Tender Value
₹7.5 L
EMD Value
₹14,960
Closing Date
31 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Banar
Garrison Engineer, Banar, Jodhpur-342027
REPAIR MAINT OF SUMMER COOLLING APPLIANCES AND OTHER CONNECTED WKS AT RALAWAS UNDER GE BANAR
2022_MES_502703_2
8821/34/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer, Banar
₹14,960
Yes
9 Apr 2022
10 Mar 2022
2 Apr 2022
10 Mar 2022
31 Mar 2022
17 Mar 2022
60 days
Amount
M&L for Taking out window type AC of capacity up to 2 Ton from the site of any make for servicing, cleaning with air blower , cleaning and washing fins, Cleaning and descaling of condensing unit cooling coil and evaporative coil with caustic soda mix water,taking out all dirt/sludge etc. by using pressure pump ,cleaning of air filter incl. Oiling and greasing of condensing fan motor including, Replacement of remote cell/battery replacing worn out rubber,bushes/rubber packing rectification of unusual noise. Replacement of minor parts such as nut/bolts,washers etc and reassembly of complete AC unit and testing complete for smooth functioning to entire satisfaction of Engineer-in-Charge.
All as per item No 1 here in above but split type AC of capacity up to 1.5/2 Tons unit all as directed by EIC.
M&L for Topping up of refrigerant as per the existing refrigerant up the required level including oiling for window /split type AC of capacity 1.5/2 Ton all as directed by Engineer in Charge.
M&L for complete Gas charging as per the existing refrigerant up to the required level including oiling for window/Split type AC of capacity 1.5/2 Ton complete all as directed by Engineer in Charge.
M&L for Taking out defective compressor Sealed Rotary / Reciprocating unit of window AC of cap 1.5 Ton incl.cutting of copper tubing without any damage to existing other parts and Material and labour for replacement of compressor/sealed unit complete with erection of compressor in same location with suitable base,jointing of copper refrigerant pipe line,charging of gas to required level,leakage testing etc. including testing for smooth functioning. NOTE : (i)The rate quoted by the contractor shall be inclusive of all charges like transportation,fittings,etc. complete with necessary guarantee period including oiling and environment friendly gas charging , testing etc.complete all as specified and directed by Engineer-in-Charge.
All as per ser No 5 above but window type AC of cap 2 Ton complete all as specified and directed by EIC.
All as per ser No 5 above but split type AC of cap 1.5 Ton complete all as specified and directed by EIC.
All as per ser No 5 above but split type AC of cap 2 Ton complete all as specified and directed by EIC.
All as per ser No 5 above but split type AC of cap (2X1.5 ) 3 Ton complete all as specified and directed by EIC.
M&L for replacement of blower bush of Split type AC having capacities of 1.5/2/2X1.5 Ton complete all as per the sample existing at the ground.
Supply and fix in repair blower fan motor of suitable size for indoor type split AC of cap 1.5/2 Ton complete.
Supply and fix in repair condenser fan motor suitable for out door type split AC of capacity 1.5/2 Ton complete.
M&L for taking out u/s blower of wnidow type AC of cap 1.5/2.00 Ton and supply and fix blower of approved make suitable for existing window type AC of cap 1.5/2.00 Ton all as directed by Engineer-in- Charge.
S&F in repairs of starting capacitor, 45/60 mfd suitable for 1.5 / 2 /2X1.5 Ton capacity window/split type AC of approved make.
S & F in repair capacitor 5/8 mfd suitable for split / window type AC.
M&L for Repairing of PCB control kit of window / split type AC of capacity 1.5/2/2x1.5 Ton complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of PCB control kit suitable for window type AC of capacity 1.00/ 1.5/2.00 Ton complete all as specified and directed by Engr-in-Charge.
M & L for replacement of PCB control kit suitable for split type AC of capacity 1.5/2.00 /2x1.5 Ton unit complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair single pole contactor 25 A, 240 Volts. all as directed by EIC.
Supply and fix in repair double pole contactor 32A, 240 Volts suitable for split type AC of make all as directed by Engineer-in-Charge.
S&F in repairs of Thermostat suitable for split/window type AC 1.5 /2 / 2x1.5 Ton capacity of approved make complete all as specified and directed by Engr-in-Charge.
S&F in repairs of starting and running relay suitable for window /split type AC 1.5/2 /2X1.5 Ton capacity of approved make complete all as specified and directed by Engr-in-Charge..
S&F in repairs of over load protector relay suitable for window/split type AC 1.5 /2 /2X1.5 Ton capacity of approved make complete all as specified and directed by Engr-in-Charge..
M&L for Taking out u/s drain out pipe of split type AC unit and supply and fix new drain out pipe of approved make complete all as directed by Engr-in-charge
Supply and fix in repair of condencing coil of window type AC of capacity 1.5 Ton all as directed by EIC.
Supply and fix in repair of condencing coil of window type AC of capacity 2 Ton all as directed by EIC.
Supply and fix in repair evaporating coil of window type AC of capacity 1.5/2 Ton all as directed by EIC.
Supply and fix in repair evaporating coil of split type AC of capacity 1.5 /2/2X1.5 Ton all as directed by EIC.
Supply and fix in repair of condencing coil unit complete out door type of split type AC of capacity 1.5/2/2X1.5 Ton with approved make all as directed by Engineer-in-charge
Supply and fix in repair single pole and neutral enclousure with a two pin and earth plug and socket along with SP MCB 20 Amps. complete with one single pole MCB complete all as specified and directed by Engr-in-Charge.
M & L for replacement of chocked copper tube of size 1/4" of split type AC 1.5/2/2X1.5 ton cap complete all as directed by Engineer-in-charge
M & L for replacement of chocked copper tube of size 1/2" of split type AC of 1.5 /2.00/2X1.5 ton cap complete all as directed by Engineer-in-charge
M & L for insulation coating /PVC air bubling insulation of circular dia to copper tube to upkeep the required temperture and over all protection to copper tubing of size 1/4" or 1/2" complete all as directed by EIC.
M & L for taking out water Cooler from site of any cap.and make for servicing incl. cleaning of cooling tank and condencing coil with C sine chemical mixed water, taking out all dirt , sludge deposited, incl. oiling / greasing of condensing fan motor rectification of unusual noise, replacement of minor parts such as nut/bolt washers etc as directed with writing of serial No SM/MES No. and re installed the water cooler in position complete all as directed.
M&L for Topping up environment friendly refrigerant suitable for water cooler up to the required level of capacity 40/80 ltr complete all as directed by Engineer-in-Charge.
M & L for complete charging with environment friendly refrigerant suitable for water cooler up to the required level of capacity 40/80 ltr complete alll as directed by Engineer in Charge.
M & Labour for spray painting to water cooler of capacity 80 ltr and cooling capacity 40 ltr per hour by painting outer cover with two coat of synthetic enamel paint of approved make and with writing of sr no/SM/MES No complete all as directed by Engineer-in- Charge.
M&L for Taking out defective sealed compressor unit of 40/80 Ltr/hr cap of water cooler for replacement of sealed compressor unit of suitable for water cooler of 40/80 ltr/hr cap , reassembly and testing complete as to the entire satisfaction of Engineer-in- Charge.
M & L for finding out leakage of condensor/ cooling unit of water cooler of 40/80 Ltr cap including dismantling the same for recharging and stop leakage by brazing/soldering including charging the R-134a gas up to required level and testing complete as to the entire satisfaction of Engineer-in- Charge.
Material and Labour for Replacement of capacitor 10 mfd oil filled for water cooler Make ; Asian/Atlas/Epcos
Supply and fixing starting capacitor clip type of cap 80-100 mfd suitable for water cooler 40/80 lit/hr capacity of make Kell/Tesla/ Shahrda/Escop.
S&F in repairs of over load protector relay suitable for water cooler of cap 40/80ltr/hr of approved make complete all as specified and directed by Engr-in-Charge.
M & L for replacement of condenser Fan motor of water cooler 40/80 ltr/hr capacity as per existing sample or approved make and testing complete all as to the entire satisfaction of Engineer-in-Charge.
M & L for replacement of fan blade of water cooler/blower as per existing sample at the ground complete all as directed by Engineer-in-Charge.
S & F in repairs of Thermostat suitable for water cooler 80/40 Ltr/hr capacity of approved make complete all as specified and directed by Engr-in-Charge.
Material and Labour for brass float valve 15 mm bore with PVC float, ball I.S.I Marked complete with check nut /socket/GI nipple directed by Engineer -In -charge
M&L for replacement of defective sealed compressor unit of 165/215 /315/320 Ltr cap refrigerator. The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee period including checking and rectification of any leakage in system and make it functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete.
M&L for finding out leakage with the pressure testing of the condensor/ cooling unit/ compressor of refrigerator of 165/215/310/320 Ltr cap including dismantling the same for recharging and stop leakage by brizing/soldering including charging the environment friendly refrigerant up to the required level and testing the refrigerator for the entire satisfaction of EIC.
M&L for replacement of defective sealed compressor unit of 320 ltr cap deep freezer. The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee period including checking and rectification of any leakage in system and make in functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete.
M&L for finding out leakage with the pressure testing of the condensor/ cooling unit/ compressor of deep freezer 320 Ltr cap including dismantling the same for recharging and stop leakage by brizing/soldering including charging the R-134A gas to required level and testing the refrigerator for the entire satisfaction of EIC.
M& L for AC Mechanic to Attending the daily complaints which includes the following (Complaint pertaints to ACs/ water coolers/ Refrigerator/ Deep freezer (i) Checking elect circuit, tightning of loose elect connection including internal circuit of plant/equipments and ensure the functioning of the plant. Note :- (i) Spare parts if any required shall be measuread and paid separetely under relevent items of this schedule. (ii) Sealing of unit with thermocol/ packing material shall be part of the job at no extra cost.
Supply and fix in repair outer body for window type AC 1.5 / 2.0 TR comprising double shaft blower motor with fan blade and electrical accessories all as specified and directed MAKE: LG, Carrier, Samsung, Voltas, Hitachi.
Supply and fix in repair front grill for window type AC 1.5 /2.0 TR. Complete all as specified and directed MAKE: LG,Carrier,Samsung,Voltas,Hitachi.
M&L for servicing of Packaged type AC's of capacity 5.5 Ton at site, it includes servicing, cleaning with air blower , cleaning and washing fins, Cleaning and descaling of condensing unit cooling coil and evaporative coil with caustic soda mix water, taking out all dirt/sludge etc. by using pressure pump, cleaning of air filter incl. Oiling and greasing of condensing fan motor, Replacement of remote cell/battery replacing worn out rubber, bushes/rubber packing rectification of unusual noise. Replacement of minor parts such as nut/bolts,washers etc and reassembly of complete AC unit and testing complete for smooth functioning to entire satisfaction of Engineer-in-Charge.
M&L for servicing of Packaged type AC's of capacity 8 Ton at site, it includes servicing, cleaning with air blower , cleaning and washing fins, Cleaning and descaling of condensing unit cooling coil and evaporative coil with caustic soda mix water, taking out all dirt/sludge etc. by using pressure pump, cleaning of air filter incl. Oiling and greasing of condensing fan motor, Replacement of remote cell/battery replacing worn out rubber, bushes/rubber packing rectification of unusual noise. Replacement of minor parts such as nut/bolts,washers etc and reassembly of complete AC unit and testing complete for smooth functioning to entire satisfaction of Engineer-in-Charge.
M&L for Topping up of refrigerant as per the existing refrigerant up the required level including oiling for packaged type AC of capacity 5.5/8.0 Ton. complete all as directed by Engineer in Charge.
S& F for replacement to unserviceable cordless remote with new suitable for machine of 1.5/2.0 TR split type AC complete all as specified and as directed by Engineer-in-Charge.
S& F for replacement to unserviceable Display ckt suitable for 230volt , AC supply with new suitable for 1.5/2.0 TR split type AC complete all as specified and as directed by Engineer-in-Charge.
Strip opening of voltage stablizer 0.5/1KVA for repair including assembling , testing after repair work complete all as specified & as directed by Engineer -in-Charge. Note :- Spare parts like as Transformer , circuit board, relay, control switch & voltmeter etc shall be measured & paid as supply only under item no 65 to to 76 . Fixing charges shall also deemed to be included in the unit rate of above items No 62 to76 of Schedule . Nothing extra admissible on this acccount.
All as pe above item No 62 here-in- before but 2/3KVA
All as per above item No 62 here-in- before but 4/5KVA
Supply only transformer suitable for 0.5/1/2KVA
Supply only transformer suitable for 3/4/5KVA
Supply only Circuit board suitable for 0.5/1KVA
Supply only Circuit board suitable for 2/3KVA
Supply only Circuit board suitable for 4/5KVA
Supply only relay suitable for 0.5/1KVA
Supply only relay suitable for 2/3KVA
Supply only relay suitable for 4/5KVA
Supply only Control pannel suitable for 0.5/1KVA
Supply only Control pannel suitable for2/3KVA
Supply only Control pannel suitable for4/5 KVA
Supply only Voltmeter suitable for0.5/1/2/3/4/5 KVA
vinayandsons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .