Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC TEHSIL SARKAGHAT P O RAKHOH VILL GADHANI SARKAGHAT MANDI HP 175024 | MANDI | HIMACHAL PRADESH | 175024 | ₹34.5 L Quoted ₹35.6 L | L1 | Accepted-AOC ACEEPTED |
| 2 | L2₹36.6 L+₹1.1 L (3.04%)Rejected-Finance | ₹36.6 L+₹1.1 L (3.04%) | L2 | Rejected-Finance REJECTED BEING NOT LOWEST TENDER |
| 3 | L3₹37.3 L+₹1.7 L (4.82%)Rejected-Finance | ₹37.3 L+₹1.7 L (4.82%) | L3 | Rejected-Finance REJECTED BEING NOT LOWEST TENDER |
| 4 | L4₹38.0 L+₹2.5 L (6.99%)Rejected-Finance | ₹38.0 L+₹2.5 L (6.99%) | L4 | Rejected-Finance REJECTED BEING NOT LOWEST TENDER |
| 5 | L5₹38.8 L+₹3.2 L (9.02%)Rejected-Finance PLOT NO 86 SHIVAM PARK 2 AIR PORT ROAD BEHIND SANATAN MANDIR BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹38.8 L+₹3.2 L (9.02%) | L5 | Rejected-Finance REJECTED BEING NOT LOWEST TENDER |
| Sl No | Description | Qty | Unit | Pal Engineering Services L4 | MAHADEV ELECTRICALS L2 | JYOTI TRADERS L5 | PANTECH INSTRUMENTS AND SERVICES L3 | VATANUCOOL ENGINEERS L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete, all as specified and directed by Engr-in-Charge.
Note: (Applicable for Sch ‘A’ Item No.1). (i) Split type AC's shall be taken from department on "as and where installed" basis.
(ii) Split type AC's are to be maintained for heating as well cooling , where this provision is in the machine. (iii) The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, cooling coil & blower motor) under relevant items shall be included in item No.1).
(iv) The contractor shall ensure and asses at the site any initial maintenance required, to make the all Split type AC's in proper working condition, at the time of taking over and he shall be laible to make all listed handed over units functional. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. | 250 | Each Job | 400 ₹1,00,000 Lowest | 500 ₹1,25,000 | 2,500 ₹6,25,000 | 600 ₹1,50,000 | 1,700 ₹4,25,000 |
| 2.00 | M&L for Repair to existing rotory type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) | 3 | Each | 9,595 ₹28,785 | 10,000 ₹30,000 | 9,000 ₹27,000 | 15,500 ₹46,500 | 6,500 ₹19,500 Lowest |
| 3.00 | Supply only new Rotory type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5 TR/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) | 5 | Each | 12,720 ₹63,600 | 10,000 ₹50,000 Lowest | 12,000 ₹60,000 | 12,500 ₹62,500 | 11,000 ₹55,000 |
| 4.00 | Supply only new Rotory invertor type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5 TR/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) | 10 | Each | 18,600 ₹1,86,000 | 10,000 ₹1,00,000 Lowest | 16,000 ₹1,60,000 | 12,000 ₹1,20,000 | 18,000 ₹1,80,000 |
| 5.00 | Supply only new condensing coil unit for Split type AC of any type/ any capacity complete, all as specified and directed by Engr-in-charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) | 10 | Each | 8,888 ₹88,880 | 2,450 ₹24,500 Lowest | 12,010 ₹1,20,100 | 2,500 ₹25,000 | 7,500 ₹75,000 |
| 6.00 | Supply only blower motor including fan blade, capacitor complete suitable for split type AC 1.5 ton/2.0 ton capacity 1/8 HP, 220 Volts, single phase complete,all as specified and directed by Engr-in-Charge. | 2 | Each | 4,900 ₹9,800 | 1,500 ₹3,000 Lowest | 2,500 ₹5,000 | 1,600 ₹3,200 | 2,800 ₹5,600 |
| 7.00 | Labour only for charging refrigerant gas in the system of window/Split type AC of 1.5/2.0 ton capacity all as directed by the Engr-in-charge. (Note : The refrigerant gas measured and paid separately under relevant items as applicable as ‘supply only’). | 50 | Each Job | 50 ₹2,500 Lowest | 110 ₹5,500 | 225 ₹11,250 | 200 ₹10,000 | 300 ₹15,000 |
| 8.00 | M&L for replacement of unserviceable running capacitor 36/45/50 MFD 230 V for window/Split type AC 1.5 Ton/2.0 Ton capacity/water cooler complete, all as specified and directed by Engr-in-charge.. (Make : Universal/Sarda ) | 2 | Each | 150 ₹300 | 130 ₹260 Lowest | 222 ₹444 | 150 ₹300 | 175 ₹350 |
| 9.00 | M&L for replacement of unserviceable capillary tube and stainer for window/Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge. | 10 | Each | 222 ₹2,220 | 650 ₹6,500 | 110 ₹1,100 | 800 ₹8,000 | 105 ₹1,050 Lowest |
| 10.00 | M&L for replacement of unserviceable PVC air filter for Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge. | 10 | Each | 222 ₹2,220 | 450 ₹4,500 | 120 ₹1,200 | 500 ₹5,000 | 109 ₹1,090 Lowest |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
27 Jul 2026, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REPAIR/ REPLACEMENT OF AC, REFRIGERATOR, WATER COOLER GEYSERS INTERNAL ELECTRIC SUPPLY OF BUILDING SUBMAIN, DB, CEILING, EXHAUST, WALL MOUNTING, PEDESTAL FAN AND ITS CONNECTED WORKS IN TECH AND RESIDENTIAL AREA OF IRDE UNDER GE (I) RND DEHRADUN
2026_MES_775377_1
GE(I)RND/9595/E8/26-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dehradun
As per tender documents
7 documents required · 7 mandatory
₹500
GE I RND DEHRADUN
₹76,000
Yes
12 Sept 2026
30 Jun 2026
29 Jul 2026
30 Jun 2026
27 Jul 2026
13 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete, all as specified and directed by Engr-in-Charge.
Note: (Applicable for Sch ‘A’ Item No.1). (i) Split type AC's shall be taken from department on "as and where installed" basis.
(ii) Split type AC's are to be maintained for heating as well cooling , where this provision is in the machine. (iii) The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, cooling coil & blower motor) under relevant items shall be included in item No.1).
(iv) The contractor shall ensure and asses at the site any initial maintenance required, to make the all Split type AC's in proper working condition, at the time of taking over and he shall be laible to make all listed handed over units functional. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. | 250 | Each Job | - | - |
| 2 | M&L for Repair to existing rotory type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) | 3 | Each | - | - |
| 3 | Supply only new Rotory type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5 TR/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) | 5 | Each | - | - |
| 4 | Supply only new Rotory invertor type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5 TR/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) | 10 | Each | - | - |
| 5 | Supply only new condensing coil unit for Split type AC of any type/ any capacity complete, all as specified and directed by Engr-in-charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH ) | 10 | Each | - | - |
| 6 | Supply only blower motor including fan blade, capacitor complete suitable for split type AC 1.5 ton/2.0 ton capacity 1/8 HP, 220 Volts, single phase complete,all as specified and directed by Engr-in-Charge. | 2 | Each | - | - |
| 7 | Labour only for charging refrigerant gas in the system of window/Split type AC of 1.5/2.0 ton capacity all as directed by the Engr-in-charge. (Note : The refrigerant gas measured and paid separately under relevant items as applicable as ‘supply only’). | 50 | Each Job | - | - |
| 8 | M&L for replacement of unserviceable running capacitor 36/45/50 MFD 230 V for window/Split type AC 1.5 Ton/2.0 Ton capacity/water cooler complete, all as specified and directed by Engr-in-charge.. (Make : Universal/Sarda ) | 2 | Each | - | - |
| 9 | M&L for replacement of unserviceable capillary tube and stainer for window/Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge. | 10 | Each | - | - |
| 10 | M&L for replacement of unserviceable PVC air filter for Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge. | 10 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tenderpage.pdf
Tender Documents • 0.27 MB
SpecialconditionandPS.pdf
Tender Documents • 0.55 MB
GCSM.pdf
Tender Documents • 0.08 MB
BOQ_868246.xls
BOQ • 3.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .