Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹48.4 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹50.0 L+₹51,883 (1.05%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹50.2 L+₹64,105 (1.29%)Rejected-Finance FLAT NO 202 GANGOTRI PARADISE VINAYAKA NAGAR VUDA COLONY GAJUWAKA VISAKHAPATNAM 530 004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹50.8 L+₹1.2 L (2.52%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹51.9 L+₹2.4 L (4.90%)Rejected-Finance M S SRI JAYANTH ASSOCIATES D NO 50 121 18 1 FLAT NO GROUND B SIVA SADAN APARTMENTS BS LAYOUT SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
6 Sept 2023, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
REPAIRS/REPLACEMENT OF ROOF TREATMENT, PARAPETS ALONGWITH ALLIED REPAIR WORKS INCLUDING PERIODICAL SERVICES AND NON STRUCTURAL REPAIRS USING GUNNITING, MICRO CONCRETING ETC, REPAIRS TO VERTICAL STACKS, REMOVAL OF PLANTS/VEGETATION, EXTERNAL PERIODICA
2023_MES_606862_2
C/8212/23-24/E8 / Token 57 of 2023-24
Open Tender
Civil Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹99,800
Yes
28 Oct 2023
21 Aug 2023
8 Sept 2023
21 Aug 2023
6 Sept 2023
30 Aug 2023
Amount
Demolition of reinforced cement concrete in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed.
M & L for use & waste Form work to chajjas, troughs and similar items including edges flat for rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to fins, louvers, fascia, parapets etc for rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.
M & L Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in chajjas etc complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L for Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L for Reinforced Cement Concrete M-30 Design Mix (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, and in shelves and the like etc complete all as specified and directed. (Note: Reinforcement will be measured and paid seperately)
S & F high strength corrosion resistant TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
S & F high strength corrosion resistant TMT steel bars 6mm to 8mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish outside MD land as directed by the Engr-in-Charge.
M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish to outside MD land complete all as specified and directed
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for Complete removal of existing treatment from walls etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7/9 inch to make the surfaces free from dust, loose paints etc by skilled labour complete all as specified and directed.
M & L for applying water proof cement based putty @ 1Kg (undiluted)/Sqm of average thickness 1mm over the plastered/old painted wall after scrapping to prepare the surfaces even and smooth and sanding the putty surfaces with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surfaces free from dus etc by skilled labour as per the following steps complete all as specified and directed: (a) Step 1: Mix the putty powder by adding water as per the manufacturer's instructions and mix it with putty mixer of mixing capacity of min 2.5 Kg putty per minute. (b) Step 2: Apply the first coat of prepared mixer with the help of fully automatic airless spray machine of putty application having glow speed of max 6 ltrs per minute with a maximum pressure 3300 PSI (c) Step 3: Allow 6-8 hrs time to dry the putty surfaces
M & L for applying one coat of acrylic water based interior grade primer @ 0.8 ltr (undiluted)/ 10 Sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with flow speed of min 1 ltr per minute having a pressure of 3300 PSI and allow 6-8 hrs to dry the surfaces for painting of susequent coat complete all as specified and directed.
M & L for applying two coats of oil bound distemper by using fully automatic Airless spray tenchnology machine with max pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be from reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and acccessories for applying distemper in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. (Note: Sanding of surfaces shall be done by mechanical sander with 1500-2700 rpm with internal dust extraction system for clean environment certified by the Paint manufacturer)
M & L for applying one coat of acrylic water based exterior grade primer @ 0.9 Ltr (undiluted)/10 Sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 Ltr per minute having presure of 3300 PSI and allow 6-8 hrs to dry the surfaces for painting of subsequent coats complete all as specified and directed.
M & L for applying Two coats of of water based 100% Premium acrylic smooth exterior emulsion paint with silicon aditive and colour stay technology, excellent Dirt Pick up resistance with low VOC less than 50 gm/litre as per the LEEDS specifications and UV resistance as per IS 15489:2004, Alkali & fungal resistance of required shade (Company Depot Tinted) @ 1.79 Ltr (undiluted)/10 Sqm for two coats diluted with water as per manufacturer instructions with fully automatic airless spray machine of paint application with a flow speed of min 1 Ltr per minute having presure of 3300 PSI and allow 6-8 hrs to dry the surfaces in both the coats of paint complete all as specified and directed.
M & L for preparation old decorated external surfaces of wall, chajja, facia, ceiling parapet etc including cornices, pilasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, effloresecnt salts, trading oil, greasy spots and applying one coat of water based 100% Premium acrylic smooth exterior emulsion paint with silicon aditive and colour stay technology, excellent Dirt Pick up resistance with low VOC less than 50 gm/litre as per the LEEDS specifications and UV resistance as per IS 15489:2004, Alkali & fungal resistance of required shade (Company Depot Tinted) @ 0.90 Ltr (undiluted)/10 Sqm diluted with water as per manufacturer instructions by using Airless spray technology machine with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be from reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and acccessories for applying paint in hard to reach areas and penetration of paint on the surface complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L preparing old decorated surfaces of walls, etc including cornices by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying two coats of white wash complete all as specified and directed.
M & L preparing old decorated surfaces of ceiling, etc including cornices by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying two coats of white wash complete all as specified and directed.
M & L for Preparation of old painted wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
M & L for Preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
M & L for Writing letters or figures (Block ,Roman, Italic or Indian) n. exc 30 cm height with synthetic enamel paint complete all as specified and directed.
M & L for Writing stops, commas, short lines , dashes, hyphens, brackets, etc with synthetic enamel paint complete all as specified and directed.
Complete removing the plants from the surfaces of the building with complete roots, applying recommended chemical to prevent further growth as directed, making good the disturbed surface with cement mortar 1:3 and applying the same surface finish of the existing surface and finished to match with the surrounding surfaces including removal of debris etc., out side the premises complete all as required complete all as specified and as directed.
Dismantling 150mm bore, cast iron or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches if required and as directed.
Dismantling 100mm bore, cast iron or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches if required and as directed.
M & L for 150mm bore, Cast iron, sand cast soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls etc with all fixing accessoriescomplete all as specified and directed.
M & L for 100mm bore, Cast iron, sand cast soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls etc with all fixing accessories complete all as specified and directed.
M & L for 100mm bore, Cast iron, sand cast soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
M & L for 100 mm bore, Jointing only cast iron pipes and fittings or AC pipes and fittings, in repairs, with cement joints complete all as specified and directed.
M & L for 150 mm bore, Jointing only cast iron pipes and fittings or AC pipes and fittings, in repairs, with cement joints complete all as specified and directed.
S & F in repairs, 100 mm bore, Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S & F in repairs, cast iron nahani trap 100 mm dia with grating including jointing to waste pipe fixed in cement mortar 1:2:4 type B2 using 20mm graded aggregate complete all as specified and as directed.
M & L for 150mm bore, cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
M & L for 100mm bore, cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
M & L for 150mm bore, cast iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
M & L for 100mm bore, cast iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S & F in repairs Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 150mm bore of pipe complete all as specified and directed.
S & F in repairs Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100mm bore of pipe complete all as specified and directed.
M & L for Preparation of old external surfaces of cast iron pipe 150mm dia and applying one coat of Epoxy paint complete all as specified and directed.
M & L for Preparation of old external surfaces of cast iron pipe 100mm dia and applying one coat of Epoxy paint complete all as specified and directed.
Taking down eaves gutters and rainwater/soil/waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed.
S & F 75 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc complete all as specified and directed.
S & F 75 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed.
S & F in repair 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S & F 110mm bore, PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed.
S & F 75mm bore, PVC (SWR) junction single, (Single T) equal or unequal with oval access door complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) bends of any radius with oval access door complete all as specified and directed.
S & F 75 mm bore, PVC (SWR) bends of any radius with oval access door complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S & F 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) vent cowl complete all as specified and directed.
Taking up or down 15mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Taking up or down 25 or 32 mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Taking up or down 40 or 50mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Refixing of 15mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 62 above)
Refixing of 20mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 63 above)
Refixing of 25 to 32mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 64 above)
Refixing of 40 or 50mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 65 above)
Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
Supply, laying, connection and testing, 20mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
Supply, laying, connection and testing, 25mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
Supply, laying, connection and testing, 40mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
Supply, laying, connection and testing, 50mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
S & F in repairs, 20 mm bore, gun metal Gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S & F in repair 25 mm bore, gun metal, globe or Gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S & F in repairs, 50 mm bore, gun metal Gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S & F in repairs, 80 mm bore, gun metal Gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
Supply, laying, connection and testing, 25mm outer dia 3- layer PP-R Polypropylene random copo-lymer) concealed pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floors etc complete all as specified and directed
Supply, laying, connection and testing 32mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floors etc complete all as specified and directed
S & F 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
S & F in repairs, 20 mm bore, ball brass valves, high pressure, with polythene float and fly nuts, screwed for iron pipe or brass ferrule complete all as specified and directed.
M & L for preparation of distressed/spalling concrete surfaces as under: (a) Removing plaster and finishes all around the columns, slabs and beams (On all four sides of column to full height, three sides of beam to entire span and bottom of slab to area as directed.) (b) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tools in entire portion of structural member (removal of cover concrete shall be done to an extent reinforcement is visible) (c) Removal of cover concrete with under cutting of upto a depth of 20mm beyond reinforcement around full circumference and full length of bar where directed. (Concrete shall be stripped to an extent concrete substrate is exposed) (d) Removing visible rust along the length of reinforcement using hand tools as approved. (The Engr-in-Charge may order sand blasting if required). (e) Any other work as directed by Engr-in-Charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
M & L for Providing rust proof/anti corrosive treatment to reinforcement bars as under: complete all as specified and as directed. (a) Cleaning all exposed bars (new & old) (b) Apply a single coat of alkaline rust converting primer on alround of bars (new & old) as recommended by the manufacturer (c) Apply two coats of epoxy phenolic anti corrosive protective coat on bars alround (new & old) as recommended by the manufacturer (Note: Anti corrosive treatment shall be continuous especially in the regions where pitting, imperfections etc were present on the surface of the bars. It is important that the rear portions of re-bars (those towards the concrete substance) should not be left without coating. Area of reinforcement for which rust proof/anti corrosive treatment shall be applied is measured.
M & L for providing Polymer Modified Cemntitious Mortar (PMM) as follows: (a) Dry the sub strate surface and clean it free of debris and dust. (b) Apply Epoxy bond coat of the sound sub strate using approved spray machine and ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes) (c) Immedieately after application of epoxy bond coat as above apply PMM (Polymer Modified Cementitious Mortar) of 25mm thickness (Note: Application of PMM shall be preferably be in coats of appx 10mm thick. PMM work shall be executed in fairly rapid successions so as entire work is completed within 30 mins). PMM shall be pre-packed ready to use. (d) PMM surfface to be moist cured for three days followed by air curing in temperature as recommended by the manufacturer complete all as specified and directed. (Make: M/s. Fosroc Chemicals or equivalent approved of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd)
M & L for providing Polymer Modified Cemntitious Mortar (PMM) as follows: (a) Dry the sub strate surface and clean it free of debris and dust. (b) Apply Epoxy bond coat of the sound sub strate using approved spray machine and ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes) (c) Immedieately after application of epoxy bond coat as above apply PMM (Polymer Modified Cementitious Mortar) of 40mm thickness (Note: Application of PMM shall be preferably be in coats of appx 10mm thick. PMM work shall be executed in fairly rapid successions so as entire work is completed within 30 mins). PMM shall be pre-packed ready to use. (d) PMM surfface to be moist cured for three days followed by air curing in temperature as recommended by the manufacturer complete all as specified and directed. (Make: M/s. Fosroc Chemicals or equivalent approved of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd)
M & L for Providing and Pouring Micro Concreting M-40 Grade as under: (a) Dry the concrete substrate surfaces and clean it free of debris & dust. (b) Apply Epoxy bond coat of the sound sub strate using approved spray machine and ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes) (c) Immedieately after application of epoxy bond coat as above pour Micro concreting M-40 Grade (Make: MasterEmaco S46T of BASE or equivalent of Fosroc/Sika/STP/Choksey/Bostik) using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc. Adding of aggregates will be permitted only as per manufacturer's recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, formwork, leads & lifting materials, transportation and scaffolding etc to carry out the complete work complete all as specified and directed. (Note: Measurement shall be considered for circumference at centerline of core thickness)
S & F Additional Reinforcement for repair, rehabilitation work including main bar and stirrups: Supply and Providing extra reinforcement at the area where corrosion has gone above 25% with proper over lapping; Supply of reinforcement steel and fixing using welding or lapping or Dowel or Anchoring system on existing system and placing in position, at all heights & depths of high strength deformed weld-able quality reinforcement bars of Grade Fe-415 or Fe-500 higher grade conforming to IS:1786 (Latest Version) as per drawings for RCC foundations, beams, column, slab and structures, straightening, cleaning, cutting, bending, welding to required shape and length as per details, double binding wire with 16 SWG black soft annealed biding wire, welding if required to form a rigid cage and placing with proper cover block, supports, chairs, spacers etc. complete as directed. HYSD bars of Fe-415 or Fe-500 grade and other higher Grade may also be used. However no extra payment shall be made for different grade of rerinforcment steel used complete all as specified and directed. (Make: HILTI-HIT RE 500 POST INSTALLED REBAR or equivalent approved make (for Rebar Inserting Chemicals))
Demolition of cement concrete (unreinforced) in any position not otherwise specifically provided for as in roof padding etc including old detoriated roof treatment and bedding layer and removing debries and rubbish to a distance outside MD land complete all as specifed and directed.
M & L for brushing neat cement slurry with 3.00 Kg of cement per Sqm complete all as specified and as directed
M & L for Plain cement concrete 1:2:4, type B-0, (using 12.5 mm graded stone aggregate) as in roof kerb or mud stop, benching, levelling course to roof etc rounded or chamfered on edges complete all as specified and directed.
M & L for 10 mm thick, screed bed as in roof in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement mixed with water proofing compound as per manufacturer's instructions complete all as specified and directed. (Note: WPC shall be measured and paid seperately)
Supply and lay polymeric water proofing membrane of weight 3kg/sq.m incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 100gms/sq.m., followed by a coat of blown bitumen of grade 85/25 or 90/15 @ 1.2kg/sq.m. each at top and bottom of the membrane including sealing all joints by thermo fusion with minium 10cm overlap incl grooving & inserting in parapet wall all as per manufacturers instructions complete all as specified and as directed.
M & L for cement concrete tiles of size 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished, including 15 mm thick screed bed in cement mortar 1:6 and set & jointed in neat cement slurry and pointed in with mixture of white and grey cement equal proportion and no pigment complete all as specified and directed.
Supply and lay polymeric water proofing membrane of weight 3kg/sq.m incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 100gms/sq.m., followed by a coat of blown bitumen of grade 85/25 or 90/15 @ 1.2kg/sq.m. each at top and bottom of the membrane including sealing all joints by thermo fusion with minium 10cm overlap incl grooving & inserting in parapet wall all as per manufacturers instructions and applying two coats of aluinium paint over a coat of primer over the top surfaces complete all as specified and as directed.
Sri Shiridi Sai Engineering
RAVITEJA ENGINEERING WORKS
K SATYANARAYANA ENTERPRISES
SRI JAYANTH ASSOCIATES
SRI VIJAYA LAKSHMI ENTERPRISES
JAYAM BUILD CONSTRUCTIONS
K K INFRA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .