Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1 Cr
EMD Value
₹80,000
Closing Date
28 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, RANDER DIVISION
Work of ARC for Erection & Maintenance of HT/LT Line and TC work and other maintenance work O/H & UG XLPE Cable & Laying of underground cable network with terminations in the area of DGVCL under All scheme for All Sub division under Rander Division.
266766
DGVCLSDPLN/0059/01/2026 Approved Date: 19-01-2026
Open
Electrical - All
Works
Surat
3 documents required · 3 mandatory
₹5,900
Yes
SURAT
₹80,000
Yes
19 Jan 2026
19 Jan 2026
19 Jan 2026
28 Jan 2026
19 Jan 2026
Schedule-B for Work of ARC for Erection & Maintenance of HT/LT Line and TC work and other
maintenance work O/H & UG XLPE Cable & Laying of underground cable network with terminations in
the area of DGVCL under All scheme for All Sub division under Rander Division.
Part- A- HT,LT& TC WORK & O/H UG XLPE Cable
CAPITAL WORK LABOUR RATES FOR FY 2024-25 (WITHOUT GST)
Item Code Item Unit FY 2024-25
HT TAPPING FROM THE EXISTING POLE
INCLUDING FIXING OF CROSS ARMS,
CLAMPS ANTI-CLIMBING DEVICES, DANGER
BOARD, INSULATORS ETC. COMPLETE AND
1 9926000001 PAINTING OF FABRICATED MATERIALS AND No.
NUMBERING COMPLETE WITH COST OF
PAINTS AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SET
ERECTION OF PSC POLES OF 8 *200 KG
INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OFCROSS
ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC.
2 9926000002 COMPLETE AND PAINTING OF FABRICATED No.
MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND
ERECTION OF STEEL POLES OF 9 TO
METERS INCLUDING EXCAVATION OF PIT
AND REFILLING OF EARTH, FIXING
OFCROSS ARMS, TOP FITTING CLAMPS
ANTI-CLIMBING DEVICES, DANGER BOARD,
INSULATORS ETC. COMPLETE AND
PAINTING OF STEEL POLE, FABRICATED
MATERIALS USED ON THE POLEAND
NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND
ERECTION OF STEEL POLE OF 13 METERS
FOR RAILWAY CROSSING ON BG/MG/NG
LINE FOR 0.400/11/22KV OVERHEAD LINES
I.E INCLUDING EXCAVATION OF PIT &
REFILLING OF EARTH, FIXING CROSS ARMS,
TOP FITTING CLAMPS,ANTI-CLIMBING
4 9926000004 DEVICES DANGER BOARD, INSULATORS No.
ETC. COMPLETE AND PAINTING OF STEEL
POLES, FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COSTOF
PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SETS
ERECTION OF DOUBLE POLE STRUCTURE
OF 8 METERS 200 KG PSC POLES
INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTHING, FIXING OF
CHANNELS, SUPPORTING ANGLES,CLAMPS,
ANTI-CLIMBING DEVICES DANGER
5 9926000005 BOARDS,INSULATORS ETC.COMPLETE AND No.
PAINTING OF FABRICATED MATERIALS
USED ON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION
OF GUY SETS AND EARTHING.(WITHOUT AB
ERECTION OF DOUBLE POLE STRUCTURE
OF 9 TO 11 METERS.STEEL POLE
INCLUDING EXCAVATION OF PITS &
REFILLING OFEARTH, FIXING OF
CHANNELS, SUPPORTING ANGLES,
CLAMPS,ANTI-CLIMBING DEVICES DANGER
6 9926000006 BOARDS, INSULATORS ETC.COMPLETE & No.
PAINTING OF POLES,FABRICATED
MATERIALSUSED ON THE POLES AND
NUMBERING WITH COST OF PAINTSAS PER
STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND
EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE
WITH MOUNTING OF AB SWITCH, HG FUSES
OF 8 MTRS 200 KG PSC POLES INCLUDING
EXCAVATION OF PITS AND REFILLING OF
EARTH,FIXING OF CHANNELS SUPPORTING
ANGLES, CLAMPS, ANTI-CLIMBING DEVICES,
7 9926000007 DANGER BOARDS, INSULATORS,DOFUSES No.
ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COSTOF
PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDINGOF ERECTION OF GUY SET
AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE
WITH MOUNTING OF AB SWITCH,HG FUSES,
9 TO 11 METERS STEEL POLES INCLUDING
EXCAVATION OF PITS AND REFILLING OF
EARTH, FIXING OFCHANNEL, SUPPORTING
ANGLES, CLAMPS, ANTI-CLIMBING DEVICES
8 9926000008 , DANGER BOARDS, INSULATORS, ETC. No.
COMPLETE AND PAINTING OF POLES
FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SET
AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURES
WITH MOUNTING OFAB SWITCH, HG
FUSES, TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX. OF
METER,200KG PSC POLE METERS POLES
INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROMSTORES TO SITE,
FIXING OF CHANNELS, SUPPORTING
ANGLES,BRACINGS CROSS ARMS CLAMPS,
ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USEDON THE
POLES AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SETS
ERECTION OF DOUBLE POLE STRUCTURE
WITH MOUNTING OF AB SWITCH,HG FUSES
TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX 9 TO
METERS STEEL POLES INCLUDING
EXCAVATION OF PITS & REFILLING OF
EARTH CARTING OF TRANSFORMERS FROM
STORE TO SITE, FIXINGOF CHANNELS
10 9926000010 SUPPORTING ANGLES, BRACING, CROSS No.
ARMS,CLAMPS, ANTICLIMBING DEVICES,
DANGER BOARDS,CONDUCTOR AND CABLE
WIRING ETC. COMPLETE AND PAINTING OF
POLES FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING AS PER
STANDARD SPECIFICATION BUT
EXCLUDING ERECTIONS OF GUY SETS AND
ERECTION OF GUY SET INCLUDING
EXCAVATION OF PITS & REFILLING OF
EARTH AS PER STANDARD SPECIFICATION
11 9926000011 WITH STAY CLAMPS, STAY WIRE, ANCHOR No.
ROD, TURN BUCKLE, EYEBOLT, GUY
INSULATOR, CEMENT CONCRETE BLOCK
ETC. BUT EXCLUDING CONCRETING.
CONCRETING OF POLES, GUYS, ETC.
INCLUDING COST OF CEMENT SAND METAL
12 9926000012 (1:2:4) AND WATER ETC. AS PER STANDARD CMT
SPECIFICATION.(cement Should be 53 grade)
used for Concreting.
ERECTION OF COIL TYPE EARTHING
INCLUDING COST OF COAL,SALT ETC. BUT
13 9926000013 WITHOUT COST OF GI WIRE AS PER No.
STANDARD SPECIFICATION(20kg solt+20kg
ERECTION OF GI PIPE/CI PLATE TYPE
EARTHING INCLUDINGCOST OF COAL SALT
14 9926000014 ETC. BUT WITHOUT COST OF PIPE/GIPLATE No.
GI WIRE AS PER STANDARD
SPECIFICATION.(20kg solt+20kg coal)
ERECTION OF STREET LIGHT FIXTURE
COMPLETE WITH CLAMPS, BRASS NIPPLE,
BRASS HOLDER TECK WOOD
BUSH,REFLECTORS FUSE, WIRING ETC. AS
PER STANDARD SPECIFICATION BUT
EXCLUDING COST OF MATERIALS.
STRINGING OF(30mm2)ACSR/34MM@,55MM2
AAA CONDUCTOR for ALL TYPE OF
16 9926000016 CONDUCTOR (EXCEPT DOG CONDUCTOR)
FOR 11/22KV & LT LINES INCLUDING FIXING
OF INSULATORS, BINDING JUMPERING ETC.
STRINGING OF GI WIRE 8 SWG INCLUDING
BINDING JUMPERING ETC.
PROVIDING SINGLE PHASE SERVICE
CONNECTION WITH PVC 2.5/4MM2 TWIN
CORE CABLE FROM TERMINAL POLE TO
18 9926000018 METERING POINT INCLUDING FIXING OF No.
METER WITH METER EARTHING COMPLETE
WORK AS PER STANDARD SPECIFICATION
BUT EXCLUDING COST OF MATERIALS.
PROVIDING THREE PHASE 4 WIRE SERVICE
CONNECTION WITH PVC 4MM2/10MM2 FOUR
CORE CABLE FROM TERMINAL POLE TO
19 9926000019 METERING POINT INCLUDING FIXING OF No.
METER WITH METER EARTHING COMPLETE
WORK AS PER STANDARD SPECIFICATION
BUT EXCLUDING COST OF MATERIALS.
ADDITIONAL COST FOR EXCAVATION OF PIT
IN HARD ROCK AREA FOR ERECTION OF
POLE/ GUY ETC. AS PER STANDARD
SPECIFICATION OVER & ABOVE NORMAL
20 9926000020 COST COVERED AGAINST EXCAVATION OF No.
PIT UNDER NORMAL SOIL FOR ERECTION
OF POLE,GUY, DOUBLE POLE STRUCTURE
EARTHING WITH THE APPROVAL OF
SUPDT.ENGINEER.
PROVIDING GUARDING TO HT LINE ON
ROAD/ RAIL CROSSING.
PROVIDING GUARDING OF LT LINES ON
ROAD/RAIL CROSSING.
23 9926000023 LT LINE TAPPING- SINGLE PHASE No.
24 9926000024 LT LINE TAPPING- THREE PHASE No.
Stringing/LAYING OF OVER HEAD LT CABLE
FOR ROAD CROSSING,HT LINE CROSSING
AND TELEPHONE LINE CROSSING ETC.(PER
ERECTION OF SINGLE POLE STRUCTURES
WITH , HG FUSES,TRANSFORMERS,
LIGHTENING ARRESTOR, DISTRIBUTION
BOX. ON 8 METERS 200 KGAND PSC POLE
INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE,
FIXING OF CHANNELS, SUPPORTING
26 9926000026 ANGLES,BRACINGS CROSS ARMS CLAMPS, No.
ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE
POLE AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OFGUY SETS
ERECTION OF SINGLE POLE STRUCTURES
WITH MOUNTING OFAB SWITCH , HG
FUSES,TRANSFORMERS,
LIGHTENINGARRESTOR, DISTRIBUTION
BOX. ON 9 to 11 METERS RSJ POLE
INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE,
FIXING OF CHANNELS, SUPPORTING
ANGLES,BRACINGS CROSS ARMS CLAMPS,
ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE
POLE AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OFGUY SETS
ERECTION OF PSC POLES OF 10 *270 KG
INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OF CROSS
ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC.
28 9926000028 COMPLETE AND PAINTING OF FABRICATED No.
MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND
ERECTION OF DOUBLE POLE STRUCTURE
OF 10 METERS 270 KG PSC POLES
INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTHING, FIXING OF
CHANNELS, SUPPORTING ANGLES,CLAMPS,
ANTI-CLIMBING DEVICES DANGER
29 9926000029 BOARDS,INSULATORS ETC.COMPLETE AND No.
PAINTING OF FABRICATED MATERIALS
USED ON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION
OF GUY SETS AND EARTHING.(WITHOUT AB
STRINGING OF 100MM2 ACSR/100MM2 AAAC
CONDUCTOR FOR 11/22KV & LT LINES ONE COND PER
INCLUDING FIXING OFINSULATORS, KM
BINDING JUMPERING ETC.
STRINGING OF DOG CONDUCTOR FOR
31 9926000031 11/22KV & HT LINES INCLUDING FIXING OF
INSULATORS, BINDING JUMPERING ETC.
ERECTION OF DOUBLE POLE STRUCTURES
WITH MOUNTING OF AB SWITCH, HG
FUSES, TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX. OF
METERS 270 KGAND PSC POLES INCLUDING
EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS
FROMSTORES TO SITE, FIXING OF
CHANNELS, SUPPORTING
ANGLES,BRACINGS CROSS ARMS CLAMPS,
ANTI-CLIMBING DEVICES,DANGER BOARDS,
CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SETS
DISMENTALLING OF 8 MTR PSC POLE WITH
CREDITING OF FABRICATION AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE
OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF 10 MTR PSC POLE WITH
CREDITING OF FABRICATION AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE
OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER
CENTRE (8 MTR PSC POLE) (WITH
TRANSFORMER) WITH CREDITING OF
35 9926000035 FABRICATION & TRANSFORMER AT STORE No.
& STACKING OF POLE SAFELY ON ROAD
SIDE OR CREDITING TO DEPARTMENTAL
DISMENTALLING OF TRANSFORMER
CENTRE (8 MTR PSC POLE) (WITHOUT
TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE & STACKING OF
POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM +
1*25 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, LT SHACKLE INSULATOR ETC.
FOR FIXING OF MESSENGER WIRE AND TO
PROVIDE SERVICE CONNECTION ON
AERIAL BUNCH CABLE BY INSULATED
PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS
REQUIRED & DIRECTED BY ENGINEER IN
STRINGING OF LT ABC OF 3*50 SQ MM +1*25
SQ MM+1*35 SQ MM INCLUDING FITTING OF
ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF
38 9926000038 CROSS ARM, LT SHACKLE INSULATOR ETC. KM
FOR FIXING OF MESSENGER WIRE AND TO
PROVIDE SERVICE CONNECTION ON
AERIAL BUNCH CABLE BY INSULATED
PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS
REQUIRED & DIRECTED BY ENGINEER IN
STRINGING OF 11KV ABC OF 3*95 SQ MM
+80 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, BINDING TO PIN
INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ MM
+95 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, BINDING TO PIN
INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED AND
DIRECTED BY ENGINEER IN CHARGE
STRINGING OF LT ABC OF 2*50 SQ MM +1*25
SQ MM+ 35 SQ MM INCLUDING FITTING OF
ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, LT SHACKLE INSULATOR ETC.
FOR FIXING OF MESSENGER WIRE AND TO
PROVIDE SERVICE CONNECTION ON
AERIAL BUNCH CABLE BY INSULATED
PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS
REQUIRED & DIRECTED BY ENGINEER IN
DISMENTALING OF RSJ (9/11 METER) POLE
42 9926000042 AND CREDITING THE OLD MATERIAL TO No.
DISMENTALING OF TRANSFORMER
CENTER ON 10MTR,270KG PSC
POLE(WITHOUT TRANSFORMER) WITH
43 9926000043 CREDITING OF FABRICATION AT STORE No.
AND STACKING OF POLE SAFELY ON ROAD
SIDE OR CREDITING TO DEPARTMENTAL
DISMENTALING OF TRANSFORMER
CENTER ON 10MTR,270KG PSC POLE(WITH
TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE AND STACKING OF
POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95 SQ MM
+80 SQ MM AND CREDITING FITTING OF
ALL ACESSARIES AND FABRICATION TO
DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ
MM +95 SQ MM AND CREDITING FITTING
OF ALL ACESSARIES AND FABRICATION TO
DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM +
1*25 SQ MM AND CREDITING FITTING OF
ALL ACESSARIES TO DEPARTMENTAL
DISMENTALING OF LT ABC OF 3*50 SQ MM
+1*25 SQ MM+1*35 SQ MM AND CREDITING
FITTING OF ALL ACESSARIES TO
DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM
+1*25 SQ MM+ 35 SQ MM AND CREDITING
FITTING OF ALL ACESSARIES TO
DEPARTMENTAL STORE.
RESTRINGING OF ALL TYPE OF
CONDUCTOR (EXCEPT DOG CONDUCTOR) ONE COND PER
FOR 11/22KV & LT LINES INCLUDING FIXING KM
OF INSULATORS, BINDING JUMPERING ETC.
RESTRINGING OF DOG CONDUCTOR FOR
51 9926000051 11/22KV HT LINES INCLUDING , BINDING
LABOUR CHARGE FOR THE INSTALLATION
52 9926000052 OF NEW DTR METER. (METER WILL BE No.
PROVIDED BY DGVCL)
LABOUR CHARGE FOR THE REPLACEMENT
OF DTR METER AND OLD METER SHOULD
BE CREDITED TO SDN STORE. (METER WILL
BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR PROVIDING CT COIL
54 9926000054 FOR DTR METER CONNECTION. (CT COIL PER CT
WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF
CT COIL FOR DTR METER CONNECTION
55 9926000055 AND OLD CT SHOULD BE CREDITED TO SDN PER CT
STORE. (CT COIL WILL BE PROVIDED BY
LABOUR CHARGE FOR FIXING OF MMB FOR
56 9926000056 DTR METER (MMB WILL BE PROVIDED BY No.
LABOUR CHARGE FOR REPLACEMENT OF
57 9926000057 DTR METER BOX. (METER WILL BE No.
PROVIDED BY DGVCL)
PROVIDING / REPLACEMENT OF 1.5 SQ MM
58 9926000058 10 CORE COPPER CABLE 3.5 METER (CABLE No.
TO BE PROVIDED BY AGENCY)
LABOUR CHARGE FOR
PROVIDING/RECONNECTION OF TERMINAL PER
CONNECTION WITH PROPER SIZE OF LUGS. TERMINATION
(LUGS COST IS BORNE BY AGENCY)
LABOUR CHARGE FOR THE SPOT READING
OF DTR METER WITH DETAIL SURVEY OF
DEFECT IF ANY. A DULY SIGN COPY BY
SURVEYOR PERSON OF AGENCY IN PRO-
60 9926000060 FORMA REPORT SHOULD BE SUBMITTED PER DTR
TO SDN OFFICE.(* ONLY IF ALL PARAMETER
OF VOLTAGE, CURRENT & LOAD AS SHOWN
IN PER-FORMA IS FILLED) AS PER THE
INSTRUCTION OF ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING
OF DTR METER WITH DETAIL SURVEY OF
DEFECT IF ANY. A DULY SIGN COPY BY
SURVEYOR PERSON OF AGENCY IN PRO-
FORMA REPORT SHOULD BE SUBMITTED
TO SDN OFFICE. (DULY FILL PER-FORMA IN
FAULT CONDITION IN WHICH READING
PARAMETER IS NOT SHOWN IN METER)
INSTALLATION OF DTR METER INCLUDING
METER BOX, PROVIDING & FIXING OF 1.5SQ
MM SINGLE STRAND 10 CORE ARMOURED
62 9926000062 COPPER CABLE (3.5METER), TERMINATION No.
IN METER & COIL ETC.(METER, METER BOX,
C.T./P.T. COIL WILL BE PROVIDED BY
INSTALLATION OF DTR METER INCLUDING
METER BOX, TERMINATION IN METER &
63 9926000063 COIL ETC. (WITHOUT 10CORE COPPER No.
CABLE) (METER, METER BOX, C.T./P.T. COIL
WILL BE PROVIDED BY DGVCL)
Binding of messanger Conductorat with a
distance not more than 0.75 mtr with 6 turns
minimum on XLPE Cable with single strand
binding wire (including cost of binding wire)
Supply and Installation of 11/22 kV Distribution
Transformers HT Terminal protector (UV
65 9926000086 Resistance) with using 95/120/150 sq.mm long PER SET
barrel aluminum lug. (1Set = 3 Nos i.e. on R, Y,
Supply & Installation of HT EPR Tap on 11/22 kV
Distribution Transformer with replacement of
bare conductor by HT ABC conductor (DO
66 9926000087 bottom side to transformer) after removal of semi PER SET
conductor by HT ABC (6 inch both side). HT
ABC to be supplied by DGVCL. (1Set = 3 Nos
Supply, Installation, Testing and Commissioning
of Maintenance Free, Ready Capsule, Pipe-In-
Cage (Pic) Type, Earth Electrodes for HT Feeder
Pole Having 2000 mm Electrode Length as per
the Tender Specifications and Drawing. (All
Materials Will Be Supplied By Agency)
Supply, Installation, Testing and Commissioning
of Maintenance Free, Ready Capsule, Pipe-In-
Cage (Pic) Type, Earth Electrodes for HT Feeder
Pole Having 3000 mm Electrode Length as per
the Tender Specifications And Drawing. (All
Materials Will Be Supplied By Agency)
Supply and Installation of 25 X 3 mm GI Strip
having hot dip- galvanized-zinc coating of 80-100
microns without any joints or welding. Both the
end of the GI strip should be connected with GI
nut bolts and required fabrication work for giving
separate earthing connections to
69 9926000090 (1) Neutral of the transformer Meter
(2) MS structures of the transformer center
(Approximately 25 meter GI strip per transformer
- as per requirement and instruction of
Engineer in- charge) (All Materials will be
supplied by Agency)
Supply and Installation of uPVC standard make
Pipe of 1.25" diameter for covering GI strip with
UV protected Cable Ties of 550 X 7.6 mm size to
70 9926000092 bind with pole face(Approximately 25 meter Meter
uPVC pipe for GI strip covering per transformer
centre -as per requirement and instruction of
Engineer in-charge.
Supply & fixing of upto 33 kV Conducotr sleev for
Busbar to Drop out Fuse and Drop out fuse to
71 9926000093 Transformer H.T. including Busbar (12 mm Meter
sleev) as per technical specification. (All
Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conducotr sleev for
Busbar to Drop out Fuse and Drop out fuse to
72 9926000094 Transformer H.T. including Busbar(15 mm sleev) Meter
as per technical specification. (All Materials will
be supplied by Agency)
Supply & fixing of Disc type Red Color FRP(Non-
flammable) material with Weather resistant, Non-
conductive bird guard OD=300 MM, ID=33 MM,
Width =1.25 MM, one side cut from ID to OD.
(All Materials will be supplied by Agency)
Providing and fixing of LT Terminal protectors
i.e. Re-useable boot (LT Side 1.1 kV) including
74 9926000096 LT (1.1 kV) insulating taps. All live part at LT No
side shall be covered with fixing of LT insulating
75 Nylon Net around Transformer Center
75.1 9926000097 Nylon Net (12 * 15 ft) Per Net
75.2 9926000098 Nylon Dori Per TC
Labour charge for fitting Nylon Net (All fabricated
75.3 9926000099 material for fitting nylon net shall be provided by Per TC
LABOUR RATES FOR MAINTENANCE WORKS
Item Code Details of works Unit FY 2024-25
(A) LINE MAINTENANCE
1 9924000001 Cutting of Tree branches surounding HT/LT line Per Tree
Replacement of old jumpers & providing new
2 9924000002 double jumpers with 8" binding [D Type] & No.
capsuling with PVC pipe etc
3 9924000005 Support pole for Stay PSC/STP/RSJ No.
4 9924000006 Pin binding of conductor 11/22kv Pin insulator No.
Pin binding of conductor 11/22kv Pin insulator
per pole in costle area with cleaning .
6 9924000008 Pin binding of conductor LT shakel insulator No.
Replacement of one/both disc.insulator at strain
8 9924000010 Replacement of LT shackle insulator at cut point No.
9 9924000011 Refixing of V cross Arm No.
Replacement of V cross Arm (With
Transportation & Painting)
11 9924000013 Refixing of Top fitting in proper position No.
12 9924000014 Replacement of Top fitting No.
13 9924000015 Replacement of LT cross Arm No.
Providing DO fuse on DP with carting &
jumpuring(ONE DO FUSE)
Numburing of pole with paint by preparing back
15 9924000017 ground of one colour and have lettering(height 3" No.
* width 0.5") using stensil
16 9924000018 Fixing of MMB(1PH.) at consumer end No.
17 9924000019 Fixing of MMB(3PH.) at consumer end No.
18 9924000020 Replacement of (1ph.) meter for Urban area No.
19 9924000021 Replacement of (1ph.) meter for Rural area No.
painting consumer no. on MMB (Urban) (with
letter size height 40mm* width 8mm)
painting consumer no. on MMB (Rural) (with
letter size height 40mm* width 8mm)
Replacement of deteriorated Single phase
Fixing of new dist. Box with complete wiring
including clamps,nut bolts etc.
Reparing of guarding involving reshaping of
bearer wire cross lacing binding etc.
Painting of steel fabricated material of RSJ DO
DP structure with paint
Painting of steel fabricated material of RSJ pole
26 9924000028 mounted transformer double pole structure with No.
Painting of steel fabricated material of RSJ
single pole with paint
painting of steel fabricated material of PSC
Single pole (HT line) with paint
painting of steel fabricated material of PSC DO
DP double pole with paint
painting of steel fabricated material of PSC
30 9924000032 double pole at pole mounted transformer with No.
31 9924000033 Providing line seperater single phase No.
32 9924000034 Providing line seperater three phase No.
Replacement / Providing of stay insulator along
with adjustment of tension in stay wire
Replacement of deteriorated /providing LT dist.
34 9924000036 Box with new up to 100KVA capacity & crediting No.
Replacement of deteriorated /providing LT dist.
35 9924000037 Box with new above 100KVA capacity & No.
crediting it to store.
36 9924000038 Adjustment of tension in stay wire No.
37 9924000039 Refitting of LA No.
Converting pin point to Shackle point including
38 9924000040 location
dismentaling & restringing etc.
replacement of 11KV Pin insulator with providing
new double pin binding
replacement of 22KV Pin insulator by new 11kv
40 9924000042 pin insulator with spares & providing new double No.
Providing 11kv double disc insulators with
binding & restringing
Replacement of existing 11kv conductor (all size)
with new double pin binding
Plumbing of PSC Pole with straightening at pin
Plumbing of PSC Pole with straightening at
Plumbing of tilted DP structure (PSC/RSJ/STP)
with refilling of stone Murrum etc.
Providing new 11kv AB /GO switch with
46 9924000049 fabrication and insulated colour code jumper, Set
binding, lugs etc
Replacement of old 11kv AB /GO switch with
providing new insulated jumper, binding, lugs etc
Providing cage type loop guard in verticle LT line
48 9924000052 per pole
with using PVC reel insulators etc
Labour charges for replacement /providing of
49 9924000053 MMB & service with all accessories for three No.
phase connection
Labour charges for replacement /providing of
50 9924000054 MMB & service with all accessories for single No.
phase connection
Dismentalling of existing Dist.X'mer center(RSJ
51 9924000055 /STP POLE) 25/63/100/200 KVA with all No.
fabrication & creditig the old material to store
Disconnection from LT pole 1 phase
Reconnection from LT pole 1 phase
( payment after receipt of R/C charges)
54 9924000058 Disconnection from LT pole 3 phase No.
Reconnection from LT pole 3 phase
( payment after receipt of R/C charges)
Dismentaling & removing of service line from
pole & crediting to S/dn (1 ph.)
Dismentaling & removing of service line from
pole & crediting to S/dn (3 ph.)
Reconnection of service line complete with PVC
Reconnection of service line complete with PVC
Providing spiral type earthing by G.I. NO
8(weight 2kg -5mtr in length) with salt and coal
10kg each, including pvc rigid pipe 20mm dia(
1.5mtr length) to pass exposed part of G.I. wire
at consumer end with all materials, earth
resistance should be less than 2 ohms
Providing and fixing of signle core 1.5 sq mm
single strand copper insulated cable with cable
nail clip for spiral type earthing at consumer end.
The end of G.I. no 8 is to be connected by
connector with copper cable of which other end
61 9924000070 per meter
shall be connected to the earth terminal of meter
box. This item shall be used in location where
there is more distance between earth terminal
and earthing terminal of meter. (All materials
supplied by contractor)
Providing and fixing of FRP fencing of 1500mm height at
Distribution Transformer Centers with necessary
excavation, concreting for grouting vertical posts up to
450 mm in ground, Hardware, accessories, fittings, lock,
etc. complete as shown in specifications and drawing
enclosed. The fencing shall comprise of one gate
mm wide having two flaps and payment for the same
shall be measured on Rmt basis.
Inside fencing area to be levelled properly first by
compaction above road level and then finished
with 6” thick 1:2:4 cement concrete & cement
plaster supported with 6” brick wall on
surrounding.(Materials to be utilized :Cement
Bags, Bricks, Sand & Aggregates)
Schedule-B for Work of ARC for Erection & Maintenance of HT/LT Line and TC work and other maintenance work O/H & UG XLPE
Cable & Laying of underground cable network with terminations in the area of DGVCL under all scheme for all Sub division
under Rander Division.
Item Code Description Unit FY 2024-25
Labour charge for excavation of cable trench of 400mm width x 1200mm depth,
in any type of soil for laying of cable of size up to 240 mm2 (For additional cable
200 mm additional width shall be considered i.e. half trench length is to be
Labour charge for excavation of cable trench of 600mm width x 1200mm depth,
in any type of soil for laying of cable of size up to 240 mm2 (For additional cable
200 mm additional width shall be considered i.e. half trench length is to be
Labour charge for excavation of cable trench of 400mm width x 1500mm depth,
in any type of soil for laying of cable of size up to 240 mm2 (For additional cable
200 mm additional width shall be considered i.e. half trench length is to be
Labour charge for laying of 11kV / 22 kV XLPE Cable of size up to 240 mm2 &
preparation of sand layer 100mm thick, in the cable trench & covering the cable
with 150 mm dia (Inner), thickness 25 mm, 1.0 meter long RCC half round
muffs and providing and fixing of 4inch width yellow colour polyethylene tape with
printing "CAUTION ELECTRIC CABLE BELOW" at 0.75 m depth from ground
surface after laying cable in trench. This will provide indication that electric cable
is passing underground so as to protect cable from mechnical injuries, refilling the
same, as per Instruction of Engineer in Charge (EIC).
Labour charge for horizontal drilling using Auger machine without damage to
surface road at max 2.0 mtrs depth & putting of 6.11 kg/cm2 , class-4,Green
color, 110mm O.D. , 8.5mm thickness H.D.P.E. pipe confirms to IS 4984-
1987(3rd revision) and BIS certification and laying of 11KV/22KV XLPE cable of
5 9925000005 size up to 240 mm2 in HDPE pipe, as per Site Condition (excluding cost of pipe). Meter
The detail map obtained from HDD machine and excell sheet(hard and soft copy)
indicating the respective depth and distance from adjacent landmark for each
segment for HDD is must required to be submitted. HDD to be carried out at
depth 1.5 mtrs to 2.0 mtrs as per site conditions and as per instruction of EIC.
Labour charge for horizontal drilling manually without damage to surface road
at max 2.0 mtrs depth & putting of 6.11 kg/cm2 , class-4,Green color, 110mm
O.D. , 8.5mm thickness H.D.P.E. pipe confirms to IS 4984-1987(3rd revision) and
BIS certification and laying of 11KV/22KV XLPE cable of size up to 240 mm2
6 9925000006 size, as per Site Condition (excluding cost of pipe). The detail map and excell Meter
sheet(hard and soft copy) indicating the respective depth and distance from
adjacent landmark for each segment of cable to be submitted. Drilling to be
carried out at depth Minimum 1.2 mtrs to 2.0 mtrs as per site conditions as per
instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green color, 110mm O.D. , 8.5 mm thickness
7 9925000007 H.D.P.E. pipe confirms to IS 4984 and BIS certification for laying of underground Meter
11KV / 22KV XLPE cable up to 240 mm2 size.
Labour work for RCC concreting on disputed location and repairing of damage
8 9925000008 portion of road crossing for the work carried out for roads crossing as well as CMT
concreting & muffing of ploes including all materials (1:2:4)
Item Code Description Unit FY 2024-25
Providing & fixing concrete stone route marker of 300 mm width x 150 mm thick
x 650 mm height embedded in earth at least 300 mm below & 350 mm above
ground level respectively at distance approx 50 meters along the length of cable.
The RCC concreting (1:2:4)(all necessary maeterials will be in bidder's scope) of
route marker is to be carried out 300 mm width x 150 mm thick x 300 mm below
9 9925000009 ground level as per instruction of EIC. The route marker should be with name No.
of company with approved yellow colour-DGVCL. The distance from marker to
cable and cable depth with feeder name etc., marked with arrow sign is to be
painted on it.The route marker is to be fixed at location near to any fixed
permanent location (not necessary to fix exact on top of cable) as per instruction
Erection of D.P. (double pole) structure using 9 / 11 Mtr. RSJ pole with cable
connection arrangement along with fitting of necessary fabrication for 11KV cable
including excavation of pit & refilling of earth as per instruction of EIC. (Exclusive
of concreting & muffing of poles)
Erection of Single pole structure using 9 / 11 Mtr RSJ pole with cable
connection arrangement along with fitting ofnecessary fabrication for 11KV/22 KV
cable including excavation of pit & refilling of earth as per instruction of EIC.
(Exclusive of concreting & muffing of poles)
Erection of D.P. (double pole) structure using 8.0 Mtr. PSC pole with cable
connection arrangement along with fitting of necessary fabrication for 11KV cable
including excavation of pit & refilling of earth as per instruction of EIC. (Exclusive
of concreting & muffing of poles)
Erection of Single pole structure using 8.0 Mtr PSC pole with cable connection
arrangement along with fitting ofnecessary fabrication for 11KV/22 KV cable
including excavation of pit & refilling of earth as per instruction of EIC. (Exclusive
of concreting & muffing of poles)
Labour charge for erecting of 11kV / 22 kV XLPE cable of size up to 240 mm2
14 9925000014 on DP Structure with fixing of 02 Nos polymer cleats on top and middle Per Job
part.Polymer cleats, nut bolts etc. fixing material to be provided by contractor.
Providing & fixing of 6.11kg/cm2 , class-4,Green color, 110mm O.D. , 8.5mm
thickness H.D.P.E. pipe confirms to IS 4984 and BIS certification on the
erected DP structure for the mechanical protection of cable by inserting the
15 9925000015 cable inside HDPE pipe. The HDPE pipe shall be erected in such a way that Per Job
300mm shall be below the ground level and the rest 2700 mm shall be
supported on the DP Structure with 01 No Polymer cleat.All materials including
polymer cleat and Nut bolt to be provided by contractor.
Providing and fixing of pipe type earthing from 80 mm dia class-B GI pipe with
pit to be filled with salt & coke and construction of chamber as per DGVCL Drg.
16 9925000016 No. dg /100 for DP and cable. The earthing pit should be joined with cable by G.I. No.
strip of size 1” width & 2 mm thick. All material GI pipe, Coke, Salt etc will be
supplied by bidder.
Supply & fixing of heat shrink type end terminations (outdoor) for upto
11kV 3C x 185 mm size XLPE cable as per DGVCL technical specification
Supply & fixing of heat & shrinkable end terminations (outdoor) for upto 22 kV
3C x 185 mm2 size XLPE cable as per DGVCL technical specification)
Supply & fixing of heat shrink type end terminations (indoor) for upto 11kV 3C
x 185 mm2 size XLPE cable as per DGVCL technical specification)
Supply & fixing of heat & shrinkable end terminations (indoor) for upto 22 kV
3C x 185 mm2 size XLPE cable as per DGVCL technical specification
Supply & fixing of heat shrinkable straight through joint for upto 11kV 3C x
185 mm2 size XLPE cableas per DGVCL technical specification.
Supply & fixing of heat shrinkable straight through joint type for upto 22kV 3C
x 185 mm2 size XLPE cable as per DGVCL technical specification
Labour charge for excavation of 2100mm long x 1200mm wide x 1200 mm deep
joint pits for installation of 11kV / 22kV Straight through joints as per
23 9925000023 instruction of engineer-in-charge & covering the cable with 150 mm dia (Outer), No.
thickness 25 mm, 1.0 meter long RCC half round muffs & refilling same as per
instruction of EIC .
Item Code Description Unit FY 2024-25
Providing and fixing of insulating bus bar, made from 11KV/22KV XLPE cable
after removal of semi conducting layer and applying of PVC heat shrinkable anti-
tracking core insulating tubing (1.1KV), on both end terminal using Aluminium
long barrel heavy duty up to 240 sq mm lugs, Aluminium bus connector. Taping
with PG- clamp for bus conductor as per drawing and as per instruction of EIC.
The Alluminium lugs and PG clamp shall be covered with 11KV/22KV HT
insulating tapes.(11KV/22KV XLPE cable will be in scope of DGVCL while all
other materials will be in bidder's scope)
Testing of cable at various points and commissioning the feeder as per
25 9925000025 instruction of engineer-in-charge.Test result shall be submitted by contractor with No.
Preparation and submission of 6 (six) copies, of complete layout drawings with
26 9925000026 GIS mapping as per actual cable routing showing road crossing, HDPE pipe Set
sleeving, jointing locations, markers etc.
Providing and fixing of Sign Board at junction point Made out of 2 mm aluminium
sheet size 750x300 mm (2.5 x 1ft) rectangle, as per design, pre treated with
phosphate process and acid etching coated with one coat of epoxy primer and
two coats of best quality paints, refloctrorised with Hi-Intensity retro – reflective
sheeting as per the latest and frame fabricated from suitable size iron angle. The
Sign Board is to be fixed on the base prepared from channel and bracing angles
which is grouted by means of cement concreting of 1:2:4 for size of 300 mm dia x
800 mm height (500 mm to be grouted in ground). The details to be displayed on
sign board will be given by In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing and fixing of Sign Board (Danger Board) on Distribution Transformer
Made out of 2mm aluminium sheet size 300x300mm (1x1ft) as per design, pre
treated with phosphate process and acid etching coated with one coat of epoxy
28 9925000028 primer and two coats of best quality paints, refloctrorised with Hi-Intensity retro- No.
reflective sheeting as per the latest and frame fabricated from suitable size iron
angle. The Sign Board (Danger Board is to be fixed at the location as per
instruction of In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing & fixing of aluminium tag of size 250 mm (L) x 75 mm (W) from 3 mm
aluminium sheet along with 1.0 mm dia aluminium binding wire for fixing of
29 9925000029 aluminium tag near end termination joint at DP structure for identifyng the cable. No.
The details of feeder i.e. 11 / 22 KV with feeder name shound be punched on the
tag by letter punch of size 16 mm as per instruction of In-charge Engineer.
Supply & fixing of heat shrink type end terminations (outdoor) for 11kV 3C x
240 mm2 size XLPE cable as per DGVCL technical specification
Supply & fixing of heat & shrinkable end terminations (outdoor) for 22 kV 3C x
240 mm2 size XLPE cable as per DGVCL technical specification)
Supply & fixing of heat shrink type end terminations (indoor) for 11kV 3C x
240 mm2 size XLPE cable as per DGVCL technical specification)
Supply & fixing of heat & shrinkable end terminations (indoor) for 22 kV 3C x
240 mm2 size XLPE cable as per DGVCL technical specification
Supply & fixing of heat shrinkable straight through joint for 11kV 3C x
mm2 size XLPE cableas per DGVCL technical specification.
Supply & fixing of heat shrinkable straight through joint type for 22kV 3C x
mm2 size XLPE cable as per DGVCL technical specification
Installation, Testing and commissioning of 11 KV,630 A SCADA Compatible,
36 9925000038 RRL type- 3 Way RMU including Two numbers of earthings as per Drawing No.
(material is in bidder's scope) and as per DGVCL Technical specification.
Installation, Testing and commissioning of 11 KV,630 A SCADA Compatible,
37 9925000039 RRLL type- 4 Way RMU including Two numbers of earthings as per Drawing No.
(material is in bidder's scope) and as per DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A SCADA Compatible, RRL
38 9925000040 type-3 Way, RMU including Two numbers of earthings as per Drawing (material No.
is in bidder's scope) and as per DGVCL Technical specification.
Item Code Description Unit FY 2024-25
Installation, Testing and commissioning of 22KV,630 A SCADA Compatible,
39 9925000041 RRLL type-4 Way, RMU including Two numbers of earthings as per Drawing No.
(material is in bidder's scope) and as per DGVCL Technical specification.
Construction of plinth for 11KV, RRL type- 3 Way (i.e Two numbers of Isolator
& One number of Breaker) Ring Main Unit as per DGVCL's technical
specification mentioned in drawing no: Drg. 11kv-01. All required material will be
supplied by contractor.
Construction of plinth for 11KV, RRLL type- 4 Way (i.e Two numbers of
Isolator & Two number of Breaker)Ring Main Unit as per DGVCL's technical
specification mentioned in drawing no:Drg. 11kv-02.All required material will be
supplied by contractor.
Construction of plinth for 22KV, RRL type- 3 Way (i.e Two numbers of Isolator
& One number of Breaker) Ring Main Unit as per DGVCL's technical
specification mentioned in drawing no: Drg. 22kv-01. All required material will be
supplied by contractor.
Construction of plinth for 22KV, RRLL type- 4 Way (i.e Two numbers of
Isolator & Two number of Breaker)Ring Main Unit as per DGVCL's technical
specification mentioned in drawing no:Drg. 22kv-02.All required material will be
supplied by contractor.
Modifications e.g.Providing and fixing of Terminal protectors i.e. Re-use able boot
(HT Side 11/22KV, LT Side 1.1KV) including 11/22 KV insulating taps and
L.T.(1.1 KV) insulating taps ,Busbar, Tapping from Bus Bar (11/22 KV XLPE
cable) through P.G. Clamp for H.T. Jumper to D.O. Fuse to bushings of
Transformer Center, providing & Fixing of jumper and providing & fixing of Heat
Shrinkable Anti Tracking Core Insulating Tubing (Insulation Level 11/22 KV) in
H.T. jumper , Clamping arrangement of cable support frame on both side of
44 9925000046 existing Over Head type Distribution Transformer to utilize in Under Ground No.
cable network as per drawing & as per instruction of Engineer incharge. All live
parts i.e. PG-Clamp, connections of D.O.fuses, HT bushings etc . shall be
covered with fixinng of 11/22 KV HT insulating tapes. ( 11/22 KV XLPE cable will
be in scope of DGVCL while all other materials will be in bidder's scope ) .
Laying of any size of 11/ 22 KV XLPE /PILC Cable in redaymade trench or in
46 9925000060 Labour charges for Lying of O/H XLPE cable pole to pole KM
Supply of 150 mm dia (Inner), thickness 25 mm, 1.0 meter long RCC half round
In Words :- One Crore Rupees Only
% Above / Below of Estimate Amount
Stamp & Sign of Contractor
Executive Engineer (O&M)
DGVCL,Rander Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender 1 cr.pdf
2. ALL SDN Bid Document.pdf
3. ALL SDN Detail Tech Specification.pdf
4. Erection and Maintenance for Technical Specification.pdf
5. Schedule-b for ug all Sub division.pdf
6. Reference Bid Drawing.pdf
7.UG CABLE TENDER IMP POINTS.pdf
8. Utilization of pole erection device.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .