Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance JAVERI BUNGALOW AREA KAVERI HOTEL LINE NH PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
22 Jan 2025, 9:15 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ELECTRICAL OFFICER
ICGS SARTHAK, PORBANDAR
AS PER TENDER
2025_ICG_693581_1
443/STK/ELE/49/RM/24-25
Limited
Marine Works
Works
ICGS SARTHAK
Please refer Tender documents.
1 document required · 1 mandatory
₹0
Exempted
23 Jan 2025
17 Jan 2025
23 Jan 2025
17 Jan 2025
22 Jan 2025
17 Jan 2025
Various defects on electrical equipment.
L-1283. Galley hot plate no 2 not working view wiring showing short circuit. Wiring to be renewed with heat insulation and lugs as per sample. Wiring 02 mtrs 1.5 sq mm. Defect to be rectified and proved for satisfactory operation.
L-1284. ASP exhaust not working and tripping overload and overheat suspect control circuit malfunctioning. Defect to be rectified and proved for satisfactory operation.
L-1285. Stbd accommodation ladder not cutting off during hoisting suspect limit switch wiring open circuit. Limit switch wiring to be renewed as per sample. Wiring 05 mtrs 1.5 sq mm two core. Defect to be rectified and proved for satisfactory operation.
L-1310. Ships electric siren not working view motor showing low insulation and motor casing perished. Defect to be rectified and proved for satisfactory operation.
L-1311. Signalling projector (P&S) control supply box deteriorated. Both control supply box to be renewed. Mat: SS, Dimension: 1.5 Ft x 2 Ft x 6 Inch. HV Igniter, Rectifier to be fitted and all connections to be completed. Both Signalling projectors to be proved for satisfactory operation.
L-1353. Gun Deck and boat deck LED flood light base plate is deteriorated. Base plate is to be replaced. Hot work involves MS welding and cutting.
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .