Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹28.9 L+₹2,125 (0.07%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹32.7 L+₹3.8 L (13.2%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder |
| Sl No | Description | Qty | Unit | KRISHNA ENGINEERING ENTERPRISES L1 | M/S JIWAN SINGH L3 | narayan construction L2 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for repairs /servicing to existing LT electric panels outdoor type including checking loose connections and tight coonection and cleaning inside /outside all connection, replacing all cable glands, thimbles and lugs as per the size of existing cable, providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it serviceable, spray painting and testing the entire panel board after the complete servicing upto the satisfaction of Engr-in-Charge and complete all as specified and directed.
Note:- The rate quoted per unit shall deemed to be inclusive of taking out burnt MCB/MCCB/Voltmeter/Ammeter/CT/Busbar/LED indicating lamps of any type and any description etc and refixing the same. New items shall be measured and paid separately as supply only under respective items of BOQ.
(i) Cleaning inside the panel and all incoming and outgoing feeders i.e MCCB / Changeover switches /Contactors thoroughly with help of vacucum cleaner.
(ii) Checking the loose connections of incoming and outgoing feeders and rectify the same with help of new GI nuts bolts and washers.
(iii) Replacing the burnt out colour coated PVC sleeves of main and feeders bus bar with appropriate size of new PVC heat shrinkable sleeves
(iv) Replacing burnt out voltmeters/ammeters/Indicating lamps/HRC fuses, New items shall be measured and paid separately as supply only.
(v) Replacing burnt out control wiring of ammeter /voltmeter/Indicating lamps and CT's with 2.5/1.5 Sqmm copper single core, 1100V grade copper conductor cable.
(vi) Replacing burnt out busbar of incoming and outgoing feeders with appropriate size of new bus bar, which shall be measured and paid separately.
(vii) Spray painting of panel board with one coat of synthetic enamel paint. | 18 | Each Job | 1,500 ₹27,000 | 500 ₹9,000 Lowest | 500 ₹9,000 Lowest |
| 2.00 | Supply only Aluminium bus bar strip of any size for extension of MCCB terminals for cable terminations, inside the cable alley of LT panel board duly supprted on the FRP/ DMC support insulators including necessary drilling / bending to obtained required shape and size complete all as specified and directed. | 32 | Kg | 300 ₹9,600 | 350 ₹11,200 | 200 ₹6,400 Lowest |
| 3.00 | Supply only suitable type and size of FRP/DMC bus bar support insulator (Bridge insulator) for fixing the extended aluminium / copper bars for cable termination duly fixed in the body of the panel board including galvanized steel bolts, nuts, washer etc including necessary drilling in the panel body, complete all as specified and directed. | 60 | Each | 50 ₹3,000 Lowest | 60 ₹3,600 | 50 ₹3,000 Lowest |
| 4.00 | S&F in replacement for aluminium tubular lugs of cable size 10 Sqmm to 16 Sqmm, complete all as specified and directed. | 200 | Each | 5 ₹1,000 Lowest | 10 ₹2,000 | 25 ₹5,000 |
| 5.00 | S&F in replacement for aluminium tubular lugs of cable size 25 Sqmm to 50 Sqmm, complete all as specified and directed. | 200 | Each | 10 ₹2,000 Lowest | 35 ₹7,000 | 25 ₹5,000 |
| 6.00 | S&F in replacement for aluminium tubular lugs of cable size 70 Sqmm to 120 Sqmm, complete all as specified and directed. | 200 | Each | 17 ₹3,400 Lowest | 100 ₹20,000 | 25 ₹5,000 |
| 7.00 | S&F in replacement for aluminium tubular lugs of cable size 150 Sqmm to 300 Sqmm, complete all as specified and directed. | 150 | Each | 46 ₹6,900 | 150 ₹22,500 | 25 ₹3,750 Lowest |
| 8.00 | S&F in replacement for copper lugs of cable size 10 Sqmm to 16 Sqmm, complete all as specified and directed. | 50 | Each | 7 ₹350 Lowest | 34 ₹1,700 | 25 ₹1,250 |
| 9.00 | S&F in replacement for copper lugs of cable size 25 Sqmm to 50 Sqmm, complete all as specified and directed. | 100 | Each | 43 ₹4,300 | 70 ₹7,000 | 25 ₹2,500 Lowest |
| 10.00 | S&F in replacement for copper lugs of cable size 70 Sqmm to 120 Sqmm, complete all as specified and directed. | 50 | Each | 61 ₹3,050 | 130 ₹6,500 | 25 ₹1,250 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
22 Jul 2025, 6:00 pmClosed
GE 862 EWS
GE 862 EWS PIN-913862 c/o 56 APO
REPAIR REPLACEMENT OF LT OH LINES UG CABLES LT PANELS AND CONNECTED WORKS AT DETT-III AREA AT RAJOURI KERI GALUTHI GAMBHIR DALOGRA AND CBS SAROL UNDER AGE EM OF GE 862 EWS
2025_MES_716281_1
GER-40/2025-26
Open Tender
Civil Works
Works
180 days
GE 862 EWS
As per Tender Documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹80,000
Yes
22 Aug 2025
23 Jun 2025
25 Jul 2025
23 Jun 2025
22 Jul 2025
8 Jul 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .