Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC 11 CIVIL LINES ROORKEE 247667 DISTT HARDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹35.9 L+₹14,705.89 (0.41%)Rejected-AOC | L2 | Rejected-AOC Rejected being not L1 |
Tender Value
₹35.9 L
EMD Value
₹71,700
Closing Date
26 Apr 2022, 6:00 pmClosed
GE (MES) ROORKEE
Garrison Engineer Military Engineer Services Roorkee
SPL REP TO 2XLPG GODOWN IN 297 ASC SUP SPL REP TO GI ROOF SHEET IN T173 T174 AND T175 (TORES T176 OFFICE OF 135 INF BDE SIG COY SPL REP TO SOUND PROOFING OF AUDIOMETRY ROOM IN ENT DEPT BLDG NO. T2 AT MH AND PROVN OF 08 PARKING SHED IN FRONT OF VIJETA
2022_MES_511676_2
8392/145/E8
Open Tender
Civil Works
Item Rate
180 days
Roorkee
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (MES) Roorkee
₹71,700
Yes
1 Jun 2022
6 Apr 2022
28 Apr 2022
6 Apr 2022
26 Apr 2022
13 Apr 2022
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles etc complete all as specified and directed
M&L for brick work with old size sub class 'B' bricks in cement mortar (1:6), straight or curved on plan exc 6m mean radious complete all as specified and directed.
Taking down cement or cement lime plaster on brick or stone walls etc including racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete work surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete work surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof covering and wall cladding etc complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as specified and directed by Engineer-in-Charge
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as specified and directed by Engineer-in-Charge
M&L for 75mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection, path/hardstanding etc, laid in bays/panels n.exc 2.50 Sqm each including construction joints at suitable intervals and each corner and filled with bituminous mastic filling (1part bitumen & 3 parts sand) and finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for cleaning concrete surfaces and supply & laying 25 mm thick spark proof mastick flooring confirming to IS: 8374 and other relevant specifications after applying one coat of priming bitumen primer @ 0.30 Kg/Sqm using blown bitumen on concrete surface complete all as specified and as directed.
S&F MS framed work such as grills, gratings with ends of bars shouldered and or riveted or forged into spikes, framed guard bar, barred iron door, ladders, hold fast, framed balusters, walk ways, railings, frame work of water tank and similar work conforming to Fe 290 Gde E165 complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) etc complete all as specified and directed
M&L for hard core of broken stone or boulders of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base to floor complete all as specified and directed.
M&L for complete removal of existing decorative treatment on walls, cornices etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of cement base paint complete all as specified and directed.
Dismantling timber scantlings 40 Sqcm and over in section, fixed in framed work in any position complete as specified and directed by Engr-in-Charge
S&F rolled mild steel work in joist, channel, angle or tee sections, fixed independently without connecting plates etc, quality conforming to Fe 410 W (Gde E-250 quality A) complete as specified and directed by Engineer-in-Charge
Dismantling wall and ceiling board (fiber, pulp, insulation etc) or insulation boards / slabs any thickness including cover fillets complete all as specified and directed.
S&F 10mm thick Gypsum Board (Gypsum anhydrous) of sizz 605x605 mm, fixed to flat ceiling surfaces with Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre, intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm, suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.20 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and hangers 6 mm dia GI wire (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of GI flat iron 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of white wash complete all as specified and directed.
M&L for complete removal of existing decorative treatment on walls, cornices etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying 1.5mm thick wall care putty of approved make and two coats of oil bound distemper (White or tinted) complete all as specified and directed.
M&L for new plastered surface on walls and applying two coats cement based paint over one coat of alkali resistant priming paint complete all as specified and directed.
Taking down chowkhat or frame with shutter without taking off shutters from the frame, size of shutter exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed.
Dismantling of timber scantling in fillets, rails, posts, rafters, purlins, etc under 40 Sqcm in section fixed in framed work complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Disconnecting of indoor unit of split AC and refixing in the same position after completion of wall paneling complete all as specified and directed.
S&F IInd class hard wood (Sal) plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered but together with glue, pinned at joints including preparation of wooden surfaces and applying two coats of french polish complete all as specified and directed.
S&F mild steel work as in holdfasts, wind ties, plane angle cleats for securing purlins to wooden trusses or rafters etc complete all as specified and directed.
Cutting holes in brick walls exc half brick but n.exc one brick thick wall built in cement mortar or cement lime mortar and stone walls built in lime mortar or for inserting holdfasts and making good dismantled portion in cement concrete (1:2:4) type B1 or in cement mortar (1:3) as required complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B0 (using 12.5 mm graded graded stone aggregate) as in cills, copings, bed block and the like complete all as specified and directed.
S&F 100 mm thick sound proof door shutter consisting of wooden frame filled with 4 cm thick layer of glass wool medium density, covered with 4 cm thick thermocol sheet, covering with 12mm thick plywood with two coats of synthetic enemal paint including preparing surfaces complete all as specified and directed.
S&F floor carpet 6mm thick including pasting of prepared floor surfaces with adhesive of approved quality complete all as specified and directed.
M&L for joint free glazed ceramic coloured tiles of size 450x300x7mm thick in vertical surface over and including 10mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for Sound proofing of wall by providing GI Z Channel fittings of size 40mmx50mm, fixed to wall and top, fixing two layers of Rockwool sheet 96 density on walls, covering with 2 layer of industrial tissue paper of 50GSM, fixing GI perforated sheet 0.4mm thick, filling the gaps with putty and finally fixing 15mm thick Acoustic tiles, finishing the surfaces to desired level including distempering etc as per user's satisfaction complete all as specified and directed.
M&L for tiled false ceiling of gypsum perforated tiles of 4mm thickness (as per IS:14862) of size 595x595mm in true horizontal level, suspended on inner locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grms, both side inclusive and black painted groove on all T webs) consisting of main “T” runner with suitably spaced joints to get required length and 15x32mm made from 0.3mm thick sheet, 1200mm long spaced between main “T” at 600mm C/C to form a grid of 1200x600mm and secondly cross “T” of length 600mm and size 15x32mm made of 0.30mm thick sheet to be interlocked at middle of 1200x600mm panel to form grids of 600x600mm and wall angle 15x20x0.36mm and laying false ceiling tiles in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanized butterfly level clips, spaced at 1200mm c/c along main “T”, bottom exposed width of 15mm of all “T” sections shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5 mm width, including packing of 75mm thick glass wool over hidden side of ceiling for sound proofing with necessary fixing arrangements complete at any height as per directions of Engineer-in-Charge.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in squares n.exc 0.50 Sqm each pane with oil putty and filling the gap with silicon gel complete all as specified and directed by Engineer-in-Charge.
M&L for chemically treated acoustic double glass unit of size 800x800mm, 8mm thick toughened clear glass on both sides with 12mm air gap filled with argon and sealed with aluminium or black silicon at sides complete all as specified and as directed by Engineer-in-Charge.
M&L for working counter consisting of wooden platform and supports as per user's directions, finished with two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Removing excavated soil n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Excavation in post holes (or similar holes) in soft / loose soil, each n.exc 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc. 25 cm, watering and removing surplus soil to a distance n.exc.50 m and making good the surfaces complete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D2 using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M&L mild steel work in tubular trusses/purline/ column/nut bolts/base plate including special shaped washer etc using ERW or induction butt welded tubes conforming to IS: 1161- 1979 grade St-240 complete all as specified and directed.
M&L for 100mm thick plain cement concrete (1:2:4) type B- 2 (using 40mm graded stone aggregate) as in flooring, finished even and smooth without using extra cement complete all as specified and directed.
Taking down old unserviceable copper/aluminium point wiring (light, fan, socket or power ponts) including fittings and fixtures such as switches, sockets, ceiling rose, pendant, fan regulators etc and M&L for new point wiring with PVC insulated PVC unsheathed electric (FRLS) cable of size 1.5 Sqmm nominal cross sectional area, 1100 Volt grade, single core having multi stranded copper conductor, drawn throgh and including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting chases in wall and making good disturbed surfaces in cement mortar (1:3) to match the existing surfaces (PVC conduit shall be used on ceiling surface for fan point only) with 1.5 Sqmm green PVC insulated unsheathed electric (FRLS) cable having multistranded copper conductor as earth wire connected to earth dolly by providing lugs including sunk pressed steel terminal boxes made of 1.6 mm thick GI sheet duly painted with two coats of black bituminous paint over a coat of red oxide primer on inner and outer surfaces with and including 2.8mm thick plastic laminated bakelite sheet cover of hylam board including cutting holes for switches, sockets, regulators etc as per site requirement and fixing with machine made brass screws, washers etc complete all as specified for the following:-
One light point controlled by one, one way 5/6 Amps switch
One fan point controlled by one, one way 5/6 Amps switch
One socket outlet point for 3/5 pin 5 Amps socket on the same board with other switches.
One socket outlet point for 3/5 pin 5 Amps socket on independent board.
All as per Srl item No. 47.00 here-in-before but one power point with 1.5 Sqmm nominal cross sectional area, 1100 Volt grade, single core having multi stranded copper conductor for 3/5 pin 15 Amps socket including 2.5 Sqmm green PVC insulated unsheathed electric (FRLS) cable having multistranded copper conductor as earth wire complete all as specified and directed.
S&F switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified.
S&F switch piano flush type polycarbonate single pole one way 15 Amps complete all as specified.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5/6 Amps flush type complete all as specified.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type complete all as specified.
S&F electronic fan regulator 230 Volts, stepped type (5 steps) socket type, hum free 100/300 Watt complete all as specified and directed.
S&F ceiling rose in polycarbonate with 3 brass terminals, 6 Amps, 230 Volts, AC (ISI marked), fixed on & including 3 mm thick 75mm dia sunmica hylum plastic laminated round sheet complete all as specified and directed.
S&F in replacement, LED tube light fitting 1x20 Watt T 8 LED batten integrated type with bipin holders connector block complete with all accessories internally prewired including connecting up with three core single wire of suitable size and 20 watt retrofit LED tube rod T 8 polycarbonate complete all as specified and directed. Make- Havells Cat Part No. REGAL BATTEN T-UP to 1x22W SS BSWH (batten) & PHOTON ULTRA E-2.01213T8SSTL20W LED 865 SPC (T-8 Rod) or Bajaj Cat Part No. 112181BLRB-DB 118 (batten) & 112481BLRB21WCWC (T-8 Rod) or Crompton Cat Part No. DIJB12LT8-20 MODEL-ECO
S&F in replacement, recess mounting type light fitting 2' x 2' of capacity 35/36 Watts powder coated white CRCA full glow suitable for 600 x600 mm POP false ceiling including making electrical connection from ceiling rose to light fitting with and including three core single wire of suitable size complete all as specified and directed.
Taking down old unserviceable sub main wiring of any description and S&F new sub main wiring with two runs of 4.0 Sqmm 1100 Volt grade single core PVC insulated and unsheathed (FRLS) LT cable having multi stranded copper conductor, drawn through and including PVC non metallic conduit of 20mm / appropriate dia with all accessories and one run of 4.0 Sqmm 1100 Volt grade single core PVC insulated and unsheathed (FRLS) LT cable having multi stranded copper conductor complete all as specified and directed by Engineer-in-Charge. Note:- (i) Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. (ii) Cable required for connection to DBs and MCBs shall be deemed included in quoted rates. (iii) Earth wire shall run inside the conduit pipe.
All as per srl item No. 57.00 here in before but submain wiring with two runs of 6.00 Sqmm FRLS copper conductor and one run of 6.0 Sqmm FRLS earth continuity conductor complete all as specified.
S&F in replacement, Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way conforming to IS : 13032-1991DB, 415 Volts IP 43 (double door) with 200 Amps rated copper bus bar neutral bar, earth bar, flush to wall complete all as specified and directed.
S&F in replacement, MCB single pole, 6 to 32 Amps 240 Volt 'C' curve 10 kA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area including copper lugs of suitable size complete all as specified and directed.
S&F in replacement, MCB double pole, 40 Amps 240 Volt 'C' curve 10 kA, IP 20, 50 Hz, transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area including copper lugs of suitable size complete all as specified and directed.
S&F in replacement, MCB SPN, 63 Amps 240 Volt 'C' curve 10 kA, IP 20, 50 Hz, transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area including copper lugs of suitable size complete all as specified and directed.
S&F in replacement, Single pole and neutral enclouser with a two pin and earth plug and socket with and including one single pole MCB of rating 20 Amps 240 volt grade complete all as specified and directed.
M/s Inderlal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .