Loading…
Loading…
Tender Value
Refer Docs
Closing Date
10 Feb 2024, 2:00 pmClosed
Anshul Soni
GAS, Bharat Petroleum Corporation Limited
15214
1000414526
Limited Tender
Works
GAS
7 Mar 2024
27 Jan 2024
10 Feb 2024
27 Jan 2024
10 Feb 2024
27 Jan 2024
Sr. No. ITEM DESCRIPTION UNIT QTY Unit Rate Amount (Rs.)
A GEO-TECHNICAL INVESTIGATION
1 Bore Holes (All Dry/Wet Conditions)
Mobilisation of Man power Drilling Equipment, Accessories, Personnel etc. to Site, Shifting and Setting up of Nos 10 Quoted/Unquoted Quoted/Unquoted
rig at borehole Locations. and Making bore holes up to 35 Metre depth in all type of strata conducting
penetration test, undisturbed soil sampling at 3.0m interval & disturbed soil sampling at 1.0m interval or where
strata changes. Soil investigation report/Geotechnical Survey Up to 35 Meter depth from Ground
level/Riverbed level. Sample Collection will be done at an interval of 1.5 M of each & every boring upto 35 M
depth. This also involves Preserving of soil and rock samples in wooden core boxes and forwarding selected
soil, rock samples to laboratory for testing
Preparing & Submitting 2 Sets of comrehensive Geotechnical Investigation Report including all the parameters
outlined in the scope of work & general specifications. The soft copy of the report shall be submitted in
CD/DVD (2 Nos).
2 Conducting Standard Penetration Tests (SPT) at every 1.5 m Vertical Interval and Collecting / Nos 235 Quoted/Unquoted Quoted/Unquoted
Preserving SPT soil Samples. Collection of disturbed/undisturbed soil samples using thin wall tube
sampler upto the final depth of exploration of each boring. Also, determine the average size of
Boulders/Gravels/Pebbles.
3 Following Laboratory Testing on soil / water samples:
a) Grain size analysis (Hydrometer + Sieve)
b) Natural Moisture Content & Dry density
c) Specific Gravity
d) Atterberg Limit (LL, PL, SL)
e) pH, Chlorides, Sulphates on soil sample
f) Unconfined Compressive Strength Test
Per BH 10 Quoted/Unquoted Quoted/Unquoted
g) Unconsolidated Undrained Triaxial tests
h) Direct Shear Test
i) Vane Shear Test
j) Free Swell Index
k) Modified Proctor Density Test
l) Liquid & Plastic Limit
4 Topography Survey up to 30 Meter width along Pipeline Route
Carrying out Detailed Topographical survey/Detail Engineering Survey along the pipeline route, generation Per KM 2 Quoted/Unquoted Quoted/Unquoted
route profile, survey for all the crossings on the route, submission drawings as per standard route survey norms
up to the length of Stretch (2 km)
TOTAL Quoted/Unquoted
GST @18% Quoted/Unquoted
GRAND TOTAL Quoted/Unquoted
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
15214.pdf
pdf • 3.65 MB
BUDGETDOC_15214.pdf
pdf • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .