Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC 411 D JEEWAN PURAM BISHT DHARA BITHORIYA NO 1 HALDWANI HALDWANI NAINITAL UTTARAKHAND 263139 | NAINITAL | UTTARAKHAND | 263139 | L1 | Accepted-AOC Overall accepted as L1 | |
| 2 | L2₹54.5 L+₹24.2 L (79.8%)Rejected-AOC | L2 | Rejected-AOC Overall disqualified as L2 | |
| 3 | Rejected-Technical POLICE LINE ROAD KUMOUR PITHORAGARH | - | Rejected-Technical The Bidder did not qualifies the TQR |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
16 Sept 2023, 5:00 pmClosed
Superintending Engineer
Office of SE, OandM Circle, PTCUL, Haldwani
Construction of 33KV Transfer Bus Coupler Bay arrangement at 220KV S/s, Haldwani under 220KV OandM Division, PTCUL, Haldwani
2023_PTC13_62081_1
SE(OamdM)/PTCUL/HLD/24/2023-24
Open Tender
Electrical Works
Item Rate
180 days
220KV S/s, Haldwani
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,360
EE, 220KV OandM Division, PTCUL, Haldwani
₹98,000
Office of SE, OandM Circle, PTCUL, Haldwani
11 Jul 2024
17 Aug 2023
18 Sept 2023
17 Aug 2023
16 Sept 2023
17 Aug 2023
1 Sept 2023
Amount
Part-A (Supply )
33KV Double Break Isolator, 3-Phase, 1250 Amps (Without Earth Switch) including terminal connectors suitable for ACSR Panther Conductor.
33KV Bus Post Insulators.
PVC copper control cable (Armoured) (2.5mm x 4 core).
Galvanized steel lattice type structure with hardware for Bus Post Insulator, Isolators including Nut & Bolts, Foundation Bolts etc. as per approved drawings.
C-Wedge Clamp (Moose to Panther).
C-Wedge Clamp (Panther to Panther).
C-Wedge Clamp (Dog to Panther).
Bolted type suspension fitting suitable for ACSR panther conductor.
Peforated cable tray.
M.S. Angle (65mm x 65mm x 6mm).
M.S. Flat (50mm x 50mm x6mm).
Description of Work / Item(s)
Amount
Part-B (Civil, Dismantling & Erection)
Earth work in excavation by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drain including dressing of sides and ramming of bottoms etc. in all kinds of soil including disposal of surplus soil, if any to a suitable place including cost of labour and T&P complete in all respect as per the direction of engineer incharge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering with all works upto plinth level in following ratios including cost of material, labour and T&P complete in all respect as per the direction of engineer incharge.
Ratio 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size).
Ratio 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
12mm plaster work of mix ratio 1:6 (1 cement : 6 fine sand).
M.S. work in heavy section in trenches including cutting, moulding, bending and welding complete in all respect as per the direction of engineer incharge.
Structural steel work riveted bolted or welded in built up sections trusses and framed work including supply, cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Brick work with common burnt clay FPS (non modular) bricks of class designation 7.5 in foundation and plinth in ratio of 1 cement : 4 coarse sand.
Erection of bolted type suspension fitting suitable for ACSR panther conductor.
Erection of PVC copper control cable (Armoured) (2.5mm x 4Core) by laying, cutting, ferruling, termination alongwith perforated cable tray as per the cable schedule including cost of all labour and T&P complete in all respect as per the direction of engineer incharge.
Making jumpering arrangements with ACSR panther conductor by cutting of conductor to required size for jumpering between main/transfer bus bar and equipments including bending, shaping, fixing of required clamp/connector with proper alignment and tightening as per line diagram as per direction of engineer incharge.
Dismantling of old and existing 33KV CTs alongwith their Junction Boxes, cable etc. from existing foundations.
Dismantling of existing lattice type auxilliary structure of 33KV CTs from old foundations.
Erection of galvanized steel lattice type structure with hardware for Bus Post Insulator, Isolators including Nut & Bolts etc.
Erection of old 33KV CTs on new foundation including erection of Junction Boxes and all clamps and connector complete in all respect as per the direction of engineer incharge.
Erection of 33KV Double Break Isolator, 3-Phase, 1250 Amps (Without Earth Switch) complete in all respect as per the direction of engineer incharge.
Erection of 33KV Bus Post Insulator complete in all respect as per the direction of engineer incharge.
Earthing of all main and auxilliary structure and equipment structures complete in all respect as per the direction of engineer incharge.
Complete checking, testing and commissioning of 33KV TBC bay arrangement including testing of CTs, CBs etc. complete in all respect as per the direction of engineer incharge.
Description of Work / Item(s)
Amount
Total Part-A (Supply ) from BoQ1 sheet WITHOUT GST
Total Part-B (Erection) from BoQ2 sheet WITHOUT GST
Add GST* Amount on (Total of Part-A + Total of Part-B above)
RAM RAJ AND SONS
RAM RAJ AND SONS
RAM RAJ AND SONS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .