Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAdmitted-Finance 0 BOSE PARK MAHATMA GANDHI ROAD BHAGALPUR BHAGALPUR BHAGALPUR BIHAR 812001 M G PATH BHAGALPUR 812001 | BHAGALPUR | BIHAR | 812001 | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | KRISHNA SALES CORPORATION L1 |
|---|---|---|---|---|
| 1.00 | SITC of 1.5 TR Split air conditioner (Hot & Cold) to be installed at Personal Officer Chamber of GMC&H, Jammu with all accessories (along with outdoor stand and drain pipe) having below give specifications:
Air Conditioning Technology: Inverter
Min. Star Rating: 3
Max. Cooling Capacity >= 18357 BTU/hr
Ambient upper temperature range >= 52 degree Celsius
Refrigerant: Ecofriendly
Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges.
Make: O-General/Bluestar/Hitachi/Diakin/carrier. | 2 | no. | 45,000 ₹90,000 Lowest |
| 2.00 | Supply, Installation, Testing and Commissioning of 5KVA copper wound automatic wall mounted voltage stabilizer input Voltage 130-280 V & of superior quality ISI mark for ACs.
Make: Microtek/Aulten/Servokon/Electricfield | 2 | no. | 8,900 ₹17,800 Lowest |
| 3.00 | Providing and fitting of extra copper pipe with insulation. | 60 | ft | 550 ₹33,000 Lowest |
| 4.00 | Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting air conditioning units (Outer & Inner) to the Stabilizer. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes. | 20 | mtrs | 60 ₹1,200 Lowest |
| 5.00 | Providing and laying (using conduits and wire fasteners / cable clips) ) of 6 sq mm ISI Marked, FRLS PVC insulated copper conductor cable and of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of interconnecting stabilizers and electrical panel . Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes. | 20 | mtrs | 90 ₹1,800 Lowest |
| 6.00 | Providing and fitting of SPN of 32 Amp of standard make i.e. Havells, L&T or equivalent make, with Gang box (complete with fittings) for, 1.5TR Capacity ACs to be installed. | 2 | no. | 500 ₹1,000 Lowest |
| 7.00 | Providing and laying of PVC drain pipes of assorted sizes viz. ¾”, etc. to collect and transport the drained water from the AC unit to a designated location, considering the specific requirements of the site. The PVC pipes will be installed with appropriate size bends and clamps to ensure proper alignment and secure connections. Job also Includes miscellaneous works Civil works like wall opening to pass ducts & pipes, plastering & refinishing of the same to the original finish as per the site requirements. Complete job as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and tax | 10 | mtrs | 35 ₹350 Lowest |
Tender Value
₹1.7 L
EMD Value
₹3,000
Closing Date
30 Mar 2026, 4:00 pmClosed
XEN MH DIVISION GMCH JAMMU
XEN MH DIVISION GMCH JAMMU
SITC OF AIR CONDITIONING UNITS ALONG WITH ALLIED WORKS TO BE INSTALLED AT PERSONAL OFFICER CHAMBER OF GOVT. MEDICAL COLLEGE HOSPITAL, JAMMU
2026_PWDJK_305684_1
MHDJ/e-NIT 396 of 2025-26
Open Tender
Repair and Maintenance Services
Turn-key
10 days
GMCH
as per e nit
2 documents required · 2 mandatory
₹200
XEN MH DIVISION GMCH JAMMU
₹3,000
18 Apr 2026
9 Mar 2026
31 Mar 2026
9 Mar 2026
30 Mar 2026
11 Mar 2026
9 Mar 2026 - 18 Mar 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: EXECUTIVE ENGINEER, MECHANICAL &-HOSPITAL DIVISION , JAMMU
SITC OF AIR CONDITIONING UNITS ALONG WITH ALLIED WORKS TO BE INSTALLED AT PERSONAL OFFICER CHAMBER OF GOVT. MEDICAL COLLEGE & HOSPITAL, JAMMU
MHDJ/e-NIT 396 of 2025-26 Dated: 09.03.2026 Due : 18.03.2026
Name of the Bidder/ Bidding Firm / Company :
Sl. No. 0 Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATES INCLUSIVE ALL TAXES Excise Duty GST Rs. P Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 SITC of 1.5 TR Split air conditioner (Hot & Cold) to be installed at Personal Officer Chamber of GMC&H, Jammu with all accessories (along with outdoor stand and drain pipe) having below give specifications: Air Conditioning Technology: Inverter Min. Star Rating: 3 Max. Cooling Capacity >= 18357 BTU/hr Ambient upper temperature range >= 52 degree Celsius Refrigerant: Ecofriendly Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges. Make: O-General/Bluestar/Hitachi/Diakin/carrier. 0.000 no. Excess(+) Full Conversion INR
2 Supply, Installation, Testing and Commissioning of 5KVA copper wound automatic wall mounted voltage stabilizer input Voltage 130-280 V & of superior quality ISI mark for ACs. Make: Microtek/Aulten/Servokon/Electricfield 0.000 no. Excess(+) Full Conversion INR
3 Providing and fitting of extra copper pipe with insulation. 0.000 ft Excess(+) Full Conversion INR
4 Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting air conditioning units (Outer & Inner) to the Stabilizer. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes. 0.000 mtrs Excess(+) Full Conversion INR
5 Providing and laying (using conduits and wire fasteners / cable clips) ) of 6 sq mm ISI Marked, FRLS PVC insulated copper conductor cable and of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of interconnecting stabilizers and electrical panel . Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes. 0.000 mtrs Excess(+) Full Conversion INR
6 Providing and fitting of SPN of 32 Amp of standard make i.e. Havells, L&T or equivalent make, with Gang box (complete with fittings) for, 1.5TR Capacity ACs to be installed. 0.000 no. Excess(+) Full Conversion INR
7 Providing and laying of PVC drain pipes of assorted sizes viz. ¾”, etc. to collect and transport the drained water from the AC unit to a designated location, considering the specific requirements of the site. The PVC pipes will be installed with appropriate size bends and clamps to ensure proper alignment and secure connections. Job also Includes miscellaneous works Civil works like wall opening to pass ducts & pipes, plastering & refinishing of the same to the original finish as per the site requirements. Complete job as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and tax 0.000 mtrs Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
techsummary_992770.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
BOQ_992770.xls
BOQ • 0.28 MB
enitTt.pdf
PDF • 0.56 MB
enitTt.pdf
PDF • 0.56 MB
enitTt.pdf
PDF • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .