Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.6 LAccepted-AOC | 1 | Accepted-AOC Work Awarded | |
| 2 | 2₹8.8 L+₹18,674.03 (2.17%)Rejected-Finance | 2 | Rejected-Finance Above estimate rate |
Tender Value
₹10.5 L
EMD Value
₹10,500
Closing Date
20 Oct 2023, 3:00 pmClosed
Executive Officer
Thottiam Town Panchayat
Construction of Karumathi Mandapam and Water Supply Ward No.1 Salem Main Road( Opp to Manikkam Theatre) in Thottiam Town Panchayat
2023_DTP_377026_1
319/2023-R1
Open Tender
Civil Works
Works
90 days
work
Please refer document
3 documents required · 3 mandatory
₹0
₹10,500
30 Oct 2023
7 Oct 2023
20 Oct 2023
7 Oct 2023
20 Oct 2023
7 Oct 2023
Amount
Earth work excavation in all classes of Soils and Sub soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering , bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the Departmental officerswith an initial lead of 10mts and initial lift of 2mts and clearing and levelling the site etc, complete complying with standard specification.
Supply delivery and filling of Stone dust in Layer of not more than 15cm thick including watering with all layers and consolidation complying with standard specification including cost and conveyance of sand at site and all labour charges and all other incidential charges etc., complete as per Standard Specification.
Cement Concrete of mix 1 : 4 : 8 (One Cement four sand eight aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification.
Supplying and Filling of U/S Gravel from approved quarry in Layer of not more than 15cm thick including watering with all layers and consolidation complying with standard specification including cost and conveyance of material to site and all labour charges and all other incidential charges etc., complete as per Standard Specification.
Supplying and errecting steel centering including necessary supports for plain surfaces for Reinforced Cement Concrete works such as Coloumn footing,Coloumn pedestals,plith beams, grade beams,staircase steps,etc which requires only nominal strutting using mild steel sheetsof size 90mm x60mm and 10Bg stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervels etc complete in all floors Complying with standard Specification without Strutting.
Supplying and errecting steel centering including necessary supports for plain surfaces for Reinforced Cement Concrete works such as Coloumn footing,Coloumn pedestals,plith beams, grade beams,staircase steps,etc which requires only nominal strutting using mild steel sheetsof size 90mm x60mm and 10Bg stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervels etc complete in all floors Complying with standard Specification without Strutting.
0.0 mt to3.30mt
Supplying and errecting centering for Sides and Soffits including necessary supports and strutting upto3.29mt height for plane surfaces as detailed below in all floors with all cross bracings using mild steel sheets of size 90mm x60mm and 10BG stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 90cm centre to centre and supported by casurina props of 10cm to 13cm dia supported at not more than 75cm centre to centre etc complete Complying with standard Specification without Strutting.( TNSS NO or NBC No 30(S) 86 86 A V, VI(S3)VII
0m to 1.50mt
0.00m to 3.30mt
Brickwork in cement mortor 1 : 5 (One Cement and five Sand) using best quality of country bricks of size 83/4x41/4x23/4 including all cost of materials and Labour Charges including Curing charges etc., Complete as per standard specification.
Upto G.L.
0.00 mt to 4.50mt
Supplying and Fabrication of Steel and placing in position MS / Ribbed tor steel grills for RCC works as per design given including cost of steel and GI binding wire in Floors etc., Complete complying with standard specification in force per Kilogram.
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. (No separate payment will be made by the Department for the excess usage of materials) -Footing, Plinth beam, Tie beam/Lintel, Ground Floor Roof beam, salbs, Sloped roof beam and slabs
Below Ground Level
0.00 mt to 4.50Mt
P.C.C. 1 : 8 : 16 (One Cement, Eight sand and Sixteen aggregates) using 20mm gauge hard Granite broken stone jelly including cost of curing, etc., complete as per standard specification and as directed by Engineer incharge.
Special Plastering in C.M. 1 : 3 ( One cement, three sand) to 10 mm thick including all cost and conveyance of all materials to site including cost of cement which will be purchared locally by the contractor and conveyance of the same to the actual work site and cost form work including watering curing and all leads of good potable water and all other.
Weathering Coarse with concrete broken brick jelly concrete on 20mm. Gauge in pure slaked shell lime (no sand to be used) over roof slab be proportion of brick jelly to being 32cft 12.5 cft. Well beaten with wooden beaters giving the required shape and thickness as directed by the Departmental Officers.
Finishing the top of roof with one course of machine pressed tiles 20 C.m x 20 C.m x 2 C.m size using cement mortor 1:3 mix mixed with 2% by weight of Crude Oil and pointing with Cement Mortor 1:3 mix Cost of all materials and labour charges 10m2.
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Plastering in C.M. 1 : 5 (one cement five sand)to 12 mm thick including all cost and conveyance of all materials to site including cost of cement which will be purchared locally by the contractor and conveyance of the same to the actual work site and cost form work including watering curing and all leads of good potable water and all other.
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris, putty, wherever required etc., complete complying with standard specification.
Placing and Fixing of Door, and Window with Grill including all cost of material and Labour including all incidental charges etc., complete complying with standard Specifications.
Painting the new iron works such as steel doors, Windows,Ventilators windows bars,balustrades etc, in all floor with two coats of best approved first quality and colour of synthetic enamel paint of approved quality, colour and brand (to be approved by executive engineer before use on works ) over one the existing red oxide priming coat in all floors excluding cost of priming coat etc, complete complying with Standard Specification. ( The Make, Quality and colour of paint should be got approved by the engineer in charge before use on works )
Supplying and Fixing in position best approved of BIS quality P.V.C Rain Water down fall pipe having a pressure of 4Kg / Sq.cm including cost of necessary PVC shoe,PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails etc, and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc, complete. The rate shall be inclusive of cast of removable cast iron grating. The PVc pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.00mt pipe length etc, Complete Complying with Standard Specifications. (Rain water Down wall Pipe)
Wiring with 2 x 1.5 Sq.mm (22/0.3) PVC insulated SC Unsheathed Cu. Conductor of 1100V grade in cuitable PVC rigid pipe concealed in wall and Ceiling with PVC accessoires in flush with wall with 3mm thick Hylum Sheet cover with TW Switch box and 5A F.T. Switch and making good of the Concealed portion with suitable colour for PVC CONCEALED LIGHT POINT/FAN POINT (for Electronics Regulator) (SD NO: 24)
Wiring with 2 x 1.5 Sq.mm (22/0.3) PVC insulated SC Unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and Ceiling with PVC accessoires in Flush with wall 150mm x 100mm x 113mm TW Switch box with 3mm thick Hylum sheet cover for 5A 3 pin non inter locking CS Plug with continuous earth wire connection of 14SWG TC wire and making good of the Concealed portion with suitable colour for CONCEALED PVC PLUG POINT (SD NO: 36)
Supplying and Run of 2 of 1 .50 sq.mm [ 22 / 0.30 ) PVC Unsheathed Core Cable of 1100 V grade in suitable PVC rigid pipe of wall and ceiling with continuous earth wire connection 14 SWG TC wire with painting suitable color [ SD 54 ]
Supply and fixing of 16Amps DP switch with metal glad of 500V with fuse and nuetral(side handle) on suitable TW box PWD earthing (SD.No.141)
Supply and Fixing of TNEB meter Board suitable for 32A Single Phase Service connection with 32A Fuse unit (500V) 32A neutral link and earth link (1" x 1/8" Copper Flat) on TW Plank of Size 375mm x 300mm x 19mm with Supporting TW Reepers of 1" thick an either side with Painting with Suitable bolt and nuts for fixing the TW Plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB Meter to Fuse Unit (SD No :125)
Geophysical Investigation Charges
Drilling of 150mm dia Borewell in Hard rock area including 180mm dia pilot bore and labour charges for insertaion of casing pipe in the drilled hole etc.,
Drilling of 150mm dia Borewell in Hard rock area including 180mm dia pilot bore and labour charges for insertaion of casing pipe in the drilled hole etc.,
Supply and Delivery of Single Phase Pumpset with motor as per isi 20lpm x 150 m head
Conrol Panel Board Consist of following voltmeter &ammeter suitable for above pumpset
32 mm UPVC Adopter
32 mm Clampset
32mm PVC Pipe
32mm UPVC Coloum Pipe for pumpset
32mm GI Union
32mm GI Elbow
32mm GI Pipe
2.5 sq. mm Sub Flat Cable
25mm Pvc rigid Pipes
25mm Conduit Bend
1000 Litter HDPE Tank
Construction of Masonry Pedestal for Kiosk with a size of 0.75x0.45X1.20 m including material cost etc.,
Complete Construction of Masonry Pedestal 0.60m Height from the ground level for erecting the HDPE Tank including cost of all materials and labour charges
Construction of Soak pit for Mini Power Pump scheme as per the standard specification etc.
Providing Overhead wiring plumbing of the borewell and E.B., Deposits and other related charges.
NAGAPPA FERTILIZER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .