Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.3 LAccepted-AOC | 1 | Accepted-AOC lowest bid | |
| 2 | Rejected-Technical KALLANKODAN HOUSE VAKARI PO SULTHAN BATHERY WAYANAD PIN 673 592 | SULTHAN BATHERY | WAYANAD | KERALA | 673592 | - | Rejected-Technical L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical fourth | |
| 4 | Rejected-Technical | - | Rejected-Technical third bid |
Tender Value
₹24.3 L
EMD Value
₹50,000
Closing Date
17 Mar 2025, 5:00 pmClosed
ASSISTANT ENGINEER
LIDEW SULTHANBATHERY MUNICIPALITY
ROJECT NO- 260-SULTHAN BATHERY MUNICIPALITY 2024-25 BEENACHI POOTHIKKADU CHECK DAM KOLAGAPPARA ROAD RENOVATION IN S. BATHERY MUNICIPALITY
2025_LSGD_748062_37
E1-etender-2024-25(4)
Open Tender
Civil Works - Roads
Item Rate
180 days
SULTHANBATHERY MUNICIPALITY
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,760
Yes
₹50,000
Yes
22 Apr 2025
10 Mar 2025
20 Mar 2025
10 Mar 2025
17 Mar 2025
10 Mar 2025
Amount
SIDE PROTECTION
OD270921/2024-2025:Demolishing stone rubble masonry manually by mchanical mans including stacking of serveciable material and disposal of unserviceable material
3.5.2:Excavation in Soil with Dozer with lead upto 100 m <br> Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
3.5.1:Excavation in Cutting in Soil by manual means with lead upto 50 m <br> Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
OD270923/2024-2025:(OD from DAR 60.7.1) DRY RUBBLE MASONRY - Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site ( Using Departmental Material)
OD270933/2024-2025: DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
12.5.3:Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204<br> For height upto 5 m <br> III. R.C.C grade M 20
12.7:Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
OD341293/2024-2025:Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand)
Re tarring 0/690 to 1/460 m from kanarankavala
3.2:Preparation of Foundation for Embankment <br> Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical Means <br> Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
4.11.2:Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal. Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. <br>(ii) Using Gravel mix soil.
4.9:Wet Mix Macadam <br> Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. <br> By Mechanical Means with 1 km lead
75.5.1.1pb:Prime Coat - Low porosity - With Packed Bitumen Rates <br> Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
75.5.2.3pb:Tack Coat - With Packed Bitumen Rates <br> Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
75.5.11.1.A.2pb:Mix Seal Surfacing - Manual Means - Type A - Bitumen S-65 - Packed Bitumen Rates <br> Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509 <br> By Manual Means <br> Type A <br> (II) Bitumen (S-65)
3.3:Construction of Embankment with Material Obtained from Roadway Cutting <br> Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
OD273977/2024-2025:Providing and fixing Name Board fixed over MS sheeting, 2mm thick supported on GI pipe 40 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 300 mmx300mmx500mm below ground level as per drawings and technical specifications Clause 1701. 600 mmx450 mm rectangular .
MALAYORAM LABOURCONTRACT CO OPERATIVE SOCIETY (BID ID -2158360)
SUNIL M M (BID ID -2159975)
SHIBU C J (BID ID -2160011)
Bidder Name
K K SAIDALAVI
SUNIL M M
MALAYORAM LABOURCONTRACT CO OPERATIVE SOCIETY
SHIBU C J
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1209362.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .