Interior and Furniture works of Placement Office at Indian Institute of Management Ahmedabad.
2025_IIMA_856510_1
IIMA/Contracts/TW-002/2025-25
Open Tender
Miscellaneous Works
Item Rate
Indian Institute of Management Ahmedabad.
Kindly Refer Tender Document
8 documents required · 8 mandatory
₹0
₹1.4 L
Yes
Indian Institute of Management Ahmedabad.
13 Jun 2025
12 Apr 2025
5 May 2025
12 Apr 2025
3 May 2025
21 Apr 2025
12 Apr 2025 - 17 Apr 2025
17 Apr 2025
Amount
Note: Proposed Site (Placement Office) is situated on ground floor in new IIMA campus. Work shall be carried out without causing disturbance to the occupants of the operational campus. The contractor shall plan working hours accordingly to minimize disruptions. Site visit is required before participating in tender process.
DISMANTLING AND REMOVAL OF EXISTING ITEMS
Dismantle and remove all internal existing walls, false ceilings, flooring, partitions, panelling, pelmets and doors ensuring proper segregation and disposing off outside IIMA Campus at locations approved by local authority as per their rule. The scope of work shall include all necessary lead and lift requirements for material handling and transportation.
Contractor to quote for salvage value of disposed items mentioned in Sr. No. 100.1
Treatment for Dampness
8mm thick Cement sheet cladding on existing wall with GI framework including necessary dampness proof coating on the existing wall
ANTI-TERMITE TREATMENT
Post-construction anti-termite treatment shall be carried out by injecting approved chemical solutions after thorough surface preparation. Drilling shall be done at specified locations such as plinth walls, internal walls, and around doors and windows at intervals of approximately 300 mm along the wall and floor junctions. The drilled holes shall be capped and sealed with white cement or grout to establish a continuous chemical barrier along the internal perimeters and around wood-based structures, effectively eliminating existing termite infestations and preventing future attacks. The treatment shall include all materials, chemicals, equipment, tools, personal protective equipment (PPE), labour, and all associated costs. On completion of the application, the area shall be thoroughly cleaned and maintained as per the instructions of the Engineer-in-Charge. The contractor shall provide a written warranty for a period of three years against termite infestation.
MASONARY WORK General Notes: The scope of work includes curing, scaffolding, raking or flush jointing, and all necessary incidental works to complete the masonry at all floors, levels, heights, and locations, encompassing loading, unloading, stacking, transporting, hoisting, and erecting by any means (mechanical or manual), as per the approved drawings and instructions of the Engineer-in-Charge.
Providing and laying conventional full brick masonry in the superstructure using common burnt clay bricks conforming to IS 1077:1992, having a minimum compressive strength of 35 kg/cm². Masonry to be executed in cement mortar of 1:5 proportion (1 part cement : 5 parts coarse sand), constructed to required shapes, sizes, and thicknesses as per approved architectural and structural drawings. All work to be carried out true to line, level, and plumb, and as directed by the Engineer-in-Charge.
Providing and laying conventional full brick masonry in the superstructure using common burnt clay bricks conforming to IS 1077:1992, having a minimum compressive strength of 35 kg/cm². Masonry to be executed in cement mortar of 1:4 proportion (1 part cement : 4 parts coarse sand), constructed to required shapes, sizes, and thicknesses with RCC band at lintel level as per approved architectural and structural drawings. All work to be carried out true to line, level, and plumb, and as directed by the Engineer-in-Charge.
PLASTER WORK
Supply and application of a 12 to 15 mm thick single-coat cement plaster with a trowel finish on brickwork, blockwork, RCC surfaces, and other designated areas using cement mortar in a 1:3 mix ratio (1 part cement : 3 parts coarse sand). The work shall be executed in all shapes, at all floors, and at all heights, with necessary scaffolding, finishing, and curing. The scope includes proper surface preparation by hacking RCC surfaces and applying a bonding agent where required. It also includes making grooves, forming pattas, and fixing GI hexagonal chicken mesh (20 mm x 20 mm aperture, 22 gauge, minimum 200 mm wide) at RCC-masonry junctions or between different materials. Additionally, a minimum 150 mm wide, 145 GSM alkali-resistant fiberglass mesh shall be provided at plumbing and electrical chasing areas, as well as at corners, doors, and window joints, secured with GI nails as per the manufacturer’s specifications. The rate shall be inclusive of all labour and materials, including surface preparation, bonding agents, chicken mesh, fiberglass mesh, groove/drip moulds as per drawings, and all incidental works necessary for the proper completion of the plastering, as per the approved drawings and instructions of the Architect and Engineer-in-Charge.
Supply and application of an average 12 mm thick premixed, formulated one-coat lightweight gypsum plaster containing additives and lightweight aggregates such as vermiculite or perlite, conforming to IS: 2547 (Part I & II) - 1976. The plaster shall be applied on smooth or uneven surfaces, including bare brickwork, blockwork, RCC walls, columns, and other designated areas of any shape and size, at all floors, heights, and locations. The finish shall be in a smooth line and level as per approved drawings. The scope of work includes surface preparation, hacking of concrete, and the application of a bonding agent on concrete surfaces before plastering. A 145 GSM alkali-resistant fiberglass mesh shall be provided as per manufacturer’s specifications at the junctions of different materials, plumbing and electrical chasing areas, corners, and door and window joints. For areas requiring approximately 25 mm thick gypsum plaster as per drawings, the contractor shall apply a base coat of 12 mm thick gypsum plaster, fix fiberglass mesh over the entire surface, and then apply a second coat of 12 to 15 mm thick gypsum plaster to achieve a flush finish with adjoining exposed concrete elements. In such cases, the entire double-coated plastered area shall be measured and considered twice for payment. The rate shall be inclusive of all labour, materials, bonding agent, fiberglass mesh, groove formations as per drawings, scaffolding, and all associated works necessary to complete the plastering as per the instructions of the Engineer-in-Charge.
Flooring Supply and installation of 25 mm thick machine-cut, polished Kota stone of uniform green shade, matching the existing Kota stone flooring. The stone shall be of size up to 600 mm or as per design requirements, laid in the specified pattern as per approved drawings. The flooring shall be set over an average 50 mm thick bedding layer of cement mortar (1:4 – 1 part cement : 4 parts coarse sand) and jointed using a paper joint with grey cement slurry mixed with matching pigment to ensure uniformity with the stone slabs. The work shall include proper curing, rubbing, and polishing to achieve a smooth and even finish, ensuring compliance with the approved design and the satisfaction of the Engineer-in-Charge. The quoted rate shall include the supply of Kota stone (as per the approved sample), cement mortar bedding, cement slurry, matching pigment, and all necessary labour, materials, and execution. However, filling of joints with epoxy grout shall be measured and paid separately under the relevant item. Kota: Mirror finish 550mm x 550mm Size
Skirting Supply and installation of 8 to 10 mm thick machine-cut, polished Kota stone of uniform shade, size, and shape for skirting, flush with plaster or adjoining surfaces, and laid in any specified pattern on a properly levelled surface. The stone shall be fixed using a suitable stone fixing adhesive conforming to IS 15477, from an approved manufacturer, and jointed with a paper joint using grey cement slurry mixed with matching pigment to ensure seamless integration with the stone slabs. A 6 to 10 mm wide groove shall be provided between the skirting and plaster for a defined finish. The skirting stones shall be cut to the required length to align with the flooring joints and patterns, ensuring a consistent and uniform appearance. The shade of the skirting must match the flooring stone. The work shall include surface preparation, fixing, curing, rubbing, and polishing to achieve a smooth and precise finish, as per the approved design and to the satisfaction of the Engineer-in-Charge. The quoted rate shall include the supply of Kota stone (as per the approved sample), stone fixing adhesive, cement slurry, matching pigment, all necessary labour, and execution, complete in all respects.
Tile Cladding and Dado Work Supply and installation of vitrified tiles in various sizes (superior quality) with water absorption less than 0.08%, conforming to IS: 15622, from an approved brand and manufacturer. The tiles shall be of the specified color, shade, and finish (satin/polished, etc.) and installed in wall cladding, dado, risers of steps, and pillars, laid in any pattern over a properly levelled surface. The fixing shall be done using a suitable cement-based, high-polymer modified quick-set tile adhesive (water-based) conforming to IS: 15477, from an approved manufacturer. Tiles shall be jointed either with or without grooves using grey cement slurry mixed with matching pigment. A 6 to 10 mm wide groove shall be provided between the wall tiles and plaster edge for a defined finish. The dado tile layout shall align with the flooring pattern, ensuring a seamless transition and uniform appearance. The scope of work includes surface preparation, edge treatment, rubbing, curing, finishing, cleaning, protection, scaffolding, and handling of wastage to achieve a high-quality finish as per approved design and to the satisfaction of the Engineer-in-Charge. The quoted rate shall include the supply of vitrified tiles (as per the approved sample), tile adhesive, cement slurry, matching pigment, all labour, and execution, complete in all respects. However, filling of joints with epoxy grout shall be measured and paid separately under the relevant tender item. Tile Specification: a) Full-body homogeneous vitrified tiles of size 600 x 600 mm with a minimum thickness of 9 mm. The basic rate for tile is Rs. 650/sqm.
Epoxy Grouting of Tile/Stone Joints Providing and applying epoxy grout of approved make and shade for filling the joints of flooring, wall tiles, or stonework, with a joint width of up to 5 mm in total thickness. The work shall include the provision of PVC spacers, proper filling and grouting of joints, protection of tiles/stones, application of masking tape (Abro tape) as required, and final finishing to achieve a seamless appearance, as per the directions of the Engineer-in-Charge.
Sandwich Platform (Pantry) Providing and fixing 18 mm thick full body slab/granite for pantry (dry) platform as per approved size, shade, colour, and texture. Fullbody tile shall be fixed over a 20 mm thick granite base. The scope also includes providing and fixing facia and drops up to 50 mm width using epoxy resin-based adhesive, with proper alignment, finishing, and cleaning as per approved design and direction of the Engineer-in-Charge. All exposed edges shall be machine moulded and polished to match fullbody slab/granite finish. All work to be executed at all floors and levels, in strict accordance with approved drawings and specifications. The basic rate for Full body slab is Rs. 650/sqm.
FALSE CEILING Gypsum board ceiling Supply and installation of a false ceiling at all heights, incorporating a robust framework constructed from specialized sections, power-pressed from M.S. sheets, and galvanized with a zinc coating of 120 gms/sqm (both sides inclusive) as per IS: 277 standards. The framework shall consist of angle cleats measuring 25 mm in width and 1.6 mm in thickness, with flanges of 27 mm and 37 mm, spaced at 1200 mm centre-to-centre. One flange shall be securely fixed to the ceiling using dash fasteners (12.5 mm dia x 50 mm long) with 6 mm dia bolts, while the other flange shall be attached to angle hangers of 25x10x0.50 mm of the required length, using appropriate nuts and bolts. The other end of the angle hanger shall be connected to intermediate G.I. channels measuring 45x15x0.9 mm, running at 1200 mm centre-to-centre. The ceiling section shall comprise 0.5 mm thick bottom wedges of 80 mm width with tapered flanges of 26 mm each, having 10.5 mm lips, spaced at 450 mm centre-to-centre. These sections shall be fixed perpendicularly to the G.I. intermediate channels using connecting clips fabricated from 2.64 mm dia x 230 mm long G.I. wire at every junction. The perimeter channels shall be 0.5 mm thick, 27 mm in height, with flanges measuring 20 mm and 30 mm. These perimeter channels shall be firmly secured to walls or partitions with rawl plugs at 450 mm intervals, using 25 mm long drywall screws fixed at 230 mm intervals. Gypsum boards shall be affixed to the ceiling sections and perimeter channels using 3.5 x 25 mm drywall screws at 230 mm centre-to-centre. The jointing and finishing shall be executed to achieve a seamless flush finish for both tapered and square edges of the gypsum boards, utilizing the recommended jointing compound and jointing tape. The finishing process shall include three layers of jointing compound extending up to 150 mm on both sides of the joint, followed by two coats of primer compatible with the gypsum board, all in strict compliance with the manufacturer’s specifications. The scope shall also include provisions for making necessary openings for light fittings, air-conditioning grills, diffusers, and other cutouts, incorporating perimeter channel framing suitably secured in place. The entire installation shall be carried out as per approved drawings, project specifications, and the directions of the Engineer-in-Charge, excluding the cost of final painting. Gypsum board specification: 12.5 mm thick tapered edge gypsum moisture resistant board
Carefully dismantle and remove all indoor & outdoor existing old VRV AC System, ensuring proper segregation and shifting of materials to outside of the campus.
Vendor to quote buyback of existing old VRV system including job work.
Design, supply, installation, testing and commissioning of VRV system as per suggested layout. Consider 24°C require room temp. for all area at peck summmer season, 1-year defect liability period. VRV Indoor Unit: 5-nos 1-way caset unit & 1-nos ductable unit, VRV Outdoor Unit: 2-nos All work shall be executed in accordance with approved shop drawings, technical specifications, and site conditions, ensuring high-quality workmanship, durability, and aesthetic consistency. Note: A site visit is required before participation.
Comprehensive Annual Maintenance Contract (CAMC) of VRV ayatem 3-years
ALUMINIUM GLASS PARTITIONS
Fix Partition - DW1 (Cabin,Meeting Lounge), Dw2(Board Room),W1 (Board Room) Supply and installation of demountable partition system (Dormakaba ALTERRA or equivalent), designed for minimal-frame room-dividing applications, shall be executed as per approved architectural drawings and specifications. The system shall comprise double-glazed, mullion-free toughened DGU glass panels fixed in ALT 100DG aluminium profiles of size 100 mm x 30 mm, finished in natural anodized, black, or other approved finishes. Profiles shall feature concealed sealing with no visible gaskets or seals, achieving an acoustic performance rating of 42–50 dB, supported by a third-party acoustic test certificate. Glass panels shall be fixed using the proprietary stability GRIPPER clamp to ensure system rigidity. Vertical glass-to-glass joints shall utilize intermediate slim junction profiles with no visible clip lines, providing a clean, seamless appearance. Glass panels shall be offset-mounted towards the outer edge, reducing the visible aluminium frame on one side. An optional bottom seal pair profile shall be provided for additional acoustic performance where required. Glass thickness shall be 10 mm + 12 mm (DGU). Stick-on profiles of size 25 x 2 mm and 25 x 11.5 mm shall be used as per design requirements. All aluminium profiles shall have a minimum thickness of 1.5 mm with anodizing of 20 microns. All work shall comply with the following standards: 1 Structural stability testing in accordance with BS 5234: Part 2:1992 and EN 1991-1-1:2002 2 Acoustic performance testing in accordance with DIN EN ISO 10140-2 and ASTM E-90 3 Aluminium profiles manufactured and tested in accordance with EN 573-3, EN 755-2, and DIN EN 12020 T2 with dimensional tolerances in line with DIN ISO 2768-1 Class C 4 Toughened glass shall comply with BS 6262 5 Environmental Product Declaration (EPD) as per ISO 14025 and EN 15804 6 Health Product Declarations (HPD) with Unique Identifiers 22451 and 22452, classified under 09 84 00 Acoustic Room Components Installation shall include all necessary profiles, clamps, fixings, accessories, and site adjustments, ensuring proper alignment, stability, and finish to the satisfaction of the Architect and Engineer-in-Charge. The contractor shall provide a 12-month guarantee after the defects liability period, ensuring stability, water tightness, and the overall performance of the installed system.
Single Stile (Double Glazed) Door Supply and installation of aluminium double-glazed door (single leaf), comprising 6mm toughened safety glass + 8mm air gap + 6mm toughened safety glass, set in aluminium stiles of 100 x 45 mm with or without rebated door frame system, complete on all sides as per approved drawings and specifications. Door hardware to include: 1 5" x 3" x 3 mm flush hinges with screws, black PVD finish. 2 NSL 100 narrow stile sash lock with 35 mm backset, 72 mm centre-to-centre (CTC), and 20 mm square forend, supplied with strike plate, in matte black finish. 3 NLH 101 lever handle with narrow stile roses and escutcheons, 8 mm spindle with suitable fixing screws. 4 3525 Euro profile cylinder with one side key operation and one side knob, 70 mm length, supplied with three keys. 5 TS 70 EN 3–4 rack and pinion door closer with slide channel and hold-open function. 6 IS8010si-0920CA (UL-rated) automatic concealed door bottom seal. The aluminium profiles shall be in matt natural anodized, black anodized, or approved anodized finish. All profiles shall be of minimum 1.5 mm thickness with 20-micron anodizing. All necessary clips, seals, and fixing accessories shall be provided by the profile manufacturer. The maximum door height shall be 2790 mm, and maximum door weight 100 kg. Installation shall be completed in alignment and finish as per the approved design and to the satisfaction of the Architect and Engineer-in-Charge.
900 mm X 2790 mm (Cabin, Meeting Lounge)
1000 mm X 2790 mm (Board Room)
Single Stile (Single Glazed) Door Supply and installation of aluminium single-glazed door (single leaf), comprising 12mm clear toughened glass, set in 100 x 45 mm aluminium stiles with or without a rebated door frame system, complete on all sides as per approved drawings and specifications. Door hardware to include: 1 5" x 3" x 3 mm flush hinges with screws, black PVD finish. 2 D-type offset handle (450 x 25 mm), back-to-back fixing with suitable accessories. 3 TS 70 EN 3–4 rack and pinion door closer with slide channel and hold-open function. 4 IS8010si-1220CA (UL-rated) automatic concealed door bottom seal. The aluminium profiles shall be in matt natural anodized, black anodized, or approved anodized finish. All profiles shall be of minimum 1.5 mm thickness with 20-micron anodizing. All necessary clips, seals, and fixing accessories shall be provided by the profile manufacturer. The maximum door height shall be 2790 mm, and maximum door weight 100 kg. Installation shall be completed in alignment and finish as per the approved design and to the satisfaction of the Architect and Engineer-in-Charge.
1000 mm X 2790 mm (Pantry, Printing station)
1175 mm X 2790 mm (Passage to store room)
Aluminium Sliding Door Mechanism - (one sliding & One Fix) Supply and installation an automatic sliding door system with 12 mm thick toughened glass using Dorma ES250 Pro operator or approved equivalent. The system shall be suitable for clear passage dimensions up to 2000 mm width x 2800 mm height, with load capacity of 2 x 85 kg for double sliding or 1 x 100 kg for single sliding configurations. The system shall include: 1)Operator profiles with all necessary mechanical and electrical components 2) Floor guide for glass door 3)Nemo Motion + Nemo Dual (Safety & Motion) sensor combo pack 4)Bistable locking device 5)ECW radar 6)Five-position program switch with knob 7)Required connecting cables for program switch 8)Flap seal and softness seal for proper closing The glass shall be double-glazed (DGU) consisting of 6 mm toughened glass + 8 mm air gap + 6 mm toughened glass. Installation to be carried out as per approved drawings and manufacturer specifications, ensuring smooth, safe operation and alignment, to the satisfaction of the Architect and Engineer-in-Charge.
Providing and installing a Face Recognition Attendance System (Mantra Bionic FP6 or equivalent), licensed perpetually, with unlimited user support for scalability. The system shall feature real-time facial recognition, preventing unauthorized access through proxy images and ensuring seamless integration with existing IT infrastructure. The facial recognition device shall be a tablet with a minimum 7-inch display (1280x800 resolution), 2GB RAM, and 16GB internal storage, ensuring high-quality image capture and efficient processing. The device shall include a 1-year warranty. Installation shall comply with industry best practices, ensuring secure placement, proper configuration, and policy compliance. The system shall be delivered with user manuals, integration guidelines, and warranty documentation.
PAINT / TEXTURE WORK General Notes: 1)All adhesives, sealants, and paints shall be water-based, lead-free, and low VOC (Volatile Organic Compound content less than 50 gm/ltr). 2)Paint application shall be carried out only after thorough surface cleaning, ensuring it is free from mortar droppings, dust, and foreign matter. 3)Surface shall be smoothened and levelled using white cement-based putty (minimum two coats), with each coat properly sandpapered before the next application. 4)A priming coat of alkali-resistant cement primer (water- or solvent-based) shall be applied over the prepared surface. 5)Paint shall be applied in a minimum of two coats or as required until a uniform, even finish is achieved. 6)Application shall be carried out using a brush, roller, or spray, as per site conditions. 7)If additional coats are necessary to achieve the desired finish, they shall be applied without any extra cost. 8)The contractor shall prepare a minimum of three shade samples as suggested by the Engineer-in-Charge for approval before proceeding. 9)Work shall be executed at all floors, all heights, and all levels, using any necessary means of scaffolding, with the cost included in the rate. 10)The contractor shall furnish warranty documents, wherever applicable.
Providing and applying emulsion paint (Asian paints, Berger paints or equivalent) over newly plastered dry interior surfaces of walls, ceilings, and other elements at all heights, all levels, and all surfaces to achieve an even shade. Work includes: 1. Surface preparation by removing foreign matter and ensuring an undulation-free finish. 2. Application of two coats of white cement-based putty, each followed by thorough sanding. 3. Priming coat with alkali-resistant cement primer. 4. Final paint application in at least two coats or more, as required, until an even, uniform finish is obtained. 5. Crack filling, surface brushing, and cleaning as necessary The rate shall be inclusive of all materials, labour, tools, surface preparation, scaffolding, and finishing as per approved specifications and as directed by the Engineer-in-Charge.
Providing and applying lime based coating (Asian paints, Limo Coat or equivalent) over newly plastered dry interior surfaces of walls, ceilings, and other elements at all heights, all levels, and all surfaces to achieve an even shade. Work includes: 1. Surface preparation by removing foreign matter and ensuring an undulation-free finish. 2. Application of two coats of white cement-based putty, each followed by thorough sanding. 3. Priming coat with alkali-resistant cement primer. 4. Final paint application in at least two coats or more, as required, until an even, uniform finish is obtained. 5. Crack filling, surface brushing, and cleaning as necessary. The rate shall be inclusive of all materials, labour, tools, surface preparation, scaffolding, and finishing as per approved specifications and as directed by the Engineer-in-Charge.
Acoustic panelling with rock wool infill (100mm wide) shall be provided and installed as per the approved concept design and drawings. The partition shall be executed as follows: A plywood framework using IS 710 BWP-grade plywood shall be installed along the periphery and internal framing as per required dimensions, ensuring proper alignment. The framework shall be securely fixed to the existing concrete wall using SS 304 screws, fasteners, and adhesives. All plywood surfaces shall be adequately protected. The framework cavity shall be filled with 75mm thick rock wool insulation and covered with fabric of approved make, shade, and pattern. The fabric panels shall be fixed onto the plywood frame using screws, fasteners, and adhesives, ensuring a seamless finish with a 5mm wide, 10mm deep groove between panels. No plywood or wooden surface shall be visible in the acoustic panelling. The rate shall be inclusive of all materials, including wooden framing, plywood, rock wool, fabric, beading, fasteners, screws, adhesives, PU polish, scaffolding, sampling, mock-up, rectifications, and cleaning of adjacent surfaces. Work shall be carried out at all floors and levels as directed by the Engineer-in-Charge. The contractor shall prepare shop drawings and obtain approval from the Architect and Engineer-in-Charge before execution. Payment shall be based on the total out-to-out elevation area of the partition, including the outer frame (one side only). The basic rate for fabric is Rs. 1500/sqm.
Acoustic Panelling in Board Room (as per DRG NO: IIM_I_601)
Acoustic Wall Art (as per DRG NO: IIM_I_673)
Electrical Box Make good of existing electrical wooden cupboard by changing veneer/laminate
Workstations/desks/tables/side storages (Featherlite or equivalent) shall be supplied and installed as per the specified dimensions, using high-quality particle board with a laminate finish and PVC lipping on all exposed edges. CRS legs shall be provided as per the specifications and reference images in the annexure. The table components, including the tabletop, pedestal, desk organizer, box work, drawers, modesty panel, divider panels, and footrest, shall be made from high-quality particle board with an approved laminate finish on both sides and PVC lipping on all edges. Vertical supporting legs shall be securely fixed with a base plate, and all metal surfaces shall have a 50-micron polyester powder coating in an approved shade. Additional metal support shall be incorporated as needed to ensure structural stability. The workstation shall incorporate necessary cable management systems to ensure concealed wiring. Additionally, a pop-up box with sockets and switches shall be integrated, comprising approximately four plug points with individual switches, two USB ports, and two internet points for seamless connectivity to multimedia, one C - type point, either on the tabletop or mounted below. All internal and external surfaces shall be finished with laminates of an approved make and shade. Wooden and veneer surfaces shall be treated with an exterior-grade water-based PU polish or an equivalent finish of an approved make and shade. Hardware components such as hinges, handles (including profile handles), locks, magnetic catchers or push-to-open systems, and drawer channels shall be sourced from approved manufacturers. A prototype or mock-up of the workstation shall be prepared and submitted for approval by the Architect and Client before proceeding with full-scale execution.
T - 01 - Board room table - approx. size (L x W x H) 4650 x 1200 x 750 (mm) Supply and installation of storage unit as per approved make and provided intent image in annexure 02 or equivalent.
T - 04 - Cabin executive table - approx. size (L x W x H) 1500 x 750 x 750 (mm) Supply and installation of storage unit as per approved make and provided intent image in annexure 02 or equivalent.
ST-02 - Storage Unit Approximate size (L X W X H) - 1050 x 450 x 700 (mm) Supply and installation of storage unit as per approved make and provided intent image in annexure 02 or equivalent.
CT-01 - Side / Centre Table Approximate size (D X H) - 600 x 450 (mm) Supply and installation of table as per approved make and provided intent image in annexure 02 or equivalent.
Custom Workstation + Reception Table (as per DRG NO: IIM_I_621 & 622) supply and installation of the work desk cum reception table shall be constructed using plywood with a veneer finish and solid wood lipping on all exposed plywood edges, as per the approved drawing. The side storage unit shall include multiple drawers made of plywood and veneer, designed as per the approved pattern and design. The box structure shall be entirely made of plywood, with drawers constructed from plywood on all sides, while the drawer base shall have a laminate finish. The furniture shall incorporate cable management to conceal all cables from the floor to the desks. A privacy screen shall be made from plywood and veneer, and the design shall include connectivity provisions for AV, internet, laptop power, additional power outlets, and a microphone at the tabletop or base. The workstation shall incorporate necessary cable management systems to ensure concealed wiring. Additionally, a pop-up box with sockets and switches shall be integrated, comprising approximately four plug points with individual switches, two USB ports, and two internet points for seamless connectivity to multimedia, AV, internet, laptop power, extra power, and printers, either on the tabletop or mounted below. All wooden joinery and detailing shall conform to the approved design pattern or sample. All wood and veneer surfaces shall be finished with exterior-grade water-based PU polish of the approved make and shade. Hardware of an approved brand and finish shall be provided as required. The furniture shall be fabricated in alignment with the intent image, drawing, and specifications, ensuring the satisfaction of the Architect and Engineer in Charge. Install PVC pipe/conduit of appropriate diameter inside privacy screen for running cable for all workstations.
T - 02 - Reception desk - approx. size (L x W x H) 1810 x 600 x 750 (mm)
T - 03 - Workstation table - approx. size (L x W x H) 1500 x 600 x 750 (mm)
P - 01 Wooden Partition Approximate size (L X W X H) - 7500 x 75 x 1050 (mm)
ST - 01 - Storage Unit Approximate size (L X W X H) - 1800 x 450 x 700 (mm)
Corner table in Meeting Lounge (as per DRG NO: IIM_I_643) The supply and installation of the Corner Table shall be constructed using plywood with a veneer finish, featuring solid wood lipping on all exposed plywood edges, as per the approved drawing. All external surfaces shall have a veneer finish, while internal surfaces shall have a laminate finish of the specified make and shade. All wooden joinery and detailing shall conform to the approved design pattern or sample. The wood and veneer surfaces shall be finished with exterior-grade water-based PU polish of the approved make and shade. Hardware of an approved brand and finish shall be provided as required. The furniture shall be fabricated in accordance with the intent image, drawing, and specifications, ensuring the satisfaction of the Architect and Engineer in Charge. The Corner Table shall incorporate a cable management system to ensure concealed wiring. Additionally, a pop-up box with sockets and switches shall be integrated, featuring approximately four plug points with individual switches, two USB ports, and two internet points, allowing seamless connectivity for multimedia, AV, internet, laptop power, extra power, and printers. The pop-up box may be placed either on the tabletop or mounted below, as per the approved design.
Custom Media Console in Board Room + Lounge Room (as per DRG NO: IIM_I_605) Supply and installation of the Media Console shall be constructed using plywood with a veneer finish, featuring solid wood lipping on all exposed plywood edges, as per the approved drawing. Both internal and external surfaces shall have a veneer finish of the specified make and shade. All wooden joinery and detailing shall conform to the approved design pattern or sample. All wood and veneer surfaces shall be finished with exterior-grade water-based PU polish of the approved make and shade. Hardware of an approved brand and finish shall be provided as required. The furniture shall be fabricated in accordance with the intent image, drawing, and specifications, ensuring the satisfaction of the Architect and Engineer in Charge.
Custom Pantry Storage (Above + Below Counter) (as per DRG NO: IIM_I_285) Supply and installation of the Pantry Storage shall be constructed using plywood with a laminate finish, featuring 1mm PVC lipping on all exposed plywood edges, as per the approved drawing. Both internal and external surfaces shall have a laminate finish of the specified make and shade. All wooden joinery and detailing shall conform to the approved design pattern or sample. Hardware of an approved brand and finish shall be installed as required. The furniture shall be fabricated in alignment with the intent image, drawing, and specifications, ensuring the satisfaction of the Architect and Engineer in Charge
Overhead Storage
Undercounter Storage
Custom Printing Station Storage (Above + Below Counter) (as per DRG NO: IIM_I_295) Supply and installation of the Stationary Storage shall be constructed using plywood with a laminate finish, featuring 1mm PVC lipping on all exposed plywood edges, as per the approved drawing. Both internal and external surfaces shall have a laminate finish of the specified make and shade. All wooden joinery and detailing shall conform to the approved design pattern or sample. Hardware of an approved brand and finish shall be installed as required. The furniture shall be fabricated in alignment with the intent image, drawing, and specifications, ensuring the satisfaction of the Architect and Engineer in Charge.
Corten Steel Panel (as per DRG NO: IIM_I_271)
Supply and installation of metal panel from 2mm thk corten steel sheet (installed over plywood panel)as per concept drawing and intent image. All panels shall be cut to the required size and shape using precision techniques such as: Water jet cutting, Laser cutting, CNC machining. The panel shall be fabricated in alignment with the intent image, drawing, and specifications, ensuring the satisfaction of the Architect and Engineer in Charge.
Supply and installation of wooden panelling
Greenwall / Landscape (as per DRG NO: IIM_I_674) Supply, fabrication, and installation of a custom planter using 202 stainless steel (SS) sheet with an 8x8 mm 202 SS frame, as per the approved concept drawing and design intent. All SS bars and sheets shall be precision-cut, welded, and finished to ensure structural stability, smooth surfaces, and strong joints. Fabrication shall comply with the approved design, dimensions, and specifications. The planter shall be fabricated in alignment with the intent image, drawing, and specifications, ensuring the satisfaction of the Architect and Engineer in Charge.
Logo as per drawing.
ELECTRICALS WORKS
POWER DISTRIBUTION BOARDS Supply, installation, testing & commissioning of Three Phase/ Single Phase, Double Door, readymade type Distribution Boards IP 43 grade, with PPI kit and Flexy Distribution board & SPN as per drawings & specifications. The unit rate shall include supply & fixing on wall / column or concealed in wall, checking of wiring, connection and operation of MCBs and supply of necessary hardware.
FLEXI DB 3 ROW-14 MODULE-FLEXI DB Incoming : 63A FP MCB Outgoing : 6 # 40A FP MCB
DB 12 WAY TPN DB Incoming : 40A FP MCB Outgoing : 3 # 40A DP ELCB (30mA) & 30 # 6/10/16/20A SP MCB
63A FP, MCB with Enclouser (10kA)
40A FP, MCB with Enclosure (10kA)
63A FP, EL+MCB (100mA) with Outdoor Type Enclosure
40A FP, EL+MCB (100mA) with Outdoor Type Enclosure
SITC of Type/Class-I+II, FP, SPD for Distribution Boards with necessary MCB protection.
SITC of Type/Class-II, FP, SPD for Distribution Boards with necessary MCB protection.
MEDIUM VOLTAGE CABLES Aluminium Armoured Cable: Voltage: 1100V Conductor:Stranded Class 2 Aluminium Conductor Insulation: XLPE as per IS 7098(Pt-1)/88, Latest Inner Sheath: Wrapping of Tape inner sheath Armour: Galvanised Steel Flat strip armour Outer Sheath: Extruded FR-LSH PVC Type 'ST2' as per IS:5831 Standard:-IS 7098 Part I/88, IS 8130/2013, IS 5831/84, IS 3975/1999 etc. with latest up to date amendments Copper Armoured Cable: Voltage: 1100V Conductor:Stranded Class 2 Copper Conductor Insulation: XLPE as per IS 7098(Pt-1)/88, Latest Inner Sheath: Extruded PVC Type 'ST2' as per IS:5831/84 Armour: Galvanised Steel Flat strip armour Outer Sheath: Extruded FR-LSH PVC Type 'ST2' as per IS:5831/84 Standard:Generally as per IS 7098 Part I/88, IS 8130/2013, IS 5831/84, IS 3975/1999 etc. with latest up to date amendments Copper Flexible Cable: Voltage: 1100V Conductor:Plain annealed high conductivity Flexible copper conductor as per Class 5 of IS 8130/2013 latest Insulation: PVC Type 'D' Sheath:Extruded "FR-LSH" PVC Type 'ST3' as per IS:5831/841.4 Standard: As per IS 8130/2013,IS 694/2010, etc. with latest up to date amendments Supply, Laying, testing & Commissioning of XLPE insulated medium voltage Armoured / Unarmoured Copper/Aluminium cables as per the specifications, drawings & instruction of Engineer-in-charge and as per the instruction of the manufacturer. The cable shall be laid with saddaling in open manner on wall/slab from Main Panel to Distribution board / distribution board to distribution board. The unit rate shall include supply & laying of cables,Transportation from site store to place of installation,unpacking the drum and return of drum to the site store.
4C X 16 sq.mm Copper armoured cable
4C X 10 sq.mm Copper armoured cable
4C x 6 sq.mm Copper armoured cable
3C X 10 sq.mm Copper armoured cable
3C X 6 sq.mm Copper armoured cable
4C x 6 sq.mm Copper flexible cable
4C x 4 sq.mm Copper flexible cable
3C x 6 sq.mm Copper flexible cable
3C x 4 sq.mm Copper flexible cable
3C x 2.5 sq.mm Copper flexible cable
CABLE CONNECTIONS & TERMINATIONS Supply, Connections & Termination of Medium voltage XLPE insulated aluminium/copper cables as per the specification & instruction of Engineer-in-charge.The unit rate shall include connection of adequate size DOUBLE compression type brass cable glands, Rubber cable boots and lungs including cutting/stripping of cable insulation, fixing of cable glands,crimping the lugs, connection of cable armour with earth bar,necessary tools,hardware,PVC insulated tape and all other material required.
4C X 16 sq.mm Copper armoured cable
4C X 10 sq.mm Copper armoured cable
4C x 6 sq.mm Copper armoured cable
3C X 10 sq.mm Copper armoured cable
3C X 6 sq.mm Copper armoured cable
4C x 6 sq.mm Copper flexible cable
4C x 4 sq.mm Copper flexible cable
3C x 6 sq.mm Copper flexible cable
3C x 4 sq.mm Copper flexible cable
3C x 2.5 sq.mm Copper flexible cable
CABLE TRAY Supply, Fabrication & installation of readymade Perforated type G.I. cable tray (HDGI) as per drawing, specification & instruction of Engineer-in-charge including all materials & hardware. Thickness - 2mm., Height -50 mm, Length - 2.5 mtr. Colour shed to be approved from Client / Architect / Consultants prior to order. all accessories like bends / tee / coupler etc.. will be measured in RMT. Only Cable tray supports shall be considered in fabrication item separately
150 mm wide cable tray
200 mm wide cable tray
300 mm wide cable tray
150 mm wide cable tray with cover
200 mm wide cable tray with cover
300 mm wide cable tray with cover
Support Fabrication for Cable tray
Supply & Installation of 2 Nos. 6mm GI threaded rod with slotted channel at each 1 meter distance as per drawing, specification and as per engineer-in-charge including all accessories, anchor fastener, drilling welding, nut bolts and leveling.
PVC PIPE LAYING & FLOOR JUNCTION BOX
PVC PIPE LAYING Supply & laying of conduit / raceway open or concealed manner in Slab / floor / wall as per drawings, specification, instruction of Engineer-in-charge and as per the instruction of the manufacturer. Rate of PVC pipe / Raceway, flexible pipe, junction box, bend and all other accessories to be considered in unit rate.
65 mm dia. PVC conduit
50 mm dia. PVC conduit
40 mm dia. PVC conduit
32 mm dia. PVC conduit
25 mm dia. PVC conduit
100X50MM UPVC wall Raceway white (Similar to NCT 1050)
50X50MM UPVC wall Raceway white (Similar to NCT 5050)
FLOOR JUNCTION BOX Supply & Installation of ready made type adjustable 65-90MM height metal floor junction box as per drawings, specification, instruction of Engineer-in-charge and as per the instruction of the manufacturer.
150MM x 150MM x 65 – 90MM
225MM x 225MM x 65 – 90MM
300MM x 300MM x 65 – 90MM
INTERNAL WIRING
Supply, installation, testing & commissioning of Point wiring as per Drawing, Specification & as per the instruction of engineer-in-charge. The unit rate for Light / Fan / plug point shall include supply & Laying of 25 mm dia MMS PVC conduit & accessories in slab / flooring / false ceiling, 2 # 2.5 SQ.MM & 1 # 1.5 SQ.MM copper flexible HFFR wires as a mains wiring from DB to Switch board and 3 # 1.0 sq.mm Copper flexible HFFR wires as an off Wiring from Switch board to first light point (PRIMARY) in 25mm Dia. PVC conduit & further each looped light point shall be considered as SECONDARY point in 25mm dia. PVC conduits. (The point shall be measured from distribution board and no extra payment on account of circuit mains is payable)
One light point control by one 6A Switch. (Primary Light Point)
Secondary Light / Exhaust point
One Ceiling fan controlled by 1 switch & electronic regulator
Wall Fan / Exhaust fan controlled by one switch.
6A plug point controlled by one switch on SB
Two way light point control by Two way switch
One light point control by one 6A weather proof switch PRIMARY
POWER PLUG POINT WIRING Supply, installation, testing & commissioning of Plug Point wiring as per Drawing, Specification & as per the instruction of engineer-in-charge. The unit rate for plug point shall include supply & Laying of 25 mm dia MMS PVC conduit & accessories in slab / flooring / false ceiling with 2 # 2.5 SQ.MM. & 1 # 1.5 SQ.MM. copper flexible HFFR wires as a mains wiring from DB to Plug Point in 25mm Dia. PVC conduit.
6A plug point controlled by one switch primary
6A plug point controlled by one switch secondary
6/16A plug point controlled by one switch primary
6/16A plug point controlled by one switch secondary
POWER PLUG POINT WIRING Supply, installation, testing & commissioning of Plug Point wiring as per Drawing, Specification & as per the instruction of engineer-in-charge. The unit rate for plug point shall include supply & Laying of 25 mm dia MMS PVC conduit & accessories in slab / flooring / false ceiling with 2 # 4.0 SQ.MM. & 1 # 2.5 SQ.MM. copper flexible HFFR wires as a mains wiring from DB to Plug Point in 25mm Dia. PVC conduit.
16A plug point controlled by one 16A switch primary
16A plug point controlled by one 16A switch secondary
SITC of Weather Proof 6/16A Plug Point with 16A Switch without mains wiring
COMPUTER / TV POWER POINT WIRING SITC of Computer Power OR TV Power point wiring in 25mm dia. PVC conduit as per drawing, specification and as per the instruction of Engineer-in-charge.Wire size for computer power point shall be 2#2.5 sq.mm and 1#1.5 sq.mm copper flexible HFFR wires in 25mm dia. Pvc conduit. The unit rate shall comprise of mains wiring from UPS distribution board to first Computer Point (PRIMARY) & further each looped Computer point shall be considered as SECONDARY. Rate for switch, box and plate should also be included in unit rate including mains.
Primary Computer / TV Point (4#6A plug point & 2#6A switch)
Secondary Computer / TV Point (4#6A plug point & 2#6A switch)
Primary Computer / TV Point (3#6A plug point & 1#6A switch)
Secondary Computer / TV Point (3#6A plug point & 1#6A switch)
3000mA/15 Watts - Type-A - 1 Module - USB Charger On Board
Power Delivery - 20 Watts - Type-C - 1 Module - USB Charger On Board
INDOOR AC UNIT POINT WIRING
Wire size for AC indoor unit point 3 # 1.5 Sq.mm copper Flexible HFFR wires from MCB to AC point in 25 mm dia. PVC conduit in concealed manner on wall / slab or in floor. Unit rate shall comprise of mains wiring, off wiring & PVC pipes and accessories. Rate for Supply of switch, box, plates & socket should not be included in unit rate.
Wire size for AC indoor unit point 2 # 2.5 Sq.mm & 1 # 1.5 Sq.mm copper Flexible HFFR wires from MCBDB to AC point in 25 mm dia. PVC conduit in concealed manner on wall / slab or in floor. Unit rate shall comprise of mains wiring, off wiring & PVC pipes and accessories. Rate for Supply of switch, box, plates & socket should not be included in unit rate.
Wire size for AC indoor unit point 2 # 4.0 Sq.mm & 1 # 2.5 Sq.mm copper Flexible HFFR wires from MCBDB to AC point in 25 mm dia. PVC conduit in concealed manner on wall / slab or in floor. Unit rate shall comprise of mains wiring, off wiring & PVC pipes and accessories. Rate for Supply of switch, box, plates & socket should not be included in unit rate.
MAINS WIRING (only if required)
Supply, Laying & connection of 4 # 4.0 sq.mm & 2 # 2.5 sq.mm copper flexible HFFR wires from DB/Panel to switch board / Power Point in 25mm Dia. MMS PVC conduit in wall / slab / floor. The unit rate shall include rate of Supply, Laying & connection of pipes & wires.
Supply, Laying & connection of 4 # 6.0 sq.mm & 2 # 4.0 sq.mm copper flexible HFFR wires from DB/Panel to switch board / Power Point in 32mm Dia. MMS PVC conduit in wall / slab / floor. The unit rate shall include rate of Supply, Laying & connection of pipes & wires.
Supply, Laying & connection of 4 # 10 sq.mm & 2 # 6.0 sq.mm copper flexible HFFR wires from DB/Panel to switch board / Power Point in 40mm Dia. MMS PVC conduit in wall / slab / floor. The unit rate shall include rate of Supply, Laying & connection of pipes & wires.
Supply, Laying & connection of 3 # 1.5 sq.mm copper flexible HFFR wires from DB/Panel to switch board / Power Point in 25mm Dia. MMS PVC conduit in wall / slab / floor. The unit rate shall include rate of Supply, Laying & connection of pipes & wires.
Supply, Laying & connection of 2 # 2.5 sq.mm & 1 # 1.5 sq.mm copper flexible HFFR wires from DB/Panel to switch board / Power Point in 25mm Dia. MMS PVC conduit in wall / slab / floor. The unit rate shall include rate of Supply, Laying & connection of pipes & wires.
Supply, Laying & connection of 2 # 4.0 sq.mm & 1 # 2.5 sq.mm copper flexible HFFR wires from DB/Panel to switch board / Power Point in 25mm Dia. MMS PVC conduit in wall / slab / floor. The unit rate shall include rate of Supply, Laying & connection of pipes & wires.
Supply, Laying & connection of 2 # 6.0 sq.mm & 1 # 4.0 sq.mm copper flexible HFFR wires from DB/Panel to switch board / Power Point in 25mm Dia. MMS PVC conduit in wall / slab / floor. The unit rate shall include rate of Supply, Laying & connection of pipes & wires.
LIGHT FIXTURE INSTALLATION Supply, Installation, testing & commissioning of Light fixture & ceiling Fan in False Ceiling or on wall or below slab, Exhaust fan as per Drawing & as per instruction of engineer-in-charge. Note: All technical details of fixture shall be as per LIGHTING ANNEXURE
Light Fixture Code – L1 – COB Downlight
Light Fixture Code – L2 – COB Downlight
Light Fixture Code – L3 – Concealed Profile Light
Light Fixture Code – L4 – Hanging Profile Light
Light Fixture Code – L5 – Decorative Profile Light
Light Fixture Code – L6 – Panel Down Light
Light Fixture Code – L7 – Panel Light
Light Fixture Code – LC – LED Strip Light
1050 MM. SWEEP CEILING FAN
900 MM. SWEEP CEILING FAN
Wall Fan
300 MM EXHAUST FAN
SITC of fan rod of 450mm length (10 gauge)
SITC of fan rod of 600mm length (10 gauge)
SITC of fan rod of 750mm length (10 gauge)
SITC of Anchor Fastner for fan
SITC of Lighting ON/OFF sensors as per drawing, specification and as per Engineer-in-charge. K4015 - similar to MK make
SITC of Lighting ON/OFF sensors as per drawing, specification and as per Engineer-in-charge. K4016 - similar to MK make
MAINTENANCE FREE EARTHING Supply, installation, testing & commissioning of Maintenance Free earthing as per specification, drawing and as per the instruction of Engineer-in-charge. The unit rate shall include Excavation & backfilling, resistance lowering grounding minerals to increase the overall conductive surface area in order to lower the ohmic value and also to minimize the corrosion process, highly conductive Copper & 300mm x 300mm READY MADE FRP chamber with cover or as per OEM. Contractor to take earth resistance testing reading and submit the earth testing report. Contractor has to mark earth pit number, resistance value and testing done & due date at each and every earthing. The earth electrode shall be made as per latest IS-62305. SITC of Earthing shall be done only by company technical team and as per company's technical requirements to achieve earth resistance less than 1 ohm. Neutral Earth voltage shall also be measured and shall be less than 2 volts. ABB - Furse make 17.2 mm Dia. x 3000 mm Long 254 Micron - Copper Bonded MS Rod manufactured as per IEC 62561-2 (part No. - RB335) with Conductive Concrete Encasing (made from Fursecem (Part No. CM025) & Portland Cement @ ratio of 3:1) with 80mm Dia. + ‘U’ bolt rod clamp (type GUV) (part No.-CR700) suitable for connecting the earth Strip - Precast Module OBO make of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 14.2 (BODY earthing) & 25 (Neutral Earthing) mm with copper coating thickness of 250 micron tested as per IEC 62561-2 & is provided with universal clamp made of SS to connect rod with flat conductor . Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested. The above arrangements shall be provided with Heavy duty earth chamber of 5000 kg load bearing capacity to ensure the safety of earthing system. CAPE make: UL Listed Copper bonded Solid Steel Rods are to be used as vertical electrode. These electrodes shall be made of high tensile low carbon steel rod, molecular bonded with 99.9% electrolytic copper with minimum coating thickness of 250 microns. 17.2mm (Body Earthing) & 25 mm (Neutral Earthing) dia copper bonded rod with minimum length of the earth rod shall be 3 meters which is a single rod should be as per IEC 62561-2. Universal clamp of required size should be made up of SS304. Earth enhancement compound of 25kg should be used made graphite and carbon should be of conductive concrete based mineral compound producing low resistance of an earth termination system. CAPE MAKE:- Material of the earthing enhancing compound shall be chemically inert to subsoil. It shall not pollute the environment. Earth rods Test reports for Marking, Dimension, Electrical resistance before and after salt mist test, tensile strength, bend test , adhesion test to be submitted The compound shall be tested and certified as per IEC 62561-7 and also fulfill Toxicity Characteristic Leaching Procedure (TCLP) requirements.Earth Chamber Should have an inner dimension of 250 mmX 250 mm X 250 mm made of PP Material. Flush Mounted, removable and lockable cover of the earth pit should be able to withstand 5KN.
Body earthing
Neutral earthing
Supply, Laying,connection & testing of earthing strips for connection equipments with earthing grid in readymade trenches/on Cable trays,on wall,buried in ground outside the building at a depth of 500 mm from Finished ground level including excavation and backfilling including all material and hardware required.
32 mm x 6 mm GI Earthing strip
25 mm x 6 mm GI Earthing strip
25 mm x 3 mm GI Earthing strip
8 gauge GI wire
10 gauge GI wire
32 mm x 6 mm Copper Earthing strip
25 mm x 6 mm Copper Earthing strip
25 mm x 3 mm Copper Earthing strip
8 gauge Copper wire
10 gauge Copper wire
2.5 Sq.mm Cu. Flexible HFFR Wire
ELV SYSTEM WIRING
PASSIVE NETWORK CMPONENTS
SITC of CAT6A UTP Ethernet Cable 4pair LSZH (Reel of 500 meter)
SITC of CAT6A UTP I/O Jack
SITC of Faceplate with backbox
SITC of 24 Port CAT6A Loaded Patch Panel
SITC of Factory-crimped 1 Meter patch cord CAT6A(Rack side)
SITC of Factory-crimped 2 Meter patch cord CAT6A (User side)
ABHISHEK INTERIORS (BID ID -3209302)
NEW CONCEPT (BID ID -3208475)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .