| Sl No | Description | Qty | Unit | Mark Matrix Security Solution L2 | HVAC WEATHER DESIGN L1 |
|---|---|---|---|---|---|
| 1.01SUPPLY PART | |||||
| 1.02DX (Direct Expansion) Type Air Conditioning Indoor units. | |||||
| 1.03Supply, Installation testing and commissioning of inverter type air cooled Air-conditioners each complete with scroll compressor,air cooled condensor, GSS casing, filters, cooling coils, fanmotors, insulated copper refrigerant piping as per drawing control wiring, refrigerant controls and accessories, including MICRO-PROCESSOR CONTROL with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipments requirements with Micro-processor control panel for each machine. | |||||
| 1.04 | 11 TR Ductable Indoor Unit | 2 | NOS | 6,40,000 ₹7.6 L | 4,26,000 ₹5.0 L |
| 1.05 | Supply,of Refrigerant piping (suction,Discharge) Hard Drawn Copper piping of suitable sizes, with copper elbows, tees,tubular Nitrile Insulation. Make:Totaline/Uniflow/Rajco/Mandev/Mexflow | 20 | RM | 45,000 ₹53,100 | 28,000 ₹33,040 |
| 1.06 | Supply of cabling between indoor and outdoor unit. (Power and Communication). Make : Havells, Finolex, RR, equivalent | 20 | RM | 13,000 ₹15,340 | 6,000 ₹7,080 |
| 1.07 | Supply of Auto-Change Over Relay with settable timer, suitable for alternate running both Ductable A/Cs periodically, with incoming feeder. | 1 | NOS | 39,500 ₹46,610 | 32,000 ₹37,760 |
| 1.08 | Supply of 25/32 mm dia. pvc pipe, Drain pipes using minimum 25mm dia and above, consider the machine size and grouping. This shall be insulated with 9mm thick nitrile rubber insulation, with necessary fittings like elbows, tees and reducers etc. | 20 | RM | 9,000 ₹10,620 | 5,000 ₹5,900 |
| 1.09Air Disribution Works | |||||
| 2.00 | Supply of 22 Gauge Ducting (0.8) of Galvanised Sheet Rectangular Ducting complete with all fittings such as reducers, Tee bends, take offs, suspension, Hi Tech supporting arrangements for plenum, complete as required for air-conditioning application | 10 | Sq.mtr | 12,500 ₹14,750 | 15,000 ₹17,700 |
Updated dates
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
15 Nov 2025, 2:00 pmClosed
AGM-UANDM
AGM-UANDM office COCHIN SHIPYARD LIMITED KOCHI,682015
AUGMENTATION OF AIR CONDITIONING CAPACITY AT QUAY 3 SUBSTATION.
2025_CSL_253556_1
UandM/EM1/QTN/02/25-26
Open Tender
Electrical Works
30 days
COCHIN SHIPYARD LIMITED KOCHI
As per the tender documents.
3 documents required · 3 mandatory
₹0
₹29,000
Yes
16 Dec 2025
28 Oct 2025
17 Nov 2025
28 Oct 2025
15 Nov 2025
28 Oct 2025
28 Oct 2025 - 15 Nov 2025
SUPPLY PART
DX (Direct Expansion) Type Air Conditioning Indoor units.
Supply, Installation testing and commissioning of inverter type air cooled Air-conditioners each complete with scroll compressor,air cooled condensor, GSS casing, filters, cooling coils, fanmotors, insulated copper refrigerant piping as per drawing control wiring, refrigerant controls and accessories, including MICRO-PROCESSOR CONTROL with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipments requirements with Micro-processor control panel for each machine.
11 TR Ductable Indoor Unit
Supply,of Refrigerant piping (suction,Discharge) Hard Drawn Copper piping of suitable sizes, with copper elbows, tees,tubular Nitrile Insulation. Make:Totaline/Uniflow/Rajco/Mandev/Mexflow
Supply of cabling between indoor and outdoor unit. (Power and Communication). Make : Havells, Finolex, RR, equivalent
Supply of Auto-Change Over Relay with settable timer, suitable for alternate running both Ductable A/Cs periodically, with incoming feeder.
Supply of 25/32 mm dia. pvc pipe, Drain pipes using minimum 25mm dia and above, consider the machine size and grouping. This shall be insulated with 9mm thick nitrile rubber insulation, with necessary fittings like elbows, tees and reducers etc.
Air Disribution Works
Supply of 22 Gauge Ducting (0.8) of Galvanised Sheet Rectangular Ducting complete with all fittings such as reducers, Tee bends, take offs, suspension, Hi Tech supporting arrangements for plenum, complete as required for air-conditioning application
Supply of 22 Gauge Ducting (0.8) (GI) Thermally insulated drain pan of GI or aluminium sheet,15 cm below unit with at least 5 cm more than size of the unit on all fours sides.Drain pan height shall be minimum 5 cm with drain outlet of 1 inch. The drain line shall be connected to unit drain with proper slope.
Air Oulets
Supplying powder coated extruded Aluminium Supply/Return air Grills
Supplying flexible duct Canvas connector for ductable unit connection to air ducts
Insulation Works
Thermal Insulation : Supplying of 9mm thick Class O nitrile rubber insulation with in-built lifetime anti microbial protection, with al. foil. Insulation density shall be 40-60 Kg/m3. Thermal conductivity to be 0.033 @ 0 deg C mean temperature and water vapour diffusion resistance should be 7000 without any external vapour barrier.
Drain PanThermal Insulation : Supply of 13mm thick Class O nitrile rubber insulation with in-built lifetime anti microbial protection,with al. foil. Insulation density shall be 40-60 Kg/m3. Thermal conductivity to be 0.033 @ 0 deg C mean temperature and water vapour diffusion resistance should be 7000 without any external vapour barrier
Acoustic Insulation : Supply, installation and testing of acoustic lining with 10 mm thick open cell nitrile foam on the inner side of ducting including providing, fixing and finishing the same as per specifications for ducts as required density of material shall be 140‐180 kg/m3.
Welding works for indoor support hanging
Outdoor Stand for 11.0 TR Inverter Ductable Unit
Room Insulation
Thermal Insulation : Supply of 13mm thick Class O nitrile rubber insulation with in-built lifetime anti microbial protection with al. foil. Insulation density shall be 40-60 Kg/m3. Thermal conductivity to be 0.033 @ 0 deg C mean temperature and water vapour diffusion resistance should be 7000 without any external vapour barrier. (Underdeck Insulation)
Thermal Insulation : Supply and fixing of 13mm thick Class O nitrile rubber insulation with in-built lifetime anti microbial protection with al. foil. Insulation density shall be 40-60 Kg/m3. Thermal conductivity to be 0.033 @ 0 deg C mean temperature and water vapour diffusion resistance should be 7000 without any external vapour barrier. (Wall Insulation)
Installation Part
DX (Direct Expansion) Type Air Conditioning Indoor units.
Installation testing and commissioning of inverter type air cooled Air-conditioners each complete with scroll compressor,air cooled condensor, GSS casing, filters, cooling coils, fanmotors, insulated copper refrigerant piping as per drawing control wiring, refrigerant controls and accessories, including MICRO-PROCESSOR CONTROL with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipments requirements with Micro-processor control panel for each machine.
11 TR Ductable Indoor Unit
Installation,of Refrigerant piping (suction,Discharge) Hard Drawn Copper piping of suitable sizes, with copper elbows, tees,tubular Nitrile Insulation. Make:Totaline/Uniflow/Rajco/Mandev/Mexflow
Laying of cable between indoor and outdoor unit. (Power and Communication). Make : Havells, Finolex, RR, equivalent
Installation of Auto-Change Over Relay with settable timer, suitable for alternate running both Ductable A/Cs periodically, with incoming feeder.
Installation of 25/32 mm dia. pvc pipe, Drain pipes using minimum 25mm dia and above, consider the machine size and grouping. This shall be insulated with 9mm thick nitrile rubber insulation, with necessary fittings like elbows, tees and reducers etc.
Air Disribution Works
Installation of 22 Gauge Ducting (0.8) of Galvanised Sheet Rectangular Ducting complete with all fittings such as reducers, Tee bends, take offs, suspension, Hi Tech supporting arrangements for plenum, complete as required for air-conditioning application
Installation of 22 Gauge Ducting (0.8) (GI) Thermally insulated drain pan of GI or aluminium sheet,15 cm below unit with at least 5 cm more than size of the unit on all fours sides.Drain pan height shall be minimum 5 cm with drain outlet of 1 inch. The drain line shall be connected to unit drain with proper slope.
Air Oulets
Installing powder coated extruded Aluminium Supply/Return air Grills
Installaion of flexible duct Canvas connector for ductable unit connection to air ducts
Lifting, shifting & positioning of DX Condensing unit on MS Platform with a mechanised arrangement
Insulation Works
Thermal Insulation : Fixing of 9mm thick Class O nitrile rubber insulation with in-built lifetime anti microbial protection, with al. foil. Insulation density shall be 40-60 Kg/m3. Thermal conductivity to be 0.033 @ 0 deg C mean temperature and water vapour diffusion resistance should be 7000 without any external vapour barrier.
Drain PanThermal Insulation : Fixing of 13mm thick Class O nitrile rubber insulation with in-built lifetime anti microbial protection,with al. foil. Insulation density shall be 40-60 Kg/m3. Thermal conductivity to be 0.033 @ 0 deg C mean temperature and water vapour diffusion resistance should be 7000 without any external vapour barrier
Acoustic Insulation : Supply, installation and testing of acoustic lining with 10 mm thick open cell nitrile foam on the inner side of ducting including providing, fixing and finishing the same as per specifications for ducts as required density of material shall be 140‐180 kg/m3.
Outdoor Stand for 11.0 TR Inverter Ductable Unit
Welding works for indoor support hanging
Room Insulation
Thermal Insulation : Fixing of 13mm thick Class O nitrile rubber insulation with in-built lifetime anti microbial protection with al. foil. Insulation density shall be 40-60 Kg/m3. Thermal conductivity to be 0.033 @ 0 deg C mean temperature and water vapour diffusion resistance should be 7000 without any external vapour barrier. (Underdeck Insulation)
Thermal Insulation : Fixing of 13mm thick Class O nitrile rubber insulation with in-built lifetime anti microbial protection with al. foil. Insulation density shall be 40-60 Kg/m3. Thermal conductivity to be 0.033 @ 0 deg C mean temperature and water vapour diffusion resistance should be 7000 without any external vapour barrier. (Wall Insulation)
Mark Matrix Security Solution (BID ID -922810)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.07 MB
TenderDocuments.pdf
Tender Documents • 11.72 MB
BOQ_291608.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid