Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | L1 | Accepted-AOC lowest reasonable tender | |
| 2 | L2₹5.2 L+₹1,620 (0.31%)Rejected-Finance | L2 | Rejected-Finance Not Lowest tenderer | |
| 3 | L3₹5.7 L+₹44,505 (8.54%)Rejected-Finance PREM SAROVAR HOTEL NAINITAL 263 001 UTTARAKHAND | NAINITAL | UTTARAKHAND | 263001 | L3 | Rejected-Finance Not Lowest tenderer |
Tender Value
₹5.5 L
Closing Date
16 Dec 2019, 6:00 pmClosed
GE Ranikhet
GE Ranikhet
PETTY REPAIR AND DAY TO DAY MAINT WORKS OF INTERNAL / EXTERNAL ELECTRIFICATION AND EXTERNAL WATER SUPPLY AT NAINITAL UNDER GE RANIKHET
2019_MES_296837_1
GE/RKT/66 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE Ranikhet
Class E cat b (i )
8 documents required · 8 mandatory
₹500
Yes
GE Ranikhet
Yes
3 Jan 2020
11 Nov 2019
18 Dec 2019
11 Nov 2019
16 Dec 2019
25 Nov 2019
Amount
BOQ ( SCH 'A') Receiving/recording complaints lodged by the occupants of all Md/OTM Accn of Haldwani, Kamola and Ranibagh area under GE Ranikhet of electrification nature, rectification of the fault / complaints as per the complaint lodged by the user or as given by MES onward KWH meter in respect of main distribution board having switch fuses, MCB distribution board in sheet metal enclosure, point wiring, fixture for light/ Fan/bell/light or power sockets complete repairs to the extent by removing connections from the system, removing faults in wires, batten, conduit, sunk boxes, junction boxes, main switches, MCBs/DBs utility light fittings, FTL light fitting any wattage lamp, holders, AC ceiling/exhaust fans and other connected fixtures of the internal electrification including providing of petty stores such as insulation wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws, nuts as required to rectify the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as directed at site to the entire satisfaction of Engineer-in-Charge/users. Note : (i) All the complaint(s) received will be lodged & rectified by the contractor rep and will have to maintain a proper record as directed in complain register and in
Item No 1 ( Contd ...) complain slip. (ii) Complain slip and complain register will be provided by the contractor without any extra charge. (iii) Complain regiter will be produced on daily basis to JE and Engr-in-charge (iv) The new items provided shall be measured and paid for separately under relevant items of Sch ‘A’. (v) If contractor fails to attend the complaints in reasonable time a recovery of Rs 300 shall recovered per complaint. (vi) Contractor shall employee having ITI or equivalent certificate from Govt. institution with 4 year experience in the said field.
Receiving/recording complaints lodged by the occupants of all Md/OTM Accn of Nainital under GE Ranikhet of water supply nature, rectification of the fault / complaints as per the complaint lodged by the user or as given by MES onward main pipe line to OH PVC tank and OH PVC tank to internal bib tap incl socket, nipple, elbow, tee etc complete repairs to the extent by removing connections from the system, removing faults in pipe line , tap including providing of petty stores such as insulation taflon tape and connected item of appropriate size and length as required to rectify the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as directed at site to the entire satisfaction of Engineer-in-Charge/users. Note : (i) All the complaint(s) received will be lodged & rectified by the contractor rep and will have to maintain a proper record as directed in complain register and in complain slip. (ii) Complain slip and complain register will be provided by the contractor without any extra charge. (iii) Complain regiter will be produced on daily basis to JE and Engr-in-charge (iv) The new items provided shall be measured and paid for separately under relevant items of Sch ‘A’.
Item No 2 ( Contd ...) (v) If contractor fails to attend the complaints in reasonable time a recovery of Rs 300 shall recovered per complaint. (vi) Contractor shall employee having ITI or equivalent certificate from Govt. institution with 4 year experience in the said field.
Taking down carefully by unscrewing from the boards/outlets boxes fittings and fixtures such as switches, sockets, ceiling rose, lamp holders, tube light fittings, regulators cover plate etc and making good of disturbed surfaces complete all as specified and directed.
Supply and Fixing in repair switch piano flush type single pole, one way 6 Amp complete all as specified and directed.
Supply and Fixing in repair socket outlet combination 2 in 1, 5 pin 5 Amps flush type complete all as specified and directed.
Supply and Fixing switch socket outlet combination 2 in 1, 3 pin 5 Amps and 15 Amps flush type complete all as specified and directed.
Supply and Fixing in repair white cover plate with frame 01 module complete all as specified and directed.
Supply and Fixing in repair white cover plate with frame 02 module complete all as specified and directed.
Supply and Fixing in repair white cover plate with frame 03 module complete all as specified and directed.
Supply and Fixing in repair white cover plate with frame 04 module complete all as specified and directed.
Supply and Fixing in repair white cover plate with frame 06 module complete all as specified and directed.
Supply and Fixing in repair switch modular 1 way 6 Amp ,1 module complete all as specified and directed.
Supply and Fixing in repair switch modular 1 way 16 Amp ,1 module complete all as specified and directed.
Supply and Fixing in repair socket , 6 Amp -2/3 pin combined 2 Module complete all as specified and directed.
Supply and Fixing in repair socket , 6 /16 Amp -2/3 pin combined 2 Module. complete all as specified and directed.
Supply and Fixing in repair Modular Bell Push 6 A 01 Module complete all as specified and directed.
Supply & Fixing bell push piano flush type single pole, one way 5 Amp complete all as specified and directed.
Supply & Fixing in repaiirs lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed.
Supply & Fixing in repair MCB single pole, 240 volts, 5 to 30 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed.
Supply & Fixing in repair MCB Triple pole and neutral, 415 volts, 50 HZ,100 Ampere, rupturing capacity 10 KA, 'B’ curve type complete all as specified and directed.
Supply & Fixing in repair MCB Double pole , 240 volts, 50 HZ, 40 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed.
Supply & Fixing in repair MCB Double pole , 240 volts, 50 HZ, 63 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed.
Supply and fixing High quality T8 LED tube rod 18 watt PC base in existing 36 watt normal tube light fitting with cut off connection of existing 36 watt electronic ballast and provision of 23/0.0076 copper flexible core twin core not less than 1.5 meter omplete all as specified and directed. Make HPL cat pat HLPT81418PC(WW) or equivalent cat part in make phillips/wippro/Bajaj, Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
Taking up or down existing GI steel water tubing of any grade 25mm bore including all fittings and accessories from open surfaces, re-threading the old threads, cutting, welding work, etc as required and re-fixing the same after necessary repair works, etc as required ,including new GI fittings(such as bend,elbows,tees, connections, short pieces, back, nuts, unions, caps & plugs etc) and accessories as required in new or old position including necessary excavation work complete all as specified and directed
All as per item No 24 here in before but bore of pipe 20mm
All as per item No 24 here in before but bore of pipe 15mm
Supply & Fixing in repair of GI socket 15 mm dia bore medium grade complete all as specified and directed.
Supply & Fixing in repair of GI socket 20 mm dia bore medium grade complete all as specified and directed.
Supply & Fixing in repair of GI socket 25 mm dia bore medium grade complete all as specified and directed.
Supply & Fixing in repair of GI elbow 15 mm dia bore medium grade complete all as specified and directed.
Supply & Fixing in repair of GI elbow 20 mm dia bore medium grade complete all as specified and directed.
Supply & Fixing in repair of GI elbow 25 mm dia bore medium grade complete all as specified and directed.
Supply & Fixing in repair of GI union 15 mm dia bore medium grade complete all as specified and directed.
Supply & Fixing in repair of GI union 20 mm dia bore medium grade complete all as specified and directed.
Supply & Fixing in repair of GI union 25 mm dia bore medium grade complete all as specified and directed.
Supply & Fixing in repair of GI Tee 15 mm dia bore medium grade complete all as specified and directed.
Supply & Fixing in repair of GI Tee 20 mm dia bore medium grade complete all as specified and directed.
Supply & Fixing in repair of GI Tee 25 mm dia bore medium grade complete all as specified and directed.
Supply & Fixing in repair 4 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc, capacity of tanks exc 500 ltr but n exc 1000 ltrs complete all as specified and directed.
Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc, capacity of tanks exc 1000 ltr but n exc 2000 ltrs complete all as specified and directed.
Supply & Fixing rotational moulded polythene water storage tanks tripple layer (cylindrical vertical with closed top) hoisted and fixed in postion 1000 ltrs capacity with and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram complete all as specified and directed.
Supply & Fixing in repairs float ball brass valve high pressure with polyethlene float and fly nut complete screwed for iron pipes or brass ferrule of 20 mm bore complete all as specified and as directed.
Supply & Fixing in repairs ball valve high pressure with polyethlene float and fly nut complete screwed for iron pipes or brass ferrule of 15 mm bore complete all as specified and directed.
Supply & Fixing in repairs ball valve high pressure with polyethlene float and fly nut complete screwed for iron pipes or brass ferrule of 25 mm bore complete all as specified and directed.
Supply & Fixing in repairs vitreous China squatting pan, Orissa pattern, size 580 x 440 mm white, with integral foot rests squat pattern closet also includes setting the trap and pan in lime concrete (1 lime, 2 sand or surkhi and 5 aggretate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing (thickness as indicated) and making good floor complete all as specified incl cutting to the flush pipe and necessary repair to the floor complete all as specified and directed.
Supply & fixing PVC Flushing Cistern 10 litre capacity, Low Level Valve Less, Symphonic Action type, White, with Inlet, Ball Valve, Float and Handle including 32mm dia PVC Flush Pipe, a Pair of MS Brackets,CP flush bend including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 including taking down unserviceable Flushing Cistern and connected Items of any description, complete all as specified and as directed.
Supply & fixing in repairs vitreous china wash down water closet pan (padestal pattern) white with flush pipe of chromium plated brass 32mm dia for low level flushing cistern including plastic water closet seat white with jet, closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device fixed in repairs complete all as specified and directed.
Supply & Fixing vitreous china wash basin, white, flat back, size 550mm x 400mm, including brackets, PVC waste pipe 32mm dia, waste coupling brass, chromium plated and including cutting for and pinning in ends of brackets or erecting stand, fixed in repairs complete all as specified and directed.
Supply & fixing in repair 32 mm size (dia of discharge pipe) waste coupling of PTMT half of full threaded (minimum weight 45 gram) complete all as specified and directed.
Supply & fixing Rubber or vulcanite plugs (waste) with rings and fitting and fixing brass union 32mm dia complete all as specified and directed.
Supply & fixing in repair PVC Connections 15mm size with PTMT Nuts of length 450mm and fixed, complete all as specified and as directed.
Supply & Fixing in repairs Towel rod 20 mm dia D type 600 mm long of between flange including CP brass screw and wooden/ plastic sheet with fixing arrangement complete.
Supply and fixing in repair pillar tap 15mm dia cast copper alloy with capstan head chromium plated fancy type, screwed down high pressure, with or without letters ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified .
Supply & fixing in repairs chromium plated fancy type bib taps cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe of bore 15mm complete all as specified and directed.
Supply & fixing in repairs 15 mm bore fancy type, chromium plated stop vlave cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
Supply & Fixing in repair Grating 100mm dia of PTMT ( Minimum weight 25 gms) complete all as specified and directed.
Supply & Fixing in repair plastic seat cover coloured suitable for water closet pedestal pan, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinges devices complete all as specified and directed.
Supply & Fixing in repair CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and direcated.
Supply and fixing Angle cock 15 mm dia cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule fixed in repairs including making good the distrubed surface to match with existing surface Complete all as specified .
kumar automobiles
Ramsons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .