Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-Finance | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹27.7 L+₹3.8 L (15.8%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹28.8 L+₹4.9 L (20.5%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹29.3 L+₹5.3 L (22.3%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹29.4 L+₹5.5 L (22.8%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
Tender Value
₹42.9 L
EMD Value
₹85,740
Closing Date
27 Nov 2024, 6:00 pmClosed
GE (I) DM, Visakhapatnam
GE (I) DM, Visakhapatnam
DAY TO DAY MAINTENANCE, ATTENDING BREAKDOWNS AND CALL ON REPAIRS FOR 24 HRS FOR SECURITY LIGHT, HIGH MAST LIGHT, DOCK LIGHT, TOWER LIGHT AND AREA LIGHT, REPLACEMENT OF UNSV CABLES, SECURITY LIGHTS, FLOOD LIGHTS, CONTROL GEAR, OTHER FIXTURES AT JETTY
2024_MES_682652_1
8142/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Naval Dockyard Visakhapatnam
As per tender documents
8 documents required · 8 mandatory
₹500
GE (I) DM, Visakhapatnam
₹85,740
Yes
7 Feb 2025
6 Nov 2024
29 Nov 2024
6 Nov 2024
27 Nov 2024
20 Nov 2024
Amount
Attending day to day complaints and call on repair of street lights at jetty area including lights on pole, tower, high mast, and on ground or on wall by pitting suitable man power not less than one electrician and one helper for all days including Holidays & Sundays for the following item of work:- (a) To check timer panel for proper functioning. (b) To check main control switch gear from substation or distribuiton pillar boxes for proper functioning.. (c) To check junction boxes or poles/tower /highmast for proper cable connection for proper functioning.. (d) To check 3 pole contractor & decarbonising of contact points for proper functioning. (e) To check LT cable from main switchgear to street light Junction board for proper functioning.
Supply and fixing PVC insulated, PVC round sheathed copper flexible electric cable 6 sqmm 6 core, 1100 Volts grade and dismantling wornout/defective cables from top of highmast light to bottom control panel, through high mast pole complete all as specified and as directed.
Supply and fixing PVC insulated, PVC round sheathed copper flexible electric cable 1.5 sqmm 3 core, 1100 Volts grade and dismantling wornout/defective cables from SL/Flood light fitting at pole top to JB at bottom of pole, through pole. complete all as specified and as directed.
Supply and fixing PVC insulated, PVC round sheathed copper flexible electric cable 2.5 sqmm 3 core, 1100 Volts grade and dismantling wornout/defective cables from SL/Flood light fitting at pole top to JB at bottom of pole, through pole. complete all as specified and as directed.
Supply and fixing PVC XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade cross section area 6 Sqmm 2 core including dismantling taking down unsv one from trench/gallery/tower. complete all as specified and as directed.
Supply and fixing PVC XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade cross section area 10 Sqmm 4 core including dismantling taking down unsv one from trench/gallery/tower complete all as specified and as directed.
All as per item No 6.00 above, but of Size 16 Sqmm 4 core.
All as per item No 6.00 above but of Size 25 Sqmm 4 core.
Supply and fix contactor 3 phase, 415V, upto 70 Amps capacity utilised for heavy duty by taking down the old unserviceable contactor complete all as specified and as directed.
Supply and fixing HDPE double wall pipe of size 40 mm dia for cable protection laid in trenches/ Round corners/ pole including dismantling taking down old unserviceable one complete all as specified and directed.
Supply and fix surface mounting Analog time switches heavy duty of 230 V 50Hz including dismantling taking down unsv one and complete all as specified and as directed
Supply and fix MCB, SP, 10KA, 'C Curve' 6-32 A including dismantling taking down old unserviceable one complete all as specified and as directed.
Supply and fix MCB,TPN, 10KA, 'C Curve' 40A-63 A including dismantling taking down old unserviceable one complete all as specified and as directed.
Supply and fix MCCB with thermal magnetic release, 16 KA, 4 pole, 415V, 16A to 100 A complete all as specified and as directed.
All as per item No 14.00 but of capacity 125Amps 4pole 415V.
Taking down old unserviceable aviation light fitting and supply & fix new LED aviation light fitting with clamps, nuts, bolts and service connections up to the junction box complete all as sepcified and as directed
Taking down old unserviceable aviation light fitting Angle Iron Brackets and supply & fix new Angle Iron Brackets fitting with clamps, nuts, bolts and PCC Foundation size 1X1 Ft complete all as sepcified and as directed
Supply & fix 4 Sqmm 4 core copper flexible Cable including dismantling taking down unsv one on jetty complete all as sepcified and as directed
S&F PVC junction box of outdoor type, weather proof, with provision of hole at bottom for cable entry, hinged door with locking arrangement, of size not less than 200mm (L) x 100mm(B) x 300mm (H) incl taking down unserviceable one, fixed to pole with MS clamp, nuts, bolts and washers complete including complete connection all as specified and directed. Make- Syntex / Hansel
Supply & fix Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sq. cm PVC Pipe size 25mm complete all as sepcified and as directed
Supply & fix Second Class Hard wood flants for Towers of 25mm thick incl taking down unserviceable one, fixed to pole with MS clamp, nuts, bolts and washers complete all as specified and directed.
Taking down old unserviceable LED Street light from any height of Tower/Ring pole supply and fixing LED Street light 120 Watt. complete all as specified and as directed
Taking down old unserviceable Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specfied and directed.
Taking down old unserviceable LED Flood light from any height of Tower/Ring pole/Hight Mast and supply and fixing LED flood light fitting 250 W with clamps, nuts, bolts and service connections up to the junction box complete all as specified and as directed
Taking down old unserviceable LED Flood light from any height of Tower/Ring pole/Hight Mast and supply and fixing LED flood light fitting 300W with clamps, nuts, bolts and service connections up to the junction box complete all as specified and as directed. MAKE-HAVELLS Cat No-JETAIRISMA XFL300WLED757PWBLTG
Material & labour for servicing of high mast tower control mechanism by greasing and varnishing of electric motor 2 HP, 3 phase 415 volts 50Hz including replacement of unsv Gear Wheel & Chain for trouble free functioning including painting of GearBox & Motor Mechanism with one coat of synthetic enamel paint complete all as specified and as directed.
Material & labour for servicing, repair, maintenance of Timer Panel including replacement of burnt MCCB, Contactor, Timer, Control wiring for trouble free functioning including cleaning inside and outside, painting of Timer Panel with one coat of synthetic enamel paint & necessary welding works complete all as specified and as directed. Note: Replacement of MCCB, MCB, Timer, Contactor shall be measured as supply only.
Supply only LED driver suitable for street light / flood light fitting as per existing make of fitting, 230V, 120 watt complete all as specified and as directed
Supply only LED driver suitable for street light / flood light fitting as per existing make of fitting, 230V, 250 watt complete all as specified and as directed
Supply only LED driver suitable for street light / flood light fitting as per existing make of fitting, 230V, 300 watt complete all as specified and as directed
S&F control panel outdoor type made with 3mm thick MS sheet of size (LxWxH) 650mm x 400mm x 650mm provision of Timer contact MCCB, door locking arrangement, with powder coating including PCC foundation all as specified and as directed.
M&L for dismantling of old unsv bollard lights and supply & fixing of Bollard light 9W fittings(latest Model) complete all as specified and as directed
M&L for dismantling of old unsv Water proof lights and supply & fixing of Water proof light 9W fittings(latest Model) complete all as specified and as directed
M&L for dismantling of 2HP High Mast tower motor and supply, fixing, testing & commsioning of 2HP motor 3ph 415V 50Hz complete all as specified and as directed.
M&L for painting of steel fabricated light tower not less than 10 mtr high with one coat of aluminium paint after preparation of complete surface complete surface including writing tower number with synthetic enamel black paint complete all as specified and as directed.
M&L for painting of steel tubular pole any type / swan neck pole with one coat of aluminium paint after preparation of complete surface complete surface including writing Pole number with synthetic enamel black paint complete all as specified and as directed.
M&L for dismatling and taking out street light cable loop near pole for size of cable 6sqmm to 25 sqmm after dismantling connection from junction box, cutting, removing damaged portion of the cable ends, providing new aluminium cable end terminals, laying of cable through protection pipe through coping to junction box including necessary connection complete all as specified and directed. Note: HDPE pipe shall be measured separately.
S&F Street light time light distribution board timer panel heavy duty timer with all assy including dismantling taking down old unsv one complete all as specified and directed.
M&L for white washing of PCC foundation of Street light pole/Ring pole/ Highmast tower on every alternate 3 month complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth in depth for laying of cable and getting out soft/loose soil complete all as specified and directed.
M & L for filling dry sand,spread & compacting for sand cushioning of under ground cable all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.compelete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point compelete all as specified and directed.
Supply and laying well burnt bricks sub class 'B' laid breath wise along the length of cable in trench for underground cable protection complete all as specified and directed.
M&L Steel tubular swaged poles complete with MS base plate including fixing arrengement & FOSROC chemical PCC Cop point on Jetty, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (9.0 metres long) complete including taking down all as specified and directed.
M&L Steel tubular ring poles complete with cast iron base plate, including fixing arrengement & FOSROC chemical PCC Coping on Jetty, finial taper plug, bolts, nuts and screws as specified,type 410 SP-64 (12.0 metres long) complete including taking down all as specified and directed.
SAI ENGINEERING WORKS (BID ID -3173346)
R AND A ASSOCIATES ENGINEERS CONTRACTORS (BID ID -3175061)
SAI SREENIVASA ENGINEERING (BID ID -3174866)
B.Veerabhadra Rao (BID ID -3174794)
GVR CONSTRUCTIONS (BID ID -3175428)
S.S.TRADERS (BID ID -3175325)
aswitha engineering works (BID ID -3175352)
EMKAY ENGINEERING CONSTRUCTIONS (BID ID -3175175)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .