Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-Finance EDALAKADU THABORE P O MOOKANNOOR ERNAKULAM DIST KERALA 683 577 | MOOKANNOOR | ERNAKULAM | KERALA | 683577 | L1 | Accepted-Finance Being Lowest | |
| 2 | L2₹20.1 L+₹43,165.50 (2.20%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹20.9 L+₹1.2 L (6.28%)Rejected-Finance 1A BASEMENT 30 31 RAJA HOUSE NEHERU PLACE NEW DELHI | NEW DELHI | NEW DELHI | DELHI | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹21.5 L+₹1.9 L (9.56%)Rejected-Finance BLDG NO XXVIII 378A NORTH CHAMPANOOR ANGAMALI SOUTH P O PIN 683 573 | ANGAMALI | ERNAKULAM | KERALA | 683573 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹26.7 L+₹7.1 L (36.3%)Rejected-Finance 39 359 B PULICKAL THIRUVAMBADY POST ALAPPUZHA KERALA PIN 688 002 | ALAPPUZHA | ALAPPUZHA | KERALA | 688002 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
13 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
PROVISION OF CHANGE OVER SWITCH FOR 62.5KVA DG BACKUP SUPPLY AND OTHERSANCTIONED WORK AT INS DRONACHARYA UNDER GE FORT KOCHI
2024_MES_646385_1
8997/E8_MES_FORT_KOCHI
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FORT KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE FORT KOCHI
₹42,000
Yes
19 Jul 2024
14 Mar 2024
20 Apr 2024
14 Mar 2024
13 Apr 2024
30 Mar 2024
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq. m on plan and n exc 1.5 m indepth and getting out soft/loose soil etc.complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm etc. complete all as specified and as directed.
Removing excavated soil to a distance exceeding 50 m and not exceeding 100m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
M&L hardcore of broken stone or boulders of gauge n.exc. 63mm, deposited, spread and leveled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified & directed.
M&L for plain cement concrete 1:4:8, nominal mix, type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete, all as specified & directed.
M&L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter to give fair finish to flat surfaces complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge.
M&L for mild steel TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hoping for columns and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified.
M&L for RCC (M-30 design mix, using crushed stone aggregate) as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc., basement slabs, under-reamed piles and mass concrete and the like complete all as specified and directed (reinforcement shall be measured and paid for separately).
Excavation over areas not exceeding 1.5m deep and getting out soft and loose soil complete all as specified & directed by Engineer-in-Charge.
Material and labour for 100mm thick PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in sub base etc, finished even and fair complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in flooring, finished even and smooth complete all as specified and directed.
M&L for pre-cast cement concrete block masonry with solid blocks, type C1(1:3:6) using 20mm graded aggregate, exc. 10 cm in width and setting in mortar 1:6, complete all as specified and directed.
M&L for rendering plaster 10 mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement on extra cement on exterior wall etc. complete all as specified and as directed.
M&L for two coats of Antifungal paint (Apex Protek of Asian paint or Equivalent in approved Makes) over a coat of Exterior primer (Professional pack of Asian paints) on new prepared plastered external surfaces and including scafoldings and cradles including hoisting and lowering as required with bracing , support complete all as specified.
S&F mild steel work as in iron post / posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets including all necessary drilling, bolting or riveting etc and similar work conforming to complete all as specified and directed.
M&L for rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe.410 W(Gde-E-250) quality-A,complete all as specified.
S&F Plates 5mm thick or over in thickness in available sizes ,plain or chequered, cut or notched (ordinary and counter sunk) with riveted, with riveted, bolted or welded attachment using Fe.410 W(Gde-E-250) quality-A, complete all as specified and directed.
M & L for preparation of new steel surface over 10 cm width or girth and applying two coat of VX polymer based anti corrosive paint over a coat of anti corrosive primer etc. complete all as specified and as directed.
S&F for mild steel, angles, bars, flats etc, as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties,wind ties, hooks for hanging fans, plain, angle cleats for securing purlins to wood tress or rafters, knee piece inserts, two way and three way staps, plate washers and silmilar small articles confirming to Fe-290 Gde- E-165 complete all as specified & directed by Engineer-in-charge.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strength 550 Mpa as in roof coverings/cladding to wall, fixed with self tapping screws etc complete all as specified & directed by Engineer-in-charge.
S & F 110mm bore PVC (SWR) pipes single socketed in any length with stainless Steel step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls/ laid in floors all as specified and directed.
S&F PVC eaves gutter heavy duty half round 200 mm dia complete all as specified and as directed.
Supply & install of Static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 50 KW (62.5 KVA), water cooled, 415 Volts(AC Three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Fort kochi.(Capacity of Engine, alternators shall be worked outtaking all derating factors into consideration) including PCC foundation( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height above ground level), anti-vibration pad, mechanical governor including all features to comply with latest CPCB guidelines and Comprising of followings:-
(i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection .four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHPto drive Alternator capable of delivering 50 KW (62.5 KVA) at outdoor atmospheric conditions at Fort Kochi. (Taking all derating factor into consideration),, 12/24 Volt(as per manufacturer recommendations) electric battery start, complete with flywheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with mechanical governor and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc complete all as specified and directed.
(ii) ALTERNATOR: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 50 KW (62.5 KVA) Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine complete all as specified and directed.
(iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications complete all as specified and directed..
(v) ACOUSTIC ENCLOSURE: Sheet metal fabricated type enclosure manufactured on CNC machines as per CPCB norms and powder coated after nine tank process, the enclosure shall be designed for reducing the sound level to 75 DL(A) at a distance of 1 M at 75 % load under field condition and , 70db at 3 M from Gen set when DG set is working at full load along with testing , labeling certification complete all as specified and directed. (vi) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M complete all as specified and directed. (vii) Diesel storage tank: Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set complete all as specified and directed.
Supply, installation testing and comissioning of weather and vermin, proof Indoor type Panel box factory made, front & back openable double door type, CPRI approved, fabricated out of 2.0 mm thick CRCA sheet compartmentalized design including mild steel channel frame of ISMC 75 at the base of panel only for grouted with PCC using 20 mm graded stone aggregate, duly epoxy powder' coated, complete with heat shrink able insulated aluminium bus bar of 600 Amps rating 4 nos including all connections with aluminium strips, Pillar box shall be provided with danger notice plate with skull & bone sign, PVC gasketed and sealed, making all incoming and out going electrical cable connecetions with new lugs, glands to be provided at cable entries, including angle iron support 50x50x6 mm with 50 CM height from ground level at the base of panel complete all as specified and as directed. The panel shall be comprising of following accessories: (a) MCCB 415 Volts, 200 Amp , rating 4 Pole, Thermal Magnetic Release type (Service Breaking Capacity 36 KA 1 No (Incoming). (c) Multifunction digital energy meter with RS485 communication port with CTs (d) Phase Indicator lamp assyRYB-01 Set. (b) On load changeover, front operated type, 4 pole , 415 volt of capacity 200 Amps, - 01 No. (c) MCCB 415 Volts, 125 Amp , rating 4 Pole, Thermal Magnetic Release (Service Breaking Capacity 25 KA -02 No. Outgoing. (g) spare compartment of MCCB for future-01 Nos
M&L riddle Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply and lay sub class "B" burnt bricks, as in cable protection, laid length of brick perpendicular to length of cable complete all as specified and directed.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth and getting out in soft/loose soil / floor and making good the disturbed surfaces all as directed and specified
Returning and filling of soil including spreading leveling, watering and ramming in layers not exceeding 25 cm .all as specified and directed
Removing excavated soil to a distance not exceeding 50 meter, not exceeding 1.5 meter above the starting point and depositing where directed.
M&L Galvanised Steel Tubing Pipe 100mm bore , light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc and making good disturbed surfaces, complete all as specified and as directed..
-Ditto- all as per item No.31 but 50mm bore
M&L MCCB 415 Volts, 200 Amp , rating 4 Pole, Thermal Magnetic Release (Service Breaking Capacity 36 KA all as specified and directed
M&L XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 50 sqmm 3.5 core , 1100 volt grade .Heavy grade conforming to IS :7098 (Part 1) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed.
-Ditto- all as per item No.34 but 3.5 core 70 Sq mm
-Ditto- all as per item No.34 but 3.5 core 35 Sq mm
-Ditto- all as per item No.34 but 4 core 16 Sq mm
M & L for Rigid non-metallic PVC conduit of 40 mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. all as specified
Supply and fix ON LOAD change over switch ,415V ,hand operated with sheet metal enclosures 4 pole of capacity 160 Amps. all as specified
Supply, installation, testing and comissioning of weather and vermin proof outdoor type feeder piller box Panel factory made, front & back openable double door type, CPRI approved, fabricated out of 3.14 mm thick CRCA sheet compartmentalized design including mild steel channel frame of ISMC 75 at the base of panel only for grouted wiht PCC using 20 mm graded stone aggregate, duly epoxy powder coated, complete with heat shrink insulated aluminium bus bar of 200 Amps rating 4 Nos, including all connections with aluminium strips, Pillar box shall be provided with danger notice plate with skull & bone sign, PVC gasketed and sealed, making all incoming and out going electrical cable connecetions with new lugs, glands to be provided at cable entries, including angle iron support 50x50x6 mm with 50 CM height from ground level at the base of panel complete all as specified and as directed. The panel shall be comprising of following accessories:- (a) MCCB 415 Volts,63 Amp , rating 4 Pole, Thermal Magnetic Release (Service Breaking Capacity 25 KA 1 Nos (Incoming). (b) Outgoing MCCB 415 Volts,25 Amps, rating 3 Pole, Thermal Magnetic Release (Service Breaking Capacity 16 KA) - 02 Nos. (c) Digital multifunctional meter including CTs-01 No (d) Neon/LED phase indicating lamp(Set of three)-01 Set (e) Dol starter for 3 HP - 01 Nos (f)Spare Compartment for MCB 4 Pole 32 amp - 02 Nos (g) Spare Compartment for MCB SPN 16 amp - 02 Nos
M&L for earthing in repair of complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to Gl strip of 32x6 mm by means of nut, bolts, check nuts and washers of galvanized iron or steel as shown in electrical plate No. 3, including necessary earth work and excavation , charcoal dust, common salt, PCC chamber, RCC cover 40mm thick 1:2:4 using 20mm graded stone aggregate reinforced with 6mm dia round bars 75mm C/C both ways, test point and watering pipe complete, including connecting to earthing test point or to DB / Panel complete as directed by Engr in charge and testing resistance etc complete, all as specified and as directed. Note: (i)The rate quoted shall be deemed to be included for main earth lead from earth electrode to test point up to 7.5 m only. (ii) On testing after completion if the desired earth resistance not cptained as per IE rules the earthing will be redone by the contractor as directed by Engnr in charge with out any extra cost to Govt.
Jack Electrolinks Private Limited
MONA GENERATOR SEVICES PVT. LTD.
K R JOSEPH AND SONS
St George Engineering Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .