Loading…
Loading…
Tender Value
₹20.7 L
EMD Value
₹50,000
Closing Date
9 Sept 2024, 4:00 pmClosed
ASSISTANT ENGINEER
O/o The Assistant Engineer, LID and EW Section, Ottapalam Municipality.
ELECTRICAL WORKS
2024_LSGD_688024_1
LSGD/CELSGD/TR/35228/2024
Open Tender
Electrical Works
Item Rate
180 days
OTTAPALAM
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
Yes
₹50,000
Yes
19 Oct 2024
30 Aug 2024
11 Sept 2024
30 Aug 2024
9 Sept 2024
30 Aug 2024
Amount
AMC for street lights
OD49143/2024-2025:Supply and renewing 1.50sqmm PVC insulated and PVC sheathed twin core Aluminium WP cable for street light fitting and holders including giving connection etc. complete
OD51324/2024-2025:Supply, installation, testing and commissioning of automatic on-off board using LDR including giving connection and all charges etc as required
OD49144/2024-2025:Supplying and renewing 200mm aluminium shade with new one including labour and conveyance charges.
OD49145/2024-2025:Supplying and renewing brass pendent holder with new one including labour and conveyance charges.
OD49146/2024-2025:Supplying and renewing 50w LED bulb B22 base with new one including labour and conveyance charges.
OD49162/2024-2025:Supplying and renewing 44w LED bulb B22 base with new one including labour and conveyance charges.
OD49147/2024-2025:Supplying and renewing 25w LED bulb B22 base with new one including labour and conveyance charges.
OD49148/2024-2025:Supplying and renewing 24w LED bulb B22 base with new one including labour and conveyance charges.
OD49150/2024-2025:Dismantling and renewing the defective LED Panel/PCB suitable for 24w/25W LED fittings and giving necessary connections including all charges.
OD49151/2024-2025:Dismantling and renewing the defective LED drive suitable for 44w/50W LED fittings and giving necessary connections including all charges.
OD49152/2024-2025:Dismantling the existing pendent holder,24W/ 25W LED bulb form the electric post repairing and replacing the bulb etc. on existing pole and giving connection.
OD49153/2024-2025:Labour charges for dismantling 22W CFL Street light fittings from the existing pole and cleaning, rewiring/ repairing & refitting the same on existing pole and giving connection.
OD49154/2024-2025:Dismantling the existing 24w/25w/40w/70w LED street light fitting from the KSEB electric post without any damage, repairing and refixing in the same position including labour and conveyance.
OD49155/2024-2025:Labour charges for dismantling 1x40w/2x40w fluorescent tube Street light fittings from the existing pole and cleaning, rewiring/ repairing & refitting the same on existing pole and giving connection.
OD55378/2024-2025:Maintenance of 100w flood light by disconnecting and lowering from the mini mast pole, repair/replace the drive unit and PCB, fixing back on top ring of 9m mini mast pole, giving connections, testing and commissioning etc. complete
OD55379/2024-2025:Maintenance of of 120/150w flood light by disconnecting and lowering from the mini mast pole, repair/replace the drive unit/PCB fixing back on top ring of 9metre pole, giving connections, testing and commissioning etc. complete
OD55381/2024-2025:Maintenance of 180/200w flood light by disconnecting from the ring of mini mast pole and lowering, repair/replace the drive unit/PCB, fixing back on top of 9metre pole ring, giving connections, testing and commissioning etc. complete
OD55382/2024-2025:Maintenance of the motor for the rising and lowering of flood lights and ring on high mast light, by disconnecting, lowering from the pole, repair/replace the motor, fixing back, giving connections, testing and commissioning etc. complete
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.10:Supply Conveyance, installation, testing and commissioning of 180W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.11:Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
OD49166/2024-2025:Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board.
OD49167/2024-2025:Supply and Fixing 32A Fuse base and fuse link in the existing panel board and giving connection including all labour charges.
OD49168/2024-2025:Supplying and Fixing 24 Hour timer for operating ON-OFF function in the existing MCB DB/enclosure with connection testing commissioning etc as required.
OD49169/2024-2025:Supplying and fixing 32A 2Pole AC1 Power contractor in the existing MCB DB/enclosure complete with connections, testing and commissioning etc.as required.
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
OD51414/2024-2025:Supply & installation of dust and vermin proof, 1 Phase Sintex Meter Board (GSMB- 3525 (350x250x150) including providing and fixing 32 A HRC Fuse Base with HRC Fuse link ,32 A neutral link and to fix KSEB meters, etc. as required including fixing it on wall, making good the damages color washing etc. as required.
OD51415/2024-2025:Supply & installation of dust and vermin proof, 3 Phase Sintex Meter Board( GS-MB- 5628 (515 x 240 x145) including providing and fixing 3 Nos. 32/40 A HRC Fuse Base with HRC Fuse link ,32/40 A neutral link and to fix KSEB meters, etc as required including fixing it on wall, making good the damages color washing etc.as required.
ARUN.C.S
Bidder Name
RAMAN.V
ARUN.C.S
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1071154.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .