| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.7 LAccepted-AOC RAILWAY COLONY NOWGAM SRINAGAR JAMMU AND KASHMIR 190015 | BUDGAM | JAMMU AND KASHMIR | 190015 | ₹41.7 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹43.3 L+₹1.6 L (3.82%)Rejected-AOC | ₹43.3 L+₹1.6 L (3.82%) | L2 | Rejected-AOC Other than Lowest |
| 3 | L3₹44.1 L+₹2.4 L (5.74%)Rejected-AOC | ₹44.1 L+₹2.4 L (5.74%) | L3 | Rejected-AOC Other than Lowest |
| 4 | L4₹44.7 L+₹3.1 L (7.34%)Rejected-AOC FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | ₹44.7 L+₹3.1 L (7.34%) | L4 | Rejected-AOC Other than Lowest |
| 5 | L5₹46.4 L+₹4.7 L (11.3%)Rejected-AOC | ₹46.4 L+₹4.7 L (11.3%) | L5 | Rejected-AOC Other than Lowest |
Tender Value
₹47.1 L
EMD Value
₹94,120
Closing Date
30 Jan 2024, 6:00 pmClosed
GE 969 EWS
GE 969 EWS C/O 56 APO
SPL REPAIR TO OVERHEAD LT CONDUCTOR BY CONVERSION TO UG CABLE AT NAUGAM,PROVN OF 02 X DEEP FREEZER WITH 02 X STABILIZER AND SPECIAL REPAIR TO INTERNAL ROAD AT BARAMULLA UNDER GE 969 EWS
2024_MES_635384_1
CA NO 969 WS - /2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 969 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹94,120
Yes
29 Feb 2024
2 Jan 2024
1 Feb 2024
2 Jan 2024
30 Jan 2024
16 Jan 2024
Amount
Dismantling of ACSR or AAC conductor from pole of any size and capacity complete all as specified and as directed.
Taking down of old unsv UG cable from trench of any size and capacity, complete all as specified and as directed.
Excavation in trenches in soft loose soil including cutting road surfaces n. exc 1.5 mtrs wide and n.exc 1.5 mtr in deep for foundation of poles, stays, cables pipe etc and getting out all as specified and as directed.
Returning filling in, of excavated soil in trenches incl spreading levelling, watering and well ramming in layers each layers n. exc 25cm thick in soft/loose soil, complete all as specified and as directed.
Removal surplus soil to a distance n. exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above the starting point, complete all as specified and as directed.
Supply and spread river sand to required width at bottom and top for cable cushioning all as specified in clause 19.75 of SSR Part-I (Note : thickness of sand will be measured after punning)
Supply and lay common burnt bricks of sub class B old size laid at right angle on the cable complete in trenches for cable protection complete all as specified and as directed.
Supply, laying, jointing and testing LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts grade conforming to IS-1554 laid in trenches, pole, road crossing walls, floor etc cross sectional area of 150 Sqmm 3.5 core complete all as specified and as directed.
Supply, laying, jointing and testing LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts grade conforming to IS-1554 laid in trenches, pole, road crossing walls, floor etc cross sectional area of 70 Sqmm 3.5 core complete all as specified and as directed.
Supply, laying, jointing and testing LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts grade conforming to IS-1554 laid in trenches, pole, road crossing walls, floor etc cross sectional area of 50 Sqmm 3.5 core complete all as specified and as directed.
Supply, laying, jointing and testing LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts grade conforming to IS-1554 laid in trenches, pole, road crossing walls, floor etc cross sectional area of 25 Sqmm 3.5 core complete all as specified and as directed.
Supply, laying, jointing and testing LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts grade conforming to IS-1554 laid in trenches, pole, road crossing walls, floor etc cross sectional area of 16 Sqmm 4 core complete all as specified and as directed.
Supply, laying, jointing and testing LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts grade conforming to IS-1554 laid in trenches, pole, road crossing walls, floor etc cross sectional area of 10 Sqmm 2 core complete all as specified and as directed.
S&F galvanised Iron Tubing 40mm dia 'light grade complete with fitting for protection of cable with the pole, complete all as specified and as directed.
S&F house service bracket, hook type complete with 3.0 M long Gl pipe 50mm dia medium grade two Nos 90 degree bend MS hook and stay guy complete all as specified and as directed.
M&L Scraping, cleaning and preparation of surface of steel pole for painting with the help of sand paper, wire brush and cotton cloth and applying externally with two coats of synthetic enamelled paint as zebra strip type from ground level to 1.5 mtr height and aluminium paint from 1.5 mtr height to top plug level over a coat of red oxide primer and numbering of poles complete all as specified and as directed.
S&F for junction box of size 250x250x160mm made of Sintex SMC/FRP Nos MCBs 06 amps incl magnetic lock system all as required and fixed to poles using MS strip of size 32x6mm and nuts & bolts of required size all as required at site or as directed.
S&F multistranded twin Core copper conductor (flexible) FR PVC insulated industrial Cables (Unsheathed) 2.5 Sqmm 1100 volts Conforming to IS:694 complete all as specified and as directed.
Supply, Installing & testing and commissioning in replacement of factory made tested (incl CPRI type test certified) LT panel board cubical out door type of size 0.75 x 0.75 x 0.40 mtrs, plate mounted suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bar 400 Amps rating installed on porcelain/ SMC insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 40 x 40 x 6 mm thick MS angle iron frame work, powder coated finish over one coat of red oxide out side surface and painted in side with two coats of red oxide primer and rear opening type with apran for cable entry closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked, 1100 volts grade of appropriate size (but not less than 4.0 Sqmm) and comprimising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform for suitable size etc all as deviated with the following fitments:- (a) MCCB 4 pole 415 volt 250 amp rating bracking capacity 36 KA Incoming (Adjustable Overload 40-100 %). (b) Bus bar : Providing suitable size of Bus bar of aluminium 400 amp rating with coloured heat shrinkable insulated sleeves 415 volts as per IS of suitable size mounted on DMC/epoxy insulator
Material and labour for earthing complete with galvanised steel earth plate electrode of size 600x 600x 6mm thick, burried directly in ground (earth pit not less than 2.2 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to earth strip of size 32x6 mm earth lead by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 50mm bore (medium grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1 (using 20mm graded agg) and pre-cast RCC cover slab of size 540x540x50mm thick with rain forced with 8mm dia deformed bars both ways and one handle for lifing made with 10mm dia mild steel bar, funrel, wire mesh 20mm bore galvanised (medium grade) for watering, charcoal and salt in alternate layers including neccessary execution and earth works in any types of soil complete all as shown on Electrical plate no 3 of MES Schedule Part I including taking out materials from existing on complete all as specified and as directed.
Dismantling / disconnecting and taking down insulaters of any size & capacity, complete all as specified and as directed.
Dismantling of cross arms and MS chanel or angle section etc complete all as specified and as directed.
S&F High efficient LED street light of 35 W Capacity with lens made of pressure dia cast aluminium housing, extruded aluminium heat sink & enclosed with toughened glass, IP 66 protection suitable for high mast light fitting with all necessary accessories complete all as specified and as directed.
S&F double pole Isolator 40 Amp complete all as specified and as directed.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, size of 10 Sqmm one twin core cable flat or circular complete all as specified and as directed.
M&L steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 metres long) complete all as specified and as directed.
M&L for repairs to surfaces of macadam roads by scarifying or picking gravelled macadam or bituminous macadam surfaces in area exc 400 Sqm and exc 50 mm and n. exc 100mm deep, complete all as specified and as directed.
Rolling and consolidation formation in cutting with roller using 8 to 12 Ton power roller complete to required level, gradient, slope, camber, super elevation including filling depression and including approved earth which may occur during rolling process all as specified and as directed.
M&L for soling (or sub base) 100mm thick compacted thickness with broken boulders or quarried stone, interstices filled, surface formed and rolled and consolidated to required gradient and chamber with 8 to 12 tonne power roller complete all as specified and as directed.
M&L 150mm thick cement concrete 1:4:8, D-2 using (40mm graded aggregate) in sub base floor, paving and hard standing, complete all as specified and as directed.
M&L cement concrete work in pavement/ hardstanding of flexural strength 40 Kg per Sqcm in field using 400 Kg of cement per cum thickness of concrete 25cm or less, complete all as specified and as directed.
Formwork to edges of concrete flats, threads, bricks in floors, opening in concrete walls, floor and roofs n.exc 200mm wide and sides of RCC/PCC bend in walls, horizontal or sloping and similar work exc 10cm but n.exc 20cm wide,complete all as specified and as directed.
M&L forming 12mm thick expansion joints for 150mm thick concrete, filled with pre-formed bituminious filler and top 30mm primed and sealed with sealing compound, Grade `A', complete all as specified and as directed.
M&L forming contraction (dummy) joints 65mm deep x 10m wide, filled with sealing compound `A' Grade, complete all as specified and as directed.
Forming construction joint 150mm deep x 10mm wide filled with sealing compound, complete all as specified and as directed.
M&L moorum/red bajri filling in floors or pavings, laid in layers n.exc 15cm thick, spread, levelled and rammed including watering,complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified and as directed.
S&F Deep Freezer Hard Top 600 Ltrs capacity having triple door non convertible body material metal with wheel on base dimensions 1915 x 665 x 860 mm.
S&F Voltage stabilizer copper wound for automatic operation, single phase naturally air cooled indoor type & desgined for input variation between 70V to 250V with output voltage stabilized at 230 V with accuracy of ± 2.5 % and of capacity 5 KVA specially suitable for deep freezer.
Note:- Schedule of credit Rs. 66,955.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
Kesar Impex
m/s mohd saleem and co
VEDA INFRASTRUCTURE
Javeed And Co
M/s BEECO CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .