Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹17.6 L
EMD Value
₹35,200
Closing Date
2 Dec 2026, 3:30 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (WMS)
Above/Below/Par
CONS
23 conditions · 10 needing a document upload
The tenderer should submit the consent in a mandate form of Enclosure-1 for receipt of payment through NEFT
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Certificates which may be an attested Certificate from the client, Audited Balance Sheet duly certified by the Chartered Accountant etc regarding contractual payments received in the past
Tenderer shall indicate their GSTIN No. & PAN No. with proper document proof.
If the tenderer wish to submit Bank guarantee for bid security (EMD), the Tenderer shall download the Tender Document Annexure -VI A for bid security in the form of bank guarantee and upload the Annexure -VI A duly filling the necessary details. The original Bank Guarantee should be delivered in person to Office of the PCEE, II floor, Shell Administrative building, ICF, Chennai - 600 038 before closing date for submission of bids (i.e. excluding the last date of submission of bids)
The Tenderer shall have valid required level Electrical License. Attested copy of the Electrical License shall be submitted along with the offer.
The successful tenderer shall prepare and submit the Scheme for wiring along with layout of arrangement of Electrical switchgear drawings according to the site and obtain approval from the competent authority or their authorized representative prior to the commencement of work.
After completion of all wiring and installation, the successful tenderer shall submit 3 sets of General arrangement and Schematic drawings along with the electrical wiring documentation.
The rate quoted shall be net inclusive of all taxes (GST) and duties.
The Contractor has to engage only Police verified Pvt. labour /Pvt. Employee. If any new person (other than already verified) to be engaged by the contractor, he has to submit proof of Police verification application for issuing a "Temporary permission" like present permit system. However, Contractor has to arrange PV report within permissible period of one month.
The tenderer shall download the Tender Document Annexure -I and upload the Annexure -I duly filling the necessary details.
Electrical power supply arrangements for provision of Air conditioning at RPF barracks
2026245212384~ICF
2026245212384
Open
Works - General
6 Months
Chennai, Tamil Nadu
₹0
₹35,200
10 Nov 2026
10 Nov 2026
18 Nov 2026
35 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 17,61,286 | ||
| — | 300.00 | — | — | ||
| Supply of 70 Sq.mm. 4 core, XLPE LT, AL, Armored, UG Cable as per ICF Specification. | — | — | — | 1,58,100 | |
| — | 100.00 | — | — | ||
| Supply of 120 Sq.mm. 4 core, XLPE LT, AL, Armored, UG Cable as per ICF Specification. | — | — | — | 1,09,000 | |
| — | 100.00 | — | — | ||
| Supply & laying of 4 core, 10 sq.mm armored copper cable as per ICF Specification. | — | — | — | 1,00,000 | |
| — | 300.00 | — | — | ||
| Laying of LT cable up to 300 Sq.mm. duly excavating and refilling the trench with excavated earth as per ICF Specification. | — | — | — | 47,400 | |
| — | 100.00 | — | — | ||
| Laying of LT XLPE Aluminum and Copper cables up to 300sq.mm, in cable trays/trenches as per ICF Specification. | — | — | — | 3,500 | |
| — | 20.00 | — | — | ||
| Supply & End termination of UG AI cable 3.5/4 Core, 70/120/185 Sq.mm. with all required items like proper glands and crimping sockets, hardware, crimping paste, etc., as per ICF Specification. | — | — | — | 11,640 | |
| — | 10.00 | — | — | ||
| Supply & erection of end termination of copper cable 10/16 sq.mm with all required items like proper glands and crimping sockets, hardware, crimping paste etc., as per ICF specification. | — | — | — | 650 | |
| — | 900.00 | Each Span | — | ||
| Supply & running of 2 Runs of 4.0 Sq.mm and 1 Run of 1.5 sq.mm PVC FRLS copper cable (Red, Black, Green) in 1" PVC conduit/ Casing capping and accessories duly Fixing the conduit in the wall using Hardware. Contractor scope of supply includes PVC conduit, PVC cable, PVC accessories, hardware etc., as per ICF Specification. (One span Shall consist of one meter length of 2 runs of single core 4.0 Sq.mm & 1 run of single core 1.5 Sq.mm FRLS copper cable, PVC pipe., PVC accessories and hardware etc.,) | — | — | — | 2,01,600 | |
| — | 10.00 | — | — | ||
| Supply and Erection of 3 phase 6-way TPN MCB type Double Door distribution board with 63A, 4P MCB - 1 no, 63A 30MA RCCB as incomer - 1no, 20A, SP MCB - 18 nos as outgoing duly removing the old DB as per ICF Specification. | — | — | — | 3,87,040 | |
| — | 5.00 | — | — | ||
| Supply and fixing of 400 x 300 mmx150mm Sintex box with 63A 4 pole MCB, and 63A 4 pole connector and all other required materials duly removing existing connector box as per ICF Specification. | — | — | — | 21,560 | |
| — | 30.00 | — | — | ||
| Supply & Erection of 3 module box with front plate suitable of 20A SP MCB - 1 no, 16A socket-1 no (for AC) as per ICF Specification. | — | — | — | 22,800 | |
| — | 1.00 | — | — | ||
| Supply, Fabrication, Installation, Testing and Commissioning of DB consisting of 250A, 4P, MCCB as Incomer-1 No, 100A, 3P MCCB- 5 Nos, as Outgoing and MFM in incomer, ON/OFF indications as per ICF Specification. | — | — | — | 3,71,700 | |
| — | 1.00 | — | — | ||
| Supply, Erection, Testing & commissioning of Earthing Electrode to Drg No. ICF/EL/1289 inclusive of supply of all reqd. materials like 50 mm dia pipe, copper strip of size 25X3 mm, all reqd. hardware and all other materials etc., as per ICF Specification. | — | — | — | 8,240 | |
| — | 5.00 | — | — | ||
| Supply and laying of 8 SWG copper wire as per ICF specification. | — | — | — | 3,210 | |
| — | 2.00 | — | — | ||
| Breaking & redoing of concrete portion using contractors' own materials as per ICF specification. | — | — | — | 7,928 | |
| — | 1.00 | — | — | ||
| Supply, erection, testing & commissioning of Floor Mounting type 7-way MDB Board made out of 2mm CRCA sheet steel enclosure consisting of copper busbar cable chamber, earthing and powder coated painting with the following incoming and outgoing as below:Incoming: 400 Amps HRC Fuse &Fuse base holder - 03 Nos. Outgoing: -250 Amps HRC Fuse & Fuse base holder - 04 Nos with duly removal of old MDB as per ICF Specification. | — | — | — | 2,77,418 | |
| — | 1.00 | — | — | ||
| Foundation of suitable Size for 7 Way MDB, complete with cement, Morang, concrete ratio 1:2:4 & Bricks above from ground level as per ICF Specification. | — | — | — | 29,500 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
LISTOFWORKSONHAND.pdf
ATTACHMENT
LISTOFMachinery.pdf
ATTACHMENT
NEFTForm.pdf
ATTACHMENT
LISTOFCONTRACT.pdf
ATTACHMENT
LISTOFPERSONNEL_1.pdf
ATTACHMENT
TenderFormAnnexure-I.pdf
ATTACHMENT
IRGCC_April-2022.pdf
ATTACHMENT
annex6B.pdf
ATTACHMENT
IRGCCACSCombined_3.pdf
ATTACHMENT
ACS12.pdf
ATTACHMENT
947Tenderdocument.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .