| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC S NO 279 1 1A PLOT NO 113 KUTWAL COLONY SASTHE WASTI LOHEGAON PUNE 411 047 | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹23.1 L+₹61,430 (2.73%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹23.5 L+₹1.0 L (4.62%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹23.8 L+₹1.4 L (6.09%)Rejected-Finance INDEX NO D 1478 CE SC PUNE PLOT NO 44 11 KACHNAYAKANHALLI VILLAGE JIGANI HOBLI ANEKAL TALUK BANGALORE PIN 560 106 KARNATAKA STATE | 560106 | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹26.2 L+₹3.7 L (16.6%)Rejected-Finance | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (I) (CG) GOA
GARRISON ENGINEER (I) (CG) GOA 403806
REPAIR AND MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY UNDER NON TECH AREA AND TECH AREA AT GOA UNDER GE(I)(CG) GOA
2024_MES_666454_1
8515/GOA/E8
Open Tender
Electrical Maintenance Service
Item Rate
180 days
GE(I) (CG) GOA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Garrison Engineer (I) (CG) Goa
₹60,000
Yes
23 Oct 2024
18 Jul 2024
19 Sept 2024
18 Jul 2024
12 Sept 2024
1 Aug 2024
Amount
Excavation in trenches n.exc 1.5 m deep and n.exc 1.5 m wide and getting out in hard dense soil for taking up/relaying LT UG cable/ pipe complete all as specified and directed.
All as per Item No 1.00 above but in soft disintegrated rock/ laterite rock complete all as specified and directed.
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata complete all as specified and directed.
Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Supply/ Lay dry river sand/ M sand in trenches for cable protection complete all as specified and directed. [Note :- Punned thickness only will be measured & Paid]
Supply and lay cable cover LV type 1 flate size 250mm x 150mm x 40mm for cable protection complete all as specified and directed.
Supply and laying un re-inforced precast concrete cable cover, class HV, type-I, flat size 300mm x 180mm x 40mm in trenches over and across the cable complete all as specified and directed.
Taking out LT/HT UG cable of any type and size from trenches/ walls etc complete all as specified and directed.
Supply laying testing and commissioning of HT UG cables, 11000 volts grade, 3 core 95 Sqmm (Earthed), XLPE insulated and PVC shealthed, steel wire armoured, with multi stranded aluminium conductor, heavy duty conforming to IS - 7098 part-II 1985, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed.
Supply Lay,testing & commission UG cable XLPE insulated armoured heavy duty electric cable 1100 volt grade with stranded aluminium conductor cross sectional area 3.5/4 core AC supply of following size:-
a) Cable under ground LT 95 Sqmm 3.5 core
b) Cable under ground LT 70 Sqmm 3.5 core
c) Cable under ground LT 50 Sqmm 3.5 core
M & L in replacement for GI pipe light grade laid in trenches for cable protection of size 50mm dia. complete all as specified and directed
M & L in replacement for GI pipe light grade laid in trenches for cable protection of size 80 mm dia. complete all as specified and directed
S & F in replacement of Lugs of 35 sqmm to 50 sqmm complete all as specified and directed
S & F in replacement of Lugs of 70 sqmm to 185 sqmm complete all as specified and directed
S & F in replacement Danger notice plate of 1.6 cm thick mild steel vitreious enamelled white, with letters, figures and conventional and boxes in signal red colour and fixed with MS clamps, bolts & nuts of approved size for HT 25 x 20 cm size complete all as specified and directed
S & F in replacement Danger notice plate of 1.6 cm thick mild steel vitreious enamelled white, with letters, figures and conventional and boxes in signal red colour and fixed with MS clamps, bolts & nuts of approved size for LT 20 x 15 cm size complete all as specified and directed
M & L repairs to LT/HT pillar box by opening door hinges and taking rusted portion of door incl removing bends / dents and refixing the door with new hinges, handles, making good surfaces bolting etc and painting of LT pannels by duly cleaning the surface from dust and grease and applying one coat of synthetic enamel paint by using spray gun colour as directed by the Eng-in-Charge and lettering the LT pannels with black/white paint using stencils or making lettering by using stickering with minium size of letter to be of 5 Cm complete all as specified and directed
M & L for cement painting of with prepared white (snow sem ) for transformer /LT /HT poles plitnth area/ Copings of any size complete all as specified and directed [Note:- including scrapping & cleaning with wire brush )
Taking down the burnt MCCBs from the LT panels/feeder pillar boxes, supply & fix , test & commissioning of MCCB 250 Amps/25KA, 4 Pole complete all as specified and directed
Taking down the burnt MCCBs from the LT panels/feeder pillar boxes, supply & fix , test & commissioning of MCCB 160 Amps/16KA, 4 Pole complete all as specified and directed
Taking down the burnt MCCBs from the LT panels/feeder pillar boxes, supply & fix , test & commissioning of MCCB 125 Amps/16KA, 4 Pole complete all as specified and directed
Taking down the burnt MCCBs from the LT panels/feeder pillar boxes, supply & fix , test & commissioning of MCCB 100 Amps/16KA, 4 Pole complete all as specified and directed
Taking down the burnt MCCBs from the LT panels/feeder pillar boxes, supply & fix , test & commissioning of MCCB 63 Amps/16KA, 4 Pole complete all as specified and directed
Taking down unserviceable indication lamp and supply, fix and testing indication lamp (LED type) with showing red, yellow and green in colour of 22.5mm dia monitor on HT/LT panel board suitable for 240V AC supply complete all as specified and directed
S & F Contactor in replacement, 4 pole, 415V, 40A cap, MCX , 2 NO+2 NC utilsed for heavy duty by taking down the old perished / deteriorated contactor against repairs complete all as specified and directed
Servicing and repairing/ carryingout maintenance of 11 KV/440V transformer including the following works for 500 KVA capacity as follows : - (a) Disconnecting the transformer from platform, electrical connection from HT & LT side, earthing side, lifting with the help of crane all as specified. (b) Dismantling the transformer, drain out trransformer oil, lift the cover, coil assembly & keep up the assembly in oven upto the preparation. Scratching the body with wire brush for any carbon deposite and oily substance from the transformer. (c) Cleaning the core iron sheet laminations assembly by oil complete, removing carbon sediments, dust in the coil and core gently without making any damage to coil and core. (d) Re-assembling all dismantled parts including provision of new gasket, nut, bolts, refilling with transformer oil. (e) Electrical connection to HT, LT and earthing side, testing and commissioning for satisfactory performance. Note: (i) Transformer oil filteration and topup of new oil will be measured and paid seperately. (ii) All petty parts including nut, bolts, gasket and minor weldings /patch work are deemed to be included in the rate quoted. (iii) The rate for lifting by crane, are deemed to be included in the unit rate quoted. (iv) All major parts if any replaced and rewinding of HT & LT coil are not included in the unit rate mentioned . Same will be priced and measured seperately under relevant items of Sch.
All as per item No 27.00 above but for 400 KVA complete all as specified and directed
All as per item No 27.00 above but for 250 KVA complete all as specified and directed
All as per item No 27.00 above but for 200 KVA complete all as specified and directed
All as per item No 27.00 above but up to 100 KVA complete all as specified and directed
All as per item No 27.00 above but up to 63 KVA complete all as specified and directed
Attending electrical breakdown in the distribution transformer by repairing the same by arresting the sparking on HT & LT side by securing the joints, replacing the HT fuses, nuts, bolts in the spot for restoration of supply for upto 500 KVA transformer complete all as specified and directed
Supply only HT bushing insulator, Brass metal studs nut & washers suitable for HT bush side of transformer up to 500 KVA complete all as specified and directed
Supply only LT bushing insulator, Brass metal studs nut & washers suitable for LT 415 Volt bush side of transformer up to 500 KVA capacity of transformer complete all as specified and directed
Supply and fill new EHV grade insulating transformer oil complete with minimum BDV 60 KV complete all as specified and directed.
Filteration of existing transformer oil with high pressure vaccum filteration plant to improve dielectric strength of insulating oil including testing for BDV of the filteration oil not to be less than BDV 60KV complete all as specified and directed. Note :- (a) Rates includes the requirement of tools/plants at site where transformer oil to be filtered. (b) Transformer shall be kept in OFF position during filteration. (c) Temperature of oil should be kept below 75 ' C' during filteration.
Supply and fill in repairs existing breather silca jel of superior quality for transformer breather complete all as specified and directed.
S & F in repairs breather unit of transperant PVC material including its replacement for transformer of capacity up to 500 KVA complete all as specified and directed.
M & L Disc type porcelain vitreous, brown or white insulator to suit 11 KV HT working Pressure of size 145 mm height, 255 mm dia , including. one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete including dismantling existing old insulator from position complete all as specified and directed.
M & L Pin type porcelain vitreous,brown of white insulator to suit 11 KV HT of working pressure of size 150mm height, 150mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete including dismantling existing old insulator from position complete all as specified and directed.
M & L Post insulator suitable for 11 KV HT working pressure including all connected accessories including dismantling existing old insulator from position complete all as specified and directed.
Replacement of ACSR type jumpers (appx 1.5 RM in length) of suitable dia incl aluminium lugs of suitable size for HT structures and yards including PVC insulation pipe and cleaning of carbon deposited on joints,applying jelly to each contact points and GOD male & female contacts and dismantling old jumpers complete all as specified and directed.
Taking down 11 KV air break gang operated switches vertical / horizontal mounted including insulators and operating mechanism for insulators and operating mechanism for repair/replacement of broken/worn out components and insulators etc. complete all as specified and directed.
M & L Outdoor type Gang operated Air break switch triple pole, mechanically operated, mounted on insulator and steel frame,with operting mechanism worked from ground level with GI pipe medium grade, for current rating upto 200 Amps suitable for vertical mounting fixed type complte with 15 Nos HT insulators suitable for HT 11 KV complete all as specified and directed.
M & L Lightning Arrestor (LA) zinc oxide type complete with all fittings transmission class, discharge capacity 60 KA, suitable for 11 KV and removing old existing unserviceable one complete all as specified and directed.
Supply only in repairs HT Fuse element of HT 11KV, 10 Amp to 30 Amp rating complete all as specified and directed.
Dismantling of MS cross arms bracing support clamps nuts bolts and washers etc and M/L for cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles all as specified and directed incl painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces complete all as specified and directed.
S & F in replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 Sqmm to 120 Sqmm complete all as specified and directed.
S & F in replacement Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and directed.
M & L MS frame work alongwith galvalume sheet 0.5mm thick of size 3.0 x 2.0 x 3.5 Mtr for Metering cubicle panel and outdoor type HT panel for E/M installation and similar work including cutting tops to shape, drilling holes, etc embedded in concrete / masonary complete duly painted with two coats of primier and one coat on synthetic enamel paint, drilling, bolting or reveting confirming to Fe.290 Gde-165 including fixing it on required surface with necessary cement and welding work complete all as specified and directed.
M & L Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25m deep below the ground level with top to edge of the plate n. less than 1.5m below ground level connected to galvanized earth wire 4 mm dia by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 15mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion all as specified.
M & L Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4mm as earthing lead by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe of suitable dia and required length for protection of GI strip and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion all as specified.
S & F in repairs AAC for binding purpose of not less than 0.9mm dia for tightening the conductors on poles complete all as specified and directed.
M & L graded coarse aggregate (broken stone or boulders) of size 40 mm in substation yard for laying complete all as specified and directed.
M & L Servicing /testing and calibration of line breaker/control panel including outdoor CT, PT and relays in control panel of indoor VCB of capacity 630/400A Amps and rating 11 KV complete as details mentioned as under:- (a) Details of servicing of breaker :- (i) Checking of Closing/Tripping coil assembly (ii) Adjustment of mechanism if required. (iii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iv) Checking the contact for wear. Replace if the contact piece has worn out. (v) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (vi) Check for rust and wear. (vii) Checking of spring charge mechanism (viii) Visual check for rust and deformation. (ix) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (x) Check for loosened connections, rust, damaged lead wires. (xi) Checking of control circuit & tighten the connections if any. (xii) Check close & trip coil. (xiii) Replacement of Dashpot/shock absorbers . (xiv) Replacement of carbon brush of spring charging motor (xv) Cleaning of porcelain bushing (xvi) Checking of limit switch
SLB Enterprises (BID ID -3085214)
Shree Ayyappa Engineering (BID ID -3087286)
BRO TECH ELECTRICAL & ENGINEERING SOLUTION (BID ID -3084185)
Shine Enterprises (BID ID -3083732)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .