fixing 40A, four pole, 415 volts, 2way centre OFF MCB type Change Over Switch in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.7:Supply and providing copper earth bus in the panel board
OD117089/2023-2024:Supply, fabrication, conveyance and fixing the GI clamps made from using 32 mm X 6 mm GI strip bent to shape and fixing the same as per the instruction from the Engineer in charge.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD117687/2023-2024:Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
OD117688/2023-2024:Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD117002/2023-2024:Supply and providing 25x6mm brass nut and bolt etc. as required
OD117003/2023-2024:Supply and providing 25x3mm brass nut and bolt etc. as required
2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
OD117021/2023-2024:Supply and fixing 32A Fuse base with HRC fuse link in the existing meter board and giving connections etc.
OD117022/2023-2024:Supply and fixing 32A, 2 way neutral link mounted on DMC/ SMC base in the existing box and giving connections etc. as required
OD117486/2023-2024:Supplying and fixing 25A 4 Pole AC-1 contactor complete with connections, testing and commissioning etc. as required. (L&T make AC-1 contactor cat no MCX 02 or Techno Commercial equivalent approved by engineer in charge)
OD117487/2023-2024:Supplying and fixing 24Hours Digital Time Switch for operating ON-OFF function in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. (L&T make Digital Time switch 2 module cat no 67DDT0 or Techno Commercial equivalent approved by engineer in charge)
OD117024/2023-2024:Supply and fixing 4 pole porcelain terminal connector
OD117043/2023-2024:Supply and fixing Danger notice board of size, 125 x 75 mm
1.21.4:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
SHAJI P
Bidder Name
SHAJI P
BHOOPESH T K
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_903240.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .