Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.1 L+₹1.5 L (6.71%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹24.7 L+₹2.1 L (9.47%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹29.0 L+₹6.5 L (28.6%)Rejected-Finance DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹30.1 L+₹7.6 L (33.7%)Rejected-Finance 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
10 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/MAINT OF ELECT DISTRIBUTION SYSTEM AND OTHER CONNECTED WORKS INCLUDING ATTENDING DAY TO DAY BREAK DOWN AND FUSE OFF CALLS AT NAVAL PARK, AMZARI PARK, NAUSENABAUGH, NCS, MMT (E) AND OTHER MISC WORKS UNDER AGE E/M-I OF GE(U-I) VISAKHAPTNAM
2021_MES_421423_1
8270/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
CLASS D
9 documents required · 9 mandatory
₹500
Garrison Engineer Utility-I
₹87,000
Yes
17 Apr 2021
11 Feb 2021
11 Mar 2021
11 Feb 2021
10 Mar 2021
26 Feb 2021
60 days
Amount
M&L for disconnecting carefully electrical connection from both HT/ LT (primary & secondary) sides of the transformer, keeping them at safe custody , the transformer indoor/ outdoor type of capacity from 63 KVA to 800 KVA , 11 KV/ 0.433 KV, step down any make for carrying out refixing after completion of minor repairs like maintenance / replacement of HT/LT bush, metal rods, lugs, replacement of rusted nutbolts etc including cheking the continuty of HT/LT windings , top cover opening, prevent the all oil leakages, provn of new insulated gaskets / cork sheet for HT/LT supply etc complete all as specefied and directed. Note: Porcelain bushings, gun metal rods, cable end joint kit, transformer oil etc shall be measured and paid separatly under respective items.
M&L for lifting, transporting, handling of the transformer from work site to the workshop / factory incl necessary tools , plants and return back to work site / MES yard / MES store, lifting, handling safely to custody etc after rectifing faults/rewinding /repair / maintenance etc complete all as specefied and directed by Engr-in-charge.
M&L for re-windings of HT distribution transformers of any capacity/ size/ type by strip opening of HT coils (i.e. Primary coils) from core assembly safely, unwinding the HT (i.e. Primary coils) complete, removing the old defective insulation paper, rewindingwith new copper wire of same gauge and existing size together with new DPC insulation to the copper conductor, varnishing of the windings including heating/ drying/ backing complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc. all as directed by Engr-in- charge.
M&L for re-insulating of LT strip of transformers of any capacity/ type by insulating with copper strip as per same gauge and existing size together with new insulated materials/ bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the transformer complete all as directed.
Supply and topping up of transformer oil with di-electric strength not less than 50 KV in to the conservator tank/ body tank of the transformer/ OCB/ FRMUs etc at various locations complete all as directed by the Engineer-in-Charge. [Make: Poweroil/ Transol/ Sabitha Chemicals]
M&L for replacement of the LT porcelain bushings complete of following capacity distribution transformers of existing transformer make/ size/ type all as directed including dismantling old one.
Above 300 KVA to 700 KVA
Up to and including 300 KVA
M&L for replacement of the HT porcelain bushings complete of following capacity distribution transformers of existing transformer make/ size/ type all as directed including dismantling old one.
Above 300 KVA to 700 KVA
Up to and including 300 KVA
M&L for replacement of the HT bushing with gun metal rod with threading & of suitable length/ size all as per existing including metal rings/ bolts/ washers/ rubber rings etc. complete of following capacity distribution transformers of any make/ size/ type all as directed including dismantling old one.
Above 500 KVA to 1250 KVA
Up to and including 500 KVA
M&L for replacement of the LT bushing with gun metal rod with threading & of suitable length/ size all as per existing including metal rings/ bolts/ washers/ rubber rings etc. complete of following capacity distribution transformers of any make/ size/ type all as directed including dismantling old one.
Up to and including 300 KVA
above 300 KVA to 700 KVA
M&L for preparation of old painted surfaces of transformers with coarse cloth/ brush and painting throughout externally on exposed surfaces with two coats of smoke grey colour synthetic enamel paint including complete including one coat of white wash for base foundation all as specified and directed by Engineer-in-charge for the following capacity in-door/ out-door type transformer:-
upto and including 300 KVA
Above 300 KVA to 700 KVA
M&L for replacement of silica gel in breather of transformers for all as directed.
Taking down HT VCB of any make/ capacity, 11 KV, 630A for servicing/ repairs, replacement of defective/ worn out components and refixing back including testing comprising the following:-
(i) Disconneted the vacuum interrupter assembly from VCB panel along with all connections, adjustment of contact gap as required.
(ii) Disconnected socket contacts, cleaning and adjustment of gap, replacement of rings etc.
(iii) Checking the breaker bushing of bus bar and circuit side, inspection/ servicing of internal surface for any arcing/ tracks.
(iv) Checking the epoxy body completely for any cracks, any sign of arcs/ tracks, cleaning thoroughly with CTC including applying Bectrol red varnish.
(v) Checking the drive insulator assembly and inspect for chocking/ tracks/ arcing.
(vi) Taking the IR value of all components,confirm satisfactory results before refixing in VCB panel.
Dismantling the spring charging mechanism of the VCB, checking the entire mechanism for any worn/ crack/ bent/ block/ loose parts etc. for the following:-
(i) Checking the condition of the spring charging motor along with gear box including servicing the motor & replacement of motor bearings if required.
(ii) Checking/ servicing of ratchet wheel assembly, driving and charging parts.
(iii) Checking the auxiliary switch, its contacts for proper functional operation.
(iv) Checking & servicing of raising/ lowering mechanism and its locking system for proper functioning.
(v) Checking & servicing of shutter assembly for its automatic opening/ closing.
The items like nuts, bolts, spring washers, petroleum jelly, CTC etc required to put the breaker in serviceable condition shall be supplied by the contractor and rate shall be deemed to be included in the unit rate quoted.
M&L for de-carbonising/ cleaning of 11KV cubicle type VCB panels consisting of bus bar and circuit chamber, metering chamber, CTs, PTs and relay chamber all as specified below:-
(i) Checking the bus bar and circuit spouts, cleaning with CTC and applying bectrol red varnish to the surface of the bus bar and circuit spouts.
(ii) Checking the CTs/ PTs for any arcing/ tracks, cleaning and applying one coat of varnish.
(iii) Cleaning of metering and relay chamber, checking/ replacement of burnt wires if any, tightening of all connections to arrest the loose contacts.
(iv) Applying mono-plast compound at bus bar joints after tightening all joints/ connections.
M&L for Disconnecting IED of any type/Make from 11kV HT panel, cleaning the contacts , IED configuration , Calibration & Testing of all the measuring & protection devices viz., CTs, Relays and Meters at site. Testing of all the trip functions of the relays after final current settings by simulating fault current by CT secondary injection test set , checking of current transformer , rectification of defects in control wiring for proper tripping of CB during actual system fault conduction through relay & Tripping coil. Adjustment / setting to plug and time multiplier settings of IED to achieve the discrimination in tripping , tune/synchronies upstream breaker relay settings-installation of relay, testing & commissioning etc complete all as specified and as directed.
M&L for Collecting necessary required data & peak load details from IED of any type/Make from 11kV HT panel , Transformer full load details during peak hours. Relay Setting Calculations & Co-Ordination Study. Unit Protection Setting of Transformers. Feeder wise settings has to be furnished & Report with Firm Recommendations to be submitted Down Stream Power distribution (Complete 11 KV system) overall co-ordinations of time need to be achieved. Adjustment / setting to plug and time multiplier settings of IED complete in all as specified and as directed.
Supply of CT's epoxy cast resin , with primary Current 100A - 50A / 1 A - 1A , Secondary current 1A , Dual core , Dual Ratio. Protection core -Class 5P10 & Metering core - Class 0.5 , 2.5 VA . Suitable for SIEMENS make RMU.
Dismantling of existing CT's , Installation of supplied CT's in SIEMENS make RMU & Commissioning by checking of current transformer by primary injection up to 100A.
Supply only the following spares :
LED Indication Lamps
LED type push button actuators
Shunt trip coil 110 V DC / 220 V DC
Breaker Control Switch
Control Circuit fuses 2A to 63A
HRC fuses for PT primary side
Spring Charging motor with gear assembly
Multi function meter , Digital type
Panel Space Heater
Digital Temperature Indicator along with thermostat.
Busbar Support Insulator - 25KA
Finger Type ARMS ASSEMBLY
Main Bus Bar shroud (11kV Grade)
Vaccume Interupter
Contact Spring
Supply of 11kV /√3 / 110v/√3 Potential Transformers
Trpping coil 110 V DC
Closing coil 110 V DC
Battery 3V, 1/2 AA
Decarburizing/cleaning complete 11kV HT Bus bar chamber with electrical connections, complete bus bar from the bus bar chamber , Cleaning with CTC and ensure proper decarburizing up to proper megger value , refixing the same after applying Backtol Red solution to the bus bar insulator & checking all the connections , tightening the nuts , bolts complete incl replacement of defective rusted bolts & nuts all as specified and directed.
Control Wiring up to Control Chamber with 1 Core , 2.5 Sq mm copper cable with proper ferules & appropriate Lugs.
Supply & replacement, calibrating, testing, commissioning of Micro processor feeder protection relay, range - 0.01In – 8In, protection setting- 2 set, protecting circuit correct – 1Amps & 5Amps sets, records history- 5Nos, Min 6 Analog out put, with following protections feeder protection 50/ 51N (3 Phase current), 50/ 51N (Earth Over current), 67 P (3 Phase directional Over current), 6/N (Earth fault directional over current), 51V (Voltage controlled over current) 37 (3 phase under current), 46(Negative phase sequence over current), 59N (Residual over voltage), 49 (Thermal over load), 79(Auto reclose), 50BF( Circuit breaker failure detection), Cold Load pickup, Inrush blocking, Relay will be on MODBUS protocol with LCD display, trip, circuit healthy, alarm, other assignable indication,Auxlary suppy : 110V DC, Make :- Schnieder, Model.P-VAP57
Supply and laying or fixing or passing through pipe or in cable ducts, 11000 volts grade XLPE insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 185 sq mm 3 core size including dismantling old one complete all as specified and directed. Make: Nicco/Havells/Polycab/Gloster
Supply and laying or fixing or passing through pipe or in cable ducts, 11000 volts grade XLPE insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 240 sq mm 3 core size including dismantling old one complete all as specified and directed. Make:Nicco/Havells/Polycab/Gloster
Supply and fix cable jointing kit for 11 KV grade cable for outdoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 240 sq mm complete all as specified and directed. Make: Birla 3M/ Raychem/ Denson
Supply and fix cable jointing kit for 11 KV grade cable for indoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 240 sq mm complete all as specified and directed. Make: Birla 3M/ Raychem/ Denson
Supply and fix cable jointing kit for 11 KV grade cable for outdoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm complete all as specified and directed. Make: Birla 3M/ Raychem/ Denson
Supply and fix cable jointing kit for 11 KV grade cable for indoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm complete all as specified and directed. Make: Birla 3M/ Raychem/ Denson
Supply and fix of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 240 sqmm complete all as specified and directed. Make: Birla 3M/ Raychem/ Denson Note for sl item No. 25 to 29 : Excavation , removal, Returning filling etc to be measured and paid separatly under respective schedule.
Supply and fix or laid in road crossing/ fixed to poles, GI Pipe of 80 mm size light grade for protection of cable incl necessary clamps, nut bolts if required complete all as directed.
Supply and fix or laid in road crossing/ fixed to poles, GI Pipe of 50 mm size light grade for protection of cable incl necessary clamps, nut bolts etc if required complete all as directed.complete all as directed.
Cutting trench through road/ wall to a width of 20cm and depth of 30cm for inserting GI protection pipe for drawing cable and filling back the trench with PCC 1:3:6 type C1 complete all as specefied and directed.
Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade XLPE(FRLS) , armoured, electric power cables (heavy duty) with aluminium conductor of the following size . Note : The rate quoted inclusive of cable glands with suitable aluminium lugs whereever required. Make : Polycab / Finolex /Havells
25 sqmm 4 core
50 sqmm 3.5 core
120 sqmm 3.5 core
185 sqmm 3.5 core
240 sqmm 3.5 core
Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation, trenches for laying cables/ pipe line etc. and getting out in soft/loose soil
Removing excavated materials to a distance n. exc. 50m and depositing where directed at a level n. exc 1.50m above the starting point.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil.
Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed. (Note: Punned thickness only shall be measured)
Supply and laying sub class 'B' bricks of old size (23x11x7cm) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Supply and laying of HT bricks for HT Cable laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
M& L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conducter cable of size incl fixtures and fittings etc for the following sizes complete all as specefied and directed. Make: 3M/Denson/Raychem
3.5 core of 240 sq mm
3.5 core of 150 / 185 sq mm
3.5 core of 90 to 120 sq mm
M&L for detecting HT/LT UG cable faults located in any stretch / depth with cable fault locator consisting of microprocessor based, identification instrument, cable tracer for exact location of under ground cable routes. Notes:- The rate quoted deemed to be inclusive of rental charges for T&P like entire cable fault locating instrument, charges for operator and transportation etc complete.
Supply and replace MCCB 4 pole, 415 V, adjustable type 400Amps with breaking capacity 35 KA including as per site requirment of existing model necessary modification in the panel complete all as specified and as directed. Make: L&T/Seimens/Schneider/Legrand/ IndoAsian
Supply and replace MCCB 3 pole, 415 V, adjustable type 250 Amps with breaking capacity 25 KA as per site requirment of existing model including necessary modification in the panel with proper lugs complete all as specified and as directed. Make: L&T/Seimens/Schneider/Legrand/ IndoAsian
Supply and replace MCCB 3 pole, 415 V, adjustable type 200 Amps with breaking capacity 25 KA as per site requirment of existing model including necessary modification in the panel with proper lugs complete all as specified and as directed. Make: L&T/Seimens/Schneider/Legrand/ IndoAsian
Supply and replace MCCB 3 pole, 415 V, fixed type upto 63 to 100 Amps with breaking capacity 25 KA as per site requirment of existing model including necessary modification in the panel with proper lugs complete all as specified and as directed. Make: L&T/Seimens/Schneider/Legrand/ IndoAsian
Earthing complete with Galvanised Steel earthplate of size 60x60cmx6.3mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, PCC/CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe 40 mm for earth strip in ground etc. all as required at site for complete earthing).
M&L for dismantling the cable connections of four pole/ three pole Air circuit breaker of capacity 630 to 1000 Amps ,415 V 50 HZ of L&T Make/C&S/GE/ABB make, strip opening the Air circuit breaker, inspecting the parts for serviceability/overhauling complete and carrying out the following repairs/maintenance :-
a) Cleaning the insulation parts including bushings with CTC solution.
b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual
c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. Replace the worn-out parts.
d) Check arc chutes for damage and replace damaged parts.
e) Clean and lubricate the operating mechanism with a light machine oil (SAE-20 or 30) for pins and bearings and with a non-hardening grease for the wearing surfaces . Adjust breaker operating mechanism all as per manufacturer's instructional manual . Replace if there is excessive wear and tear.
f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required.
g) Replacing the badly worn or burned contacts. Checking control device free for operation.
j) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional
Note : The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/ pins etc. Major spares like contacts, shunt trip coil , relays, CTs etc will be measured & paid separately under relevant schedule items
Supply only auxiliary contact block suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing of Make: L&T/C&S/ GE/ABB/Kappa
Supply only arcing contacts (fixed/ moving) suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing of Make: L&T/C&S/ GE/ ABB
Supply only arc chutes (for 415 V) suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing of Make: L&T/C&S/ GE/ABB
Supply only shunt release (110 /220 V DC or 240 V/415 V AC) suitable for air circuit breakers of rating 400 to 1000 Amps rated of Make: L&T/C&S/ GE/ABB
Supply only cluster contact suitable for air circuit breakers of rating 400 to 1000 Amps rated all as per existing of Make: L&T/C&S/ GE/ABB
Supply only trip coil suitable for air circuit breakers of rating 400 to 1000 Amps rated all as per existing of Make: L&T/C&S/ GE/ABB
Supply only rating plug suitable for air circuit breakers of rating 400 to 1000 Amps rated all as per existing of Make: L&T/C&S/ GE/ABB
M/s NATIONAL ENGINEERING CONSTRUCTIONS CO
THE VENKATESWARA SUPPLIERS
SRIESWARI ENTERPRISES
MVV Prasad
GVS ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .