Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹44.6 L+₹3.9 L (9.55%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | Rejected-Technical 10 SUBASH COLONY DEF LAB ROAD RATANADA JODHPUR 342006 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342006 | - | Rejected-Technical Not Eligible bidder as not enlisted in eligible cat. i.e. c vi therefore not satisfies the eligibility criteria as per NIT |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
11 Apr 2025, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
CMC FOR FIRE ALARM SYSTEM AND OTHER CONNECTED ITEMS INSTALLED AT MH JODHPUR AND HQ CEJZ AND SERVICING / MAINTENANCE / REPAIRING OF VRV SYSTEMS AND AIR COOLING SYSTEMS AT MH JODHPUR UNDER GE (A) NO. 02 JODHPUR
2025_MES_694293_2
82425/101/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (ARMY) NO. 02 JODHPUR
₹86,000
Yes
23 May 2025
21 Mar 2025
14 Apr 2025
21 Mar 2025
11 Apr 2025
28 Mar 2025
22 Mar 2025 - 27 Mar 2025
Amount
Servicing and cleaning of the following outdoor unit of VRV system (6-Nos) by cleaning/wash with appropriate chemical/detergent of whole unit and remove the dust particles, cleaning of all parts inside of unit and minor replacement parts such as nut bolts screw of any type upto satisfactory complete all as specified and directed by Engr-in-Charge :-
System No 1 (54 HP) installed at MH Jodhpur main bldg terrace.
System No 2 (40 HP) installed at MH Jodhpur main bldg terrace.
System No 3 (36 HP) installed at MH Jodhpur main bldg terrace.
System No 4 (54 HP) installed at MH Jodhpur main bldg terrace.
System No 5 (42 HP) installed at MH Jodhpur main bldg terrace.
System No 6 (56 KW) installed at MH Jodhpur Adm Bldg terrace.
Servicing and cleaning of Cassette unit (Ceiling mounted) of VRV System of any capacity installed at various location in NEW MH and Adm Block Jodhpur including Filter Wash, Cooling / Evaporative coil wash and remove the dust, complete all as specified and directed by Engr-in-charge. Note:- 1. Servicing of ceiling mounted cassette type will be carried out two times in a year (61 Unit x 2 =122 Job) as per directed.
Servicing and cleaning of Air Handling Unit(AHU) indoor type for VRF system installed at various location, including Filter Wash ,Cooling/Evaporative Coil Wash and remove the dust particles, cleaning/greasing of all part including minor replacement parts such as nut bolts screw of any type for system units complete all as specified and directed by Engr-in-charge. Note :- Servicing of AHU units will be carried out two times in a year (04 Units x 2 = 8 Job) as directed.
Supply and Fixing in repairs of complete outdoor unit 18 HP for VRV system, 420 Volt including testing, commissioning, necessary electric connection, bracing of copper pipes, syncronize with the old systems (VRV-X model) complete all as specified and directed by Engr-in-charge. Note : (i) Gas charging will be paid separately (ii) Nitrogen with vacuum test will be done and included in the quoted rates.
M & L for shifting complete outdoor unit upto 18 HP for VRV system, 420 Volt including installation at new location within 150 metre range, testing, commissioning, necessary electric connection, bracing of copper pipes, syncronize with the old systems(VRV-X Model) complete all as specified and directed by Engr-in-charge. Note : (i) Gas charging will be paid separately (ii) Nitrogen with vacuum test will be done and included in the quoted rates.
Supply and Fixing in replacement of compressor 05 HP 420 Volt for outer unit of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and Fixing in replacement of compressor 06 HP 420 Volt for outer unit of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of compressor Invertor Type 06 HP for outer master unit of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and gas charging refrigerant gas 410 A or as required for system up to required level incl connected work including pressure testing with nitrogen before filling regrigerant gas in VRV System of 12 to 18 HP complete all as specified and directed by Engr-in-charge. Note : Nitrogen test/Vacuumization using vacuum pump will be incuded in quoted rates.
Supply, fixing and testing in replacement unserviceable Heat Exchanger/condensor for Out door unit upto 18 HP of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Material & Labour for taking down unserviceable burnt Electric exhaust (Condensor) DC fan Motor of any type and size capacity from VRV outdoor unit and fixing after repairing and servicing rewinding on existing location with proper fitting and testing complete all as specified and directed by Engr-in-charge.
Supply,fixing and testing of Invertor PCB for Out door unit of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and fixing of Mother Board / Main / Control PCB for outdoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and fixing of filter PCB for outdoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and fixing of Power / Over voltage PCB for outdoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and fixing of Fan PCB for outdoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and fixing of Expansion Valve assembly for outdoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of high pressure / low pressure switch for outdoor unit of VRV System incl all connected work with pressure testing of nitrogen before filling regrigerant gas in VRV System of 12 to 18 HP complete all as specified and directed by Engr-in-charge. Note : (i) Refrigerant Gas 410A will be paid separately (ii) Nitrogen testing will be included in the quoted rates.
Supply and fixing Return Air Sensor for indoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and fixing Display Sensor for indoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and fixing Drain Pump for indoor unit of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and fixing Bearing suitable for existing AHU of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and fixing Expansion Valve for AHU of VRV System of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
M&L for repair/servicing/maint of PCB for indoor unit cassette type of VRV System with remote complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of unserviceable PCB for indoor unit cassette type of VRV System with remote of any capacity including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Taking out old damaged VRV copper tubing insulation and supply and fixing for tubing insulation with nitrle insulation of thickness 13 mm complete all as specified and directed by Engr-in-charge including the following:- (a) M & L for cleaning the surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust,grease and other foreigen material, taking special care so that all duct joints are sealed against any leakages. (b) M & L for appling rubber based adhesive CPRX compound.
S&F in replacement of MCB, C Curve type, 10 kA, 100 Amp, TPN with over load and short circuit protection, complete all as specified and directed by Engr-in-charge.
Supply and fixing security light termination/junction box of size 300x200x105mm, weather proof, along with connector for 3 phases suitable for fixing MCB TPN upto 63 Amps complete all as specified and directed by engineer-in-charge.
M&L for attending VRV System faults at New MH /Adm bldg to check for serviceability of continuous cooling effect rectifying including carrying out minor repairs / replacement etc as required, complete all as specified and directed by Engr-in-charge. (i) Any other replacement of major items shall be measured & paid separately under respective items of this schedule. (ii) Minor items will be included on the quoted rates only.
Prevantive maintenance and cleaning of the following Air cooling plants filters (Pre AIR Filters and Honey comb filters) by use of liquid soap solution/detergent powder including minor replacement of defective parts of Air cooling plants- 20 Nos electrically operated installed in MH Jodhpur area complete all as specified and directed of the Engr-in-Charge :-
Air cooling plant 4000 CFM, installed at MH main bldg terrace-01 No.
Air cooling plant 5000 CFM, installed at MH main bldg terrace-02 Nos.
Air cooling plant 6000 CFM, installed at MH main bldg terrace-02 Nos.
Air cooling plant 7000 CFM, installed at MH main bldg terrace-03 Nos.
Air cooling plant 8000 CFM, installed at MH main bldg terrace-02 Nos.
Air cooling plant 9000 CFM, installed at MH main bldg terrace-01 No.
Air cooling plant 10000 CFM, installed at MH main bldg terrace-01 No.
Air cooling plant 12000 CFM, installed at MH main bldg terrace-01 No.
Air cooling plant 14000 CFM, installed at MH main bldg terrace-01 No.
Air cooling plant 15000 CFM, installed at MH main bldg terrace-03 Nos.
Air cooling plant 16000 CFM, installed at MH main bldg terrace-01 No.
Air cooling plant 20000 CFM, installed at MH main bldg terrace-01 No.
Air cooling plant 28000 CFM, installed at MH Adm bldg terrace-01 No.
Supply and fixing V-belt as per existing ISI mark including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and fixing testing Ball bearing set as per existing Air Cooling blower rotor shaft of cap 05 HP motor of any description as approved complete all as specified and directed by Engr-in-charge.
Supply and fixing testing Ball bearing set as per existing Air Cooling blower rotor shaft of cap 10 HP motor of any description as approved complete all as specified and directed by Engr-in-charge.
Supply and fixing angle Base frame (with anti vibration pads) suitable for electric motor of Air Cooler system upto 10000 CFM. Note : - Base frame should match as par existing unserviceable frame and should be fitted in proper location by matching the alingment of system with blower fan upto satisfacory condition complete all as specified and directed by Engr-in-charge.
M & L for taking down unserviceable water pump set upto 1 HP capacity from foundation dismantling pump motor for servicing/ replacement of unserviceable bearing, gland bush and rewinding of motor reassembling after repair/servicing reinstall on existing location & testing complete all as specified and directed by Engr-in-charge.
S&F in replacement water pump set upto 1 HP capacity for Air cooling plant installed at MH Jodhpur complete all as specified and directed by Engr-in-charge.
Supply and fixing Gate Valve/butterfly valve 20/25 mm for water control for Air Cooler unit including taking down unserviceable complete all as specified and directed by Engr-in-charge.
As per item No 37 but for size of 50 mm complete all as specified and directed by Engr-in-charge.
Supply and fixing Float Valve with complete tab assembly 20/25 mm including taking down unserviceable complete all as specified and directed by Engr-in-charge.
M&L Pre Air Filter EU-4 type for fresh Air for Air Cooling Unit including taking down unserviceable complete all as specified and directed by Engr-in-charge.
M&L for filter Honey Bee Pad of size 8" thickness for air cooling system installed various location at New MH as per existing including taking down unserviceable complete all as specified and directed by Engr-in-charge.
Supply and fixing Complete Canvas Clothes (Zip arrangement) with S/S body frame of suitable size of any description as per existing and complete all as specified and directed by Engr-in-charge.
Taking out old damaged AC duct insulation and supply and fixing for duct insulation with Alluminium laminated (for UV protection) with nitrle insulation of thickness 13 mm and complete all as specified and directed by Engr-in-charge including the following:- (a) M & L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to completely free of millscale, dirt, dust,grease and other foreigen material, taking special care so that all duct joints are sealed against any leakages. (b) M & L for appling rubber based adhesive CPRX compound.
S & F in replacement automatic starter complete unit suitable for capacity upto 10 HP motor including connected accessaries complete all as specified and directed by Engineer-in-charge.
M&L for painting of Air cooling system inner body, scratch and remove old rusting materials with sand paper and after necessary painting will be done through one coat with red oxide and other coat with rubber based paint complete all as specified and directed by Engineer-in-charge
M&L for Servicing / Maintenance/Cleaning / testing and commissioning of complete Fire Alarm system installed at Military Hospital Jodhpur which is consist following items :- (a) Multi smoke /Heat detector - 1824 Nos. (b) Addresable Control/Monitor Module -50 Nos (c) Fire Alarm sounder/speaker - 100 Nos. (d) Response Indicator - 906 Nos. (e) Addresable MCP- 40 Nos (f) Microprocessor based main control panel - 02 Nos. (g) Repeater panel - 06 Nos (h) Main Hooter -01 Nos and other connected items for their connection i.e. cable and servicing complete all as specified and directed by engineer-in-charge. Note:- (i) Properly making notes of functional and non functional items for submission to engineer-in-charge (ii) Replacement cost of minor part included in above mentioned cost (ii) Replacement of unsv items/ parts suitable for fire alarm system shall be paid seperately under respective items.
Supply, Installation, Testing, Commissioning Analogue addressable type Multicriterion Smoke Detector with sounder base, address switch including taking down old unsv complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing, Commissioning Addressable pull station type manual call points complete with address switch including taking down old unsv complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing, Commissioning Horn cum strobe hoter with addressable switch complete as required including taking down old unsv complete all as specified and directed by Engineer-in-Charge.
Repair/Maintenance , Testing, Commissioning Addrssable type Loop Card complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing, Commissioning Addrssable type power supply including power line surge barrier with emi/ref filter including taking down old unsv complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing, Commissioning Addressable type Fault Isolators for isolating shorted, de-wired and loose circuits between two successive Fault isolators with automatic resetting arrangement including taking down old unsv complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing, Commissioning and replacement Addressable control module for connecting to Flow Switch and Fire Fighting System etc. complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing, Commissioning Response indicator consisting of 16 gauge MS box with 75 x 75 x 6 thick cross brushed aluminium face plate for above false ceiling detectors. (for above false ceiling detectors) including taking down old unsv complete all as specified and directed by Engineer-in-Charge.
Repair/Maintenance , Testing, Commissioning addressble network card addressable module to connect repater panel with the addressable panel complete all as specified and directed by Engineer-in-Charge.
MAIN FIRE ALARM CONTROL PANEL Repair,maintenance,programming , testing and commissioning of micro-processor based logic driven analogue addressable 4 wire (loop as described below), network cable type Main Fire Alarm control panel Make: Siemens (each loop accessing minimum 250 addressable detectors & 250 addressable devices). The panel shall be able to give pin point location of all fire/fault conditions of addressable units via the address codes for each unit. The panel shall also be able to automatically switch off all control switches when ever any alarm is triggered. The Panel shall have its own integrated PA System having amplifiers suitable for given No. of speakers and maximum 15 channels. The panel shall have sealed maintenance free batteries of suitable capacities (paid separately) capable of running 24 hrs in normal condition followed by 30 minutes in alarm condition with battery charger ,rectifier ,key pad operation,piezo sounder as directed by engineer-in-charge. The panel shall provide field device address with progrming complete all as specified and directed by Engineer-in-Charge with following feature:- (i) area, inbuilt/exernal printer to log all incoming data etc complete in all respects.(ii)The panel shall have programmable switch plates for controlling Horn Strobe Zones/AHU shut off etc. from panel itself.(iii)The panel shall have its own master fire fighting telephone/audio control/command centre.(iv)The panel shall have inbuilt auto dialer with minimum six line output.(v)The Panel shall also have Logic hardware and software built into it for initiating specific AHU tripping, time delay operation of strobe, subsequent operation of hooters. (vi)power line surger barrier with emi/ref filter input Note:-(a)Each loop of fire alarm panel shall have 20% spare addressable units.(b)The panels must be networked end to end and all panels global access to be provided.(c)Information of all the panel shall be accessable from any of the panels through networking.(d)Panel shall be upgradable to 25% more loops until & unless specified.(e)Other requirements are given in the specifications.(f)The No. of loops may be changed based on the loop capacity of the panel.
Supply and fixing testing and commissioning of zero loop Repeater Panel for Fire Alarm System with piezo sounder, LCD alpha numeric character display with accept/reset buttons for alarm address of any sensor/field device. The repeater Panel shall be active and all the settings can be configured with this panel including taking down old unsv complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing, Commissioning fire alarm control panel Addresable PMI Display unit including taking down old unsv complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacment maintenance free battery 12 V 7 AH including terminal complete all as specified and directed by engineer-in-charge.
Supply and laying including termination of 2 core 1.5 Sqmm stranded PVC insulated PVC sheathed copper conductor 1100Volt grade fire resistant armoured cable including terminations, all labour and material etc. complete (Panel to Detectors Devices, for repeater panels,above false ceiling detectors & response indicator). complete all as specified and directed by Engineer-in-Charge.
Supply and fixing flexible 20 mm dia G.I conduit ISI marked including all necessary supports, clamps, joining pieces etc for drop of cables from slab to detector. complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 40 x 200 x 40 x 2 mm thick slotted angle stove enamelled cable tray ISI marked for fixing on walls including all nuts, bolts, washers etc. for runs of armoured cables complete all as specified and directed by Engineer-in-Charge.
Supplying, installing and jointing of MS conduits upto 25 mm bore ISI marked on surface or concealed complete with MS junction boxes, cover plates, MS bends, GI saddles, base and other accessories all made in MS with GI screws as required to complete the job. Exposed conduiting shall be painted with red enamel paint for identification. complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised earth lead wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 25 mm bore including provision of concrete pit made from PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
Anil Builders (BID ID -3272820)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .