| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.5 CrAccepted-AOC MANATHA ENCLAVE 3RD FLOOR OLIMUGAL KAKKANAD P O KOCHI 682 030 KERALA | ERNAKULAM | KERALA | 682030 | ₹48.5 Cr | L1 | Accepted-AOC Accepted being lowest and quoted amount found reasonable. |
| 2 | L2₹52.2 CrRejected-Finance GP KIZHAKKAMBALAM KOLENCHERY | THRISSUR | KERALA | 680667 | ₹52.2 Cr | L2 | Rejected-Finance Rejected being not lowest. |
| 3 | L3₹54.8 CrRejected-Finance 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | ₹54.8 Cr | L3 | Rejected-Finance Rejected being not lowest. |
| 4 | L4₹55.1 CrRejected-Finance PREMISES NO 5 30 5 N C SENGUPTA SARANI GROUND FLOOR MALL ROAD KOLKATA WEST BENGAL INDIA 700 080 | KOLKATA | KOLKATA | WEST BENGAL | 700080 | ₹55.1 Cr | L4 | Rejected-Finance Rejected being not lowest. |
| 5 | L5₹55.6 CrRejected-Finance | ₹55.6 Cr | L5 | Rejected-Finance Rejected being not lowest. |
Tender Value
₹58.8 Cr
EMD Value
₹32.6 L
Closing Date
20 May 2024, 6:00 pmClosed
CE NW Kochi
MILITARY ENGINEER SERVICE NAVAL BASE POST KATARIBAGH KOCHI 682004
PROVISION OF DEFICIENT SINGLE LIVING ACCN FOR JUNIOR SAILORS AT NAVAL BASE KOCHI
2024_MES_641239_1
891046/E8
Open Tender
Civil Works
900 days
KOCHI
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹3,000
Yes
GE (P) (NW) KOCHI
₹32.6 L
Yes
24 Jun 2024
13 Feb 2024
22 May 2024
14 Feb 2024
20 May 2024
6 May 2024
Amount
Total amount of Sch 'A' Part-I : (Buildings/ Structures )
Total amount of Sch 'A' Part-II : Excavation, earthwork, site clearance and site development)
Total amount of Sch 'A' Part-III : (Internal Water Supply)
Total amount of Sch 'A' Part-IV : (Internal Electric Supply)
Total amount of Sch 'A' Part- V : (External Water Supply )
Total amount of Sch 'A' Part-VI : (External Electric Supply)
Total amount of Sch 'A' Part-VII : (Lightning Protection)
Total amount of Sch 'A' Part-VIII : (Fire Fighting System)
Total amount of Sch 'A' Part-IX : (Area Drainage)
Total amount of Sch 'A' Part-X : (Sewage Disposal)
Total amount of Sch 'A' Part-XI (Road/ Path/ Hardstanding )
Total amount of Sch 'A' Part-XII : (Lift)
Total amount of Sch 'A' Part-XIII (DG Set)
Sch 'A' Part- XIV : (Miscellaneous B/R & E/M Items (BOQ) (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.)
PILE FOUNDATION
RCC with ready mix concrete(RMC) M30 grade with min 400Kg cement per cum in cast in situ bored pile of any length/any sections complete all as specified and as shown on drg including non destructive integrity test on all pile as per IS 2911 part IV.Note:-(i) Reinforcement will be measured and paid separately under relevant items (ii) The unit rate quoted under this item is deemed to be inclusive of charges for non destructive integrity tests.
RCC with Ready Mix Concrete(RMC) M30 grade in pile cap , grade beam / tie beam of any length/section complete all as specified and shown on drg. Note :- Reinforcement will be measured and paid for separately under relevant items of this Schedule.
CRS/HCRS/CRM TMT bars 10 mm and above as in main reinforcement conforming to IS 1786 as in piles including cutting, bending, welding, tying, assembling, placing, maintaining in position the reinforcement cages complete all specified and as directed.
CRS/HCRS/CRM TMT bars as in reinforcement 10mm dia and over for grade beams/tie beams and pile caps all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
CRS/HCRS/CRM TMT bars in reinforcement 5 mm dia and over up to and including 16mm dia conforming to IS-1786 as in Helical/stirrups for piles cut to length, bent to shape required, and binding with 0.9mm dia MS annealed wire or welding .
CRS/HCRS/CRM TMT bars 5mm dia and over upto and including 10mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and shown on drgs as in stirrups of grade beams and pile caps.
Plain Cement Concrete (1:4:8) type D2 using 40mm graded stone aggregate for concrete layer below pile caps/ grade beams and foundation complete all as specified and shown on drgs.
Formwork to sides of pile caps, grade beams and tie beams for rough finished flat concrete surfaces all as specified .
Initial Load testingl (Vertical Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 600 mm dia cast in situ pile.
Initial Load testing (Vertical Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 500 mm dia cast in situ pile.
Initial Load testingl (Lateral Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 600 mm dia cast in situ pile.
Initial Load testing (Lateral Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 500 mm dia cast in situ pile.
Routine Load testingl (Vertical Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 600 mm dia cast in situ pile.
Routine Load testing (Vertical Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 500 mm dia cast in situ pile.
Routine Load testingl (Lateral Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 600 mm dia cast in situ pile.
Routine Load testing (Lateral Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 500 mm dia cast in situ pile.
Conducting standard penetration test all as per IS-2131 at levels and locations as directed for 600/500 mm dia cast in situ bored piles all as specified.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep or area not exceeding 10 sqm on plan in any type of soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/grade beams/ raft foundation etc all as specified and shown on drawings.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m deep and not exceeding 3 mtr depth or area not exceeding 10 sqm on plan in any type of soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/grade beams/ raft foundation etc all as specified and shown on drawings.
Excavation over areas not exceeding 1.5m deep in any type of soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/grade beams/ raft foundation etc all as specified and shown on drawings.
Excavation over areas exceeding 1.5m deep and not exceeding 3m deep in any type of soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/grade beams/ raft foundation etc all as specified and shown on drawings.
Excavation over areas exceeding 3m deep and not exceeding 4.5m deep in any type of soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/grade beams/ raft foundation etc all as specified and shown on drawings.
Returning filling in around pile cap, plinth beams, raft foundation etc using excavated soil including spreading levelling and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removal of surplus soil to a distance exceeding 1.5 Km and not exc. 5 Km deposited as directed.
Demolition of cement concrete (un-reinforced) of any discription and in any position not otherwise specifically provided for all as directed.
Demolition of cement concrete (Reinforced) of any discription and in any position not otherwise specifically provided for (Reinforced cut as required to facilitate demolition) all as directed.
Removal of demolished materials/ RCC debris etc to a distance exceeding 1.5 Km and not exc. 5 Km and deposited as directed.
INTERNAL WATER SUPPLY Chromium plated long body bib cock with wall flange and aerator of Make Jaquar (ESSCO), Cat No MQT-512KN or equivalent in other approved makes as specified
Chromium plated short body bib cock of Make Jaquar (ESSCO), Cat No MQT-511KN or equivalent in other approved makes as specified
Chromium plated brass concealed stop cock heavy body with cap size 20mm of Make Jaquar (ESSCO), Cat No MQT-514CKN or equivalent in other approved makes as specified
Chromium plated brass Angle valve (Angle stop cock) of Make Jaquar (ESSCO), Cat No MQT-526NKN or equivalent in other approved makes as specified
INTERNAL ELECTRIC SUPPLY Ceiling fan 1400mm sweep copper wound having Min air delivery 245 CFM with service value not less that 4.50 with brushless direct current motor (BLDC) as per IS 374:2019 including fixing of down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sq mm from connector to fan complete all as specified
Exhaust fan made of sturdy engineering plastic complete with louvers shutter voltage 230V, 50 Hz, RPM 1200 of sweep 250mm complete including making necessary provisions for mounting on walls all as specified and directed.
LED Tube light 1X22 Watt 4' universal battern type with and including connecting 3 core 1sqmm PVC insulated multistranded copper conductor's sleeve color matching to fitting and connecting up complete all as specified and directed at site
LED study light wall type fixture made of polycorbnate suitable for 3/5/7/9 W LED lamp including connecting 3 core 1sqmm PVC insulated multistranded copper conductor's sleeve color matching to fitting and connecting up complete all as specified and directed at site
LED light 1X10 Watt 2' with and including connecting 3 core 1.0 Sqmm PVC insulated multistranded copper conductor color of sleeve matching to fitting and connecting up complete all as specified and directed at site
S&F LED light fitting 600mm x 600mm, 35/36 watt, 220 V AC surface/recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. at site.
Building LED security light 1x35W new generation energy saving and environmental friendly long life made of pressure die cast alluminium housing with hogh power LED as lighting source and lens embded PC cover having TOP OPENING seperade driver compartment with IP66 protection and impact resistance of IK 07 complete with and including wall mounted bracket fabricated out of 40mm GI pipe light grade bend to shape1.5 mtr long and two nos wall mounting clamps using 25x4mm thick MS strip bend to shape and welded with pipe to form solid structure and one run of 1sqmm PVC insulated multistranded copper cunductor wire conecting pvc terminal to fitting complete all as specified and directed
MCCB DB VTPN 4 way double door 415 Volts with provision for MCCB as incomer and SP/TP MCBs as out going with IP 43 protection, door earthing, isolated neutral bar, mechanical impact strength IK 09 including cement spill protector. Make Crabtree Cat No DCDLVDCBGSTE04 or equivalent in other approved makes as specified
MCCB 4 pole of current rating capacity 63 Amps with breaking capacity Icu AC 16kA @ 415V AC 50 Hz conforming to IS/IEC 60947-2 & EN 60947-2 of thermal magnetic release with ON-TRIP-OFF indication. Make Legrand Cat No 420055 or equivalent in other approved makes as specified
Exhaust fan made of sturdy engineering plastic complete with louvers shutter voltage 230V, 50 Hz, RPM 1200 of sweep 450mm complete including making necessary provisions for mounting on walls all as specified and directed.
LED bulb 7 W, polycarbonate body 700 lumen all as specified and directed
EXTERNAL WATER SUPPLY Cutting existing 200 mm bore CI water mains fresh water line and inserting Tee of size 200x200x100 mm dia for taking branch connection including fittings and lead joints complete all as specified
Ductile Iron, single socketed pipe including specials, Class K-9 fittings, 100 mm (4") dia including cost of flange, leather gasket, bolts,nuts, washers, etc. complete all as specified
Valve chamber of internal size 1.20 m X 1.20 m X 1.20 m (internal dimentions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation , brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to both internal and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The estimated cost includes all earthwork and connected items.
Supply, installing, testing and commissioning of electrically driven centrifugal Pump set as per specification, motor TEFC type, 2900 rpm, 420 V, 50 Hz, 3 ph, class 'F' insulation, IP 55 protection, not less than 10HP, starting on suitable Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 450 LPM at 55 mtr head inclusive of suitable rated 3 ph starter as recommented by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals including foot valve of suitable size of 80mm of suction pipe, air release cock, priming valve complete all as specified and directed by the Engineer-in-charge.
EXTERNAL ELECTRIC SUPPLY Supply,laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of size 185 Sq.mm 3 core (Earthed system) complete all as specified
Supply,laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 Sq.mm 3.5 core complete all as specified
Supply,laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 Sq.mm 3.5 core complete all as specified
Supply,laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sq.mm 3.5 core complete all as specified
Supply,laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sq.mm 4 core (Street Light) complete all as specified
Supply, install, testing and commissioning of factory made and CPRI tested out door type feeder pllar box suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating of suitable Amps for phases and suitable Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.15mm CRCA sheet duly powder coated after seven tank process and pedestal of size 40 x 40 x 5 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties including marking of locations which are required to be feed on each incoming and outgoing MCCB in each pannel. ( Location LTP No 1 of schematic plan)
Item No 69 (Contd...) INCOMING (a) MCCB TPN 400 Amps 50 KA -01 Nos Incoming. (b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-300 Amps with and including CTs OUTGOING (a) MCCB TPN 200 Amps 50 KA- For building panel incomer (b) MCCB TPN 200 Amps , 18 KA - 03 Nos for Emergency panel,capacitor bank and spare (c) Internal wiring of panel with stranded copper cable of suitable size (d) Neon phase indicating lamp(Set of three)-01 Nos (e) Stenceling of pannel board including marking of distribuitions
Supply, install, testing and commissioning of factory made and CPRI tested Outdoor type pedestal mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating of suitable Amps for phases and suitable Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.15 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 40 x 40 x 5 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties including marking of locations which are required to be feed on each incoming and outgoing MCCB in each pannel. :-(Location: LTP No.2 (DG AMF Panel) of Schematic plan)
Item No 71 (Contd...) INCOMINGS (a) MCCB 415 Volts, 200 Amps TPN ,18 KA (Incoming) (b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-300 Amps with and including CTs-01 No OUTGOING (a) MCCB 415 Volts, 160 A TPN - 02 Nos (for fire fighting panel and spare) (b) MCB 415 Volts 63 A TPN - 03 Nos ( for 02 nos 8 passenger lift and 1 No fresh water pannel) (c) MCB 415 Volts 25 A SPN - 01 No ( for aviation obstruction light,security light and stair case lightning) (d) Internal wiring of panel with stranded copper cable of suitable size (e) Neon phase indicating lamp(Set of three)-01 Nos (f) Stenceling of pannel board including marking of distribuitions
Supply, install, testing and commissioning of factory made and CPRI tested indoor type pedestal mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 150 Amps for phases and 150 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2.0 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 40 x 40 x 5 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties including marking of locations which are required to be feed on each incoming and outgoing MCCB in each pannel. :-(Location: LTP No (Lift panel1 and lift panel 2)
Item No 73 (Contd...) INCOMINGS (a) MCCB TPN 63 Amps 16 KA -01 No (Incoming) (b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-100 Amps with and including CTs-01 No OUTGOING (a) RCCB 40 Amps 4 pole , 415 Volts, 100 mA - 01 No (Outgoing ) (b) MCB SPN 10 Amps - 01 No (c) Digital volt meter 0-500 Volts-01 No (d) Digital Ampere meter 0-300 Amps with and including CTs (e) Neon phase indicating lamp(Set of three)-01 Nos (f) Stenceling of pannel board including marking of distribuitions
Supply, install, testing and commissioning of factory made and CPRI tested Outdoor type pedestal mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 300 Amps for phases and 300 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.15 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties including marking of locations which are required to be feed on each incoming and outgoing MCCB in each pannel.:-(Location: LTP No - 3 Building panel)
Item No 75 (Contd...) INCOMINGS (a) MCCB 415 Volts, 200 Amps TPN , 50 Ka (b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-100 Amps with and including CTs-01 No OUTGOING (a) MCB TPN 40 Amps - 10 Nos( For G+9 and one spare) (b)MCB SPN 32 Amps - 02 Nos (c)Digital volt meter 0-500 Volts-01 (d)Digital Ampere meter 0-300 Amps with and including CTs (e) Neon phase indicating lamp(Set of three)-01 Nos (f) Stenceling of pannel board including marking of distribuitions
Supply, install, testing and commissioning of factory made and CPRI tested indoor type pedestal mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 200 Amps for phases and 200 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2.0 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties including marking of locations which are required to be feed on each incoming and outgoing MCCB in each pannel.:-(Location: (LTP-4 Water supply panel)
Item No 77 (Contd...) INCOMINGS (a) MCCB 415 Volts, TPN 63 Amps 18 kA - 01 No (Incoming) (b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-100 Amps with and including CTs-01 No OUTGOING (a) MCB TP 32 Amps 15 kA - 02 Nos (b) MCB SPN 16 Amps 15 kA - 01 No (c) DOL starter for 10 HP pump- 2Nos (d ) Provision for fixing 02 Nos star delta starters. (e) Digital volt meter 0-500 Volts-01 (f) Digital Ampere meter 0-300 Amps with and including CTs (g) Neon phase indicating lamp(Set of three)-01 Nos (h) Stenceling of pannel board including marking of distribuitions
Item No 79 (Contd...) INCOMINGS (a) MCCB 415 Volts, TPN 160 Amps 18 kA - 01 No (Incoming) (b) MCCB 415 Volts, 4 P 125 AMPS 18 KA - 01 No (Outgoing) (c) Digital volt meter 0-500 Volts-01 (d) Digital Ampere meter 0-100 Amps with and including CTs-01 No OUTGOING (a) MCB TP 32 Amps 15 kA - 02 Nos (b) MCB SPN 16 Amps 15 kA - 01 No (c ) Provision for fixing 02 Nos star delta starters. (d) Digital volt meter 0-500 Volts-01 (e) Digital Ampere meter 0-300 Amps with and including CTs (f) Neon phase indicating lamp(Set of three)-01 Nos (g) Stenceling of pannel board including marking of distribuitions (h)Satr Delta starter independent compartment alongwith overload, short circuit/single phasing prevention Phase sequence protention, over voltage under voltage LED indigating and trip option for 90 HP pumps - 1 Nos (j)DOL starters for 7.5 HP pump- 1 Nos
Supply and fix MD-XL Double metalized paper (Extra Low Loss) Capacitor for 3 phase,440 V, 50 Hz system for permissible non-linear load 20 % Automatic Power Factor Correction (APFC) Panel capacity 50 KVAR outdoor type with protection of CRCA sheet.
Supply and installation of HT 11 KV, 3 phase, 50 Hz totally enclosed metal clad switchgear complete with Vacuum circuit breaker having rupturing capacity 350 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 11 KV 630 Amps, 21 KA Motor operated compact outdoor both side extensible, non drawout type (+C+) (01 No Load break Switch (OD) as incomer SAFEPLUS compact gas insulated Ring Main Unit (RMU), all live parts enclosed in a welded stainless steel tank of IP 67 class of protection including coupling accessories with battery and battery charger, foundation and transporatation all as specified and as directed
Supply and installation of HT 11 KV, 3 phase, 50 cycles totally enclosed metal clad switchgear complete with Vacuum circuit breaker outdoor type having rupturing capacity upto 350 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 630 Amp , 21 KA Motor operated compact indoor both side extensible, non drawout type (+CV+) (01 No Load break Switch OD incomer and 1 no fixed type motor operated Vaccum circuit breaker( VL) outgoing) safeplus compact gas insulated Ring Main Unit (RMU), all live parts enclosed in a welded stainless steel tank of IP 67 class of protection including coupling accessories with battery and battery charge , foundation and transporatation all as specified and as directed.(The RMU will be installed at propsed powerhouse near project buildings)
Supply and installation of Transformer step down, indoor type, copper wound, oil cooled complete with standard fittings HT 11/0.433 KV, 3 phase, 4 wire with off load tappings on HT side to vary secondary voltage within limit +/- 5% in step of +/- 2.5%. ONAN all as per IS :1180 of capacity 250 KVA duly initial oil filled up to normal level with following accessories and functions alongwith foundation as per the recommendations of the manufacturer. (i) No load loss as per standard (subject to IS tolerance) (ii) Full load loss as per standard (subject to IS tolerance) (iii)Impedance is 4.75% (subject to IS tolerance) (iv) Vector group is Dyn 11 (v) Silica gel breather (vi) conservator with plain oil gauge and oil drain plug (vii) Top filter valve (viii) Bottom filter cum drain valve (ix) shut off valve between buchholz relay and conservator (x) Off circult tap changer (xi) Rating and dilagramme plate (xii) Earthing terminals (xiii) Thermometer pockets (ivx) Lifting lugs (xv) Air relief plug (xvi) Jacking pads (xvi) Bi-directional rollers (xviii) Explosion vent with single diaphragm (xix) Detachable radiators (xx) Inspection cover (xxi) Danger notice board (xxii) cable entry box. Note :- Trasformer incoming/outgoing HT/LT cable to be drawn through 100 mm GI medium grade pipe with supporitng structure.
Supply and fix cable jointing kit for 11KV grade cable ( Earthed) for outdoor termination,heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, AL conductor cable of size 185 Sq.mm complete all as specified
Supply and fixing of name boards made out of acrylic type material thickness of sheet 5mm for pump house and power hosue, external water supply and external extric supply boards with name of project and date of installation and capacity of pumpsets/ electrical installations and distribution flow chart including base frame fixed on wall complete as directed.
Supply and fix steel tubular swaged poles type 410SP-31 (9 meter long) swan neck type complete with CI base plate and finial and single swan neck, including foundation and coping complete all as specified
Supply and fix street light fitting pressure die cast aluminium housing with heat resistant toughened glass IP 66 protection of 35 watt, 230 V, LED street light fitting complete with LED lights, inbuilt erlectronic driver, minimum 10 KV surge protection, nmumber of LED 44 with clear acrylic cover accessories pre wired and fixing accessories ie nut bolt washers, Flat iron strips, Gi pipe etc. . complete all as specified.
Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimum size 225 x 295 x 122 mm including suitable Cable connecting terminals, cable lugs, including provn of one No MCB SP 6 Amps for operating the streetlight fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge.
Supply and fix time switches astro type having longitude and latitude of indian cities in memory 250 V Single phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified
S&F HT Cable route marker of Cast Iron type Circle 100 dia
S&F LT Cable route marker of Cast Iron type Circle 100 dia
S&F blue metal stones for Electric installations of size 20 mm
S&F Chain Link fencing with angle iron bar type over perimeter of electric installation area 10X 4 Square meter by 0.5 meter PCC foundation all around inculding gate all necessary connections complete alll as specified by Engineer-in-Charge
FIRE FIGHTING Supply and Install Diesel engine driven fire pump horizontal end suction, centrifugal type, CI casing and bronze impeller stainless steel shaft , mounted on heavy duty bearings suitable forcontinuous operation with 'range ofoperation' 0 % to 150 % of rated capacity for 440 V , 3 phase, 50 Hz AC supply suitable for delivering 2280 LPM,90 meter head,1800 RPM including diesel tank of capacity 50 ltrs for 90 HP diesel driven pump with common base frame (fabricated mild steel chanel frame or cast iron type) Placed on RCC (1:2:4) including foundation bolts and nuts), including footvalve of size 150 mm, air release cock, priming valve. Insulated copper cable from pump to pannel through PVC conduit.
Supply and Install Electric driven fire pump horizontal end suction, centrifugal type, CI casing and bronze impeller stainless steel shaft , mounted on heavy duty bearings suitable forcontinuous operation with 'range ofoperation' 0 % to 150 % of rated capacity for 440 V , 3 phase, 50 Hz AC supply suitable for delivering 2280 LPM,90 meter head,2900 RPM 90 HP pump with common base frame (Fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation bolts and nuts), including footvalve of size 150 mm, air release cock, priming valve. Insulated copper cable from pump to panel through PVC conduit.
Supply and Install Electric Driven Jockey pump Jockey pump horizontal end suction centrifugal type Confirming to IS- 12469:1988 with CI casing , bronze impeller andstainless steel shaft mounted on heavy duty bearings suitable for automatic operation with nonover loading power characteristics for frequent start / stop operations for 440 V , 3 phase, 50 Hz 90 m head 180 LPM discharge RPM 20 HP pump with common base frame (Fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation bolts and nuts), including footvalve of size 100 mm, air release cock, priming valve. Insulated copper cable from pump to panel through PVC conduit.
Supply and fix landing valve (internal hydrant) double headed gunmetal bearing ISI mark grade 63 mm female instantaneous outlet compelte confirming to IS 5290 with PVC blank cap and chain and having suitable flanges for 100 mm/80 mm dia wet riser/ downcomer
S & F first aid hose reel drum swinging wall mounted type comprising rubber hose 20mm dia 30m long high pressure double braided bearing IS-5132 type 'A' 5 mm bore PVC shut off nozzle and 25mm gunmetal inlet valve conforming to IS-884 and connected to wet riser/ downcomer. note:- (i) Hose reel shall be type 'A', wall mounting type, swinging complete with 19 mm. bore, high pressure braided rubber hose. 36 m long, 6 mm bore shut off nozzle and 25 mm inlet valve, IS: 884 mark. (ii) The material of construction for various components shall be as per IS:884 -1985. (iii)Piping connecting for the hose reel shall be taken from the main riser above the landing valve
Supply and provide reinforced rubber cotton synthetic fibre circular woven jacketted fire delivery hose 63 mm dia treated against rot / mystex having 38KG/cm2 working pressure bearing IS-636 type "A" 15 Mtrs length with male and female coupling confirming to IS-903. Note:- Hoses shall be of Synthetic fibre, circular woven jacketed, treated against rot, Working Pressure 12 kg/sq cm. Burst pressure, 36 kg/sq cm .Coupling shall be male and female parts, gunmetal, 63 mm. (2 1/2") size, heavy quality bearing conforming to IS.903 with IS Mark and TAC approval.
Supply, connect, joint and lay MS pipe (ERW) heavy duty ISI marked with all fittings of size 100 mm dia with flanged ends and including flanges, leather gaskets, heavy duty bolts, nuts, washers etc, laid in trenches,floors, fixed on walls/floors/roof ete including fixing with clamps on wall for the wet riser including painting with approved synthetic enamel paint all as specified and directed by Engr-in-charge.
Supply and lay pipe ductile Iron,flanged type including specials, Class "K-9", 150 mm (6") dia
Supplying , fixing, testing and commissioning of butterfly valve PN 1.6, bronze/ Gun metal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095 of size 100mm .
Supply and fix Gun metal fire brigade inlet connectin (suction collecting head) consisting of four nos 63 mm dia instantaneous type male coupling with built in check valves and 150 mm dia sluice valve (one no 150 mm dia NRV), AND 150 mm dia flanged outlet complete with all accessories
Supply and fix Air cushioning tank (Air vessel) 250 mm dia X 1000 mm high with dished top, made of minimum 6 mm thick MS pipe/plate complete with 20 mm dia.Brass air valve (ball type) , 20 mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories complete
Supply and fix Automatic air release valve 50 mm dia suitable for domestic water with 50 mm gun metal stop valve complete
Supply and fix mild steel class 'C' diesel pump exhaust pipe 150 mm dia with one layer of 10 mm thick asbestos rope insulation and including all fitting clamp/Structural steel supports complete
Supply and fix foot valve conforming to IS 4038 150 mm (6") dia cast iron
Supply and fix valve,reflux,with by-pass arrangement , 150 mm (6")dia
Supply and fix valve,reflux,with by-pass arrangement , 100 mm (4")dia
Supply and fix valve,reflux,with by-pass arrangement , 80 mm (3")dia
Supply installation testing and commissioning of 32 Bit Microprocessor based Intelligent Addressable 2 Loop Main Fire Alarm Panel expandable to 10 Loops having loop capacity of minimum 250 devices per loop with 4000 eventplus 1000 alarm log history events, QWERTY keypad for programming with inbuilt panel display.The panel shall be networkable over copper wire for 900m with a network speed of minimum 312 kbps. The Intelligent panel shall be able to give pin point location of all fire/fault conditions. The panel shall be complete with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network capable of supervising all the speaker circuits with adequate zone control and accessories. The Voice evacuation amplifier shall be of 70W and shall have automatic battery charger available with it. The fire alarm panel and all accessories shall be UL Listed and FM approved. The Fire alarm control panel shall be provided with 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during an emergency conditions as required. Approval standards UL/ VdS / FM MAKE: NOTIFIER/HONEYWELL/EDWARDS/SIEMENS
Supply of Analog addressable type active loop repeater (Loop power/external power) Fire terminal with inbuilt turbo isolator, Backlit LCD Display 6 x40 characters display, having controls for reset, mute,accept, silence alarms and self test, with programmable free keys and duly approved by EN54/LPCB/VDS/FM
LED Emergency exit signage luminaire lit up using regular main supply comes with a unique rechargeable battery capable of emergency backup upto 05 hours.
LED Emergency escape lighting luminaire lit up using regular main supply comes with a unique rechargeable battery capable of emergency backup upto 05 hours.
Supply, installation testing and commissioning of XLPE insulated PVC sheathed FRLS galavanised steel strip or wire (Heavy duty) electric cable with copper coductor of size 1.5 sq.mm, 2 core suitable for working pressure 1100 Volts to IS:7098 and drawn into PVC coduit pipe 20 mm. all as specified and directed.
Supply and provide reinforced rubber cotton synthetic fibre circular woven jacketted fire delivery hose 63 mm dia treated against rot / mystex having 38KG/cm2 working pressure bearing IS-636 type "A" 30 Mtrs length with male and female coupling confirming to IS-903. Note:- Hoses shall be of Synthetic fibre, circular woven jacketed, treated against rot, Working Pressure 12 kg/sq cm. Burst pressure, 36 kg/sq cm .Coupling shall be male and female parts, gunmetal, 63 mm. (2 1/2") size, heavy quality bearing conforming to IS.903 with IS Mark and TAC approval.
Supply installation testing and commissioning of Addressable Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. The Isolator module shall not occupy any address on loop. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The module shall be UL lsited and FM approved. MAKE : NOTIFIER/HONEYWELL/EDWARDS/SIEMENS
Supply installation testing and commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes. The control module shall provide DPDTcontact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The module shall be UL lsited and FM approved. MAKE : NOTIFIER/HONEYWELL/EDWARDS/SIEMENS
Supply installation testing and commissioning of 2W MultiTap (0.25W; 0.5W; 1W; 2W), Ceiling Mount Speakers. The speakers shall be of same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms. The speaker shall be UL lsited. MAKE: NOTIFIER/HONEYWELL/EDWARDS/SIEMENS
Supply,installation,testing and commissioning of Fire Alarm Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of +5 DB, range upto 1000m complete all as specified and as directed by the Engineer-in-Charge. Make:- Notifier/Morley/Cooper/Honeywel or equivalent in other approved make
TELE/ TV SOCKET S&F GI metal flush boxes 2 module complete all as specified
Supply and fix RJ 11 telephone socket 1 module with cover plate complete all as specified
Supply and fix TV socket 1 module with cover plate complete all as specified
M&L Rigid non metallic PVC conduit 20mm dia, medium grade exclusive of boxes (junction/terminal) but inclusive of all Tees,bends,elbows, reducers, bell mouth,bell tube ends and fixing accessories such as couplers,lock nuts,saddles,pipe hooks etc complete all as specified
M&L Rigid non metallic PVC conduit 25mm dia, medium grade exclusive of boxes (junction/terminal) but inclusive of all Tees,bends,elbows,reducers,bell mouth,bell tube ends and fixing accessories such as couplers,lock nuts,saddles,pipe hooks etc complete all as specified
AVIATION OBSTRUCTION LIGHT Supply and fix aviation obstruction LED integral aviation light Comprising of aluminium housing and polycarbonate enclosure with timer switch and one 10A MCB SP 230 Volts fixed in a sheet metyal enclosure.,Contactor MO9 1NO + 1NC contactor, MS Framework complete all as specified
Supply,laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium condutor of size 6.0 sq mm 2 core complete all as specified
WATER COOLER Supply, installation,commissioning of Watercooler fully stainless steel, electric driven single phase having approx storage 40 ltrs and nominal cooling 40 ltrs single phase 230 V AC power supply with all connecting accessories including PCC foundation complete all as specified and directed by engineer in charge.
Supply and fixing Voltage stabilizer for auto operation ,single phase ,naturally air cooled indoor type and designed for input variation between 170V to 280V with out put voltage stablizer at 230V with accuracy with in +/- 2.5% and speed of corrrection 8 volts per second and of capacity 2.0 KVA capacity Make : V-Guard or equivalent
SEWAGE DISPOSAL RCC hume pipe Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft , manhole openings with cover connection etc., complete for 100 users complete.
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 M dia X 3 M effective depth
PREFAB CLOTH DRYING HANGERS Supply and fix wall mounted aluminium anodised cloth drying hanger single unit , 9 feet long consisting of L angle size 31 inches pair at end for 4 Nos alumin ium anodised pipe of outer dia 22mm and inner dia 19.8mm, channel pair one end single pulley and other end double pulley, 4 Nos long and 4 nos short polyester braided rope of 3.5mm dia (plus or minus 0.5mm) required length and other fitting materials like special special lock assembly - 04 Nos, channel mounting scres - 08 Nos, rope end lock - 04 Nos, pipe end cap - 08 Nos and rawl plug - 12 Nos etc complete all as specified and directed. Make ; Easydry or equivalent in other makes as approved by GE.
Item No. 134(Contd...) (a) Stops and openings:- 10 stops/ 10 openings on the same side. (b) The integral dimension of the lift car should be suitable size for the specified load and in accordance with the statutory requirements. (c) The inside car measurement shall be based on lift well dimensions shown on drawings forming part of the Contract. Each lift shall be complete with following accessories & fittings. (i) Double button with 7 segmental display at all floors. (ii) Car opening panel with micro stroke push button with 7 segment digital car position indicator, car direction indicator (iii) Fire exitingusher which provided at main lobby. (iv) Battery operated alarm bell and emergency lift with battery. (v) Voice Synthesizer (vi) Car Chime (vii) Provision of cross flow rectangular (low noise/mild air flow) fan-01 of approved make. (viii) S&F Decorative LED spot light (ix) Provn of emergency intercom system (car machine room-control system) (x) Oveload function, constant indication/buzzer. (xi) 5/15 A power socket & light point at every floor level in the hoist way. (xii) MS Ladder (xiii) 3 Phase power supply & earthing from machine room to all equipment. (xiv) Multi beam full length infra red door sensor (minimum of 32) (xv) Emegency landing device ELD (ARD) (xvi) Extra cores in travelling cable for customer smoke detectors. (xvii) Back ground music speakers.
DG SET Supply and install Static silent Diesel Engine with accoustic enclosure, capable of delivering 50 KW (62.5 KVA), including (AMF panel) Automatic starting on main faiilure control panel water cooled, 415 volts (AC three phase, 4 wire system of supply) , frequency 50 Hz, at power factor 0.80 minimum. The DG set shall consists of a diesel engine coupled to a matching the alternator through flexible coupling and mounted on a common based frame and complete with control panel standardized by the manufacturer, fuel tank with mounting arrangements and with standard fuel pipes for inlet, outlet and return inlet oil arrangements, exhaust pipe, silencer and asbestos rope protection completye and shall be suitable for conditions prevailed at Kochi. (Designed capacity of Diesel engine and alternator shall be worked out by considering all derating factors prevailed at the area to be installed) The foundation of Gen Set shall be as specified by the manufacturer and shall be mounted on a suitable Channel frame structure with anti-vibration pads and including all technical features to comply with latest CPCB guidelines and comprising of followings:-
Item No 136 (Contd...) (i) DIESEL ENGINE (Prime Mover): Diesel Engine 1500 RPM, direct injection, six cylinders, four stroke, confirming to ISO3046/BS5514, water cooled, natuarally turbo charged, capable of giving adequate BHP to drive alternator capable of delivering 50KW(62.5 KVA) at outdoor atmospheric conditions at palluruthy,kochi (Considering all derating factors prevailed in the area). Batteries 12/24 Volts and desired ampere hours (as per manufacturers recommendations), electric battery start, complete with fly wheel and all standard fittings and fixtures as per manufacturer and including suitable panel with tacho meter, lub oil temperature, pressure gauge and frequency meters. The engine shall have self starter, dynamo, FIP, oil pump, fuel electric control panel with mechanical governor (ECPG) and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc. , recommented capacity of fuel tank and first filling of fuel and lub oil and other consumables etc. (ii) ALTERNATOR: Brushless AC alternator, 3 phase, 415 Volts, 4 wire rated for output of 50 KW (62.5 KVA) minimum power factort 0.80, 1500 RPM, IP 23 ptotection class enclosure, insulation class 'H', salient pole, revolving field, single bearing, automatic voltage regulator coupled through flexible coupling with and match the above engine.
Item No 136 (Contd...) (iii) BASE PLATE:- Made of structural steel as per manufacturers recommended design/specifications. (iv) ACOUSTIC ENCLOSURE:- Sheet metal fabricated canopy type, silent enclosure, manufactured on CNC machines as per CPCB norms and shall be powder coated. The enclosure shall be designed for reducing the sound level to 75 DB at a distance of 1 mtr at 75% load under field condition and 70DB at 3 M from Gen Set when DG set is working at full load along with testing performance, labeling certification etc. as laid down in GSR No. 371(E) dt 17 May 2002. (i) Foundation/Plinth/Base shall be provided as per manufacturers recommendations, however minimum 0.50 M space should be available all around the set and height of plinth shall not be less than 0.50 M. (ii) Standard Diesel Engine tank of adequate capacity for running the Gen Set continuously for 12 hours including standard pvc pipes from tank to FIP, overflow pipe from FIP to tank. (v) MISCELLANEOUS:- Tool kit, Operation and maintenance catalogue, spare parts list, overhauling manuals, guarantee cards, test certificate of Engine and alternator etc. shall be provided as per manufacturer standard practice.
COMPREHENSIVE MAINTENANCE OF LIFTS AFTER DEFECT LIABILITY PERIOD
Note :- (a) Replacement of sheeve and steel ropes, if required during this period, will be carried out by the contractor but material shall be provided by the department for fixing only. (b) :- The comprehensive maintenance shall be done through OEM of the lift. (c) :- The Contractor shall enter into an MOU (Memorandum of Understanding) with the OEM or their authorised agency for maintenance of the lift. The above comprehensive AMC certificate shall be provided by the Contractor in favour of GE (NW) before commencement of work, after acceptance of CA. (d) :- The parts shall be genuine and shall be from original equipment manufacturer (OEM) and shall be approved by GE. (e) :- All stainless steel parts such as lift car enclosure, opening doors, jamps, cills etc shall be thoroughly cleaned to remove rust, stains etc with suitable solution. The Contrator shall also be clean and properly maintain machine rooms, machineries and lift well as directed by EIC. The rates quoted for respective items shall be deemed to include for the same. (f) :- No spare parts and consumables shall be supplied by the Department. (g) :- The rate of maintenance, service and repair including all the material and labour for the satisfactory functioning of the lifts.
All as per Item No 140 here-in-before but for the second year after completion of defect laibility period.
All as per Item No 140 here-in-before but for the third year after completion of defect laibility period.
VIJAY CONSTRUCTIONS
A2Z ENGINEERS AND PILE FOUNDATIONS
PUSHKARRAJ CONSTRUCTION PRIVATE LIMITED
RKEC Projects Limited
FUTURE ONE FACILITY MANAGEMENT
S.N. Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid