Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC AT URIMARI P O GOSAI BALIA P S URIMARI DISTRICT HAZARIBAGH JHARKHAND PIN 825311 | HAZARIBAGH | HAZARIBAGH | JHARKHAND | 825311 | ₹18.1 L | L1 | Accepted-AOC Techno-commercial L1 suitable basis |
| 2 | L2₹24.9 LRejected-Finance JHARKHAND | LOHARDAGA | JHARKHAND | 835302 | ₹24.9 L | L2 | Rejected-Finance Commercially not acceptable |
| 3 | L3₹32.2 LRejected-Finance NEAR RELIANCE PETROL PUMP RAMGARH CANTT 829122 DIST RAMGARH JHARKHAND | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | ₹32.2 L | L3 | Rejected-Finance Commercially not acceptable |
| 4 | Rejected-Technical 01 SUBHASH NAGAR POKHRAYAN POKHRAYAN KANPUR DEHAT KANPUR DEHAT UTTAR PRADESH 209111 | KANPUR DEHAT | UTTAR PRADESH | 209111 | - | - | Rejected-Technical Technically not accepted |
| 5 | Rejected-Technical ARGADA RAMGARH JHARKHAND 829101 | RAMGARH | JHARKHAND | 829101 | - | - | Rejected-Technical Technically not accepted |
| Sl No | Description | Qty | Unit | M/s Achal Electricals L2 | Rajneesh Electricals L3 | K.P ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. | 15 | No | 5,530 ₹82,950 | 7,200 ₹1.1 L | 6,500 ₹97,500 |
| 2.00 | Supply, installation, testing and commissioning of Early Streamer Emission (ESE) advance lightning protection system along with accessories with horizontal protection radius of 107m minimum.
1. The system shall comply with the Directorate General of Mines Safety (DGMS) Technical Circular No. 10 of 2020, issued from DGMS, Dhanbad on 23.06.2020.
2. The ESE-based lightning protection system shall provide a horizontal protection radius of 107 meters with a minimum efficiency of 98%, ensuring robust coverage against lightning strikes.
3. The lightning arrestor shall be mounted on a 7-meter mast, complete with high-grade insulators and stay wire accessories to ensure structural stability and electrical isolation.
4. The system shall include a minimum 50 sq.mm single-core copper conductor cable, with a length of at least 50 meters, connecting the lightning arrestor to the earth termination system.
5. A digital lightning strike counter with IP67 ingress protection rating shall be integrated into the system. The counter must operate independently without requiring any external power source.
6. The system shall incorporate two (02) maintenance-free chemical earthing units to ensure effective and long-lasting grounding performance.
7.Each earth pit shall be equipped with a durable PVC or FRP chamber cover to safeguard the earthing components and facilitate inspection and maintenance. | 15 | No | 1,35,000 ₹20.3 L | 1,75,000 ₹26.3 L | 96,000 ₹14.4 L |
| 3.00 | Total impact of GST for the purpose of CTC | 1 | No | - | - | - |
Tender Value
₹31.5 L
EMD Value
₹39,400
Closing Date
5 Nov 2025, 11:00 amClosed
SO(EnM)
GM Office Charhi
Supply, installation, testing and commissioning of Early Streamer Emission (ESE) advance lightning protection system at weighbridges installed within Hazaribagh Area
2025_CCL_346221_1
GM(H)/EnM/Tender/25-26/52
Open Tender
Electrical and Maintenance Works
30 days
Hazaribagh Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹39,400
6 May 2026
25 Oct 2025
6 Nov 2025
26 Oct 2025
5 Nov 2025
26 Oct 2025
26 Oct 2025 - 29 Oct 2025
Amount
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
Supply, installation, testing and commissioning of Early Streamer Emission (ESE) advance lightning protection system along with accessories with horizontal protection radius of 107m minimum. 1. The system shall comply with the Directorate General of Mines Safety (DGMS) Technical Circular No. 10 of 2020, issued from DGMS, Dhanbad on 23.06.2020. 2. The ESE-based lightning protection system shall provide a horizontal protection radius of 107 meters with a minimum efficiency of 98%, ensuring robust coverage against lightning strikes. 3. The lightning arrestor shall be mounted on a 7-meter mast, complete with high-grade insulators and stay wire accessories to ensure structural stability and electrical isolation. 4. The system shall include a minimum 50 sq.mm single-core copper conductor cable, with a length of at least 50 meters, connecting the lightning arrestor to the earth termination system. 5. A digital lightning strike counter with IP67 ingress protection rating shall be integrated into the system. The counter must operate independently without requiring any external power source. 6. The system shall incorporate two (02) maintenance-free chemical earthing units to ensure effective and long-lasting grounding performance. 7.Each earth pit shall be equipped with a durable PVC or FRP chamber cover to safeguard the earthing components and facilitate inspection and maintenance.
Total impact of GST for the purpose of CTC
M/s Achal Electricals (BID ID -1194528)
Rajneesh Electricals (BID ID -1194851)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Document
2.63 MB
BOQ
BOQ • 0.32 MB
Download all tender documents and submit your bid