Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.5 LAccepted-AOC 508 1ST FLOOR DR MUKHERJEE NAGAR DELHI 110009 | NORTH | DELHI | 110009 | 1 | Accepted-AOC L1 BIDDER |
Tender Value
₹4.7 L
EMD Value
₹9,450
Closing Date
13 Jan 2022, 10:00 amClosed
EX. ENGINEER (ELECT)-I
OFFICE OF THE EX. ENGINEER (ELECT)-I UNDER GROUND CAR PARKING ASAF ALI ROAD, DELHI-110002
Improvement of Electrical installation in Wards, Labour Room and Casulty at Mrs GLM Hospital in Wad No 88 under CSP Zone
2022_NDMC_100972_1
39/MWEEE-I/2021-22/TC
Open Tender
Electrical Works
Item Rate
30 days
City SP Zone
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
₹9,450
30 Apr 2022
7 Jan 2022
14 Jan 2022
7 Jan 2022
13 Jan 2022
7 Jan 2022
Amount
Wiring for light point /fan point /exhaust fan point /call ball point with 1.5sq.mm FRLS PVC installed copper conductor single core cable in surface / recessed PVC conduit, with piano type switch phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5sq.mm. FRLS PVC installed copper conductor single core cable etc as required. Group C
Rewiring for light point /fan point /exhaust fan point /call ball point with 1.5sq.mm FRLS PVC insulated copper conductor single core cableas earth wire in existing surface/recessed steel/ pvc conduit i/c dismentaling as reqd. etc as required. Group C
Supplying & fixing metal box of 180mm X 100mm X 60mm deep(nominal size) on surface or recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6pin 5/6 &15/16 amps socket outlet and piano type switch, connection painting etc. as required
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 200 mm X 300 mm X 100 mm deep
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (A) 12 Way Double door
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (A) 25 mm
Supplying and fixing 5amps,to 32 amps rating, 240 volts, "C" curve miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection testing and commissioning etc, as required. (A) Single Pole
Supply and fixing following rating, double pole, 240 volt, isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. (A) 63 Amp.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Laying of one number pvc insulated and PVC sheathed/ XLPE power cable of 1.1 kv grade of following size in the existing surface as required Upto 35 sq. mm (clamped with 1mm thick saddle)
S/I/T/C of LED tube type luminaire 20 watt rating complete with extruded aluminium batten prewired with high efficient LEDs with the following : Total system wattage = 60 watt + - 5 % Luminous efficacy lumens/watt >=95 Power factor >=0.95
S.I.T.C. of 60 w LED Flood light fixture fitted with lense made of pressure die cast aluminium housing and Toughened glass cover comlete with following specifaction as reqd. Lumnairer efficacy >= 100 luman/watt Power Factor>= 0.95 protection Class- IP-66
Supply and fixing of following piano type swich/ socket on the existing switch box/ cover including connection etc as required. 5/6amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
Supply of following size 1400 rpm heavy duty Exaust Fan complete with ring, blade etc as required. ISI marked. 12'' (300 MM)
Supply & Fixing of phenolic laminated 3 mm thick sheet i/c cutting as reqd.
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubical panel making connection, etc as required 100 Amp, 16KA TPMCCB
Supply of PVC/XLPE insulated PVC/XLPE sheathed Al. conductor armoured cable for working voltage up to 1.1 kv confirming to IS 7098(part-1) of following size 4 X 25 sqmm
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .