Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 CrAccepted-AOC | ₹22.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹22.8 CrRejected-Finance E 23 KARAMPURA DELHI DELHI 110015 | WEST DELHI | DELHI | 110015 | ₹22.8 Cr | L2 | Rejected-Finance L2 |
Tender Value
Refer Docs
EMD Value
₹22.8 L
Closing Date
3 Jul 2024, 5:00 pmClosed
Executive Director
e-Procurement Cell, Jharkhand State Building Construction Corporation Ltd., Ranchi.
Construction of Synthetic Hockey Field with Lighting at Swami Vivekanand Sports Complex, Gumla
2024_JSBCC_86648_1
JSBCCL/02/2024-25
Open Tender
Civil Works - Buildings
365 days
Gumla
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹22.8 L
2 Sept 2024
19 Jun 2024
4 Jul 2024
19 Jun 2024
3 Jul 2024
19 Jun 2024
Amount
Earthwork in exacavation in foundation trenches in ordinary soil(vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M including all lifts, levelling, ramming the foundation trenches, removing roots of trees shrubs all complete as per approved design, building specification and direction of E/I.
Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)
Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.
Filling in foundation trenches and plinth in layers not exceeding 1.50 mm thick, well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 m and lift of 1.5m. Al.
Providing coarse clean sand in filling in foundation trenches or in plinth in layers not exceeding 1.50 mm thick including ramming and watering with all leads, cost of material, labour, royally and taxes all complete as per building specification and d.
Providing designation 75 B brick in C.M (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, costs of screening materials, raking out joints to 15 mm depth, curing taxes and royally all complete as per building specification and direction of E/I.
Providing designation 75B work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints of screening materials, scaffolding, ranking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 125mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening, carriage of materials, raking out joints to 15mm depth curing taxes and royalty (but excluding the cost of reinforcement) all complete as building specification and direction of E/I.
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in superstructure and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Providing R.C.C. M-200 in with nominal mix of (1.1.5.3) in band at plinth level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).lintel
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).lintel
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).roof slab
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).chajja
Weather shade, Chajjas, corbels etc., including edges
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ)
Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
S/F 35mm thick solid core type decorative single leaf flush door and windows with black board core banded with high quality phenol formaldehydes synthetic resin both side commercial veneered of standard make with oxidized iron fittings such as hinges, sliding door bolts tower bolts, handles or rings hooks and eyes, cleats sand block as per schedule taxes and royalty all complete as per building and direction of E/I.(one side teak)
Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
S/F 35mm thick solid core type non-decorative double leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial vennered of statdard make with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand direction of E/I.
Providing TMT steel reinforcement 8mm dia rods to 12mm dia as per approved design and drawing excluding carriage of M.S. roads (Straight or in coils) to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.
Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
Supplying, fitting and fixing M.S. grill gate with M.S. grill made of 20X6mm M.S. flats or 16mm M.S. square bars fitted on 25X25X6mm M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
S/F M.S. grill made of 20 x 6mm M.S. flat as per approved designious fillet welded and finished smooth, hoisting carriage of grill to worksite hoisting as per building specification and direction of E/i.
Providing and fixing fan hook of 16mm dia TMT M.S. bar I meter long bent to required size and shape placed in position and fixed in RCC slab/beam at the time of casting all complete as per building specification and direction of E/I.
S/F local make collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat disgonal with top and bottom rails of T iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts nuts locking arrangements steppers handles including applying a priming coat of red lead paint carriage hoisting and taxes all complete as per building specification and direction of E/I.
S/F local make fully glazed steel door, windows or ventilation of standard rolled 'Z' and mullion steel section and size as per IS - 38 joints met welded with 100 x 16 x 3mm M.S. lug fixed in cement concrete (1:2:4) blocks, 15 x 10 x 10cm size including cost of oxidized iron fitting with hinges, handle per step catch springs, 3mm thick plain glass panes with aluminum beads and inner frame fixed with lugs with 20mm long 6.3mm GI. counter sunk machine screw and nuts and applying a coat red lead paint carriage to work site hoisting and plcing in all position in all storys and taxes all complete as per building specification and direction of E/I.
Designing (aesthetically) and construction RCC ground reservoir/Rcc sumps in M 30 mix of required capacity…
S/F 20mm dia M.S. bar I meter long holding down bolt with nuts and washers 100 x 100 x 6mm plate fitted and fixed with cement concrete (1:2:4) as per design all complete as per building specification and direction of E/I.
Providing designation 75B one brick flat soiling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips intwo layers, bottom layer 19mm thick (1:2:4) with 12mm to 6mm down stone chips in panels including cost of curing, finishing the surface smooth by rubbing with carborandom stone taxes and royalty with all complete as per building specification and direction of E/I.
Providing 12mm thick cement concrete flooring (1:2:4) with 20mm to 6mm size graded stone chips finished with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandom stone taxes and royalty with all complete as per building specification and direction of E/I.
Providing 12mm cement plaster (1:3) with clean sand of F.M. 1.5 with flooring coat of neat cement in skirting including rounded of junction with floor, curing, taxes and royalty all complete as per building specification and direction of E/I.
Extra for Providing 30 mm x 4 mm Glass strip in joints of flooring ,complete job as per Specificatin and Direction of E/I
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. (iv) 600X600 mm size
Providing and laying 15mm to 23mm thick kotah stone tiles in risers of step, skirting and pillars of approved size texture and colour laid over 12mm thick cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing to granolilthic finish with approved quality of carborandom stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying Double Charge vitrified floor tiles in Different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS 15622/ISO 13006, of approved make , in all colour and shades laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointed with grey cement [email protected] kg /sqm including grouting the joints with white cement and matching pigment etc.Size of tiles 600x600mm
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I.
Providing 12 mm cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water. Scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 6mm thick cement plaster (1:4) in ceiling with coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty as per building direction of E/I.
Providing 1.5mm cement pumming including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
Providing 19 mm thic cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening curing with all leads lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I.
15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand)
Providing 25mm water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5% cico or any other approved water proofing compound including curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Making 6 x 6 mm grooves in plaster over walls truly horizontal or vertical as specified at regular intervals at all heights including cleaning, finishing, scaffolding and curing with all leads and lifts of water all complete as per building specification and direction of E/I.
Providing two coat of oil bound distemper of approved shade and make over a primer coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding, washing floors and taxes all complete as per building specification and direction of E/I.
Providing two coat of snowcem shade and make over a coat of cement of primer on new surface including preparing the plastered surface smooth with sand paper, soaping, curing and taxes all complete as per building specification and direction of E/I.
Providing two coats of synthetic enamel paint of approved shade and make over New Wood Surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing primer one coat of red lead paint of approved make over steel surface including preparing the surface after cleaning removing dust, dirt. Scales amokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (mode of measurement of area shall be multiple by the co-efficient as indicated in building specification)
Providing two coats of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. Granite of any colour and shade
Providing 150mm wide brick drain in cement mortar (1:6) with as. 150mm clear depth and 250mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
Providing and fixing pressed steel door frames confirming to IS : 4351 manufactured from commercial mild steel sheet of 1.25mm thickness including hinges jamb, lock jamb bead and if required angle threshold of mild steel angle of section 50 x 25mm, or base ties of 1.25mm pressed mild steel welded or riidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after-treatment of the surface as directed by Engineer-in-Charge.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth)
Providing and laying Ceramic glazed floor tiles 300 x 300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all coloures, shades, except White, Ivory, Grey, Fume Red Brown laid on 20mm thick bed of Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc. complete.
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of E/W involved, with 75 mm cement concrete (1:4:8) over one brick designation 100A flat soiling in proper grade and slope at the b.
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete. 2nd class teak wood - 50x12 mm
Providing and fixing pressed steel door frames confirming to IS : 4351 manufactured from commercial mild steel sheet of 1.25mm thickness including hinges jamb, lock jamb bead and if required angle threshold of mild steel angle of section 50 x 25mm, or base ties of 1.25mm pressed mild steel welded or riidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after-treatment of the surface as directed by Engineer-in-Charge.
Steel work welded in built up section/framed work, including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required all complete
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Ptructural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing & laying polymer modified cement enjection grouting, water proof treatment in swimming pool Bed, vertical and horizental surface mixed with water proofing compound with complete job as per direction of E/I.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion - Powder coated aluminium (minimum thickness of powdercoating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) - Powder coated aluminium (minimum thickness of powdercoating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer in-charge. pre-laminated particle board with decorative lamination on both sides
Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineerin-Charge. 80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern.
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom. On W.B.M / W.M.M. @ 0.4kg/sqm
Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications
On W.B.M. @ 0.75 Kg / sqm
On bituminous surface @ 0.50 Kg / sqm
Providing and laying of Dense Graded Bituminous Macadam with 100-120 TPH batch type hot mix plant using HBG crushed aggregates of Grading - II as per table 500-10 of MoRT&H Specification 505 (5th revision) premixed with bitumen VG-30 grade (60/70) @ 4 to 4.50% of weight of total mixture, transported to site, laid over a previously prepared surface with Mechanical Paver finisher to the required grade, level and alignment and rolled as per Clauses 501.6 and 501.7 to achieve the desired compaction for finished item of work as directed by the Engineer-in-Charge including hire and operational charges all T&P and all other contingent charges necessary including charges of all materials etc., complete and as per MoRTH specification No. 505(5th Revision) 50 to 100 mm average compacted thickness
Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of grading-II premixed with bituminous binder 60/70 @ 5.4 to 5.6 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects (FIH says to maintain bare minimum porosity of the asphalt subbase) 40/50 mm compacted thickness
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.
Concrete of M10 grade with minimum cement content of 220 kg /cum
Concrete of M20 grade with minimum cement content of 270 kg /cum
CEMENT PLASTER (IN COARSE SAND), 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand)
Neat cement punning
Constructing brick masonry manhole in cement mortar 1:4 ( 1cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S. (non modular) bricks
Rectangular shape 500x500 mm precast R.C.C. manhole cover with frame - M.D. - 10
Excavation in Soil using Hydraulic Excavator CK 90 and Tippers with disposal upto 1000 metres. (Excavation for roadwork in soil with hydraulic excavator of0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m) Including Royalty etc@ Rs. 27.48 per cum, cost of watering, rolling & compaction.
Carraige of material
Bricks - 8km (1k + 7p)
Sand - 10 km
Chips - 22 km
Metal - 22km
Local Sand - 3 km
Fly Ash Brick - 15km
Point wiring in PVC conduit, with modular type switch - Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required.
Group a
Group C
Twin control point wiring in PVC conduit, with modular type switch Wiring for twin control light point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch, modular plate, suitable size G.I. box etc. as required.
Power Plug wiring in PVC Conduit (2X4 Sq.mm) :- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor songle core cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required.
Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.
2x1.5 Sqmm + 1x1.5 sqmm earth wire(for Single Separate 5A from nearest switch board and wall fans)
2x2.5 Sqmm + 1x2.5 sqmm earth wire (for switch board circuit to LDB).
2x4.0 Sqmm + 1x2.5 sq mm earth wire
4x6 Sqmm +2x6 sqmm earth wire.(to be used for all LDB & UPS DB.)
Telephone Wiring in Existing Conduit:- Supplying and drawing following pair,0.5 sq. mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface/recessed PVC conduit as required.(2 pair)
S/F PVC Conduit:-Supplying and fixing of following sizes of PVC conduit alongwith the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required for Tele, RJ45 Cat 6 data outlet for computer network. 25 mm
S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required
5/6 amps, one way switch
5/6 amps, 3 pin socket outlet
Telephone socket outlet
S/F Modular type electronic fan regulator - Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
S/F Modular Boxes, base & cover plate:-Supplying and fixing following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required.
S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc. as required
S/F power plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required.
S/F Ceiling Rose:- Supplying and fixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required.
S/F Batten / Angle Holder:- Supplying and fixing batten / angle holder including connection etc as required.
ITC fluorescent fitting directly on surface:- Installation, testing and commissioning of Pre-wired fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube etc.directly on surace or ceiling/ wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
ITC ceiling fan - Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable etc. as required.
ITC exhaust fan upto 450mm sweeo - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing commissioning etc. as required.
Supplying and fixing following way single pole neutral, sheet, MCB disrtibution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 8 way, single door
Supplying and fixing 6 amps to 32 amps rating, 240 volts, "B" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required. 6/32, single pole, "B" series
S/F 'C' series SP MCB:-Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. Make- Legrand/Schneider/ Siemens.
6/32A Single Pole
S/F DP MCB Isolator - Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
G.I. Earth electrode with salt/charcoal - Earthing with G.I. earth pipe 4.5 mtr. Long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required
COPPER EARTH PLATE ELECTRODE:-Copper earth plate elecrtode - Earthing with copper earth plate 600mmx 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (with charcoal or coke and salt)
S/L 8 SWG copper wire in ground - Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth, including soldering etc. as required
MV Cable Laying upto 120 Sq mm in ground:-Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm. but not exceeding 120 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc, as required.
Providing and fixing of XLPE, Aluminium Armoured PVC Cable confirming to IS IS7908 (Part-1) 1988 0f grade 1.1KV. Make:- Havells / Finolex / Polycab 1 R for each floor separately ,3.5 Core 50 Sq. mm. 1.1 KV XLPE Al. Ar. Cable from Main LT Panel to VTPN L.D.B Panel.
Supplying PVC/XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor- 3.5 core, 95 sq.mm
Supplying and fixing of 9/10 Watt LED Bulb
Supplying and fixing LED Batten (20/22W)
Supply of LED Batten (20/22W)
Supply of LED Street light (45/48W)
Supply of 9/10 Watt LED Bulb
Supply of LED Street light (45/48W)
Supply and installation of Ceiling fan 48" (1200mm)
Supply fitting fixing and testing of 12" (300mm) metal exhaust fan
Supply fitting fixing of Recess Mounting LED Round Down light (12W)
Earthing with G.I. earth plate 600mm x 600mm x 6mm thick including accessories, and providing masonry enclosure with cover plate having Iocking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
S/L 8 SWG copper wire in ground - Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required
P/F 25mm x 5mm copper earth strip in surface/recess - Providing and fixing 25mm x 5mm copper strip on surface or in recess for connections etc. as required.
MV Cable Laying upto 25 Sq mm in ground:- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc, as required.
MV cable laying upto 95 sq.mm. in ground - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 35 sq.mm. but not exceeding 95 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
MV cable laying upto 400 sq.mm. in ground - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 185 sq.mm. but not exceeding 400 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
MV cable laying upto 35 sq.mm. in pipe - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 35 sq.mm. in the existing RCC/HUME/STONEWARE/METAL pipe as required.
S/D PVC insulated 3.5 core35sqmm Al. Armoured cable.
S/D PVC insulated 3.5 core50sqmm Al. Armoured cable.
S/D PVC insulated 3.5 core185 sqmm Al. Armoured cable.
Supply of exhaust Fan 12" (300mm). Make as per approved by E/I
S/F 9/10 watt LED Bulb Make as per approved by E/I
Supply of ceiling Fan 48" (1200mm). Make as per approved by E/I
Supplying and fixing LED Batten (20/22W) make as [per approved by E/I.
70/72W LED Street light
Supply of LED Street light (45/48W)
HT Aluminium 3 Core 11 KV(UE) cable XLPE insulated Supplying HT aluminium 3 core cable XLPE insulated insulation screened with extruded semi conducting compound in combination with copper tape (0.3kA sor 1sec) cores laid up inner sheath of PVC tape , galvanised steel flat strip armoured ad over all PVc sheathed cable cnfirming IS 7089/II/85 with latest amendments. 3 core 120sq mm
Copper conductor three core , XLPE/ PVC insulated & armoured cable Supplying XLPE/PVC insulated armoured cable 1100 V grade with ISI mark . Three core , solid/ standard aluminium conductor with 6 mm thick 25 mm wide M.S. spacer with G.I. Earth wire 6 sq mm complete in an approved manner 3 core 4 sq mm
Supplying, installation, testing and commissioning of cubical type MV Panel made out of 14 SWG sheet steel, totally enclosed IP-54 protection, free standing, floor mounted dust and vermin proof, indoor type compartmentalized powder coated of approved shade after antirust treatment (with min seven tanks ) suitable with busbar interconnection with suitable size of copper lead/solid Aluminium strips, control circuits & bottom base channel of MS section not less than 75mmx75mmx5mm (thick), Fabrication shall be done in transportable section ,entire panel shall have a common earth busbar at rear with 2 nos earth stud cable alleys, cable gland plates in two half as required as per single line diagram & specification enclosed with the following switchgears. (Main LT panel)
INCOMER:- 315Amp (50KA),manual,fixed,MCCB (1 Nos. ) 1 Set phase indication lights (R, Y, B) 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. 1 No.Ammeter (digital type) with inbuilt ASS 400 Copper. TP&N Copper bus bars( 1 no ) Change over-400 Amp , 4 pole (1 no) OUT GOINGS:- 4 pole MCB100 A,16 kA with fixed thermal magnetic setting.(2 Nos. ) 4 pole MCB 63 A,16 kA with fixed thermal magnetic setting.(6 Nos. ) 4 pole MCB 63 A,10 kA with fixed thermal magnetic setting.(2 Nos. ) 6/32 A,DP (5 Nos. )
Supplying, installation, testing and commissioning of cubical type MV Panel made out of 14 SWG sheet steel, totally enclosed IP-55 protection(Outdoor Type) , free standing, floor mounted dust and vermin proof, indoor type compartmentalized powder coated of approved shade after antirust treatment (with min seven tanks ) suitable with busbar interconnection with suitable size of copper lead/solid Aluminium strips, control circuits & bottom base channel of MS section not less than 75mmx75mmx5mm (thick), Fabrication shall be done in transportable section ,entire panel shall have a common earth busbar at rear with 2 nos earth stud cable alleys, cable gland plates in two half as required as per single line diagram & specification enclosed with the following switchgears. (Main LT panel)
INCOMER:- ( For Migh Mask light) 63 Amp (35KA),manual,fixed,MCCB (1 Nos. ) 1 Set phase indication lights (R, Y, B) 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. 1 No.Ammeter (digital type) with inbuilt ASS copper. BUSBAR CHAMBER:- 100 Amps. TP&N Copper bus bars -1 nos OUT GOINGS:- 16 Amp (10KA),manual,fixed,MCCB (5 Nos. )
TRANSFORMER Power Transformer (with off load Tap changer) Supplying outdoor type copper wound transformer continously rated for 3 Ph 50Hz at full load and temp rise not exceeding 45 deg C by thermometer in oil and 50 deg C by the resistance in winding after continous run at full load rating….Norms issued by JSEB or which ever is lower 200 KVA (No Load Loss 500w amd Load Loss 3000w)
Silent type D.G Set of capacity 500 KVA With AMF Panel IS/IEC-60034-1 IS: 1460 IS: 13018
Oil (Fuel) Filter for 500 KVA DG set
Mobil Filter for 500 KVA DG set
Air (inner + outer) Filter for 500 KVA DG set
SMPS 24V Battery charger for DG se
Providing and fixing N.P./C.P. brass/PVC procelain shower rose of 15mm inlet etc. all complete as per specification and direction of E/I. Shower Rose - 125mm
Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I. 15 mm dia
Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I.
25 mm dia
32 mm dia
Making holes in walls for laying G.I. pipe and restoring the same after pipe laying as per specification and direction of E/I.
125 mm thick wall
250 mm thick wall
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.
450mm X 300mm size
C.P. brass tower rail
C.P. brass soap container medium quality with screw and hinges etc.
Supplying, fitting and fixing viterious white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair or viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. 580mm long - With 12.5 lit. low level PVC cistern
Supplying, fitting and fixing 40mm highb viterous white glazed earthen E.W.C. with 'P' trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fitting with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stope cock of approved quality weight not less than 450 grams 15mm PVC alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic soild state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I. With 'P' trap - 12.5 lit low level PVC Cistern
Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of 'Hindustan "Parry" or any other approved I.S.S. make with 5 liters capacity C.I. automatic flushing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S., brackets, standard size G.I. flush pipe with fitting clamps, 15mm, C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm P.V.C./Alkthene pipe 450mm long with brass coupling at both ends and doing plumber joints including painting coat of red oxide cutting wall and floor making good the same etc. all complete as per specification and direction of E/I.
Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on pointed C.I. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms. 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Labour for laying, fitting and fixing NP2 R.C.C. spu pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leak, proof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complete as per specification and direction of E/I. 150mm dia RCC spun pipe - Upto 3.0 metre depth of invert below G.L.
Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
Supplying NP2 R.C.C. hume pipe with colour as work site as per direction of E/I. 150mm dia
Approved basic rates construction materials for preparation of schedule of rates only, (Material should conform to relevent B.I.S. specification). The rates are inclusive of all taxes, royalty, cess and carraige but exclusive of contractor's profit and overhead charges - Special type of C.P. Bath room fitting for V.I.P. buildings (JAL, Jaguar, Marc or equivalent mark)
Pillar cock
bib cock
Angular Stopcock /2 way bib cock
Telephonic shower flexible pipe
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
75 mm diameter
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Single tee without door - 75x75x75 mm
Single tee without door - 110x110x110 mm
75 mm bend
110 mm bend
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot DipGalvanised with serrations and serrated washers to arrest the wind loadmovement, fasteners, SS 316 Pins and anchor bolts of approved make inSS 316, Nylon separators to prevent bi-metallic contacts all completerequired to perform as per specification and drawing The item includescost of all material & labour component, the cost of all mock ups at site,cost of all samples of the individual components for testing in an approvedlaboratory, field tests on the assembled working curtain wall with aluminiumcomposite panel cladding, cleaning and protection of the curtain wall withaluminium composite panel cladding till the handing over of the building foroccupation. Base frame work for ACP cladding is payable under the relevantaluminium item.s The Contractor shall provide curtain wall with aluminiumcomposite panel cladding, having all the performance characteristics allcomplete , as per the Architectural drawings, as per item description, asspecified, as per the approved shop drawings and as directed by theEngineer-in-Charge. However, for the purpose of payment, only the actualarea on the external face of the curtain wall with Aluminum CompositePanel Cladding (including width of groove) shall be measuredin sqm. up to two decimal places.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
HYDT: Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to125.00 M
(c) From126.0 M to150.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
STARTER D.O.L. starterwlth SS Enclosure wlth 380/41S Volt coit 5 to 10 H.P
Supplying fitting and fixing 3 crore 4 sqmm Flat copper conductor PVC sheathed & PVC insulated submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Supply & fitting G.I 50mm dia pie (tAtA or equivalent make) as per IS:I238- (part-01) I 2004lSt Marked / Medium euality 50 mm nominal outer dia Pipes
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 100 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for allleads & lifts, all complete as per direction of Engineer-in-charge
Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge
DT : Basic rates for 125/115mm dia drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of E/I.. (Basic Rates) Drilling upto 30 mtr. Depth below G.L. in Rural Area
NON-SCHDULE ITEM
SUPPLING AND LAYING OF ARTIFICIAL TURF FOR HOCKEY Supply & Installation of FIH Global Certified Hockey Turf from FIH Preferred Manufacturer having pile height of 13mm both recommended for water or sand dressed hockey international tournaments and national level tournaments, should have following specifications; Composition PE, Structure Monofilament curl, Dtex PE8000, Tape thickness 130μm±15μm, Tape width 0.8-1.0mm, Pile height 13mm±1mm, Gauge 3/16 inch, Stitches per 10cm 34±1, Stitches per m2 71400 ±100, Total yarn weight 1860g/sqm ±10%, Primary backing "PP + polyester fiber short-staple +, Mesh scrim inlay", Secondary backing Latex, Total carpet weight 3100g/sqm ±10% (SAND DRESSED PITCH) Installation of Turf should be done using a seam tape & suitable PU adhesive. Adhesive TDS should match the following basic properties; Colour & Form: Grass-green paste, Characteristics: 2 component polyurethane-reaction adhesive, for outdoor use. Specific Gravity: 1480 g/litre., Viscosity: Thixotropic, Solids: 100%., Application: Notched trowel or by suitable machine for applying to Seaming Tape. Shock-pad (in-situ) Supply & Installation of 15mm Thick insitu shock-pad having Black Styrene-Butadiene Rubber granules size 1~4mm. Mixing ratio of Binder with weight of rubber material should not be less then 15%.
Chain Link Fencing Providing & Fabrication of Chain Link Fencing with the following specification. - 3mm GI Wire with a tolerance of ± 0.15mm. - Total thickness will be 3mm with the same tolerance as mentioned. - Color Green - UV Resistant * No Roof covering by Chain Mesh Poles: * 48.3mm OD MS Poles (Vertical & Horizontal) * Apollo / Jindal or equivalent * Thickness 2mm * Shape - Round * Primer & Enamel painted (Buss Green Color) *Diagonal Support to Fence from outside whereever required
Moveable Hockey Goal Post Providing of Hockey Goal post, FIH specification, 12' x 7' size, 2" x3" square pipe thickness 3mm (Made of GI Pipe)
Dugout sitting system Dug out seating with middle backrest seats, one seating to have minimum 10 number of person space to sit, Sunshade can be with blue / white / light green / transparent / grey color. Material for chair should be HDPE (High Density Polyethylene), material for under structure is mild steel with surface powder coated and for sunshade is Polycarbonate or similar.
LIGHTING Supply of 20Mtrs STADIUM MAST with Ladder with Erection and commissioning of the System - Suitable for 16 Nos of 500 W LED Luminary Each Pole - Power : 500W. - IP Rating : IP66. - Operating Voltage : 180 V to 265 VAC. - LED : OSRAM / CREE. - LED Efficacy : 201 lm/W. - Colour : Cool White. - Colour Temparature : 5500K to 6500K. - LENS as per Neema Standards - 45/60 Deg. - BIS Approved Lights. - Over Voltage and Under Voltage Protection. - Power Factor : 0.98 - Inrush Current Limiter. - I thd < 10%. Supply of Cables and other accessories: - Control Panel/Junnction Box at the bottom of the pole - Terminal Block , Circuit Breaker etc. - Cable 2.5 Sqmm, 3 core Copper cable - All lights can control by one MCB. Supply of Cables from Pole to pole - 4C 35 Sq.mm Al Cable - 400 Mtrs. Note: Supply of cable and Laying of the cable from the Grid source of power to the one of the pole (Master Control panel) will be provided by the customer. (Total 4 Nos. High Mast Poles with 64 LED Lights)
Corner Flags
FIH Certification of Ground (National, FIH Category-2 or 3 as feasible)
Supplying & Laying RCC Drain covers over the drain of size 600x500x70mm, Single layer of 8 mm dia torr steel at 100 mm c/c b/ws with 8 holes
CHAIR FOR DUDOUT
Examination of existing Electric power cable and replacement where necessary completed as directed along with carefully dismantling existing Metal Halide fixtures including Drivers from their existing location& submitting them to client
Supplying, fitting, fixing of LED lights and as per bidder's design
Repairing of Internal electrical wiring inside the High Mast if required along with Modification of existing wiring inside the racks to suit the driver of LED floodlights offered.This includes Supply of 4cx2.5 sq.mm. XLPE insulated unarmoured copper cable as required for energsing the LED flood light.
Flood Light Aiming of LED flood light as per the Design and specification at site with necessary guidance and Hand over the System with all the necessary details & documents including measurement of the Lighting Lux level at site as per the Design and specification
Annual Maintenance of the Entire Flood lighting system (The bidder shall carryout a bi-annual checks and cleaning of the complete system and submit report to authority. The lights shall be operated to check for 100% performance.)
Supply of Outdoor P10 LED Display Board Display Muddle Size 320mmX 160mm Display Size 3200mm X 320 mm Specifications as Follows :- • LED Color - RED • Voltage – 5 V • Power - 25 W • Pixel Pitch - 10mm • INTERFACE (a) Wi-fi • LED life time >= 10000 hrs • Module Size 320*160*25mm • Pixel Density n -10,000 • Brightness >=5500 • Module Weight < 400gm • Horizontal Viewing Angle 120(Digree) • Humidity 0 -90% • Best View Distancing 10 – 40 m • Input Power Frequency 50/60 Hz • Warranty -Min One Year • Cabinet made of min - ACP Sheet
INSTALLATION/ COMMISSIONING MS Structure, Welding Work ,ACP WORK + CABLE LAYING AND INSTALLATION + MANPOWER (YOUR SITE)
1 UNIT OF 6 SMD OUTDOOR LED SCREEN HAVING DIMENSION OF 33’4’’ X25’2’’ Sq feet
LED Video Processor Input- HDMI x1 DVI x 1 VGA x 1
Installation +manpower as per site requirement
Scribing Work Painting Work & Scribing Work
Aluminum Composite Panel ACP Sheet3.5MM Thickness
Supplying And Laying Data Cable site of Site
Supplying & Laying at site of following size PVC insulated XLPE power cable of 1.1 KV grades of cupper categories relevant as required. ( 3 x 4 sq.mm )
Add 18% GST
Add 1% Labour cess 1%
shiv naresh sports pvt ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid