Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC 116 SHANTINAGAR ROAD BHADRAKALI UTTARPARA HOOGHLY WEST BENGAL 712232 | HOOGHLY | WEST BENGAL | 712232 | ₹1.6 Cr | L1 | Accepted-AOC As L1 Bidder |
| 2 | L2₹1.6 Cr+₹22,321.21 (0.14%)Rejected-Finance | ₹1.6 Cr+₹22,321.21 (0.14%) | L2 | Rejected-Finance Rejected as L2 Bidder |
| 3 | L3₹2.2 Cr+₹64.8 L (40.6%)Rejected-Finance | ₹2.2 Cr+₹64.8 L (40.6%) | L3 | Rejected-Finance Rejected as L3 Bidder |
Tender Value
Refer Docs
EMD Value
₹3 L
Closing Date
26 Mar 2020, 5:00 pmClosed
Superintending Engineer, EC-II
Office of the Superintending Engineer, Electrical Circle- II, EM Sector, KMDA, Block- C, 2nd Floor, Unnayan Bhavan, Salt lake city, Kolkata- 700 091
Design, supply, delivery, installation, testing and commissioning of Air conditioning system comprising VRF equipment of Town Hall at Nabadiganta Township, Salt Lake.
2020_KMDA_275049_1
KMDA/EM/SE/EC-II/NIQ - 07 / 2019-20
Open Tender
MECHANICAL
Item Rate
120 days
Nabadiganta Township, Salt Lake
As Per NIT
8 documents required · 8 mandatory
₹0
₹3 L
11 Jun 2020
26 Feb 2020
30 Mar 2020
28 Feb 2020
26 Mar 2020
28 Feb 2020
Amount
Supply of 415V±10% - 3 Ph - 50 Hz Top Discharge Modular type Variable Refrigerant Flow/Volume system with actual capacity at 40 ⁰C. Outdoor Temperature (Dry Bulb) with Equivalent piping length of minimum 9 Mtr & Piping Lift of 0 Mtr with Inside Dry Bulb 27⁰C, wet bulb 19⁰C. Each Outdoor unit comprises of All Inverter Driven Scroll Compressors, air cooled condenser with protective coated fins, Propeller type Fan with motor. Outdoor must be capable of working within Wide Range of Voltage fluctuation, refrigerant cooled PCB, electronic expansion valve, Outdoor mounting frame, microprocessor panel and other standard accessories as per specification. The unit shall be suitable for operation with R-410A refrigerant. The VRF Outdoor unit must be modular type so that each can be connected with each other. Supplying of Modular type VRF ODU must be connectable with each other and it must act as a single ODU Circuit (if required). Each VRF outdoor unit must consists of 2nos Axial Flow fans. Individual VRF outdoor Model fans must be capable of rejecting Hot Air minimum of 13445 CFM, to achieve below mentioned total cooling HP. The Outdoor unit system must compatible to connect with below mentioned type of AHU through OEM standard AHU connecting KIT.
ODU Size per Unit - Min. 16HP, Max. 32HP
Supply of Ceiling suspended DX type air handling units, 230v / 1ph / 50 Hz, complete with blower section with blower suitable for static pressure as detailed below, cooling coil section with aluminium finned copper tubes cooling coil, filter sections with washable synthetic type air pre-filters efficiency 90% down to 10 micron, belt drive package/direct driven TEFC motor, complete drain connection, drain pan, necessary vibration isolation arrangement etc. complete of following capacities:-
a) 18 TR/6800 CFM/80 Pa External Static Pressure
b) 11 TR/4400 CFM/60 Pa External Static Pressure
Supply of Cassette type indoor units, 230v / 1ph / 50 Hz, comprising of cooling coil, blower, in-built drain pump, filters, decorative grilles. The unit is ceiling suspended type and complete with all other standard accessories.
a) 1.0 TR with minimum 468 CFM with Sound level maximum 36dB(A)
b) 1.5 TR with minimum 488 CFM with Sound level maximum 36dB(A)
c) 1.7 TR with minimum 645 CFM with Sound level maximum 37dB(A)
d) 2.0 TR with minimum 680 CFM with Sound level maximum 38dB(A)
e) 2.8 TR with minimum 940 CFM with Sound level maximum 40dB(A)
f) 3.2 TR with minimum 1080 CFM with Sound level maximum 41dB(A)
Supply of Hi wall indoor units,230v / 1ph / 50 Hz , comprising of cooling coil, blower, filters. The unit is wall mounted type and complete with all other standard accessories.
a) 1.0 TR with minimum 410 CFM with Sound level maximum 29dB(A)
b) 1.5 TR with minimum 421 CFM with Sound level maximum 27dB(A)
c) 1.7 TR with minimum 580 CFM with Sound level maximum 37dB(A)
d) 2.0 TR with minimum 637 CFM with Sound level maximum 37dB(A)
Supply of High Static Pressure Ductable indoor units,230v / 1ph / 50 Hz, of ceiling suspended type, Higher Air quantity, multy fan speed, multy mode function, and complete with all standard accessories. These Ductabble units must have external static pressure from 50 to 120 Pa.
a) 6.0 TR with minimum 2200 CFM with Sound level maximum 53dB(A).
b) 8.0 TR with minimum 3000 CFM with Sound level maximum 55dB(A).
Supply of VRF AHU KIT
Supply of Cordless Remote controller
Supply of Corded Remote controller
Supply of Y joints / Distribution joints for for IDUs.
Supply of Y joints / Distribution joints for for ODUs.
Installation of the VRF outdoor units including vibration isolation pad etc with controls, electricals wirring, local remote switch & necessary accessories of minimum capacity as per design and direction of the EIC.
Installation, testing and commissioning of the AHU as per design and direction of the EIC.
Installation of the AHU KIT as per design and direction of the EIC.
Installation of Cassette Units as per design and direction of the EIC.
Installation of Hi Wall Units as per design and direction of the EIC.
Installation of Ductable Units as per design and direction of the EIC.
Installation of Refrigeration Network (Refnet) joints per sets as required as per direction of the EIC.
Supply installation of Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units & specifications, all piping inside the room shall be properly supported with MS hanger / angle, perforated GI cable tray (18SWG) etc. as required as per design and direction of the EIC.
a) 41.3 mm O.D. with 19 mm insulation
b) 38.1 mm O.D. with 19 mm insulation
c) 34.8 mm O.D.(with 19 mm insulation )
d) 28.6 mm O.D.(with 19 mm insulation )
e) 25.4 mm O.D..(with 19 mm insulation )
f) 22.2 mm O.D..(with 19 mm insulation )
g) 19.1 mm O.D. (with19 mm insulation )
h) 15.9 mm O.D.(with 13mm insulation )
i) 12.7 mm O.D.(with 13mm insulation )
j) 9.5 mm O.D.(with 13mm insulation )
k) 6.35 mm O.D.(with 13mm insulation )
Providing and fixing rigid PVC piping complete with fittings, supports as STD. & specifications and duly insulated with 12 mm thick closed cell nitrile rubber insulation.
a) 40 mm dia
b) 25 mm dia
Supply & fixing of comunication cable along with conduit for looping between indoor & outdoor VRF system & to main Central remote controller system.
a) 2 C X 1.0 mm²
Supplying, installation of GSS ducting of following thickness including necessary supports, adjustable dampers, vanes etc complete as per IS 655.
a) 0.8 mm ( 22 Ga)
b) 0.63 mm (24 Ga)
Providing and fixing 25 mm thick closed cell crossed linked Polyethylene insulation on duct complete with all accessory as required.
Providing and fixing of Duct acoustic lining with 9 mm thick Nitrile Rubber sheet complete with addesive and all accessory as required.
Supplying, fixing, testing & commissioning of powder coated extruded aluminium section supply air grills / diffuser with MS volume control dampers as requied.
Supplying, fixing, testing & commissioning of power coated extruded aluminium section return air grills / diffuser with louvers but without volume control dampers complete as required.
Supplying, fixing, testing & commissioning of fresh air arrangement with volume control dampers, bird screen etc complete as required.
Supply, Installation and Testing of 16 SWG GI Frame / 24 SWG GI aerofoil blades type Volume Control Duct Dampers complete with linkages, fittings, supports, all accessories any other item required to make the system complete.
Providing and fixing fire retardant nonporous double layer flexible connection between each unit and duct.
Supply, Installation & Fixing of Fusible Link type Fire damper
Testing, Commissioning , trial run of the entire VRF system including Nitrogen Flushing, charging of R410A Gas for Topping Up, including Pressure testing & Vaccum. etc. as per direction & satisfaction of the EIC.
MAM ENTERPRISE
UNIVERSAL ENERGY SOLUTIONS PVT. LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .