Loading…
Loading…
Tender Value
₹3.8 Cr
EMD Value
₹7.6 L
Closing Date
7 Apr 2026, 3:00 pmClosed
BTPN examination facilities for TRL-2 for a length of 150M as per CAMTECH guide lines and other facilities at CSL/VSKP in the section of SSE/W/MPM/WAT under jurisdiction of ADEN/Estate/WAT.
eT-HQ-WAT-13-2026~ECOR
eT-HQ-WAT-13-2026
Open
Works - General
8 Months
Visakhapatnam, Andhra Pradesh
₹0
₹7.6 L
7 Apr 2026
10 Mar 2026
24 Mar 2026
E-FR Items - Structural Drawing items 2541854.19 Below/P
Item Breakup - A-CPWD DSR-2023 Items
Item Breakup - B-Steel Reinforcement items
Item Breakup - C-Structural steel items
Item Breakup - D-FR Items
Soil Exploration, preparation of Architectural Sqm Plans, Elevations, Structural Designs, Drawings including proof check etc,
Preparation of Architectural drawings for Sqm parking, Entrance Plazza in front of Building and Landscaping for surrounding area. Total 78520.74
Item Breakup - E-FR Items - Structural Drawing items
Ground water investigations charges with Each testing Engineer and required machinery, equipment etc., at required location complete with all contractor's labour tools & plant, lead, lift, loading, unloading, transportation, royalty and other incidental charges etc., as directed by the Engineer-in- charge of the work. WALTAIR DIVISION-ENGINEERING/ECOR
Yield test for Bore well 300 mm dia Each including hiring of 1 HP submersible pump with required accessories and hiring of 6 KV Generator for 24 hours including diesel etc., and hiring of joint kit for fixing motor such as Tapes, Shallk, Rubber, Reducers, nipples etc., and hiring of garden hose pipe, 200 ltrs capacity drums and other misc.item required for measuring of water and fixing of pump and motor including electrical panel etc., and the same will be removed after 24 hours continuous test etc., with all contractor's labour, tools & plant, lead, lift, loading, unloading, royalty and all other incidental charges complete as directed by the Engineer-in- charge of the work at site.
Boring / Drilling of deep tube well of Metre required dia (Upto 300 mm) by suitable method of fixing casing/Strainer pipe in all kinds of soils including rock / boulder strate collecting samples from different strata for preparation of strata chart / bor log including hire & running charges of all equipment, tools and plants, machineries required fo rht ejob, lead lift transport charges, GST and other incidental charges all complete as per direction of Engineer in charge.Drillig of bore well upto 30Mts depth
Boring / Drilling of deep tube well of Metre required dia (Upto 300 mm) by suitable method of fixing casing/Strainer pipe in all kinds of soils including rock / boulder strate collecting samples from different strata for preparation of strata chart / bor log including hire & running charges of all equipment, tools and plants, machineries required fo rht ejob, lead lift transport charges, GST and other incidental charges all complete as per direction of Engineer in charge.Drilling of borewell above 30 Mts depth to upto 60Mts
Boring / Drilling of deep tube well of Metre required dia (Upto 300 mm) by suitable method of fixing casing/Strainer pipe in all kinds of soils including rock / boulder strate collecting samples from different strata for preparation of strata chart / bor log including hire & running charges of all equipment, tools and plants, machineries required fo rht ejob, lead lift transport charges, GST and other incidental charges all complete as per direction of Engineer in charge.Drilling of borewell above 60 Mts depth to upto 90Mts
Supply, assembling, lowering and fixing in Metre vertical position in bore well, unplasticized PVC medium bore well casing pipe of reuired dia and depth and make of TRUBORE includig hire and labour charges, Fittings, accessories, tools, plants, Transportatino, lead, lift, GST and other incidental charges all complete as per direction of Engineer in charge. PVC Borewell casing pipe of 225mm nominal dia and working pressure of 4Kg/Cm2 WALTAIR DIVISION-ENGINEERING/ECOR
Supply, assembling, lowering and fixing in Metre vertical position in bore well, unplasticized PVC medium bore well casing pipe of reuired dia and depth and make of TRUBORE includig hire and labour charges, Fittings, accessories, tools, plants, Transportatino, lead, lift, GST and other incidental charges all complete as per direction of Engineer in charge. PVC Borewell casing pipe of 180mm nominal dia and working pressure of 6Kg/Cm2
Perforation /Slotting charges to PVC borewell Metre casing pipe of any dia including labour charges, tools, plants, lead , lift and other incidental charges all complete as per direction of Engineer in chargeNote: PVC Casing pipe to be paid extra.
Supply and fixing of 1.1/2 inch dia HDPE Metre suction pipe for 300 mm dia bore well with all contractor's labour, tools & plant, lead, lift, loading, unloading, transportation, royalty and all other incidental charges complete, as directed by engineer-in-charge of the work at site.
Supply and fixing of 1.1/2 inch dia of 2 nos Each SS Nipple for HDPE pipe, 1.1/2 inch dia 1 no bore cap to cover the ore outer dia, PVC double screen and Plumbing joints kit for providing the jointing area to assemble the pump ( Tapes, shellac, joints, rubber, reducers, Hose clamps, Hose nozzles etc.,) for HDPE suction pipe for 300 mm dia bore w e l l with all contractor's labour, tools & plant, lead, lift, loading, unloading, Trancporting, royalty etc., and all other incidental charges complete, as directed by engineer-in-charge of the work at site.
Erection, installations etc of Tube well. ** The unit LS to be read as LUMPSUM). Total 2541854.19
Item Breakup - F-Electrical items
Pumps and Electrical arrangement for Set overhead water Tank of Cap 60000 Liters & Electrification of Pump House - (A) Supply, Erection, Testing and Commissioning of Submersible pump set, motor rating 5HP capacity, minimum 3 star rated suitable for 415 volts, 50 Hz, 3 phase AC supply, Make: Lubi or KSB or similar with suitable microprocessor based digital type DOL Starter Panel with Digital ammeter, voltmeter, Dry run protection, on/off push botton, single phase preventer, Make: ABB, L&T, C&S, Schnieder, Havells, Siemens :----- The price shall covers the cost of Supply, Erection, Testing and Commissioning of Submersible pump set, motor rating 5HP capacity, minimum 3 star rated suitable for 415 volts, 50 Hz, 3 phase AC supply, Make: Lubi or KSB or similar with suitable microprocessor based digital type DOL Starter Panel with Digital ammeter, voltmeter, Dry run protection, on/off push button, single phase preventer, Make: ABB, L&T, C&S, Schnieder, Havells, Siemens. The price shall cover the cost of all materials required for the above work including labour charges.
Laying of Cable in open air - The unit price Metre shall cover for fixing of the cable on plinth/structure/column/culvert to be done by GI Clamp of suitable size as per site requirement. The distance of each clamp should not be more than 1 meter. The work should be completed with contractors' materials, tools & plants etc.
Supply, erection, testing and commissioning Numbers of 20W 1150mm LED batten fitting - The rate inclusive of, fixing, testing and commissioning of indoor LED fitting at site as per site requirement and as per instructions of site in charge, complete in all respects, with contractors material, labour, tools and plants etc. (LED fittings will be supplied by Railways)
erection, testing and commissioning of BLDC Numbers Ceiling fan 1200mm sweep with regulator (remote controller) - The price also covers the cost of erection, testing and commissioning of BLDC Ceiling fan 1200mm sweep with regulator (remote controller) The rate inclusive of fixing, testing and commissioning of fan at site as per site requirement and as per instructions of site in charge, complete with contractors material, labour, tools and plants etc. Fans will be supplied by Railways. WALTAIR DIVISION-ENGINEERING/ECOR
PVC concealed wiring of light/fan/call bell Point point with (2x1.5+1x1) sq.mm FRLSH PVC insulated flexible copper wire (Modular Type) - Supply of materials, testing & commissioning with single core FRLS PVC insulated multi stranded copper conductor of size 1.5 sq. mm 1100V grade confirming to IS 694/1990 each for phase & neutral and 1.0 Sq.mm FRLS PVC insulated copper wire for earth continuity conductor. The rate includes concealed wiring of light/Ceiling fan/Exhaust Fan/Air circulator in any type of wall complete with supply of materials, testing & commissioning with single core FRLS PVC insulated multi stranded copper conductor of size 1.5 sq. mm (1100V grade) each for phase & neutral and 1.0 Sq.mm FRLS PVC insulated copper wire for earth continuity conductor drawn inside suitable size of PVC pipe of 2mm thick. The wiring shall be in Loop method where the phase/Live wire shall be looped at Switch and Neutral only. No joints shall be allowed. In case of angular lamp holder it should be fixed properly on 4"x4" size GI box concealed in the wall. In case of FL light point and fan point, connection is to be terminated in a Poly carbonate three terminal ceiling rose fixed on top of the suitable size GI box fixed inside the wall / ceiling. The control shall be of 6 amps 250V grade modular type switch shall be supplied and fixed by contractor on suitable size of GI flush box to accommodate number of switches in that sub circuit and as decided by the site in-charge with modular cover plate. The cost includes fixing of the board with required material and fasteners etc. on the wall. The location of the board shall be decided by the site in charge. The number of switches in the Switch board will depend on number of points in that sub circuit or as decided by the site in-charge. The cost of wiring point includes supply of Fasteners, PVC Sleeves, Elbow, Tee of appropriate size of PVC conduit pipe, flush box, cover other items required for completion of work with contractor manpower and material and as directed by site in charge. The cost also includes connection of wires on both sides. The price also covers groove cutting in the wall and makes it the original position cement plastering with contractor's labour, materials and tools as directives of engineer in-charge at site. WALTAIR DIVISION-ENGINEERING/ECOR
PVC concealed wiring of 6A socket point Point with (2x2.5+1x1) sq.mm FRLSH PVC insulated flexible copper wire (Modular Type) for separate point - The rate includes concealed wiring of 6A capacity socket point in any type of wall, complete with supply of materials, testing & commissioning with single core FRLS PVC insulated multi stranded copper conductor of size 2.5 sq. mm 1100V grade confirming to IS: 694/1990 each for phase & neutral and 1.0 Sq.mm FRLS PVC insulated copper wire for earth continuity conductor. drawn inside PVC conduit pipe 19/25 mm size of 2mm thick. The circuit shall be drawn from sub service main for both Phase and Neutral and shall be terminated on the socket. Wiring to be done in loop in and loop out method or as per direction of site incharge. No joints shall be allowed. The control switch and socket shall be of 6 amps capacity pin socket modular type and fitted on the metal flush box with modular cover plate. The cost includes fixing of the board with required material and fasteners etc. on the wall. The location of the board shall be decided by the site in charge. The cost of wiring point includes supply of Fasteners, PVC Sleeves, Elbow, Tee of appropriate size of PVC conduit pipe, and other items required for completion of work with contractor manpower and material and as directed by site in charge. The cost also includes connection of wires on both sides, Fixing of socket, switch and making connection with three wires (Phase, Neutral & Earth). The price also covers groove cutting in the wall and makes it in the original position cement plastering with contractor's labour, materials and tools as directives of engineer incharge at site. The Specifications and makes are given in the Annexure WALTAIR DIVISION-ENGINEERING/ECOR
PVC concealed wiring of 16A socket point Point with (2x4+1x1.5) sq.mm FRLSH PVC insulated flexible copper wire (Modular Type) - The rate includes concealed wiring of 16A capacity socket point in any type of wall, complete with supply of materials, testing & commissioning with single core FRLS PVC insulated multi stranded copper conductor of size 4 sq. mm 1100V grade confirming to IS: 694/1990 each for phase & neutral and 2.5 Sq.mm FRLS PVC insulated copper wire for earth continuity conductor. drawn inside PVC conduit pipe 19/25 mm size of 2mm thick. The circuit shall be drawn from sub service main for both Phase and Neutral and shall be terminated on the socket. Wiring to be done in loop in and loop out method or as per direction of site incharge. No joints shall be allowed. The control switch and socket shall be of 16 amps capacity 6 pin socket modular type and fitted on the metal flush box with modular cover plate. The cost includes fixing of the board with required material and fasteners etc. on the wall. The location of the board shall be decided by the site in charge. The cost of wiring point includes supply of Fasteners, PVC Sleeves, Elbow, Tee of appropriate size of PVC conduit pipe, and other items required for completion of work with contractor manpower and material and as directed by site in charge. The cost also includes connection of wires on both sides, Fixing of socket, switch and making connection with three wires (Phase, Neutral & Earth). The price also covers groove cutting in the wall and makes it in the original position cement plastering with contractor's labour, materials and tools as directives of engineer incharge at site. The Specifications and makes are given in the Annexure.
PVC concealed sub-sub main wiring with Running (2x4+1x1.5) sq.mm FRLSH PVC insulated Metre flexible copper wire (Sub-main wiring with Phase, Neutral & Earth) - The rate includes PVC Pipe wiring of concealed wiring from distribution board to the sub distribution board or for AC point in any type of wall, complete with supply of materials, testing & commissioning with single core PVC FRLS insulated multi stranded copper conductor of size 4 sq mm 1100V grade confirming to IS: 694/19902 wire. The copper conductor shall drawn inside of suitable size of PVC Pipe. 1.5 sq mm copper wire is to be drawn as earth wire. 1 meter length consists of two wires of 4 sqmm and one wire of 1.5sqmm (Phase, Neutral Earth). The price also covers groove cutting in the wall and makes it in the original position cement plastering with contractor's labour, materials and tools as directives of engineer incharge at site. The makes and specifications are shown in Annexure WALTAIR DIVISION-ENGINEERING/ECOR
PVC concealed wiring with (2x6+1x2.5) Running sq.mm FRLSH PVC insulated flexible copper Metre wire (Sub-main wiring with Phase, Neutral & Earth) - The rate includes PVC Pipe wiring of concealed wiring from distribution board to the sub distribution board or for AC point in any type of wall, complete with supply of materials, testing & commissioning with single core PVC FRLS insulated multi stranded copper conductor of size 6 sq mm 1100V grade confirming to IS: 694/19902 wire. The copper conductor shall drawn inside of suitable size of PVC Pipe. 2.5 sq mm copper wire is to be drawn as earth wire. 1 meter length consists of two wires of 6 sqmm and one wire of 2.5sqmm (Phase, Neutral Earth). The price also covers groove cutting in the wall and makes it in the original position cement plastering with contractor's labour, materials and tools as directives of engineer incharge at site. The makes and specifications are shown in Annexure.
PVC concealed sub-sub main wiring with Running (2x2.5+1x1) Sq.mm FRLSH PVC insulated Metre flexible copper wire (Sub-main wiring with Phase, Neutral & Earth) - The rate includes concealed wiring of sub main wiring from Sub distribution board to the Switch board complete with supply of materials, testing & commissioning with single core FRLS PVC insulated multi stranded copper conductor of size of 2.5 sq mm 1100V grade for phase and neutral. The wiring shall be drawn inside of suitable size of PVC pipe with 2mm thick Connection is to be tapped off from the distribution board. 1.0 sq. mm FRLS PVC insulated copper conductor is to be drawn as earth wire.. 1 meter length consists of two wires of 2.5sqmm and one wire of 1.0 sqmm (Phase, Neutral Earth).The price also covers groove cutting in the wall and makes it in the original position cement plastering with contractor's labour, materials and tools as directives of engineer incharge at site. The makes and specifications are shown in Annexure. WALTAIR DIVISION-ENGINEERING/ECOR
Provision for modular wiring on board 6A Numbers plug point with 2.5 sq.mm. copper wire - The rate includes concealed wiring of 6A capacity socket point in any type of wall, complete with supply of materials, testing & commissioning with single core FRLS PVC insulated multi stranded copper conductor of size 2.5 sq. mm 1100V grade confirming to IS: 694/1990 each for phase & neutral and 1.0 Sq.mm FRLS PVC insulated copper wire for earth continuity conductor drawn inside suitable size PVC conduit pipe of suitable size of 2mm thick. The circuit shall be drawn from sub service main/nearest Switch board for phase and neutral and shall be terminated on the socket. The concealed wiring shall be in loop in loop out method. No joints shall be allowed. The control switch and socket shall be of 6 amps capacity 5 pin socket modular type fitted on the separate metal flush box with modular cover plate. The cost includes fixing of the board with required material and fasteners etc. on the wall. The location of the board shall be decided by the site in charge. The cost of wiring point includes supply of Fasteners, PVC Sleeves, Elbow, Tee of appropriate size of PVC conduit pipe, and other items required for completion of work with contractor manpower and material and as directed by site in charge. The cost also includes connection of wires on both sides. The cost also include, Fixing of socket, switch and making connection with three wires (Phase, Neutral & Earth). The price also covers groove cutting in the wall and makes it in the original position cement plastering as directives of engineer incharge at site.
Supply, erection, testing and commissioning Numbers of 12-way Main DB Double door along with IC-63A MCB TPN, O/G -32A SP MCB-4No., 16A SP MCB-4No. of 10KA C-Curve - The rate shall include the cost of Supply, erection, testing and commissioning of 12-way Main DB Double door along with IC-63A MCB TPN, O/G -32A SP MCB-4No., 16A SP MCB-4No. of 10KA C-Curve..The price shall cover the cost of all materials required for the above work including labour charges. Before supply of materials, contractor has to take approval from Sr.DEE(G)/WAT or his authorized official. The make and specifications are shown in Annexure.
Supply, erection, testing and commissioning Numbers of 45W LED street light in SST/GRP pole/ GI octagonal pole/ bldg/ structure - The price also covers the cost of Supply, erection, testing and commissioning of 45W LED street light in SST/GRP pole/ GI octagonal pole/ bldg/ structure. [Price includes supply & installation etc. of fittings on ceiling with required hardware and fasteners and making electrical connection to make the light functional but except point wiring] The price shall cover the cost of all materials required for the above work including labour charges. Before supply of materials, contractor has to take approval from Sr.DEE(G)/WAT or his authorized official. WALTAIR DIVISION-ENGINEERING/ECOR
Supply, erection, testing and commissioning Numbers All-in-one of Solar Steet Light System 25W LED, IP:65 or better, Power output of PV module: >/=75Wp, LiFeP04 Battery capacity >/= 12.8V (nominal), 30 Ah, provided with 2 LED indicators for chaning in progress, deep discharge condition, 7m height pole, nominal bore size/thickness: 65mm/4.5mm, battery box: battery included in the luminaire enclosure and corrosion resistant, with solar PV modules with efficacy >/=75Wp at 16.4+/-0.2 V at STC, necessary control electronics, interconnecting wires/cables, module mounting structures etc. to operate from dusk to dawn etc. as per other conditions in specification similar to model No. Havells 7. Price also include cost of concrete foundation, erection of lighting sytem with grouting bolt etc. for commissioning of the entire system - The price also covers the cost of Supply, erection, testing and commissioning of Solar Street Light System 25W LED, IP:65 or better, Power output of PV module: >/=75Wp, LiFeP04 Battery capacity >/= 12.8V (nominal), 30 Ah, provided with 2 LED indicators for changing in progress, deep discharge condition, 7m height pole, nominal bore size/thickness: 65mm/4.5mm, battery box: battery included in the luminaire enclosure and corrosion resistant, with solar PV modules with efficacy >/=75Wp at 16.4+/-0.2 V at STC, necessary control electronics, interconnecting wires/cables, module mounting structures etc. to operate from dusk to dawn etc. as per other conditions in specification similar to model No. Havells 7. Price also include cost of concrete foundation, erection of lighting system with grouting bolt etc. for commissioning of the entire system. The price shall cover cost of excavation of earth pit in any kind of soil/rock for erection of pole with cement concrete in the ratio 1:3:6 casting of foundation including re-filling and dressing of earth with contractor's labour, tools including supply of cement and all materials. Digging of pit, casting of foundation 0.8Mx0.8Mx1M/ 1Mx1Mx2M with stone ballast of size 40mm/20mm and below for erection of with contractor's cement and mortar with ratio 1:3:6 and 12mm. thick cement plastering and neat cement finishing are also to be done for muffing by the contractor. All the foundations are to be cured for 21 days. The price shall cover the cost of all materials required for the above work including labour charges. Price also include cost of concrete foundation, erection of lighting sytem with grouting bolt etc. for commissioning of the entire system. Before supply of materials, contractor has to take approval from Sr.DEE(G)/WAT or his authorized official. The makes and specifications are shown in Annexure. WALTAIR DIVISION-ENGINEERING/ECOR
(B) : Power supply arrangement to ETP Plant Numbers etc., 12Nos. Welding Sockets for TRL-2 at an interval of 15M and other associated yard illumination works - Supply, Erection, Testing and Commissioning of out door feeder pillar consisting of copper bus bar 400Amp for RYB & N with LED type indication lamp for RYB in incoming side in a CRCA sheet with double door provision & locking arrangement. The panel shall consist of I/C:1X250A MCCB 4P Ics 35KA with 250/5A CTs, out going:4x100A MCCB 4P Ics 25KA, 1x63A MCB DP, 7x32A MCB DP, 10KA, Timer with contactor, size: 700mmX900mmX350mm approx, sheet :1.6mm thick, Angle :40x40x6mm,Channel:75X40mm (For MCCB'sIcs=100% Icu) - The price also covers the cost of Supply, Erection, Testing and Commissioning of out door feeder pillar consisting of copper bus bar 400Amp for RYB & N with LED type indication lamp for RYB in incoming side in a CRCA sheet with double door provision & locking arrangement. The panel shall consist of I/C:1X250A MCCB 4P Ics 35KA with 250/5A CTs, out going:4x100A MCCB 4P Ics 25KA, 1x63A MCB DP, 7x32A MCB DP, 10KA, Timer with contactor, size: 700mmX900mmX350mm approx, sheet :1.6mm thick, Angle :40x40x6mm,Channel:75X40mm (For MCCB'sIcs=100% Icu). The price also covers required concrete pedestal. The price shall cover the cost of all materials required for the above work including labour charges. Before supply of contractor has to take a p p r o v a l of drawing, switchgear, components other accessories of LT panel board from SrDEE/G/WAT or his authorized official.
Foundation of size: 0.8MX0.8MX1M with cum Excavation of earth pit in any type of soil/rock, Casting of Concrete foundation for erection of RS joist/GI octagonal pole etc - The price includes laying of cable along the concrete floor/black top road by cutting floor/black top road to be done by the contractor and the work shall be completed as per the direction of Engineer in Charge of work at site. The price shall be inclusive of charges for laying of cable in the concrete floor by digging the floor with contractor's labour and tool and top up to be done with suitable cement or black top. The work shall be executed as per the direction of Engineer in Charge of work at site. The IR values of cables are to be tested prior to laying, after laying and just before charging the cable and the values recorded should be jointly signed by Rly representative and authorized contractors representative WALTAIR DIVISION-ENGINEERING/ECOR
Supply, erection, testing and commissioning Numbers of Combined Unit of 63A Capacity Indutrial Plug Socket 380/415V 3P+N+E panel mounting IP/66/67 and 63A MCB TPN with enclosure - The rate is also inclusive of supply, erection, testing and commissioning of Combined Unit of 63A Capacity Industrial Plug Socket 380/415V 3P+N+E panel mounting IP/66/67 and 63A MCB TPN with enclosure. As per IEC 61439- Suitable for Flush Mounting and Surface Mounting, Supplied with Neutral Links, With provision for mounting modular devices as per site incharge directions. The tenderer shall get approval of material from Railway before supply. The makes and specifications are shown in Annexure.
Erection of RS joist/GI octagonal pole/Rail MT Pole/OHE Cut Mast etc. including cutting of Railway Supplied Unserviceable Rail Pole/RS Joist/OHE Cut Mast etc. before erection - The prices shall cover excavation, supply and handling of all materials, and accessories, temporary arrangement for excavation in hard soil and concrete/masonary drains/walls requiring use of Chisel and hammer 2 in requiring blasting 3, shoring where necessary, casting concrete including frame work where necessary tamping of concrete, grouting of masts and finishing the top of concrete foundation or anchor blocks. The price also includes dismantling of all connected temporary arrangements, back filling with earth and compacting the same to the required height and width as per drawing to ensure safety of foundation confirming the exposed height of foundation block to within 10 cm., and removal of soil. The purchaser's Engineer shall certify where use of chisel and hammer or blasting has been necessary. The contractor shall arrange for supply of explosives(with prior permission) and all tools and plants for blasting operations at his own cost. If half or more of the depth or width of excavation is in hard soil/concrete/ masonry drains/walls or in rock, the entire foundations shall be paid for under item 2 or 3 as the case, may be. If half of depth or width of the excavation is in hard soil/concrete masonry drains/walls and the other half is in rock, the entire foundation shall be paid under item 3. The price shall include the cost of cement.
Supply and fixing of MS Clamp made up of Numbers 25mmx4mm MS flat suitable for Rail Pole/RS Joist/OHE Cut Mast with necessary bolt & nuts - The rate inclusive of fixing, testing and commissioningMS Clamp made up of 25mmx4mm MS flat suitable for Rail Pole/RS Joist/OHE Cut Mast with necessary bolt & nuts. The work is to be completed with the contractorslabour, tools and all required materials including erection, testing and commissioning. WALTAIR DIVISION-ENGINEERING/ECOR
Supply Junction/Pole Box with loop in loop out similar to Sintex Make Cat ref. No. GSJB- 2520 with 6A-10A SP MCB C-curve - The rate inclusive of fixing, testing and commissioning FRP moulded Junction/Pole Box with loop in loop out similar to Sintex Make Cat ref. No. GSJB-2520 with 6A-10A SP MCB.The work is to be completed with the contractors labour, tools and all required materials including erection, testing and commissioning.
Supply & fixing of GI pipe 40mm dia Metre (medium) along with necessary bending to the required angle - The rate is inclusive of Supply & fixing of 40mm inner dia (Medium) G.I. pipe duly bend (1.2Mtr long each)Confirming to IS1239 - of 2004 or latest, at site as per the site requirement and as per Site Engineer's instructions. GI pipe should be of reputed make of Zindal/TATA.
erection, testing and commissioning of 36W Numbers led street light - The price shall covers the cost of erection, testing and commissioning of 36W led street light. Erection price also covers supply of required length pipe as per site requirement, if waranted.. The price shall cover the cost of all materials required for the above work including labour charges.
Single Cable Laying Along the road/Track - Metre The price shall cover the cost of transporting the UG cable from stores of work incharge office, or, other premises as directed by work incharge to work site& laying of cable shall be completed with contractors men &materialsand laying after excavation of earth in any type of soil. The dimension of trench number of bricks, sand bedding etc., shall be confirmed to the CEE/ECoR/BBS drawing No. CEE/GS/Cable Trench/01 (mod- 01) or latest. Price is also inclusive of refilling levelling and dressing of earth to be done contractors labour, tools and materials. The IR values of cable is to be measured before and after laying of the cable.
Single Cable Laying Across the road/track - Metre The price shall cover the cost of transporting the UG cable from stores of work incharge office, or, other premises as directed by work incharge to work site. & laying of cable shall be completed with contractors men & materials. The cable laying shall be in accordance with CEE/BBS's latest drawing No. CEE/GS/Cable trench/01 (mod-01). Price is also inclusive of refilling levelling and dressing of earth to be done contractors labour, tools and materials.The IR values of cable to be measured before and after laying of the cable.
Laying of Cable in open air - The unit price Metre shall cover for fixing of the cable on plinth/structure/column/culvert to be done by GI Clamp of suitable size as per site requirement. The distance of each clamp should not be more than 1 meter. The work should be completed with contractors' materials, tools & plants etc. WALTAIR DIVISION-ENGINEERING/ECOR
Cable Laying Through HDPE Pipe - The price Metre includes laying of cable through HDPE Pipe to be done by the contractor and the work shall be completed as per the direction of Engineer in Charge of work at site. The IR values of cables shall be tested jointly signed by Rly representative and authorized contractors representative prior to laying, after laying and just before charging the cable.
Laying of Railway supplied UG Cable of Metre different size: Along the Road double Cable - The price shall cover the cost of transporting the UG cable from stores of work incharge office, or, other premises as directed by work incharge to work site & laying of double cable shall be completed with contractors men & materials. Double cable laying along the road/track after excavation of earth in any type of soil. The dimension of trench, number of bricks, sand bedding etc., shall be confirming to the CEE/ECoR/BBS latest drawing No. CEE/GS/Cable Trench/01 (Mod-1). The cost is also inclusive of refilling of earth, levelling of earth to be done by contractors' labour, tools and materials. The work is to be completed with the contractors' labour, tools and all required materials including erection, testing and commissioning.Price is also inclusive of refilling levelling and dressing of earth to be done contractors labour, tools and materials. The IR values of cable to be measured before and after laying of the cable.
Laying of Railway supplied UG Cable of Metre different size: Across the Road/Track double cable - The price shall cover the cost of transporting the UG cable from stores of work incharge office, or, other premises as directed by work incharge to work site & laying of double cable shall be completed with contractors men & materials. The double cable laying shall be in accordance with CEE/BBS's latest drawing No. CEE/GS/Cable trench/01 (mod-01). Price is also inclusive of refilling levelling and dressing of earth to be done contractors labour, tools and materials. The work is to be completed with the contractors' labour, tools and all required materials including erection, testing and commissioning. Price is also inclusive of refilling levelling and dressing of earth to be done contractors labour, tools and materials. The IR values of cable to be measured before and after laying of the cable. WALTAIR DIVISION-ENGINEERING/ECOR
Earthing arrangement - The price shall Numbers include the cost for excavation of earth pits in any kind of soil, supply and erection of earth cone and strip including refill with salt, charcoal as per CEE/BBS's Drawing No. CEE/GS/Earthing/02 dt. Dt.21/02/2006 and connected by means of 6 SWG GI wire. The work shall also cover the cost of materials and labour charges for construction of sump as shown in the aforesaid drawing and the earth treated to obtain earth resistance of as per Rule. Connection of earth electrode should be made by providing clamp, nuts, bolts and 6 SWG GI wire. The price shall cover for supply and erection of earth pit cover made by RCC and make it complete in all respects as per above drawing. The price also covers 6 SWG GI wire from earth pit to nearest main supply point and installation. The makes and specifications are shown in Annexure.
Supply & erection of cable route marker - Numbers The price shall cover the cost of supply and erection of cable route marker as per sample approved by Sr.DEE(G) or his authorised representative. Cable route marker should be provided along straight runs of the cables at intervals of 50m or by site in-charge. The price shall cover the cost of all materials required for the above work including labour charges.
Supply & erection of outdoor type MS/FRP Numbers loop in loop out box made of 1.6mm thick MS sheet/FRP of size 200X150X100mm & 4way stud connector with provision of door in front side with locking arrangement - The price shall cover the cost of Supply & erection of outdoor type MS/FRP loop in loop out box made of 1.6mm thick MS sheet/FRP of size 200X150X100mm & 4way stud connector with provision of door in front side with locking arrangement The price shall cover the cost of all materials required for the above work including labour charges. Before supply of materials, contractor has to take approval from Sr.DEE(G)/WAT or his authorized official. WALTAIR DIVISION-ENGINEERING/ECOR
Supply, erection, testing and commissioning Numbers of out door feeder pillar consisting of copper bus bar 200Amp with LED type indication lamp for RYB in incoming side in a CRCA sheet with double door provision & locking arrangement. The panel shall be consist of I/C: 1X100A MCCB 4P 35KA with multifunction energy meter with 100/5A CTs, outgoing: 2X63A MCB TPN 10KA, 4x32A MCB TPN 10KA. Size:800mmX 600mmX375mm approx., sheet:1.6mm thick, Angle:40x40x6mm, Channel:75X40x6mm). Erection price also covers brick pedestal - The price shall covers the cost of Supply, erection, testing and commissioning of out door feeder pillar consisting of copper bus bar 200Amp with LED type indication lamp for RYB in incoming side in a CRCA sheet with double door provision & locking arrangement. The panel shall be consist of I/C: 1X100A MCCB 4P 35KA with multifunction energy meter with 100/5A CTs, outgoing: 2X63A MCB TPN 10KA, 4x32A MCB TPN 10KA. Size:800mmX 600mmX375mm approx., sheet:1.6mm thick, Angle:40x40x6mm, Channel:75X40x6mm). Erection price also covers brick pedestal. The price shall cover the cost of all materials required for the above work including labour charges. Before supply of materials, contractor has to take approval from Sr.DEE(G)/WAT or his authorized official.
Laying of cable along the concrete Metre floor/black top road by cutting floor/black top road without G.I pipe/HDPE Pipe - The price includes laying of cable along the concrete floor/black top road by cutting floor/black top road to be done by the contractor and the work shall be completed as per the direction of Engineer in Charge of work at site. The price shall be inclusive of charges for laying of cable in the concrete floor by digging the floor with contractor's labour and tool and top up to be done with suitable cement or black top. The work shall be executed as per the direction of Engineer in Charge of work at site. The IR values of cables are to be tested prior to laying, after laying and just before charging the cable and the values recorded should be jointly signed by Rly representative and authorized contractors representative.
Supply & erection of 40 mm Diameter PN-6, Metre PE-80 HDPE Pipe conforming to IS- 4984:2016 and Clamps including cutting and making good the walls etc - The price shall cover the cost of Supply & erection of 40 mm Diameter PE 80 HDPE Pipe and Clamps including cutting and making good the walls etc as per IS: 4984-2016 or latest(PN-4/PE-80, with minimum wall thickness of 6.2mm) OD=40mm. The price shall cover the cost of all materials required for the above work including labour charges. Before supply of materials, contractor has to take approval from Sr.DEE(G)/WAT or his authorized official. WALTAIR DIVISION-ENGINEERING/ECOR
Supply & laying of 6/8/12 SWG GI steel wire Kg - The price shall cover the cost of Supply and laying of 6/8/12 SWG GI wire as per IS 12776/2002 specification. The work shall be executed as per the direction of Engineer in Charge of work at site. The price shall cover the cost of all materials required for the above work including labour charges.
Supply, erection, testing and commissioning Numbers of 10 mtrs High mast tower complete as per ECoR's specification for high mast - (a) - Supply of 10Mtrs High Mast Pole in sigle section etc - The rate shall include the cost of Supply, erection, testing and commissioning of 10 mtrs High mast tower complete as per ECoR's specification for high mast with all foundation accessories, installation, testing & commissioning as per the details of technical specification. The price shall cover cost of excavation of earth pit in any kind of soil/rock for erection of pole with cement concrete in the ratio 1:4:8 casting of foundation including re-filling and dressing of earth with contractor's labour, tools including supply of cement and all materials. Digging of pit, casting of foundation / as shoen in drawing, with stone ballast of size 40mm/20mm and below for erection of with contractor's cement and mortar with ratio 1:4:8 and 12mm. thick cement plastering and neat cement finishing.(or mentioned in drawing). All the foundations are to be cured for 21 days. The price shall cover the cost of all materials required for the above work including labour charges. Price also include cost of concrete foundation, erection of lighting system with grouting bolt etc. if required as per site for commissioning of the entire system. Suitable foundation bolts shall be erected during foundation as shown in drawing. The price shall cover the cost of all materials required for the above work including labour charges. Before supply of materials, contractor has to take approval from Sr.DEE(G)/WAT or his authorized official. 10 MTR HIGH MAST TECHNICAL DATA SHEET
(b) Supply of control panel for high mast - Numbers The price shall cover the cost of Supply of control panel for high mast. The price shall cover the cost of all materials required for the above work including labour charges. Before supply of materials, contractor has to take approval from Sr.DEE(G)/WAT or his authorized official.
Supply of travelling cables copper 4core & Numbers 3core of required size etc - The price shall cover the cost of Supply of travelling cables copper 4core & 3core of required size etc. The price shall cover the cost of all materials required for the above work including labour charges. Before supply of materials, contractor has to take approval from Sr.DEE(G)/WAT or his authorized official. WALTAIR DIVISION-ENGINEERING/ECOR
Supply of single doom aviation lamp - The Numbers price shall cover the cost of Supply of single doom aviation lamp The price shall cover the cost of all materials required for the above work including labour charges. Before supply of materials, contractor has to take approval from Sr.DEE(G)/WAT or his authorized official.
Erection of 10 mtr hight mast with all Numbers accessories and Flood Lights etc. - The price shall cover the cost of Erection of 10 mtr hight mast with all accessories and Flood Lights etc The price shall cover the cost of all materials required for the above work including labour charges. Before supply of materials, contractor has to take approval from Sr.DEE(G)/WAT or his authorized official.
Supply of 200W Flood Lights as per CEE's Numbers specification of Make: Philips, Jaquar, Havells. - The price shall cover the cost of Supply, of 200W LED Flood Light Luminaires.. The make and specifications are as per CEE/ECoR's Specification No. ECoR/PCEE/LED FLOOD LIGHT/05-2018, dt.24.09.18 Mod-1 @ 2021. make and specifications are as per CEE/ECoR's Specification approval from SrDEE(G)/WAT or his authorized representative is to be obtained.
Casting of RCC foundation for High Mast as cum per OEM's Design & Drawing approved by Railways - The price shall cover the cost of Casting of RCC foundation for High Mast as per OEM's Design & Drawing approved by Railways. The price shall cover the cost of all materials required for the above work including labour charges. Before supply of materials, contractor has to take approval from Sr.DEE(G)/WAT or his authorized official. Total 4329210.15
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
SpecialConditionsforCivilWorks.pdf
ATTACHMENT
SpecialConditionCementandSteel.pdf
ATTACHMENT
GCC-2022.pdf
ATTACHMENT
PRICEVARIATIONCLAUSE.pdf
ATTACHMENT
TENDERFORMFIRSTSHEET.pdf
ATTACHMENT
ANNUALCONTRACTUALTURNOVERDATA.pdf
ATTACHMENT
BIDSECURITYBGBOND_1.pdf
ATTACHMENT
EFTFORM.pdf
ATTACHMENT
ACS-11-GCC-2022_c.pdf
ATTACHMENT
Anx-I-GuaranteeBond_1.pdf
ATTACHMENT
InstructionstotheTenderer_2.pdf
ATTACHMENT
Boardletter-GraduateEngineer-DiplomaEngineer.pdf
ATTACHMENT
AnnexureVandVAmodified.pdf
ATTACHMENT
Annexure-VI-BidCapacity.pdf
ATTACHMENT
GCC-2022-ACS-1to10.pdf
ATTACHMENT
JPO-Circular-GuidelinesforprotectionofCables.pdf
ATTACHMENT
ELECTRICALSPECIALCONDITIONSRECENT2026.pdf
ATTACHMENT
MAKESANDSPECIFICATIONS.pdf
ATTACHMENT
ElectricalScheduleBTPN_c.pdf
ATTACHMENT
CompositetenderletterBTPN.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].