Loading…
Loading…
Tender Value
₹85.1 L
EMD Value
₹1.7 L
Closing Date
5 Aug 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Deposit Work
Above/Below/Par
TENDERCELL
14 conditions · 2 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annualcontractual turnover of V/N or 'V' whichever is less; where (as per letter no.2022/CEI/CT/GCC-2022/Policy dated 14-07- 2022).V= Advertised value of the tender in crores of RupeesN= Number of years prescribed for completion of work for which bids have been invited.The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria:(a) The tenderer must have successfully completed or substantially completed any one ofthe following categories of work(s) during last 07 (seven) years, ending last day ofmonth previous to the one in which tender is invited:i. Three similar works each costing not less than the amount equal to 30% of advertisedvalue of the tender, orii. Two similar works each costing not less than the amount equal to 40% of advertisedvalue of the tender, oriii. One similar work costing not less than the amount equal to 60% of advertised value ofthe tender.
Defination of Similar Work :- Wiring/Rewiring in buildings with associated electrical works. o r Lighting arrangement in buildings circulating area,yard,street etc. with associated electrical works. or Wiring/rewiring,Lighting arrangement in buildings with assoicated electrical works.
11 conditions · 7 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
General Conditions of Contract (GCC) 2022 or latest with all amendments shall be applicable.
Provision for wiring and lighting arrangement of workshop/shed area and other associated electrical works as per scope of work at RCNK/SNP.
6SEfile195874RT2-Tender
6SEfile195874RT2-Tender
Open
Works - General
6 Months
Sonipat, Haryana
₹0
₹1.7 L
5 Aug 2026
14 Jul 2026
22 Jul 2026
51 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 85,14,156.22 | ||
| — | 2200.00 | — | — | ||
| Supply and fixing of steel conduit along with accessories in surface/recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required of size 25 mm as per IS standard and acceptable to railway for wiring. | — | — | — | 5,63,200 | |
| — | 40.00 | — | — | ||
| Hiring of crane with cage for execution of work to be executed at height. (Approximate 20 days to fix High bay light + 20 Days to fix conduit and wiring). | — | — | — | 1,56,000 | |
| — | 3600.00 | — | — | ||
| Supply, fixing, testing and commissioning of PVC insulated multi stranded copper conductor single core cable confirming to IS:694(latest version) & drawing & laid (recessed& surface); MS/PVC conduit pipe for wiring at point wiring/Circuit wiring/sub main /main as Supply of PVC insulated multi stranded copper conductor single core cable confirming to IS:694(latest version) & drawing & laid (recessed& surface) in MS/PVC conduit pipe for wiring at point wiring/Circuit wiring/sub main /main as required. As per technical specification ii) 4.0 sq mm required. | — | — | — | 1,25,928 | |
| — | 15000.00 | — | — | ||
| Supply, fixing, testing and commissioning of PVC insulated multi stranded copper conductor single core cable confirming to IS:694(latest version) & drawing & laid (recessed& surface) in MS/PVC conduit pipe for wiring at point wiring/Circuit wiring/sub main /main as required. As per technical specification I) 2.5 sqmm | — | — | — | 3,45,900 | |
| — | 1500.00 | — | — | ||
| Supply and erection of 25 MM GI pipe class' B' ISI marked with accessories including clamps, bends etc. to support the cable with erected pole/recessing in wall/floor/passing earth strip | — | — | — | 2,97,000 | |
| — | 150.00 | — | — | ||
| Supply of LED Highbay overhead light 200 watt with suitable clamp for fixing of light. The LED based light(lamp) shall be of make Phillips, Bajaj, Havells or similar conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest. | — | — | — | 16,45,500 | |
| — | 150.00 | — | — | ||
| Installation, commissioning, connection and testing of item No. 6 | — | — | — | 3,29,100 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of 16/20 watt LED pit light. | — | — | — | 1,06,058 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing and commissioning of 36-watt LED Panel Light of extruded aluminium frame size 2x2. The LED based light(lamp) shall be of make Phillips, Bajaj, Havells or similar conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec- I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest. | — | — | — | 22,420 | |
| — | 70.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaire, having system wattage. 2x18W. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. The LED based 4 ft. tube light(lamp) shall be of make Phillips, Bajaj, Havells or similar conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest. | — | — | — | 34,440 | |
| — | 35.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED flood light luminaire, having system wattage 250W. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. The LED based 4 ft. tube light(lamp) shall be of make Phillips, Bajaj, Havells or similar conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest. | — | — | — | 5,38,650 | |
| — | 50.00 | — | — | ||
| Supply,fixing,tesing and commissioning of Garden light bollard type is environmental friendly energy efficient, aluminium body material, powder coated IP65 rating, color temp 3000k, 220-240V AC input voltage,50-60Hz frequency may be similar of model no-CDI-BL4-500. Make Havells /Bajaj/Philips/ Crompton/Syska or similar conforming to CEE/NR's spec. No. CEE/NR/121- Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121- Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest. | — | — | — | 2,27,999 | |
| — | 250.00 | — | — | ||
| Supply, fixing, testing and commissioning of 3 pin, 5A ceiling rose on the junction box | — | — | — | 8,045 | |
| — | 150.00 | — | — | ||
| Supply of 750 mm sweep air circulating fan. | — | — | — | 10,60,230 | |
| — | 150.00 | — | — | ||
| Installation (fixture to be fixed on iron column including welding of supporting fixture), commissioning, connection and testing of item No. 14 | — | — | — | 2,12,046 | |
| — | 40.00 | — | — | ||
| Supply, fixing, testing and commissioning of three phase street light timer panel based on photo voltaic sensor complete made up of steel sheet, phosphatised powder painted complete with neutral link, earth point, Din rail and prewired confirming to IS:13032 & 8623:1991 with contractor to be fixed on wall, iron column, feeder pillar suitable for both outdoor/indoor with digital measuring instrument. | — | — | — | 9,11,520 | |
| — | 30.00 | — | — | ||
| Supply, fixing, testing and commissioning of LT distribution board double door type made up of steel sheet, phosphatised powder painted complete with neutral link, earth point, Din rail and prewired confirming to IS:13032 & 8623:1991 of make Havells, Siemens, L&T, Schneider, Legrand or equivalent with following items of matching make to be fixed in distribution board, confirming toIS:8828 :1996 or latest, IE rules and site requirement. 4P MCB 63Amps. 10 kA 'C' series=01 No. (Incoming) SP MCB6-32 Amps. 10 kA 'C' series = 18 Nos. (Outgoing) | — | — | — | 2,98,637.1 | |
| — | 1500.00 | — | — | ||
| S/F/T & C of 8 SWG GI wire as per site requirement. | — | — | — | 12,615 | |
| — | 40.00 | — | — | ||
| Earthing with G.I. earth pipe minimum 4.5-metre-long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required, as per IS, IE rule and site requirement. | — | — | — | 2,08,917.2 | |
| — | 1.00 | — | — | ||
| Supply, Erection, testing and commissioning of 16 Mtrs. High mast tower along with 06 nos. of 200 W LED flood light luminaires as per CEE specification | — | — | — | 4,06,443.92 | |
| — | 200.00 | — | — | ||
| Design, supply, installation, testing and commissioning of 3D letter signage board. | — | — | — | 1,76,138 | |
| — | 25.00 | — | — | ||
| Supply, installation, testing and commissioning of wall mounted bracket Fan of Sweep 400 mm with all necessary accessories. | — | — | — | 78,529 | |
| — | 2000.00 | — | — | ||
| Supply of commissioning of 4 core 25 Sq. mm XLPE armoured cable | — | — | — | 3,06,840 | |
| — | 1000.00 | — | — | ||
| Laying of One Number additional PVC insulated and PVC Sheathed/XLPE power cable of 1.1 KV grade of 4 core 25 Sq mm in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. | — | — | — | 3,87,000 | |
| — | 1000.00 | — | — | ||
| Laying of One Number additional PVC insulated and PVC Sheathed/XLPE power cable of 1.1 KV grade of 4 core 25 Sq mm in on wall as required. | — | — | — | 55,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCACS1to11Merged.pdf
ATTACHMENT
Tenderdocumentforapproval.pdf Tender Documents for approval
ATTACHMENT
GCC-2022.pdf
ATTACHMENT
Tenderdocumentforapproval.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .