| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L1 | Accepted-AOC AOC | |
| 2 | L2₹45.2 L+₹14.5 L (47.1%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
5 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NO GE(N)AMB-54(P)/2020-21 PROVN OF CERTAIN SANCTIONED WORKS IN SECTOR B UNDER AGE E/M NORTH OF GE (N) AMBALA CANTT
2020_MES_358134_1
GE(N)Amb-54(P)/2020-21
Open Tender
Civil Works
Item Rate
182 days
GE (NORTH) AMBALA CANTT
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹86,000
Yes
26 Oct 2020
28 Aug 2020
7 Oct 2020
28 Aug 2020
5 Oct 2020
21 Sept 2020
29 Aug 2020 - 13 Sept 2020
60 days
Amount
M&L for sub main wiring with two run of 6sqmm, PVC insulated, unsheathed copper conductor (FRLS-H), multistranded copper conductor, 1100 volts grade ISI marked with one run of 6 sq mm, PVC insulated, unsheathed copper conductor (FRLS-H), multistranded copper conductor as earth contuinity wire and including provision of non metalic PVC conduit of size 25mm dia ISI marked medium grade concealed on wall surfaces and on surface on ceiling surfaces including all Tees,Bends,elbow,reducer,bell mouth tube ends,fixing accessories such as couplers ,bolts nuts,saddles,pipe hooks,all fittings/labours fixed on walls/ceiling & making good to disturbed surfce of wall and ceiling complete all as specified and as directed by Engineer-in-Charge. Note: Two runs of 6 sqmm cable and one run of 6sqmm cable with PVC conduit shall be measured as one length/Unit.
Supply & Fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 'C'series complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix stop valves 15mm bore, cast copper alloy, chromium plated , screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix stop valves 20mm bore, cast copper alloy, chromium plated , screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix GI tubes 20mm dia medium grade galvanised with all fittings and fixtures, fixed concealed to walls/ ceilings/floor as required at site and making smooth the disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix GI tubes 15mm dia medium grade galvanised with all fittings and fixtures, fixed concealed to walls/ ceilings/floor as required at site and making smooth the disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix Water heater (Geyser) storage type electric of capacity 25 Ltrs , BEE 5Star rated, ABS body, metal tank with glasss lined coating, multiple heating option, shock safe plug, puf insulation, incoloy glass coated anode rod / copper heating element of capacity 2KW with ISI mark , adjustable knob for temp setting with minimum 8 Bar high working pressure, multi functional safety valve & whirl/Swirl flow technology, thermostat electronic type, thermal cutout capillary type complete including superior quality copper connection pipe heavy duty 15mm dia 450mm long, brass adopter for water connection with nikhel coated ISI marked with fastner, nut bolts, washers duly grouted, giving shape to hole as suitable and plastering including making good of disturbed surface as per existing surface, connecting to inlet and outlet valves, testing complete all as specified and as directed by Engineer-in-Charge. Note :- Warranty certifcate to be produced by the Contractor from OEM for the following components before processing the bill. a) for Product - 02 Years b) for Heating element - 03 Years c) for metal tank - 07 Years
Supply and fix MCB single pole 240 volt 6 to 40 amps 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix Chromium plated Brass wall mixer, external fixed type for hot and cold water supply including required fixtures and fittings suitable for 15mm bore pipe complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster / Tiling including removal of rubbish to a distance not exc 50m and M&L Glazed tiles ceramic 7mm thick, 1st quality of size exc 0.11 sqm but not exc. 0.18 sqm as in scirting/dado, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including a layer of screed bed of 10mm thick, CM 1:4 including making smooth the disturbed surface and removing waste and cleaning thouroughly complete all as specified and as directed by Engineer-in-Charge.
Taking down existing GI tubing 15/20mm concealed/surfaceas per existing complete all as specified and as directed by Engineer-in-Charge.
S & Laying sub main wiring with two run of 10 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volt grade ISI marked with multi stranded copper conductor with one run of 10 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor connected to common earth dolly including provision of non metalic PVC conduit of size 25mm dia ISI marked medium grade concealed on wall surfaces and on surface on ceiling surfaces including all tees,bends,elbow,reducer,bell mouth tube ends,fixing accessories such as couplers ,bolts nuts,saddles,pipe hooks,all fittings/labours fixed on walls/ ceiling & making good to disturbed surfce of wall and ceiling complete all as specified and as directed by Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Two runs of 10 sqmm cable and one run of 10 sqmm cable with PVC conduit shall be measured as one length/Unit.
Supply and laying XLPE insulated, armoured heavy duty electric cable 25 sqmm cross sectional area, 4 core with aluminium conductor, 1100 volts grade complete all as specified and as directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cables. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L for sand cushoning under the cable for protecting the cable being damaged from external load complete all as specified and as directed by Engineer-in-Charge. Note: punned thickness shall be measured for payment.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed by Engineer-in-Charge.
S&F light grade GI Tubing of size 40mm dia for cable protection and fixed with clamp to pole and wall with nut bolts complete all as specified and as directed by Engineer-in-Charge
Taking down unserviceable MCB DB alongwith MCCBs/MCBs and MCB DB plug & Socket Boards alongwith MCBs of any description and making good the disturbed surfaces of walls and paint tuch up to match with existing finishes as per site requirement complete all as specified and as directed by Engineer-in-Charge..
S&F MCCB DB vertical type 4 way doubble door load line, IP43, powder coated complete alongwith 200 Amp rated Bus bar three pole and neutral with acrylic door fixed on wall enclosed in out door type sheet metal enclosure of 2.15 mm thick complete all as specified and as directed by Engineer-in-Charge.
Supply and fix sheet metal enclosure single pole & neutral for 240 volts, 12 way, IP43 with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and as directed by Engineer-in-Charge.
Supply and Fix MCCB 4 pole, 63 Amp, 415 Volts 16 KA, ISI Marked fixed type including fixing arrangement complete all as specified and as directed by Engineer-in-Charge.
supply and fix over and Low voltage release 1 module, 230 volts AC, suitable for single phase adjustabe from 170 volts to 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix RCBO 40 Amps 2 Module 100 MA (HI immunity) sensitivity 230 volts 50 Hz ISI marked complete all as specified and as directed by Engineer-in-Charge.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth lead of 4mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls/floors/ceiling, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for One Tube light point controled by one way switch, complete all as specified and as directed by Engineer-in-Charge.. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket and fan regulators to be measured and paid for separately .
All as per item No. 1.28 but for One fan point controled by one way switch, complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 1.28 but for One Bld security light point controled by one way switch, complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 1.28 but for One 3 pin 5 Amps socket point controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 1.28 but for One 3 pin 5 Amps socket point controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description All as per item No. 1.28 here-in-before but with 2.5 Sqmm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, 0neway 16 Amps 240 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular socket 16 Amps 2 module 2/5, pin type, complete all as specified and as directed by Engineer-in-Charge.
Description All as per item No. 1.28 here-in-before but with 4 Sqmm for metal clad box point controlled by one switch on independent board and 4.00 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular switch 1 module,single pole,one way 5/6 Amps 240 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket out let2/3 pin 6amp 240 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix including LED Bulb, pin type, 12 watt, energy efficient complete all as specified and as directed by Engineer-in-Charge.
Taking down fan any type / descripition , after disconnecting the all electrical connection carefully, transport to the market and dismantling of blades, M & L scraping to old paint ,cleaning and washing with washing powder water including filling cavities with filler and marking as exsitng for painting to ceiling fan by using synthetic supper enamel paint in two coats by spray, hanging the ceiling fan as exsiting fan point and making all electrical connection using 3 core copper flexible cable drawn through in PVC flexible conduit pipe, testing complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular fan regulator, 2 module electronic step type (socket type) , 120 watt,230volts,50 Hz, AC supply suitable for celling fan any type/make/sweep complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing inreplacment for celling rod for celling fan made out of GI pipe, medium grade 20mm dia of length 1.00 metreincluding fan clamps with rubber reel for hanging ofceiling fans, complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix of TV sockets outlets ISI marked complete all as specified and as directed by Engineer-in-Charge.
M & L for rigid non metalic 20 mm PVC conduit exclusive of boxes but inclusive of all bends,elbows and mouth tube ends and fixing such as couplers, lock nuts ,saddles and pipe hooks etc for passing TV cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Bell buzzer electric , SP ding dong type, 230V, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED street light 40/45watt 230 volts 50 Hz including bracket made up of 1.60m long GI pipe, 25mm dia light grade, bent to required length and fixed to wall with two clamps made of 40x6 mm mild steel flat iron 15cm long, 4 Nos 8mm dia bolts with nuts and connecting with 3 core copper conductor flexible cable from terminal box to the ceiling rose or connector of the light point including two coats of synthetic enmel paint over a coat of red oxid primer on mild steel surfaces complete all as specified and as directed by Engineer-in-Charge.
S&F Decorative mirrior light fitting EZEE DELUXE compact energy efficient luminaire with anti-glare diffuser and electronic ballast suitable for 2X11 watt, 230V with all accessoies such as copper ballasts, capacitors, spring loaded rotor type lamp holders, starter holder, starter, connector block etc incl lamp and all accessories pre wired upto terminal block including connecting with 3 core copper conductor flexible cable from terminal box to the ceiling rose or connector of the light point complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix in replacement ultra slim decorative recess mounted LED 36 Watt square 580mmx580mm celling cut out light fitting,height 30mm high efficency diffuser watt 240 volts, 6000K, 50HZ,AC supply,complete all accessiories internally per wired including connecting with 3 core copper conductor flexible cable of size 23/0.0076 from celling rose to connector of the light complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement Batten suitable for LED tube light fitting 1x19 Watt AC 220-240 Volts, 50 Hz and including LED tube rod 1x19 Watt connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for earthing pit display boards made out of 3mm thick MS sheet of size 30 x 35cm welded to 75cm long 25 x 25 x 5 mm thick MS angle iron grouted in PCC 1:3:6(with 20mm stone aggregate) to a depth of 20 cm and applying two coats of synthetic enamel paint of approved color over a coat of red oxide primer and writing the letters on plate for showing the following details: 1. EARTHING PIT NO. : 2. DATE OF MEASUREMENT : 3. NEXT DUE DATE : 4. STANDARD VALUE : 5. VALUE OBTAINED : 6. MEASURED BY : 7. SUPERVISED BY :
M & L for earthing complete with Copper earth plate electrode 600 x 600 cm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to copper strip size 20x 3mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth strip protected by 25mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed including taking down unserviceable earthing. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Arneja Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .