| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.3 LAdmitted-Finance | ₹79.3 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical 7TH FLOOR DGK 712 DLF GALLERIA ACTION AREA 1 BG 8 NEWTOWN KOLKATA WEST BENGAL 700156 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700156 | - | - | Rejected-Technical Bidder not fulfill the tender criteria |
| Sl No | Description | Qty | Unit | CSK BIO PROJECTS PVT LTD L1 |
|---|---|---|---|---|
| 1.00Civil and Structural works : | ||||
| 1.01 | 1) Modification of the existing HVAC system as per the existing site condition to maintain design parammeter.This job includes necessary modification of ductwork, piping, electrical connections, and structural supports.
All dismantled materials and debris to be removed and disposed as per instruction by the Engineering in-charge. Site preparation work including levelling, excavation, and backfilling as required for new installations. Construction of new foundations and structural supports for HVAC system and other electro-mechanical systems. All civil and structural works to be executed in accordance with the relevant drawing and specification duly approved by concerned Engineering in-charge.
Construction of a new shed to house mechanical equipment. The scope includes roofing, cladding, supporting steel structures, and all necessary civil and structural works. Construction of a dedicated electrical room to accommodate the new MCC panel. Includes all required civil works (walls, roofing, flooring), structural framing, electrical provisions, lighting, ventilation etc. as required as per the site requirement
2) Upgradation of clean room system to keep provision for dedicated air lock room at the main entry corridor area. Air lock room should have minimum difference 5 Pa positive air pressure compare to the dirty corridor and entry corridor.
2.01) Supply, Installation, Testing and Commissioning of Double skin Clean room Wall Cladding, Wall Partition Panel system 80 mm thick , PUF infilled powder coated GI sheet, as per specification complete with concealed conduits for power socket, data, telephone points and necessary factory finished cut-outs for double gazed view panels and doors. Double skin sandwich type GSS/CRCA Powder coated Metallic ceiling panels of 0.6 mm thickness on both sides, PUF in-filled with 40+/-2 Kg/m3 density insulation. Complete with Extruded aluminium powder coated supports and hanging arrangement, with aluminium profiles that create uniform seams. The Partition seams are sealed by RTV silicone with a perfectly flush finishing. PUF insulation material is sandwiched between the two skin layers and sealed from the exterior by the GI frame work including all cut-outs factory fitted, for Air terminals/Diffusers and lighting etc. including necessary utility cut-outs duly concealed, as per specification, including necessary utility factory finished cut-outs duly concealed as per specification
3) Supply, Installation, Testing and Commissioning of Clean room compatible Single Leaf Doors 1200 (W)x2100mm (H) as per specification with door closure, SS-'D' handle, Push plate and kick plate along with 480x750 double glazing view panel & Drop-seal
4) Supply, Installation, Testing and Commissioning 2-Door Interlock system with Electromagnetic Strike lock unit and Egress Button for air lock for entry gate and dirty corridor gate | 1 | Lot | 5,00,000 ₹5 L |
| 2.00AC works : Modular Outdoor TFA Double skin Air Handling Units of 43+/- 2 mm thick PUF injected panels with 24 gauge GI inner skin and pre-coated GI outer skin all as per specification including fan with TEFC motor. AHU shall have Air intake louver combined with pre filter (EU-3), Fine Filter section (EU-9), HEPA filter section (EU-13), coil section with DX 6-Row coil, blower section with DIDW (double inlet double width) centrifugal fan having static pressure of 140 mm/Wg with TWIN MOTOR ARRANGEMENT (1S +1W). The AHU complete in single/double tier construction with Thermal break profile having various sections like Aluminium Fresh air louver section with louver, filter section, fan section, coil section and supply air plenum etc. The AHU having TEFC (totally enclosed Fan Cooled) motor with VFD, Cooling & heating coil, moisture eliminator. AHU should be designed for maximum 2.5m/s face velocity on filters & coils and sections having filters should be provided with necessary port for measuring pressure differential with the help of magnehelic gauge mounted over the AHU itself for regular maintenance of filters. AHU should be provided service windows of suitable width for maintenance of various sections and inspection windows should be provided glass panels for viewing inside the AHU. AHU panel thickness should be 43+/-2mm injected with PUF and sheet thickness should be 22/24. Drain pan of all the AHUs should be dully insulated and material of construction should be 1 mm SS304. Additional safety accessories like Cushy foot mountings, Limits switches for access doors, inspection lamp, Fire proof double canvass connections (Fungal resistant and Lint free) should also be provided along with AHU. | ||||
| 2.01 | AHU - 1 (New) : Supply, Installation, Testing and Commissioning of TFA type 100% FA Unit with 140 mm WG Static pressure - for following rooms :
i) Breeding Room comprising of 3 ventilator suitable for 6 rack
ii) Mice Room-1 comprising of 5 ventilator suitable for 8 rack
iii) Mice Room - 2 comprising of 3 ventilator suitable for 5 rack. (necessary upgradation of the said rooms air circulation to be considered in this unit))
AHU - 2 (New) : Supply, Installation, Testing and Commissioning of TFA type 100% FA Unit with 140 mmWG Static pressure - for following rooms
i) Animal Experimentation Room comprising of 2 ventilator suitable for 4 rack
ii) Office Room to maintain desired room temperature and RH
iii) IN-VIVO Room to maintain desired room temperature and RH
iii) Necropsy Room to maintain desired room temperature and RH (Necessary upgradation of the said rooms air circulation to be considered in this unit) | 1 | Lot | 8,50,000 ₹8.5 L |
| 3.00 | Modification, upgradation of the existing AHU-3 ducting system for the Quarantine Room's air circulation as required design parameter considering two (2) ventilator | 1 | Lot | 2,00,000 ₹2 L |
| 4.00 | EAU-1 (New) : Supply, Installation, Testing and Commissioning of Exhaust 100% EA Unit with 125 mmWG Static pressure, TWIN MOTOR arrangement (1S +1W), dedicated exhaust from the 13 nos IVC-Ventilators should be considered in this EAU unit capacity. Rooms are as follows
i) Quarantine Room : 2 nos
ii) Breeding Room : 3 nos
iii) Mice Room -2 : 3 nos.
iv) Mice Room -1 : 5 nos
EAU-2 (New) : Supply, Installation, Testing and Commissioning of Exhaust 100% EA Unit with 125 mm WG Static pressure, TWIN MOTOR arrangement (1S +1W) dedicated exhaust from the 2 nos IVC-Ventilators should be considered in this EAU unit capacity. Rooms are as follows
i) Animal Experimentation Room : 2 nos. | 1 | Lot | 6,50,000 ₹6.5 L |
| 5.00 | Modification and upgradation of all existing 3 numbers AHU (Air Handling Units) and existing 3 numbers EAU (Exhaust Air handling units) as necessary for the desired design parameters to be kept inside the facility zones | 1 | Lot | 2,50,000 ₹2.5 L |
| 6.00 | Supply, Installation, Testing and Commissioning of Air cooled DX Condensing unit - 5.5 TR X 2 set = 11 TR (2 Working) complete with multiple compressors complete with suitable for operation on R32/R-410A/R-407 Green refrigerant comprising of Scroll type compressor hermetically sealed complete with automatic capacity, safety switches, lubrication system, suitable for operation on 415+10% volts, 50 Hz, necessary support structure including all accessories in all respect. | 2 | Set | 5,25,000 ₹10.5 L |
| 7.00 | Supplying, fixing, testing commissioning of Refrigerant Piping system including Refrigerant Gas charging, Drier filters and necessary valves & fittings including thermal Insulation for 4 sets of new Air cooled Condensing units | 1 | Lot | 1,50,000 ₹1.5 L |
| 8.00 | Air Distribution System :
1) Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal / non-ferrous re-inforce spiral flexible ducting rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, MS painted flanges, all joints sealed with RTD silicon sealant with MS painted supports as per IS-266 with Zinc deposition 120gms/sqm. etc. as per approved drawings and specifications of following sheet thickness complete as required.
1.01) Thickness 0.63 mm sheet / non-ferrous re-inforce spiral flexible ducting
1.02) Thickness 0.80 mm sheet / non-ferrous re-inforce spiral flexible ducting
2) Supplying, fixing testing commissioning of Aluminium Gear Operated volume control dampers for AHU, ducting and exhaust fans
3) Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
19 mm Thickness | 1 | Lot | 5,15,000 ₹5.2 L |
Tender Value
₹79.4 L
EMD Value
₹1.6 L
Closing Date
29 Apr 2026, 5:00 pmClosed
Administrative Officer, CSIR - IICB, Kolkata
CSIR-IICB 4, Raja S. C. Mullick Road, Jadavpur, Kolkata-700032
As per NIT. The full name work / item title, please read in tender document.
2026_CSIR_266578_1
ESD-C/1277/2024-CB and ID-IICB
Open Tender
Miscellaneous Works
120 days
CSIR-IICB, Salt Lake campus
As NIT
4 documents required · 4 mandatory
₹0
₹1.6 L
Yes
CSIR-IICB, Salt Lake campus
19 Jun 2026
23 Mar 2026
30 Apr 2026
23 Mar 2026
29 Apr 2026
13 Apr 2026
7 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Civil and Structural works : | ||||||
| 1.01 | 1) Modification of the existing HVAC system as per the existing site condition to maintain design parammeter.This job includes necessary modification of ductwork, piping, electrical connections, and structural supports.
All dismantled materials and debris to be removed and disposed as per instruction by the Engineering in-charge. Site preparation work including levelling, excavation, and backfilling as required for new installations. Construction of new foundations and structural supports for HVAC system and other electro-mechanical systems. All civil and structural works to be executed in accordance with the relevant drawing and specification duly approved by concerned Engineering in-charge.
Construction of a new shed to house mechanical equipment. The scope includes roofing, cladding, supporting steel structures, and all necessary civil and structural works. Construction of a dedicated electrical room to accommodate the new MCC panel. Includes all required civil works (walls, roofing, flooring), structural framing, electrical provisions, lighting, ventilation etc. as required as per the site requirement
2) Upgradation of clean room system to keep provision for dedicated air lock room at the main entry corridor area. Air lock room should have minimum difference 5 Pa positive air pressure compare to the dirty corridor and entry corridor.
2.01) Supply, Installation, Testing and Commissioning of Double skin Clean room Wall Cladding, Wall Partition Panel system 80 mm thick , PUF infilled powder coated GI sheet, as per specification complete with concealed conduits for power socket, data, telephone points and necessary factory finished cut-outs for double gazed view panels and doors. Double skin sandwich type GSS/CRCA Powder coated Metallic ceiling panels of 0.6 mm thickness on both sides, PUF in-filled with 40+/-2 Kg/m3 density insulation. Complete with Extruded aluminium powder coated supports and hanging arrangement, with aluminium profiles that create uniform seams. The Partition seams are sealed by RTV silicone with a perfectly flush finishing. PUF insulation material is sandwiched between the two skin layers and sealed from the exterior by the GI frame work including all cut-outs factory fitted, for Air terminals/Diffusers and lighting etc. including necessary utility cut-outs duly concealed, as per specification, including necessary utility factory finished cut-outs duly concealed as per specification
3) Supply, Installation, Testing and Commissioning of Clean room compatible Single Leaf Doors 1200 (W)x2100mm (H) as per specification with door closure, SS-'D' handle, Push plate and kick plate along with 480x750 double glazing view panel & Drop-seal
4) Supply, Installation, Testing and Commissioning 2-Door Interlock system with Electromagnetic Strike lock unit and Egress Button for air lock for entry gate and dirty corridor gate | - | Lot | - | - | item2 |
| 2AC works : Modular Outdoor TFA Double skin Air Handling Units of 43+/- 2 mm thick PUF injected panels with 24 gauge GI inner skin and pre-coated GI outer skin all as per specification including fan with TEFC motor. AHU shall have Air intake louver combined with pre filter (EU-3), Fine Filter section (EU-9), HEPA filter section (EU-13), coil section with DX 6-Row coil, blower section with DIDW (double inlet double width) centrifugal fan having static pressure of 140 mm/Wg with TWIN MOTOR ARRANGEMENT (1S +1W). The AHU complete in single/double tier construction with Thermal break profile having various sections like Aluminium Fresh air louver section with louver, filter section, fan section, coil section and supply air plenum etc. The AHU having TEFC (totally enclosed Fan Cooled) motor with VFD, Cooling & heating coil, moisture eliminator. AHU should be designed for maximum 2.5m/s face velocity on filters & coils and sections having filters should be provided with necessary port for measuring pressure differential with the help of magnehelic gauge mounted over the AHU itself for regular maintenance of filters. AHU should be provided service windows of suitable width for maintenance of various sections and inspection windows should be provided glass panels for viewing inside the AHU. AHU panel thickness should be 43+/-2mm injected with PUF and sheet thickness should be 22/24. Drain pan of all the AHUs should be dully insulated and material of construction should be 1 mm SS304. Additional safety accessories like Cushy foot mountings, Limits switches for access doors, inspection lamp, Fire proof double canvass connections (Fungal resistant and Lint free) should also be provided along with AHU. | ||||||
| 2.01 | AHU - 1 (New) : Supply, Installation, Testing and Commissioning of TFA type 100% FA Unit with 140 mm WG Static pressure - for following rooms :
i) Breeding Room comprising of 3 ventilator suitable for 6 rack
ii) Mice Room-1 comprising of 5 ventilator suitable for 8 rack
iii) Mice Room - 2 comprising of 3 ventilator suitable for 5 rack. (necessary upgradation of the said rooms air circulation to be considered in this unit))
AHU - 2 (New) : Supply, Installation, Testing and Commissioning of TFA type 100% FA Unit with 140 mmWG Static pressure - for following rooms
i) Animal Experimentation Room comprising of 2 ventilator suitable for 4 rack
ii) Office Room to maintain desired room temperature and RH
iii) IN-VIVO Room to maintain desired room temperature and RH
iii) Necropsy Room to maintain desired room temperature and RH (Necessary upgradation of the said rooms air circulation to be considered in this unit) | - | Lot | - | - | item4 |
| 3Modification, upgradation of the existing AHU-3 ducting system for the Quarantine Room's air circulation as required design parameter considering two (2) ventilator | ||||||
| 4EAU-1 (New) : Supply, Installation, Testing and Commissioning of Exhaust 100% EA Unit with 125 mmWG Static pressure, TWIN MOTOR arrangement (1S +1W), dedicated exhaust from the 13 nos IVC-Ventilators should be considered in this EAU unit capacity. Rooms are as follows i) Quarantine Room : 2 nos ii) Breeding Room : 3 nos iii) Mice Room -2 : 3 nos. iv) Mice Room -1 : 5 nos EAU-2 (New) : Supply, Installation, Testing and Commissioning of Exhaust 100% EA Unit with 125 mm WG Static pressure, TWIN MOTOR arrangement (1S +1W) dedicated exhaust from the 2 nos IVC-Ventilators should be considered in this EAU unit capacity. Rooms are as follows i) Animal Experimentation Room : 2 nos. | ||||||
| 5Modification and upgradation of all existing 3 numbers AHU (Air Handling Units) and existing 3 numbers EAU (Exhaust Air handling units) as necessary for the desired design parameters to be kept inside the facility zones | ||||||
| 6Supply, Installation, Testing and Commissioning of Air cooled DX Condensing unit - 5.5 TR X 2 set = 11 TR (2 Working) complete with multiple compressors complete with suitable for operation on R32/R-410A/R-407 Green refrigerant comprising of Scroll type compressor hermetically sealed complete with automatic capacity, safety switches, lubrication system, suitable for operation on 415+10% volts, 50 Hz, necessary support structure including all accessories in all respect. | ||||||
| 7Supplying, fixing, testing commissioning of Refrigerant Piping system including Refrigerant Gas charging, Drier filters and necessary valves & fittings including thermal Insulation for 4 sets of new Air cooled Condensing units | ||||||
| 8Air Distribution System : 1) Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal / non-ferrous re-inforce spiral flexible ducting rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, MS painted flanges, all joints sealed with RTD silicon sealant with MS painted supports as per IS-266 with Zinc deposition 120gms/sqm. etc. as per approved drawings and specifications of following sheet thickness complete as required. 1.01) Thickness 0.63 mm sheet / non-ferrous re-inforce spiral flexible ducting 1.02) Thickness 0.80 mm sheet / non-ferrous re-inforce spiral flexible ducting 2) Supplying, fixing testing commissioning of Aluminium Gear Operated volume control dampers for AHU, ducting and exhaust fans 3) Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19 mm Thickness | ||||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.35 MB
TDIVC200326.pdf
Tender Documents • 3.87 MB
BOQ_309764.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid