Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹40.9 L+₹1.3 L (3.18%)Rejected-Finance 0 BEECHPARA DANGAURA MAHENDRAGARH MANENDRAGARH CHIRMIRI BHARATPUR CHHATTISGARH 497442 | KOREA | CHHATTISGARH | 497442 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹41.8 L+₹2.1 L (5.38%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹44.2 L+₹4.6 L (11.5%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
14 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (A) Central Jodhpur
GE (A) Central Multan Line Army Area Jodhpur
SPL REPAIR OF SEWAGE LINE IN UNIT AREA OF WEU AND TOILETS IN BLDG NO 1242 1246 1252 1253 1255 1256 AND 1263 IN ARMY AREA AT AGE BR AREA I UNDER GE ARMY CENTRAL JODHPUR (9060/E8)
2021_MES_487297_1
GE/J/A- OF 2021-22 (9060/E8)
Open Tender
Civil Works
Item Rate
180 days
GE (A) Central Multan Line Army Area Jodhpur
SPL REPAIR OF SEWAGE LINE IN UNIT AREA OF WEU AND TOILETS IN BLDG NO 1242 1246 1252 1253 1255 1256 AND 1263 IN ARMY AREA AT AGE BR AREA I UNDER GE ARMY CENTRAL JODHPUR (9060/E8)
6 documents required · 6 mandatory
₹500
GE (A) Central Jodhpur
₹98,000
1 Feb 2022
9 Nov 2021
16 Dec 2021
9 Nov 2021
14 Dec 2021
24 Nov 2021
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed .
Excavation in trenches not exceeding 1.5m wide and depth exceeding 1.5m but not exceeding 3.00 m for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed .
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soil, complete all as specified and as directed.
Removing of excavated material to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in subbase and mass conc. complete all as specified and as directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150 mm bore set in cement mortar including PCC in bed and haunching against side complete all as specified and as directed. Note :- Excavation and earth work shall be measured and paid separately.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 200 mm bore set in cement mortar including PCC in bed and haunching against side complete all as specified and as directed. Note :- Excavation and earth work shall be measured and paid separately.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 300 mm bore set in cement mortar including PCC in bed and haunching against side complete all as specified and as directed. Note :- Excavation and earth work shall be measured and paid separately.
S & F 150 mm bore Reinforced cement concrete pipes, alingning & jointing with CM 1:1, one end socketed, socket & spigot end, class NP-2, laid in trenches and jointed complete all as specified and as directed.
S & F 200 mm bore Reinforced cement concrete pipes, alingning & jointing with CM 1:1, one end socketed, socket & spigot end, class NP-2, laid in trenches and jointed complete all as specified and as directed.
S & F 300 mm bore Reinforced cement concrete pipes, alingning & jointing with CM 1:1, one end socketed, socket & spigot end, class NP-2, laid in trenches and jointed complete all as specified and as directed.
M&L precast cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate as in solid block masonry exceeding 10cm width and setting in cement mortar 1:6, complete all as specified and as directed .
M&L 15 mm thick rendering in cement mortar 1:4 on wall surface, of stone / block / brick masnory surfaces mixed with water proofing compound as per manufacturer instructions and finished the surfaces even and smooth with out using extra cement complete all as specified and as directed. Note :- WPC will be measured and paid seperately.
M&L PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in benching/ channels of manholes etc including necessary form work complete all as specified and as directed .
M&L of Precast cement concrete (1:2:4) type B-1 using 20 mm agg as in manhole cover including chamfers weathering set in cement motar 1:4 and joints to match with CM 1:3 and all complete all as specified and as directed.
M&L TMT steel bars of 6 to 8 mm dia and over, as in reinforcement, spacers, stirupps binder & cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M&L rolled mild steel sections like angle, channel, flat, square etc as in framed to manhole covers of angle or other section including hold fast and similar work confirming to Fe-290Gde E-165, complete all as specified and as directed.
Supply only water proofing compound (ISI Marked)
Dismantling of old abondonded existing manholes any depth with debris and making good earth, complete all as specified and as directed.
Dismantling of cast iron / PVC pipes of 100 mm internal dia including fittings, jointed in cement mortar complete all as specified and as directed.
Dismantling of cast iron / PVC pipes of 75 mm internal dia including fittings, jointed in cement mortar complete all as specified and as directed.
S & F sand cast, cast iron, soil / waste / vent pipes, 75mm bore, in any length with or without ears, jointed with cement sand mortar, laid in trench or floor, with and including MS clamps complete all as specified and as directed.
S & F sand cast, cast iron, soil / waste / vent pipes, 75mm bore, in any length with or without ears, jointed with cement sand mortar, fixed to walls with and including MS clamps complete all as specified and as directed.
S & F sand cast, cast iron, soil / waste / vent pipes, 100mm bore, in any length with or without ears, jointed with cement sand mortar, laid in trench or floor, with and including MS clamps complete all as specified and as directed.
S & F sand cast, cast iron, soil / waste / vent pipes, 100mm bore, in any length with or without ears, jointed with cement sand mortar, fixed to walls with and including MS clamps complete all as specified and as directed.
Demolition of brick / block or stone / boulder masonry walling built in cement mortar including all quoins arches pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and as directed.
M&L walling of random rubble, un-coursed ,well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to square rubble walling un-coursed or brought up to courses complete all as specified & directed by Engineer-in-charge.
M&L precast cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in bond stone and setting in cement mortar 1:6, complete all as specified and as directed .
PCC 1:3:6, type C-1 [using 20 mm graded granite stone aggregate] in surface channels and drains including forming fair finished drain or channel using extra cement including forms, moulds, mitred / stooped ends complete all as specified and as directed.
Flush pointing in cement mortar (1:4) to random rubble masonry , un coursed complete all as specified and directed .
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel [½ round or ¾ section] in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 100 mm dia of pipe complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc. 150 mm thick and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed.
75mm thick (average) PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate), as in sub base, the surface of concrete is to be finished even & rough to receive tile flooring surface, with out using extra cement complete all as specified and as directed.
M&L for chequered cement concrete tiles (rubberised finish) 30cm X 30cm X 20 to25mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry as in floors/ path etc over and including 15mm thick screed bed in CM 1:4 including dismantling old unserviceable tiles complete all as specified and as directed.
M&L sand filling under floor or in foundations including watering and consolidation complete all as specified and as directed.
M&L machine pressed precast conctete interlocking paver block, rubberised finish coloured of 60 mm thick of any shape and size confirming to IS 15658-2006, M-35 Grade, with grey cement and pigments (approved sample kept in GE office), complete all as specified and as directed.
M&L precast cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in kerb stone blocks of approved size and setting in cement mortar 1:4, complete all as specified and as directed .
PVC (SWR) 125mm /110mm dia gully trap, setting and jointing with solvent cement complete all as specified and as directed.
Cleaning / taking out sludge/mud/silt from manhole of following size's and capacity mechanically including dewatering septic tank and manholes when ever required including removing of sludge/muds/silt in a closed container vehicle to a distance outside MD land and buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified and as directed. (a)- Depth of manhole not exc. 1.00 m.
(b)- Depth of manhole exc. 1.00 m & not exc. 2.00 m
(c)- Depth of manhole exc. 2.00 m & above.
Cleaning of sewage pipe line 150mm bore by roding from manhole to manhole and flushing with water, after cleaning and refixing the man hole cover complete all as specified and as directed.
Cleaning of sewage pipe line 200mm bore by roding from manhole to manhole and flushing with water, after cleaning and refixing the man hole cover complete all as specified and as directed.
Cleaning of sewage pipe line 250mm bore by roding from manhole to manhole and flushing with water, after cleaning and refixing the man hole cover complete all as specified and as directed.
Removing the blockage from inlet of septic tank, with suitable wooden pugs / gunny bags and pumping out / baiing out effulent (liquid / semi liquid) from the septic tanks with diesel engine driven gen sets into closed containers or through PVC hose pipes & complete the taking out blocking arrangement and removing all the materials obtained from the traps out side MD land and cleaning the complete area including making good any damages to the traps complete all as required and as directed.
Cleaning/taking out sludge/mud/silt from manhole and septic tanks (work in foul condition) of any size and capacity mechanically including dewatering septic tank and manholes when ever required including removing of sludge/muds/silt in a closed container vehicle to a distance outside MD land and buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified and as directed. Note :-Sludge/mud/silt shall be measured before taking out from manholes/septic tank.
Cutting shurbs, vegetation, grass , bush, weed, trees and saplings not exceeding 30cm in girth, measured at a height of one metre above ground level in around the sewage system, pump house, OHT's etc., including removal of rubbish to out side MD land complete all as specified and directed .
S&F Jodhpur stone roof slabs, self faced 5cm to 7.50cm thick, 25 to 35cm wide, hoisted and set, jointed and grouted in cement mortar 1:3 including dismantling of stone slabs of any description and in any position, complete all as specified and as directed.
M&L 10 mm thick rendering in cement mortar 1:4 on wall finish of stone masnory surfaces and finished the surfaces even and smooth with out using extra cement complete all as specified and as directed.
S& F 110 mm bore cast iron Junction single [single "T"] equal or unequal with access door complete all as specified and as directed.
S& F 75 mm bore cast iron Junction single [single "T"] equal or unequal with access door complete all as specified and as directed.
S & F cast iron bends with ovall access door [any radius], diminishing pieces or tapers [larger bore measured] of 100mm bore, for cast Iron soil / waste / vent pipes complete all as specified and as directed.
S & F cast iron bends with ovall access door [any radius], diminishing pieces or tapers [larger bore measured] of 75mm bore, for cast Iron soil / waste / vent pipes complete all as specified and as directed.
S & F cast iron vent cowl of 100mm bore, for cast Iron soil / waste / vent pipes complete all as specified and as directed.
Demolition of reinforced cement concrete such as roof, floor slab, beams, stair case, landing, chajjas and similar suspended work and removing rubbish to out side MD land complete all as specified and as directed.
RCC 1:1½:3 type A1 by using 20mm graded stone aggregate as in slabs supported on walls, beams and colunms in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
TMT steel bars of 8 mm to 10mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including rough finished surfaces complete all as specified and directed.
Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide includingrough finished surfaces complete all as specified and directed.
S&F 5 cm thick sand stone slabs Jodhpur pattern/colour in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc not exceeding 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar (1:4) complete all as specified & directed by Engineer-in-charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
M&L 25mm thick (average) PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base , the surface of concrete is to be finished even & rough to receive tile flooring surface, with out using extra cement complete all as specified and as directed.
M&L for joint free coloured glazed ceramic tiles (premium quaity) of size 450mmx350mmx7mm / 450mm x 300mm x 7mm thick on vertical surface of wall over and including 10mm thick backing coat in CM 1:4 set and jointed in neat cement slurry and pointed in white cement / coloured cement to match the tiles complete all as specified and as directed.
M&L for joint free non skid ceramic tiles (premium quaity), coloured, of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 complete all as specified and as directed.
M&L for 75mm thick Plain cement concrete 1:3:6 type C1 (using 20mm graded crushed stone aggregate), as in plinth protection including necessary form work laid in alternate bays and filling the joints with bitumen mastic filler, complete all as specified and directed.
Complete removal of folliage / vegitation growth on building and in over accessible & non accessible roof, chajja / wall / parapet wall / window and similar surface etc. and cutting shurbs, vegetation, grass , bush, weed, trees and saplings not exceeding 30cm in girth, measured at a height of one metre above ground level in around the sewage system, pump house, OHT's etc., including removal of rubbish to out side MD land, complete all as specified and directed . Note :- Building height is appx 7.50 m.
Repair to steel window including taking down, replacement of unserviceble hinging device box type, handles making them in serviceable condition and refixing in same opening including making soffits and jambs in CM 1:4, complete all as specified and directed .
Taking down carefully cement conc / spalled out concrete from rcc roof projections slab, ceilings. beams, stair case, landing, chajjas and similar suspended work, upto cover depth chipping out lightly, incld necessary scaffolding work and removing rubbish to out side MD land, complete all as specified and as directed.
M&L 10 mm thick rendering in cement mortar 1:3 on wall finish of stone masnory surfaces and finished the surfaces even and smooth with out using extra cement complete all as specified and as directed.
GI chicken wire mesh of 0.71 mm dia wire & 12 mm mesh size fixed with nails & screws around RCC chajjas/facias etc, complete all as specified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removing rubbish to out side MD land complete all as specified and as directed.
M&L 15 mm thick rendering in cement mortar 1:6 on fair faces of PCC block / brick /stone masnory surfaces mixed with water proofing compound as per manufacturer instructions and finished the surfaces fair and even with out using extra cement complete all as specified and as directed. Note :- WPC will be measured and paid seperately.
M&L for rendering 10mm thick in cement mortar 1:4 on ceiling / facia / RCC chajja surfaces of concrete or stone slabs, finished even and smooth without using extra cement complete all as specified and as directed.
Preparation of new plastered or unplastered surfaces and applying three coats of white wash on wall surfaces, complete all as specified and as directed.
Preparation of new plastered or unplastered surfaces and applying three coats of white wash on ceiling surfaces, complete all as specified and as directed.
Preparation of new plastered or unplastered surfaces and applying two coats of color wash over and single coat of white wash on wall surfaces, complete all as specified and as directed.
Surface excavation not exceeding 30cm and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and as directed.
M&L precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in solid block masonry exceeding 10cm width and setting in cement mortar 1:6, complete all as specified and as directed .
S&F Jodhpur stone roof slabs, self faced 7.50cm to 10cm thick, 25 to 35cm wide, hoisted and set, jointed and grouted in cement mortar 1:3 and in any position, complete all as specified and as directed.
Taking up or down 15mm bore steel water tubing and connections including cleaning for refixing or credited to contractor, complete all as specified and as directed.
Taking up or down 20mm bore steel water tubing and connections including cleaning for refixing or credited to contractor, complete all as specified and as directed.
Taking up or down 25mm bore steel water tubing and connections including cleaning for refixing or credited to contractor, complete all as specified and as directed.
S&F GI tubing (ISI marked) 15mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors / trenches, complete all as specified and as directed.
S&F GI tubing (ISI marked) 20mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors / trenches, complete all as specified and as directed.
S&F GI tubing (ISI marked) 25mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors / trenches, complete all as specified and as directed.
Refixing of old GI tubing (ISI marked) 15mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors / trenches, complete all as specified and as directed.
Refixing of old GI tubing (ISI marked) 20mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors / trenches, complete all as specified and as directed.
Refixing of old GI tubing (ISI marked) 25mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors / trenches, complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with MS clamps of suitable size complete all as specified and as directed .
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with MS clamps of suitable size complete all as specified and as directed .
S& F 110 mm bore PVC [SWR] Junction single [single "T"] equal or unequal with access door complete all as specified and as directed.
S& F 75 mm bore PVC [SWR] Junction single [single "T"] equal or unequal with access door complete all as specified and as directed.
S& F 110 mm bore PVC [SWR], branch pieces, [single "Y"] equal or unequal with access door complete all as specified and as directed.
S& F 75 mm bore PVC [SWR], branch pieces, [single "Y"] equal or unequal with access door complete all as specified and as directed.
S& F 110 mm bore (SWR) PVC bends any radius with oval access door complete all as specified and as directed.
S& F 75 mm bore (SWR) PVC bends any radius with oval access door complete all as specified and as directed.
S& F 75 mm bore (SWR) PVC cowl complete all as specified and as directed.
S& F 110 mm bore (SWR) PVC cowl complete all as specified and as directed.
S & F 63/75 mm bore PVC [SWR] multi floor Trap with grating including jointing with solvent cement, complete all as specified and as directed.
PVC gully trap, plain square or rounded for 125x 110 mm size, jointing with solvent cement, complete all as specified and as directed.
1000 ltrs capacity rotational moulded polythene water storage tanks (white) three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I including PTMT ball valve high pressure with epoxy coated aluminium rod and high density plastic ball suitable for 25mm bore pipe weight not less than 455gms, including disconnection of old u/s existing water tank and remove to store or sch of credit, complete all as specified and as directed.. Make:- Sintex (Pure) / Rotex / Polytuf
S&F of Gun-metal globe or gate valve, with iron wheel head screwed boh ends for iron pipe, 20 mm dia and fixed, incld. taking down old existing, complete all as specified and as directed.
S&F of Gun-metal globe or gate valve, with iron wheel head screwed boh ends for iron pipe, 25 mm dia and fixed, incld. taking down old existing, complete all as specified and as directed.
Bib tap, cast copper alloy with crutch or butter fly handle, CP fancy type screwed down, screwed for 15mm bore iron pipe or for brass ferrule, complete all as specified and as directed. Make:- Jaquar / Cera / Jhonson
S & F in repair CP central hole basin mixer with regular spout with out popup waste system with 450mm long braided hose with connecting legs and wall flanges complete all as specified and as directed. Make : Model No.QQT- 7167B of JAQUAR make or equivalent model in Cera / Hindware / Johnson
Vitreous china ware wash hand basin, (Ivory color) flat back of size 550 mm X 450 mm including 32 mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible waste pipe,PVC connection15mm size with PTMT nuts of length 450mm long, complete all as specified and as directed. Make: Cera / Hindware / Johnson
Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' & 'Cold' with long screwed shanks and fly nuts, screwed for 15 mm bore iron pipe, complete all as specified and as directed . Make: Jaquar / Cera / Marc
10 ltrs capacity PVC valve less, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, flush pipe of 32 mm dia and PVC connection 15mm size, 600 mm long with PTMT nuts, color of cistern properly match with WC color, complete all as specified and as directed. Make: Cera / Hindware / Parryware
S&F in repairs, vitreous china wash down water closet pan (pedestal pattern), white including connecting to trap and to flushing pipe, anti syphonage pipe etc., complete including fixing to floor and making good of floor, including provision of plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and making good, complete all as specified and as directed. Make: Cera / Hindware / Parryware
S & F in repairs white vitreous china squatting pan "Orissa pattern" of size 580 mm X 440 mm with integral foot rests andPVC 'P' or 'S' trap including provision of cement concrete bedding 1:5:10 type E2, complete all as specified and as directed. Make: Cera / Hindware / Parryware
PVC connection of 15mm bore and 450mm long with PTMT nuts, complete all as specified and as directed.
PVC connection of 15mm bore and 600mm long with PTMT nuts, complete all as specified and as directed.
S & F in repair stainless steel tubular towel rail 600mm long fixed with CP brass screws, complete all as specified and as directed. Make: Jaquar / Cera / Marc
S & F in repair stainless steel health faucet with nozzle 30" long SS coneection pipe and CP brass spary handle fixed with CP brass screws, complete all as specified and as directed. Make: Jaquar / Cera / Marc
S & F in repair CP soap dish, complete all as specified and as directed. Make: Jaquar / Cera / Marc
S & F in repair stainless steel tubular towel ring fixed with CP brass screws, complete all as specified and as directed. Make: Jaquar / Cera / Marc
Taking down steel windows and ventilators ( glazed / fly proof) of any description complete all as specified and as directed.
S&F Factory made steel windows / ventilators ( glazed) with side hung shutters including box type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded all as specified and as directed.
S&F Factory made steel windows / ventilators ( gauged) with side hung shutters including box type hinges with steel handle and steel peg stay complete without glazing bars, dovetailed or welded all as specified and as directed.
GI wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.00mm and fixed to Al door/window, complete all as specified and as directed.
S&F 3.00 mm thick figured glass,pin head type and glazing with putty in square not exceeding 0.50 Sqm in each pane, complete all as specified and as directed.
M&L rolled mild steel sections like angle, channel, flat, square etc as in framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars ,barred iron doors; door chowkhat, ladders ;framed balusters walk ways railings, cooler stand, framed work of water tanks and similar work confirming to Fe-290Gde E-165, complete all as specified and as directed.
Taking down chowkats or frames (without taking of shutters from the frames) area not exceeding 1.5 Sqm each, complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, complete all as specified and as directed.
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, complete all as specified and as directed.
100 mm size aluminium alloy butt hinges, anodised, with mild steel hinge pin anodised type, complete all as specified and directed.
200mm size aluminium anodised barrel tower bolts of extruded section, complete all as specified and as directed.
150 mm size extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed.
M&L squared rubble walling, Jodhpur type, regular coursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to square rubble walling un-coursed or brought up to courses complete all as specified & directed by Engineer-in-charge.
Racking out joints/ pointing to squared rubble or polygonal rubble un-coursed or brought up to courses masonry built in cement mortar or cement lime mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering, complete all as specified and as directed by Engineer-in-charge.
Keyed pointing in CM 1:3 to square rubble stone masonry jodhpur type wall surfaces, uncoursed or brought up to courses , complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel [½ round or ¾ section] in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 150 mm dia of pipe complete all as specified and as directed.
M&L PCC 1:4:8 type D-2 (using 40 mm graded crused stone aggregate) as in bed to 150 mm bore RCC drain pipe including forming cradles complete all as specified and as directed.
M& L for carring out of water proofing treatment in roof in the following stages : (a)- M & L 10 mm thick sceeding in cement mortar 1:3 on brick work or concrete surfaces on roof surfaces mixed with WPC, surface finished even and smooth without using extra. (b)- Apply first coat of bitumen primer confirming to IS 3384-1986 @ 0.40Kg/Sqm. (c)- Second coat of bonding material using hot blown type bitumen confirming to IS- 702-1988 grade 85/25 @1.20 Kg/ Sqm (d) Third layer of 3 mm thick APP modified polymeric membrane with non-woven polyester reinforcement shall be laid by torch application method. The side overlaps of minimum 75 mm and the end laps of minimum 100 mm. All overlaps & joints shall be sealed as per manufacturer's instructions. (e) Fourth coat of bonding material using hot blown type bitumen confirming to IS 702-1998 of grade 85/25 @ 1.20 Kg/Sqm (f) Fifth and top most layer of surface finish 25mm thick PCC 1:2:4 type B-1 using 12.5mm graded crushed stone aggregate in roof padding over APP membrane, the surface of concrete is to be finished even and smooth with using extra cement and proved V shaped groove 6mm wide & 10mm depth filled with mastic bitumen of (1:1) complete all as specified and directed by Engr-in-charge. (e) After drying putty wash the slab and sides of sunken portion with make it clear and clean.
Supply only water proofing compound (ISI Marked)
Cutting existing cracks in V section 6 mm & 10 mm gap in existing roof / terrace, cleaning and filling solidly with a hot mixture of bitumen and clean dry sand in ratio by weight (1:1), complete all as specified and as directed .
Supply only water proofing compound
Treatment of the sunken floor slab comprises of the following specification complete all as specified and as directed by Engineer-in-charge. Make:- Dr. Fixit / M/s Sika India Pvt Ltd / M/s Fosroc chemicals / STP (a) Demolition of cement concrete filling of any description in sunken portion in toilet & bathroom , removing debris outside MD land. (b) Cleaning the sunken portion of RCC slab surfaces (incld. Verticle total depth plus skirting height) of floors by wire brush, chisel cut any motar sticking to the surface and brooming completely. Accordingly laying 40 mm avg thick PCC 1:2:4 type B-0 using 12.5 mm graded stone agg, mixed with integral water proofing compound, as in padding concrete to achieve proper slope incld. cutting holes in bricks or RCC wall for spout. (WPC shall be measured and paid separately) © Rendering of uneven surfaces with 10 mm thik CM 1:4 Mixed with integral water proofing compound @ 3% by weight cement consumed fill with water and check dampness and seepage, where dampness / seepage is noticed, nozzels shall be fixed and grouting carried out. WPC shall be measured and paid separately. (d) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty. (f) Applying item no. 142. This item shall be measured and paid separatly. (g) Rendering of bottom and sides with 15 mm thick CM 1:4 Mixed with integral water proofing compound @ 3% by weight cement consumed fill with water as per manufracturer specification, including rounding of corners and junction sloping towards spout WPC shall be measured and paid separately. (h) M&L PCC 1:5:10 type C2, 75 mm thick complete all as specified (i) M&L PCC 1:2:4 type C2, 25 mm thick complete all as specified Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage, seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of Engineer-in-Charge and record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing is included in the rates quoted above.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc . removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed.
Point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including heavy duty drawn through and including in 20mm dia PVC concealed conduit with all accessories complete concealed in wall/roof/floor etc, ISI marked with modular metal flush box of suitable size for mounting of modular switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for,one way switch One light / fan / bell point controlled by one, one way switch, complete all as specified and directed .
All as per Serial Item No. 144 above but one 3/5 pin socket outlet 5/6 Amps on independent board, complete all as specified and as directed.
All as per serial Item No.144 above but for 15 Amps 5/6 pin socket point on independent board with 2.50 Sqmm PVC insulated FRLS multi-stranded copper conductor with 2.50 Sqmm PVC insulated FRLS multi-stranded copper conductor as earth wire, complete all as specified and directed .
M&L switch piano, flush type, single pole, one way, 5/6 Amps, 230 Volts, complete all as specified and as directed. Make: Legrand / L&T / Schneider
M&L switch piano, flush type, single pole, one way, 16 Amps, 230 Volts, complete all as specified and as directed. Make: Legrand / L&T / Schneider
M&L socket outlet 5 Amps 2-in-1, 3/5 pin 230V AC flush type, complete all as specified and directed. Make: Legrand / L&T / Schneider
M&L socket outlet 6/16 Amps 2-in-1, 3/5 pin 230V AC flush type, complete all as specified and directed. Make: Legrand / L&T / Schneider
S& F integrated LED channel tube light fitting, 1X20W, 230V, energy efficient box type, integral, sleek polycarbonate with white acrylic cover epoxy powder coated with fluorscent tube light 1X20W complete with all accesories internally pre wired and connectiong up with twin core twisted flexible copper conductor of suitable size, complete all as specified and as directed. Make:- Havells HEXBTP7IN1S022 or its equivalent in CG / Philips
S&F batten lamp holder,metal case body of brass, suitable for LED batten fitting 9W 230 volts, complete all as specified and as directed .
Supply, Fix, connecting and testing of energy efficient, pressure die cast aluminium housing with heat resistant toughened glass with frame & IP-66 protection and impact resistance IK 07, LED street light luminaries 45 watt 5700K, fixed on pole incld. 1.60 mtr long 40 mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of F1 40 mm x 6 mm with nuts, bolts & washers and conductor to fitting with 3 core 1.50 sqmm pvc insulated cable Make : Havells Cat Part No LHETAXU7PN6J045 or techno commercially equivalent model of make Bajaj/Philips/CG
S&F factory made prewired distribution board in sheet metal enclosure in double door with 200A rated bus bar,SPN 8 way, 240V for fixing MCB's, including concealed in wall , complete all as specified and as directed. Make:- Legrand / Havells / L&T / ABB
S&F MCB SP ‘B’ Curve 10KA, 6 to 32 amps, complete all as specified and directed . Make:- Legrand / Havells / L&T
S&F MCB SPN ‘C’ Curve 10KA, 40 amps, complete all as specified and directed . Make:- Legrand / Havells / L&T
M&L in repairs submain wiring with two runs of 4 sqmm with one run of 2.50 Sqmm earth wire of 1100V grade FRLS PVC insulated multi-stranded copper conductor, single core cable conforming to IS 694 drawn through in PVC concealed conduit with accessories fixed on wall / ceiling and connected to common earth dolly , complete all as specified and directed. Note :- Two runs of 4 sqmm and one run of 2.50 sqmm shall be measured as one length for the purpose of measurement.
Supply, laying, jointing, testing and commissioning 1100 volt grade heavy duty XLPE insulated LT under ground cable, sheathed, as per IS- 7098 (Part I) 1988, galvanized steel strip armoured heavy duty solid aluminum conductor laid in trenches / passed through pipe/duct road crossing, fixed on poles/ wall with clamps made out of mild steel flat iron including fixing accessories like brass cable glands double compression type, lugs, nuts, bolts, washers etc of size 2 core 10 sqmm , complete all as specified and directed
Note:- 1. All items in BOQ are for"Materials and labour (M&L) /Supply and fix (S&F)" and to be executed in "Repairs " unless otherwise specifically mentioned as "Supply only" or "fixing only" or "Supply and Laying only" in BOQ. Bidders are requested to quote their rates accordingly. 2. The contract amount shall be arrived at after duducting amount of Schedule of Credit from the Total quoted amount.
mahalaxmi enterprises
M/S SUMAN ENTERPRISES
M/S KAUTILYA GARG
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .