| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC 0 PRAGATIPUR DHARMA SARMA PATH BIRUBARI KAMRUP ASSAM 781016 | KAMRUP METRO | ASSAM | 781016 | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹16.6 L+₹1.0 L (6.63%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹17.7 L+₹2.2 L (13.9%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹24.0 L+₹8.4 L (54.0%)Rejected-Finance SHREE KUNJ HOUSE NO 22B JIBAN KRISHNA PATH NEAR L P SCHOOL HENGRABARI GUWAHATI PIN 781036 | GUWAHATI | KAMRUP | ASSAM | 781036 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
24 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barjhor
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
REPAIR/MAINTENANCE OF LT ELECTRICAL DISTRIBUTION SYSTEM AND ALLIED WORKS AT MOUNTAIN SHADOW AREA AT GE (AF) BORJHAR
2023_MES_577491_1
8328/BOR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CE Shillong
MES Contractor enlisted as Class E category b(i) having deposited Standing Security of Rs 50000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Barjhor
₹40,000
Yes
23 May 2023
27 Jan 2023
27 Feb 2023
27 Jan 2023
24 Feb 2023
10 Feb 2023
Amount
Excavation in trenches not exeeading 1.5m wide and not exceeding 1.5m depth/width and getting out loose/soft soil for laying of under ground cable complete all as specified and directed.
Returning/ filling including spreading, levelling and well ramming in layers not exc 25cm in thick complete all as specified and directed.
Removal of surplus soil to a distance not exc 50m away and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and spread sand in cable trenches and providing cushioning for the cable complete all as specified and directed. Note:- Only punned thickness of 18cm will be measured for the purpose of payment.
Supply and lay burnt brick of size 230x115x75mm for protection of cable, laying in trenches complete all as specified and directed.
Relying old serviceable burnt brick in trenches for under ground cable protection retrived against item No 7 here in before complete all as specified and directed.
Taking out / down unserviceable 1.1KV, LT UG cable from existing trenches/duct/ HT poles of any cross sectional area including disconnecting, PCC covers, GI Pipe etc. of any descriptions, segregation of serviceable materials viz PCC cable cover, GI Pipes, UG cables etc. and tracing the location of fault and keeping in safe custody for re-use complete all as directed NOTE : (i) Earth work shall be measured and paid for separately under relevent items. (ii) Serviceable cable covers, cables and GI pipes shall be kept aside for re-use.
Relaying of old LT cable XLPE insulated with aluminium conductor of size from 25 to 95 sqmm, 3.5/4 core, 1100 volts grade complete all as specified and directed.Note : - (i) Seviceable LT cable obatined from ser item No.7 shall be used.
Supply and Laying LT underground cable XLPE insulated and sheathed armoured cable 1100 volts 2 core 10 Sqmm aluminium conductor in trenches/poles and connecting with all accessories lugs & glands complete all as specified and directed.
All as per item No.09 above but of cable 4 core 16 Sqmm complete.
All as per item No.09 above but of cable 3.5 core 25 Sqmm complete.
All as per item No.09 above but of cable 3.5 core 35 Sqmm complete.
All as per item No.09 above but of cable 3.5 core 95 Sqmm complete.
S&F 1100 Volts heavy duty round sheathed multistranded three core bright annealed bare copper conductor cable of size 1 Sqmm for electrical connections to the street lights fittings including taking out old cable complete all as specified and directed.
S&F LED Flood light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 66 protection luminaries of capacity 60 Watt complete all as specified and directed.
S&F LED Flood light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 66 protection luminaries of capacity 200 Watt complete all as specified and directed.
Supply and fix LED Bollard light 10 W IP 65, 230 volts,50Hz energy saving,inverted Pyramid tripod type LED bollard with soft 360 deg light distribution complete with twin core copper conductor suitable size complete all as specified and directed.
M&L for painting the swaged steel tubural LT poles including cross arms,clamps and light bracktes surface of any discription after preparation of old painted surface(removing old paint by paint removers and cleaning with scraper any number of exiting coats) with one finishing coat aluminium paint and marking pole no. as per exiting numbers and painting of lower portion of pole in alternate layer of black and yellow shades/colour complete all as specified and directed.
M&L for painting the swaged steel tubural HT poles including cross arms,clamps and light bracktes surface of any discription after preparation of old painted surface(removing old paint by paint removers and cleaning with scraper any number of exiting coats) with one finishing coat aluminium paint and marking pole no. as per exiting numbers and painting of lower portion of pole in alternate layer of black and yellow shades/colour complete all as specified and directed.
Supply only GI bracket fixing suitable for street light fitting made out of 40mm dia GI tubing of light grade bent to shape of 1.5m length complete including taking out old complete all as specified and directed.
S&F HOT moulded (FRP) jucntion box for street light pole with locking arrangementt with IP -65 protection of size 300 x 200 x 105 mm (inside dimension) with 4 Nos aluminium busbar strip of suitable rating upto 63 Amps capacity mounting on DMC insulators (08 Nos) with nuts and bolts complete with 06 Amps MCB SP fixed over din rail and one bracket & nuts and bolts of suitable size to fix with pole complete all as specified and directed by Engineer-in-Charge. Make-Sintex Note : (i) Each aluminium busbar having 4 to 5 holes for connection of cable with nuts and bolts etc (ii) Rate for MCB SP and clamp with nuts & bolt are inclusive in the above rate.
S&F of pin type, porcelain vitreous while brown of green insulator including one Galvanised mild steel spindle two galvanised iron washers and one Galvanised iron nut 150mm Height 150mm dia for 11000 Volts complete including taking down old unserviceable insulator all as specified and directed .
S&F Single disc type insulator assembly porcelain vitrous for tension with tession clamps for conductor working pressure 11000 Volts complete including taking down old unserviceable insulator all as specified and directed .
M&L for PCC 1:2:4 type B 2 using 20mm graded stone aggregates as in coping etccomplete all as specified and directed.
S&F GI tubing of 50mm dia light grade at road cross for protection cable as per site requirement and sealing the pipe both ends with sealing compound complete including taking down old one complete all as specified and directed. Make :- TATA/ Zindal/SAIL
All as per item No.28 above but 80mm dia complete Make :- TATA/ Zindal/SAIL
Supply only lugs for UG cable of different sizes cable 16/25/35/50/70/90 Sqmm complete all as specified and directed.
M & L for restringing of LT over head ACSR conductor form pin, disc, shackle insulators with suitable binding wire to insulators and connecting in 4 conductor system position complete all as specified and directed . Note:- 4 run of ACSR conductor will be measured as one length.
M/L for PVC line separator suitable for 4 wire LT O/H lines at any height complete all as specified and directed.
M/L for PVC line separator suitable for 2 wire LT O/H lines at any height complete all as specified and directed .
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including taking down of old one complete all as specified and directed.
M&L for triming of tree branches (touching HT/LT OH line)uptto 10cm girth at any height carefully taking shutdown including suitable disposal of cut of tree branches as in repair complete. Note:- tools & plants including safety measures equipments like belt,ladder & rops etc shall be arranged by the contractor at own cost.
Cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exc 60 mtr complete. (Note :- Item shall be executed twice in each installation and quantity is given for two operation. However unit rate to be quoted by the tendered for single operation only)
S&F for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size completecomplete all as specified and directed.
M&L for boring of hole under road, pavement hard standing by trenchless technology using ultra sounding techinque of 0.4 mpa working pressure of size 80 mm dia complete all as specified and directed .
S&F including connection and testing MCCB, 4 Pole, microprocessor based, 415 Volts, breaking capacity 35/36 KA of rating 160 Amps as in repair complete all as specified and directed.
All as per item No.29 Above but 250Amps complete.
S&F 1100 volts grade heavy duty cable PVC insulated Stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1metre apart including 4mm suspension wire, one twin core cable flat or circular of 10 Sqmm, complete all as specified and directed.
S&F 1100 volts grade heavy duty cable PVC insulated Stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 16 Sqmm complete all as specified and directed.
Supply, install, testing and commissioning of 11KV outdoor type Polymer based gang operated air brake switch triple pole, suitable for verticle mounting complete with explusion fuses, GI operating rod of suitable length for operating mechanism worked from ground level complete in both OFF and ON positions, for current rating upto 200 Amps, each pole consist of galvanised steel base HT insulators as per BSS / ISS non ferrous knife and spring loaded contacts, arcing horns of adequate section to brake magnetizing current of the transformers. All ferrous parts hot dipped galvanised and non ferrous parts heavelly tinned to withstand weather including dismantling the existing one complete all as specified and directed.
S&F in repairs Polymer based dropout fuse unit complete set suitable and including for 11 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing and commissioning complete all as specified and directed.
S&F lightening arrestors expulsion type HT 11KV complete with all fittings, transmission class, discharge capacity 65 kilo amps with all fittings complete including taking down old unserviceable lightening arrestors all as specified and directed .
Earthing complete with Copper earth plate electrode 600×600× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to Copper earth lead of size 25x3mm thick by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion all as specified and as directed.
M&L for taking out solar street light fittings with MS/GI pipe of 6 mtr height including complete with dismantling of existing PCC and re-locate the same including necessary excavation earth work, foundation and coping etc complete all as specified or indicated including testing on completion all as specified and as directed.
M&L for repairing of existing electrical panel front and rear door hinges by welding work and making smooth surface of welded surface by rubbing and polishing with the same existing colour complete all as specified and as directed.
Material & Labour for preparation of old painted surface of electrical panel inner and outer surface complete of any size and any make by scrubbing with iron brush and applying two coat synthetic enamel paint with spray machine complete all as specified and directed .
(a) Lengh (0.5m to 1 m), Height(0.5m to 1m), Breadth(Up to 0.5 m)
(b) Lengh (0.5 m to 1 m), Height(1 m to 2 m), Breadth(Up to 0.5 m)
(c ) Lengh (1 m to 2 m), Height(1 m to 2m), Breadth(Up to 0.5 m)
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron steel wire 4mm dia as earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI medium grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part I 2009 all as directed.
S&F of pin type, porcelain vitreous while brown of green insulator including one Galvanised mild steel spindle two galvanised iron washers and one Galvanised iron nut 100mm Height 65 mm dia for 1100 Volts complete including taking down old unserviceable insulator all as specified and directed .
S&F of shackle type insulator porcelain virtuous white, brown or green 75mm Height 90mm dia for 1100 volts grade including one Galvanized mild steel straps washers insulator bolts washers and nuts complete including taking down old unserviceable insulator complete all as specified and directed.
Dismantling of ACSR conductor, service feeder or distributor span from its existing position complete all as directed.
Supply, stringing and fixing on existing/new poles, ACSR conductor of any type/ size including fixing to insulators with binding wire complete all as specified and directed.
M/s B.M. Enterprise
ANZ CORPORATION
M/S PRASANTA MAHANTA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .