Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹2.4 L+₹47,102 (24.5%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹2.4 L+₹49,235 (25.7%)Rejected-Finance 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹2.4 L+₹50,729 (26.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹2.4 L+₹51,898 (27.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
7 Nov 2024, 6:00 pmClosed
AGE (I) Dharamshala
AGE (I) Dharamshala
Repair, replacement of geysers, ceiling fans, exhaust fans, summer appliances and other connected works at Charri Camp and Mil Stn Dharamshala.
2024_MES_679899_1
AGE (I)/DSL-39/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
MIL STN Dharamshala
As per NIT
8 documents required · 8 mandatory
₹500
AGE (I) Dharamshala
₹10,000
Yes
10 Mar 2025
17 Oct 2024
9 Nov 2024
17 Oct 2024
7 Nov 2024
31 Oct 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Material and labour for point wiring with 1.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheating FRLS electric cable 1100 volts cable in and including PVC casing and caping of suitable size (as per conductor run) with all fittings such as bend/corners/ accessories and including PVC insulated electric cable 1100 volts 1.5 Sqmm (multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly in existing CI/wooden box covered with 3 mm thick plastic laminated sheet for one light point/ fan/exhaust fan point/ bell point etc controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge. Note : i) New Sunken boxes wherever required shall be measured paid separately. ii) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost
All as per serial item No 2 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
M&L for switch socket combination 2 in 1, 5 Amp and 15 Amp flush type all as specified and directed.
M&L for switch piano flush type single pole one way 5/6 Amp
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
Taking down exhaust fans 250/ 300/ 380/ 450 mm sweep, and then properly cleaning and greasing of bearings after opening of the fan including replacement of unserviceable parts, reassembling and reconnecting of exhaust fan all as directed. Note: - Spare parts will be measured and paid separately at 'supply only rates'.
Supply only ball bearing of exhaust fans of any size and type all as per site requirement including greasing, all as specified. Make: SKF/NBC/ABC
Material and labour for rewinding of exhaust fan of 225 to 300 mm sweep complete with super enameled insulated copper wire of appropriate size , including all winding, insulating material and impregnation of insulating varnish as per detail given below of any make, type, model including transportation from AGE E/M store yard to site of rewinding complete, all as directed.
All as per item No. 09 above but exhaust fan of 450 mm sweep.
Painting of exhaust fans after due preparation of surface 225/300/380/ 450 mm sweep complete at site with super enamel synthetic paint of colour as per old one by spray gun including filling cavities with filler, two coats after cleaning all dust, grease, smoke spots etc all as directed.
Taking down carefully from wall after unscrewing nut/bolts geyser 50/35/25 Ltr capacity and opening the same for taking out internal tank, syphon assembley etc and reassembling and refixing after repair all as specified and as directed by Engr-in-Charge. Note: Spares shall me measured and paid sepratley under respective items of Sch.
Supply only heating unit (element) ISI marked of 1500 watts triangular shape rating as required at site including rubber washers complete, all as specified and as directed. (As per sample) Make : Umpire/Wondercool/Ditz/ Toshiba/jRacold
All as per Serial item No 15 above but circular shape, all as specified and as directed. (As per sample) Make : Umpire/Wondercool/Ditz/ Toshiba/Racold
Supply and replacement internal steel tank of geyser 25 ltr capacity complete with syphon –assembly, 1.5 kw element , rubber gasket , thermostat switch , all as specified and directed . The tank shall be tested at site and shall be able to with stand the requisite pressure. Necessary testing equipment shall be arranged by the contractor .
Supply and replacement internal steel tank of geyser 50/35 ltr capacity complete with syphon –assembly, 1.5 kw element , rubber gasket , thermostat switch , all as specified and directed ., The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor .
Supply and replace PVC connection 15mm dia complete with brass flair nuts at both ends. ( ISI marked and suitable for hot water supply upto 100 degree celcius .)
Supply and fixing anchor bolt 12mmX100mm long complete all as spd and directed (Note:- Anchor bolt shall be grouted with hammer drill only)
Supply only ISI marked thermostat range 0°-75°C for the geysers of 25 to 50 Liters capacities complete, all as specified and as directed. (As per sample)
Supply for 15mm stop valve CP fancy type,cast copper alloy,screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe unions and suitable complete all as specified.
Supply only non return valve 15mm dia cast copper alloy ISI mark complete all as specified and as directed by Engineer-in-charge
Cleaning / scrapping of old paint/dust and painting of geysers of 25/35/50 litres capacity at site/ stores with two coat of super enameled painting by spray complete, all as specified and as directed.
Supply and fixing mild steel galvanised iron water tubing 15mm bore with screwed & socket joints, medium grade, in short lenghts, with and including all fittings such as sockets,bends,elbow,unions,tees diminishing pieces etc, fixed to wall or ceiling or in floor complete all as specified and directed.
Supply and fixing sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar, including taking down the existing and making good distrubed surface, all as specified.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of current carrying capacity SP 5 to 32 Amp MCB complete with connection testing and commissioning.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of current carrying capacity SPN 32 Amp MCB complete with connection testing and commissioning.
Supply and fixing (in replacement) Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 A complete all as specified and as directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 10sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apartincluding 4mm suspension wire, one twin core cable flat or circular. Make : Polycab or equivalent.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing (in replacement) PVC body Exhaust fan 200/250 mm sweep, 5 star rating, 230 V AC, copper binding, blades, frame and, louvers with suitable size of copper wire for connection ceilng rose to Exhaust fan including making good surface and as directed.
Material and labour for rewinding of ceiling fan motor 1200 mm sweep any make with super enameled copper winding wire of gauge as per existing including cutting and getting out old US winding, sleeve work, varnishing with E class insulation varnish , threading ,connections with twin core copper flexible wire of size 0.0076mm of length not more than one mtr with each fan complete all as specified and directed. Material to be used as per ISI marked. (i) Fixing of repaired fan in any location of cantt area shall be contractors responsibility at his own arrangement of transport and Tand P (ii) Old burnt wire will be contractors property and necessary credit shall be recovered as per sch of credit attached .)
Supply only ball bearing of ceiling fans of any size and type all as per site requirement including greasing, all as specified. Make: SKF/NBC/ABC
Supply only capacitor of size 2.5 MFD for ceiling fan all as directed and specified.
Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. (M & L)
Supply and fixing LED bldg security light 15 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing (in repair/replacement) decorative wall mounting fixture, in durable plastic body & designer mesh in gold finish suitbale for 9 W lamps, three core flexible copper conductor cable, 9 W LED buld all as specified and as directed. Make- HPL, Bajaj, Havells, CG etc.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
KONARK ENTERPRISES (BID ID -3156710)
VIRAT CONSTRUCTIONS (BID ID -3159430)
M/S MALHI CONSTRUCTIONS (BID ID -3159461)
ess are electricals and electronic (BID ID -3160176)
JAI DURGA CONSTRUCTION CO (BID ID -3159895)
smc engineering company (BID ID -3159632)
ABHAY ELECTRICAL (BID ID -3160035)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .