Rishi Sachdeva
Executive Engineer,Jag Provincial Division PWD B and R Br Yamuna Nagar
Construction of Additional lift in Deputy Commissioner Office, Jagadhri in District Yamuna Nagar
2020_HRY_124531_6
PWD/CHD/YNGAR/17204
Open Tender
Construction Works
Works
120 days
Yamuna Nagar
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
E.E., Jag. Provincial Division, PWD B and R Br.
₹9,000
11 Dec 2023
25 Sept 2020
9 Oct 2020
26 Sept 2020
8 Oct 2020
26 Sept 2020
165 days
Amount
Earth work in excavation in foundations, trenches, etc. in all kinds of soils, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around mansonry, in 15cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30meters (HSR 6.6)
Cement concrete 1:4:8 with stone aggregate 20mm nominal size in foundation & plinth (HSR 10.38)
First class brick work laid in cement sand mortar 1:6 in foundation & plinth (HSR 11.2)
Steel reinfourcement TMT bars FE-500 EQR/ FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in postion complete in all respect for all heights/ depths/ storeys/ basement etc. Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bar, chair, stays, hangers and annealed steel wire or other methods for bilding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 18.22)
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 meter above plinth level (HSR 11.7) First Storey (HSR 11.7+ 11.41)
Second Storey
Third Storey
Fourth Storey
Cement concrete 1:1½:3 with stone aggregate 20mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects. (HSR 10.86+10.95 (a))+ Note V(b) of chapter-10 (Fourth Storey)
Cement concrete 1:1½:3 with stone aggregate 20mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centering and shuttering , laid in position, complete in all respects. (HSR 10.82+10.95(a))+ V(b) of chapter-10 (Fourth Storey)
Cement concrete 1:1½:3 with stone aggregate 20mm nominal size for reinforced concrete work in Fascias, Parapets and other thin vertical sections, not covered item nos. 10.82, 10.86 to 10.88 of H.S.R not exceeding 10cm thickness excluding steel reinforcement but including centering and shuttering , laid in position complete in all respect (HSR 10.89+ 10.95 a)+ Note V(b) of chapter-10 (Fourth Storey)
Terracing consisiting of tiles 22.86cm x 11.43cm x 3.81cm laid over 87.50mm mud filling on a layer of 25mm mud plaster and an other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65Kg per Sqm on top of RCC slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13)+ Note-3 of Chapter-13 (At fourth Storey)
Top Khurra 0.6 mm x 0.6 mm for rain water pipe in 25 mm thick cemenr concrete 1:2:4 over 50 mm thick cemenr concrete 1:8:16 (HSR 13.50) Second Storey
Third Storey
Fourth Storey
Cement concrete 1:2:4 gola 10 cm x 10 cm quardrant along junction of roof with parapet wall finished smooth, where specially specified (HSR 13.64) First Storey
Third Storey
Fourth Storey
Providing and fixing PVC Rain water pipe 6Kg. Pressure of ISI mark in cement mortar during masonary work. (b) 150mm dia PVC pipe 6 Kg. Pressure. (HSR 13.89 (b) Forth Storey
Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping (HSR 14.04)
Fixing Marble stone flooring 17 mm and above slab including matching grains of marble laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 & jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing & polishing (using marble stone slab of size more than 0.38 sqm each) (HSR 14.49) (.Note: I of Chapter No. 14) Third Floor
Kotah stone flooring 34 mm to 40 mm thick in any pattern as specified over 12 mm thick base of cement coarse sand cement slurry mixed with pigment to match the shade of stone including rubbing & polishing (HSR 14.62) Third Floor
Kotah stone 20 mm thick in skirting risers of steps, dados & walls facing (lining) & pillars laid on 12 mm thick cement coarse sand plaster 1:3 laid & jointed with neat cement slurry, mixed with pigment to match the sahde of stone including rubbing & polishing including labour for fixing cramps, dowels & pins etc. (HSR 14.66) Third Floor
Laying and fixing Granite stone in all shades 15 mm to 18 mm thick in skirting / dado, riser of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of granite including labour for fixing cramps pins and dowels etc. (excluding the cost of granite stone ). (HSR 14.95) Ground Floor
First Floor
Second Floor
Laying and fixing Granite stone in all shades, 15mm to 18mm thick in flooring laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of granite stone excluding the cost of granite stone. (HSR 14.96) Second Storey
Fourth Storey
12 mm thick cement plaster 1:4 on walls (HSR 15.5)+ Note-I of Chapter -15 Fourth Storey
15 mm thick cement plaster 1:6 on the rough side of single or half brick wall (HSR 15.12)+ Note-I of Chapter -15 Fourth Floor
10 mm thick cement plaster 1:4 on under side of celling (HSR 15.52) Third Floor
Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work (HSR 16.58) Note: First quality paint of reputed make firm such as Goodless-Nerolac, Berger, Garware, Jenson, Nicholson Asian & Shalimar Shall Be used as approved by engineer-in-charge in writing drum of paint shall be opened in presence of engineer-in-charge
Providing 2 coats of exterior acrylic emulsion paint Note: First quality paint of reputed make firm such as Goodless-Nerolac, Berger, Garware, Jenson, Nicholson Asian & Shalimar Shall Be used as approved by engineer-in-charge in writing drum of paint shall be opened in presence of engineer-in-charge (HSR 16.79-b) (b) 1st quality
Providing and applying two coats white cement based putty over plastered surface and grinding the surface smooth with sand paper to get and even and smooth finish including cost and carriage of all material, labour charges, scoffolding, sundries etc. complete (J. K./ Birla Make) (HSR 16.81) Note:Reputed make outty such as jk/ birla shall be used as approved by engineer-in-charge
NS ITEMS Providing marbale stone at site of work
providing granite stone at site of wor k(24.72+ 47.29)
Providing & fixing syructural glazing with 6mm thick antelio heat resistant glass (toughened colored glass) make : MODI, SAINTGOBAIN) over farme of aluminium extruded tubular section of jindal/ hidalco make having section (4"x2") 14 gauze Panel size of 4'-0" x 2"-0" the aluminium quality as per garde 6063 T5 or toas per BS 1474 includingsuper durable powder coating of 60-80 microns conforming to AAMA 2604 of rquired colour and shade aluminium section & joints dulty filed with silicon sealer & gasket complete. The rate to be inclusive of cost of meterialsuch as cleats, sleeves, screws, silicon sealant gasket of superior quality etc. necessary for fabrication of extruded aluminium farme work in all respects entire the satisfation of the engineer (Makeof all the constituents like sealant, gasket etc.( Make of all the constituents like sealant, gasket etc. shall be got aproved from engineer-in-charge before application )(N.S)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .