Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹23.7 L+₹61,360.50 (2.66%)Rejected-Finance PLOT NO 127 3 A RATNASAGAR FLATS SECTOR 19 GANDHINAGAR 382019 | GANDHINAGAR | GANDHINAGAR | GUJARAT | 382019 | L2 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | L3₹23.8 L+₹72,664 (3.15%)Rejected-Finance | L3 | Rejected-Finance Other Than Lowest Bidder | |
| 4 | L4₹23.9 L+₹77,587.25 (3.36%)Rejected-Finance 9 SHUBHASH BHAWAN RAJENDAR MARG MOUNT ABU 307 501 | MOUNT ABU | SIROHI | RAJASTHAN | 307501 | L4 | Rejected-Finance Other Than Lowest Bidder | |
| 5 | L5₹24.0 L+₹86,660.75 (3.75%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L5 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
24 Jun 2021, 6:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) CHILODA
VAYU SHAKTI NAGAR CHILODA- 382042
CLEANING OF SOAKAGE WELL SEPTIC TANK, SEWAGE LINE AND OTHER MISC B/R WKS AT VSN CHILODA
2021_MES_433785_3
8902/21-22/E8
Open Tender
Civil Works
Item Rate
273 days
Chiloda
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE (AF) CHILODA
₹50,000
Yes
14 Jul 2021
17 Jun 2021
26 Jun 2021
17 Jun 2021
24 Jun 2021
19 Jun 2021
60 days
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sqm on plan and n exc 1.5 in depth and getting out in soft soil.
All as per item No. 01.00 above, but depth exceeding 1.50m.but not exceeding 3.00m complete.
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exceeding 25 cm thickness in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Demolition of brick work of any description and in any position , built in cement mortar.
M&L for brick work with fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in CM 1:6 complete all as specified.
M&L for providing precast cement concrete louvers and jallies, 35mm thick (measured solid) including all mouldings but excluding frame in CM 1:6 Type B0 1:2:4 (12.5 mm graded aggregate) (Pre cast frame shall be measured separately) incl taking down old one complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster on brick or stone masonry wall etc incl racking out joints haking for key, scrubbing down with water etc as in internal and external surfaces of man holes, septic tank, filter bed, drains, walls, paver blocks etc complete all as specified and as directed.
M&L Rendering 15mm thick on brick or concrete surfaces of walls in CM (1:4) including finishing the surfaces even and smooth without using extra cement using WPC @ 3% of cement mortar as in manholes,septic tank, filter bed out let drain, wall etc complete all as specified and directed by Engineer-in-Charge. (WPC will be measured and paid separately)
M&L for 15 mm thick rendering in CM 1:6 on concrete surfaces / fair faces of brick masonary wall, finished even and smooth without using extra cement complete all as specified.
M&L for preparation of new painted surfaces of wall / concrete surfaces over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of priming paints plaster coat complete all as specified and directed by Engr-in-Charge.
M&L for two coats of cement base paint on new plastred surfaces of walls and applying a coat of chalk whiting incl preparation of surfaces complete all as specified.
Supply only water proofing compound (ISI marked).
Demolition of cement concrete of any description and in any position (un reinforced) not otherwise specifically provided for complete all as specified and directed.
M&L for PCC 1:3:6 type C-1, (using 20mm graded crushed stone aggregate) as in coping, cills, steps, bed plates, kerb, benching of manhole and similar work including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1, (using 20mm graded crushed stone aggregate) as in lintels, bend, etc as in Jafri wall /precast jallies and similar work etc including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. (Note: Reinforcement shall be paid separately)
M&L for Plain Cement concrete(1:2:4) using 40mm graded aggregate as in surface channels and drains and similar works etc complete all as specified.
Demolition and breaking up 150 mm bore SGSW drain pipe set in cement mortar including haunching and bed concrete complete all as specified and directed.
All as per Item No.18 above, but 200 mm bore pipe.
All as per Item No. 18 above, but 250 mm bore pipe.
All as per Item No.18 above, but 300 mm bore pipe.
M&L for 150 mm bore salt glazed stone ware (SGSW) drain pipe, of grade 'A' laid in trenches and jointed in CM 1:1 all as specified and directed.
All as per Item No.22 above, but 200 mm bore pipe.
M&L for reinforced concrete pipe,class NP-2, 200mm bore pipe, laid and jointed complete with collars, jointed with cement mortar (1:1) all as directed .
All as per Item No.24 above, but 250 mm bore pipe.
All as per Item No.24 above, but 300 mm bore pipe.
M&L for bedding to drain pipes including packing under pipe, and haunching against both sides in PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) against the side of SWG/RCC pipes after they are laid and tested for 150 mm bore pipe all as specified and directed.
All as per Item No.27 above, but for 200 mm bore size RCC/SWG pipe.
All as per Item No.27 above, but for 250 mm bore size RCC/SWG pipe.
All as per Item No.27 above, but for 300 mm bore size RCC/SWG pipe.
M&L for cutting into existing manholes for connecting new drain, making good to pipe and rendering , cutting out existing benching for forming brackets channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) and reforming benching as required for 150 mm bore SWG/RCC pipe complete.
All as per Item No.31 above, but for 200 mm bore size RCC/SWG pipe.
All as per Item No.31 above, but for 250 mm bore size RCC/SWG pipe.
All as per Item No.31 above, but for 300 mm bore size RCC/SWG pipe.
M&L for cleaning of 100 users brick/stone masonary septic tank, removing sludge and taking out from the septic tank, loading in lorry/cart , depositing beyond the limit of MD land including bailing out water either manually or mechanically including obtaining earth from outside MD land and spreading over the area to cover bailed water complete all as specified and directed.
Dewatering of foul water from soakage pits of size 3.6 M dia and 6.0 M deep by manually or mechanically for removal the same outside MD land all as directed by Engr in Charge.
Removal of blockage in sewage line from WC / floor trap to first manholes, gully trap, etc with sectional / flexible rod or steel or bamboo or through mechanical sewage cleaning apparatus and finally washing with fresh water complete all as directed by Engr-in-Charge.
Cleaning of manhole of size 600mm to 1000mm depth by bailing out water taking out sludge & removing the sludge out side M.D land complete.
All as per Item No. 38.00 above, but for manhole of size 1000 to 2000 mm depth complete.
All as per Item No. 38.00 above, but for manhole of size 2000 to 3000 mm depth complete.
Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in drain cover manholes cover, cover slab for soakage well / and similar works supported on walls and set in cement mortar 1:4 including necessary form work complete all as specified and as directed by Engr in charge.
M&L TMT bars 8 mm dia , cut to length ,bent to shape required including cranking bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and directed.
M&L TMT bars 10 mm dia and over , cut to length ,bent to shape required including cranking bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and directed.
M&L for Mild steel Round Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde -E-165) bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Cleaning of sewage line of stoneware pipe and RCC pipe between two consecutive manholes or gully trap to manhole by rodding and flushing water in line after rodding to clean the line for 150mm dia pipe complete.
All as per Item No. 46 above, but for 200 mm bore pipe complete.
All as per Item No.46 above, but for 250 mm bore pipe complete.
All as per Item No.46 above, but for 300 mm bore pipe complete.
Dismantling of cast iron/ PVC or reinforced concrete drain pipe of 75 to 110mm dia of any description incl high rise bldgs etc complete all as specified.
S&F cast iron soil waste and vent pipe 100mm bore sand cast pipes with or without ears fixed to walls existing pipe in repairing.
All as per desription of srl No 51 above but for 75mm dia pipe.
Extra over cast iron pipes and fittings for providing lead joints in lieu of cement joints for 100mm dia bore.
All as per item No 53 but for 75mm dia pipe.
S&F CI cover for oval access door for 100mm dia pipe with bolts incl taking down of old broken cover.
All as per description of Ser No 55 but 75mm dia.
S&F in repairs PVC 110 mm bore Rainwater drainage pipes , waste, soil ,(SWR) PVC SWR pipes single socketed in any length with rubber ring joints fixed to wall incl high rise bldg etc complete all as specified and directed.
S&F in repairs PVC 75 mm bore Rainwater drainage pipes , waste, soil ,(SWR) PVC SWR pipes single socketed in any length with rubber ring joints fixed to wall incl high rise bldgs etc complete all as specified and directed.
S&F in repairs PVC (SWR) bends 110mm bore any radius
S&F in repairs PVC (SWR) bends 75mm bore any radius
S&F in repairs PVC 100mm bore (SWR) coupler
S&F in repairs PVC 75mm bore (SWR) coupler
S&F in repairs Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100/110 mm dia pipe incl high rise bldgs etc complete all as specified.
S&F in repairs Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm dia pipe.
Dismantling fencing wire mesh of any type or descrption etc complete all as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Excavating in post holes each n exc. 0.50 cum, getting out in soft/loose soil including removing excavated soil and spreading, levelling in layers not exc 25 cm complete all as specified as directed by Engr-in-charge.
M&L cement concrete 1;3:6 type C-2 (using 40 mm graded stone aggregates) as in foundation for fencing post complete all as specified
S&F Mild steel post and struts with angle iron of any description including MS Flat iron of size 40x6mm as in tie bar for fencing post including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165, complete all as specified.
Supply only MS round bar 10mm dia and over as in line wire of fencing mesh conforming to Fe-290 (Gde E-165) complete all as specified.
S&F mild steel screw bolts (machine made), 10mm diameter of neck with hexagonal or square heads at one end and screwed the other , or secured both ends, each screwed end to be fitted with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut , but length of bolt exc 5 cm and n exc 10 cm long complete all as specified.
Supply only Chain Link Fencing MS galvanised fencing any size or type complete all as specified and as directed.
Fixing only Chain Link Fencing including line wires, any mesh, size and type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed.
M&L for framed work such as grills grating, Gates etc with ends of bars shoulders and or riveted or foged into spikes framed guard bars barred iron door, ladders, framed balusters, walk ways railing frame work or water tanks and similar work conforming to Fe-290 grade-165 complete all as specified.
M&L for 2 coats of synthetic enamel paints on steel surface exc. 10 cm width or girth over a coat of red oxide complete all as specified and as directed.
Demolition of stone slabs & tiles of any thickness & in any position laid, bedded and pointed in any mortar otherwise specified.
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thick ness (un reinforced)(below or above ground level) complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base of floor , mass concrete or similar work including necessary formwork complete all as specified and directed.
M&L for chequered cement concrete tiles of size 20cm x 20cm x 25mm / 30cmx30cmx25mm thick,set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20 mm thick screed bed or bedding layer in cement mortar 1:6 complete.
M&L for sand filling/sand cushioning of interlocking tiles under floors or in foundations of any description of work including watering and consolidation complete all as specified.
M&L for machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment conforming to IS-15658-2006 of 60mm thickness M-35 grade complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment conforming to IS-15658-2006 of 80mm thickness M-35 grade complete all as specified and directed.
M&L for Pre-cast cement concrete / paver block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete Type B1 1:2:4 (20 mm graded aggregate) set in CM 1:4 complete all as specified.
M&L for preparation of old painted surfaces of wall / concrete surfaces over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of priming paints plaster coat complete all as specified and directed by Engr-in-Charge.
divyarsh entrprise
nirman construction
Haritwal traders
ALBA AC AND REF SERVICES
Agarwal and Company
Navkar Enterprises
Shree Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .