Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC SCO 26 SEC 30 KURUKSHETRA 136118 | KURUKSHETRA | HARYANA | 136118 | L1 | Accepted-AOC LOA | |
| 2 | L2₹13.4 L+₹94,417 (7.55%)Rejected-Finance PLOT NO F28 COMPLETE COOLING SOLUTIONS LLP PHASE 8 INDUSTRIAL AREA SAS NAGAR MOHALI PUNJAB 160055 | S A S NAGAR | PUNJAB | 160055 | L2 | Rejected-Finance Highest | |
| 3 | Rejected-Technical | - | Rejected-Technical Non Responsive |
| Sl No | Description | Qty | Unit | Pacific Engineers L1 | Complete Cooling Solutions LLP L2 |
|---|---|---|---|---|---|
| 1.00 | SITC of Interconnecting refrigerant pipe work with 28.58 mm OD (19mm insulation) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. | 28 | Metre | 1,560 ₹43,680 Lowest | 1,734 ₹48,552 |
| 2.00 | SITC of Interconnecting refrigerant pipe work with 22.2mm OD (19mm insulation) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. | 12 | Metre | 1,480 ₹17,760 | 1,127 ₹13,524 Lowest |
| 3.00 | SITC of Interconnecting refrigerant pipe work with 19.05 mm OD (19mm insulation) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. | 12 | Metre | 1,240 ₹14,880 | 1,183 ₹14,196 Lowest |
| 4.00 | SITC of Interconnecting refrigerant pipe work with 15.88 mm OD (19mm insulation) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. | 75 | Metre | 1,180 ₹88,500 | 976 ₹73,200 Lowest |
| 5.00 | SITC of Interconnecting refrigerant pipe work with 12.7 mm OD (13mm insulation) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. | 23 | Metre | 930 ₹21,390 | 668 ₹15,364 Lowest |
| 6.00 | SITC of Interconnecting refrigerant pipe work with 9.52 mm OD (13mm insulation) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. | 55 | Metre | 780 ₹42,900 | 521 ₹28,655 Lowest |
| 7.00 | SITC of Interconnecting refrigerant pipe work with 6.35 mm OD (13mm insulation) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline. | 8 | Metre | 670 ₹5,360 | 377 ₹3,016 Lowest |
| 8.00 | Supply, installation testing and commissioning of 32 mm dia Rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation complete in all respect upto entire satisfaction Engineer in charge of work. Make: Supreme / Prince / Kissan. | 80 | Metre | 165 ₹13,200 Lowest | 191 ₹15,280 |
| 9.00 | Inverter based VRF System
Supply, installation testing and commissioning of 20 HP (Outdoor Unit) Air Cooled VRV/VRF unit with Rotary
/scroll Compressor capable of modulating capacity, i.e it should be able to vary speed of the compressor as per the varying load conditions and works on R410A with heating and cooling both.The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed form rust-proofed mild steel panels coated with powder coated finish.ODU Machine should have Top discharge air type. Each ODU should have variable compressors. Each unit shall be equipped, with an oil separator to ensure stable operation with long refrigerant piping.Note:- Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP at 100% Load to be )4.0 as per ARI Conditions complete in all respect upto entire satisfaction Engineer in charge of work. The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identical of the ODU including all labour and petty material required to complete the job in all respect. Makes: Mitsubishi Electric, O-General. | 1 | Each | 5,35,000 ₹5,35,000 Lowest | 6,00,000 ₹6,00,000 |
| 10.00 | Supply, installation testing and commissioning of 4 WAY Cassette Indoor unit of capacity 1.5 Tr. with evaporator coil, fan and fan motor drain pump drain pan and Grille pannel including all labour and petty material required to complete the job in all respect. Makes: Mitsubishi Electric, O-General. | 1 | Each | 39,200 ₹39,200 Lowest | 48,600 ₹48,600 |
Tender Value
₹11.9 L
EMD Value
₹23,880
Closing Date
5 Sept 2025, 2:00 pmClosed
NAVEEN RATHEE
ED - Ambala
Special Repair of Interview and Paper Checking Room with Examination Hall in the Office building of Haryana Public Service Commission (HPSC), Sec.-4, Panchkula (Pdg. VRV / VRF System Only).
2025_HRY_468045_1
2025F84A596D 0B8E 49E2 B479 5E29C6C41280663BAR
Open Tender
Civil Works
Works
220 days
Ambala
Special Repair of Interview and Paper Checking Room with Examination Hall in the Office building of Haryana Public Service Commission (HPSC), Sec.-4, Panchkula (Pdg. VRV / VRF System Only).
2 documents required · 2 mandatory
₹1,000
₹23,880
Yes
9 Oct 2025
27 Aug 2025
5 Sept 2025
28 Aug 2025
5 Sept 2025
28 Aug 2025
Amount
SITC of Interconnecting refrigerant pipe work with 28.58 mm OD (19mm insulation) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline.
SITC of Interconnecting refrigerant pipe work with 22.2mm OD (19mm insulation) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline.
SITC of Interconnecting refrigerant pipe work with 19.05 mm OD (19mm insulation) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline.
SITC of Interconnecting refrigerant pipe work with 15.88 mm OD (19mm insulation) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline.
SITC of Interconnecting refrigerant pipe work with 12.7 mm OD (13mm insulation) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline.
SITC of Interconnecting refrigerant pipe work with 9.52 mm OD (13mm insulation) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline.
SITC of Interconnecting refrigerant pipe work with 6.35 mm OD (13mm insulation) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline.
Supply, installation testing and commissioning of 32 mm dia Rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation complete in all respect upto entire satisfaction Engineer in charge of work. Make: Supreme / Prince / Kissan.
Inverter based VRF System Supply, installation testing and commissioning of 20 HP (Outdoor Unit) Air Cooled VRV/VRF unit with Rotary /scroll Compressor capable of modulating capacity, i.e it should be able to vary speed of the compressor as per the varying load conditions and works on R410A with heating and cooling both.The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed form rust-proofed mild steel panels coated with powder coated finish.ODU Machine should have Top discharge air type. Each ODU should have variable compressors. Each unit shall be equipped, with an oil separator to ensure stable operation with long refrigerant piping.Note:- Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP at 100% Load to be )4.0 as per ARI Conditions complete in all respect upto entire satisfaction Engineer in charge of work. The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identical of the ODU including all labour and petty material required to complete the job in all respect. Makes: Mitsubishi Electric, O-General.
Supply, installation testing and commissioning of 4 WAY Cassette Indoor unit of capacity 1.5 Tr. with evaporator coil, fan and fan motor drain pump drain pan and Grille pannel including all labour and petty material required to complete the job in all respect. Makes: Mitsubishi Electric, O-General.
Supply, installation testing and commissioning of 4 WAY Cassette Indoor unit of capacity 2.6 Tr. with evaporator coil, fan and fan motor drain pump drain pan and Grille pannel including all labour and petty material required to complete the job in all respect. Makes: Mitsubishi Electric, O-General.
Supply, installation testing and commissioning of 4 WAY Cassette Indoor unit of capacity 3.0 Tr. with evaporator coil, fan and fan motor drain pump drain pan and Grille pannel including all labour and petty material required to complete the job in all respect. Makes: Mitsubishi Electric, O-General.
SITC of Remotes (Cordless) including all labour and petty material required to complete the job in all respect. Makes: Mitsubishi Electric, O-General.
SITC of REFNETS including all labour and petty material required to complete the job in all respect. Makes: Mitsubishi Electric, O-General.
SITC of 2 Core 1.0 Sqmm Sheathed Control cabling Make: Polycab, Havells / Finolex
S/E/T/C of 100-150Amp. 2-way G frame Distribution Panel with 40 Amp 2Nos MCCB to complete the job in all respect upto the entire satisfaction of Engineer in charge of work. Make Havells, LandT, Siemens
SITC of 16 Sqmm 4 core Copper Armd. Power Cable, loose/ in existing pipe complete in all respect with petty material and necessary connections upto the entire satisfaction of engineer in charge of work. Make Finolex, Polycab, Havells.
Complete Cooling Solutions LLP (BID ID -1330217)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .