Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79,646Accepted-AOC | ₹79,646 Quoted ₹79,645.52 | L1 | Accepted-AOC I st lowest Bidder |
| 2 | L2₹80,127.34Rejected-AOC | ₹80,127.34 | L2 | Rejected-AOC II nd lowest Bidder |
| Sl No | Description | Qty | Unit | SANISH M S L2 | N P ABHILASH L1 |
|---|---|---|---|---|---|
| 1.00SITC OF INVERTER | |||||
| 1.00 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 49 | metre | 285.04 ₹13,966.96 | 109.53 ₹5,366.97 |
| 1.00 | 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm | 40 | metre | 245.06 ₹9,802.40 | 169.15 ₹6,766 |
| 1.00 | 1.23.3:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch | 2 | each | 2,064 ₹4,128 | 139.76 ₹279.52 |
| 1.00 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | 11 | each | 285.03 ₹3,135.33 | 118.41 ₹1,302.51 |
| 1.00 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch | 2 | each | 246.03 ₹492.06 | 179.42 ₹358.84 |
| 1.01 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet | 16 | each | 196.02 ₹3,136.32 | 140.46 ₹2,247.36 |
| 1.01 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet | 2 | each | 285.3 ₹570.60 | 226.71 ₹453.42 |
| 1.01 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) | 2 | each | 396.03 ₹792.06 | 377.01 ₹754.02 |
| 1.01 | 1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) | 5 | each | 536.2 ₹2,681 | 523.13 ₹2,615.65 |
Tender Value
Refer Docs
EMD Value
₹1,991
Closing Date
10 Feb 2026, 6:00 pmClosed
Assistant Executive Engineer
PWD Electrical Subdivision, Palakkad
DEPOSIT-SITC of inverter at Grama Nyayalaya, Thenkurussi, Palakkad-SITC OF INVERTER-General Electrical Work
2026_PWD_834309_1
ET-71/ESDPKD/2025-2026
Open Tender
Electrical Works
91 days
Palakkad
Please refer Tender documents.
11 documents required · 11 mandatory
₹555
₹1,991
18 Jun 2026
6 Feb 2026
13 Feb 2026
6 Feb 2026
10 Feb 2026
6 Feb 2026
SITC OF INVERTER
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.23.3:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
OD296961/2025-2026:Supply , Installation , Testing and Commissioning of sine wave inverter of rating 2 KVA /24 V with TUBULAR BATTERY 150 AH/12V (MODEL: 150 AH/12V) -2 NOS. battery with Interconnecting cable, Nut & Bolt etc including all connections HYKON-(MODEL: SP 2500/24 V) make/eqt with suitable stand
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1403303.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
Tendernotice_2.pdf
PDF • 0.21 MB
SBD.pdf
Tender Documents • 3.04 MB
BOQ_1403303.xls
BOQ • 0.31 MB
NIT.pdf
Tender Documents • 0.02 MB
Download all tender documents and submit your bid