Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAdmitted-Finance NEAR ROADWAYS WORKSHOP PITHORAGARH DISTRICT PITHORAGARH | ₹29.7 L | L1 | Admitted-Finance |
| 2 | L2₹29.8 LAdmitted-Finance TAKANA COLONY PITHORAGARH UTTARAKHAND | PITHORAGARH | UTTARAKHAND | 262501 | ₹29.8 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | D N CONSTRUCTION L1 | MANISH CHAUDHARY M/S OM SAI ENTERPRISES 48 JAGDAMBA COLONY PITHORAGARH UTTARAKHAND L2 |
|---|---|---|---|---|---|
| 1.00 | Wiring for light point/Ceiling/Wall fan point /exhaust fan/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit with modular switch modular plate suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required. Group C | 266 | Point | 1,359 ₹3.6 L | 1,359.57 ₹3.6 L |
| 2.00 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. | 63 | Each | 550 ₹34,650 | 550.69 ₹34,693.47 |
| 3.00 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | 57 | Each | 679 ₹38,703 | 679.78 ₹38,747.46 |
| 4.00 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit with 2 way modular switch modular plate suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required. | 3 | Point | 1,450 ₹4,350 | 1,451.58 ₹4,354.74 |
| 5.00 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, Single core cable in surface/ recessed PVC conduit as required . 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 630 | Mtr | 200 ₹1.3 L | 200.5 ₹1.3 L |
| 6.00 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, Single core cable in surface/ recessed PVC conduit as required . 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 810 | Mtr | 274 ₹2.2 L | 274.66 ₹2.2 L |
| 7.00 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, Single core cable in surface/ recessed PVC conduit as required . 4 X 10 sq. mm + 2 X 6 sq. mm earth wire | 190 | Mtr | 745 ₹1.4 L | 745.7 ₹1.4 L |
| 8.00 | Supplying and flxing brass batten/angle holder including connection etc. as required. | 72 | Each | 160 ₹11,520 | 160.68 ₹11,568.96 |
| 9.00 | Supplying and fixing 3 pin, 5 amp. ceilling rose on the existing junction box/ wooden block including connection etc. as required | 59 | Nos. | 89 ₹5,251 | 89.26 ₹5,266.34 |
| 10.00 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).4way (4 + 18), Double door | 6 | Nos. | 4,213 ₹25,278 | 4,213.28 ₹25,279.68 |
Tender Value
₹29.8 L
EMD Value
₹60,000
Closing Date
24 Feb 2026, 3:00 pmClosed
PM Pithoragarh BRIDCUL
BRIDCUL, Project Unit Pithoragarh, 1st Floor Bhatt Engineering, Army cantt Road Jakhni Tiraha Pithoragarh
Electrical and Allied work of Working Women Hostel at Pithoragarh
2026_BRID3_91966_1
1154/BRIDCUL/Tender/26 Dated 09.02.2026
Open Tender
Electrical Works
540 days
Pithoragarh
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
Project Manager, BRIDCUL, Pithoragarh
₹60,000
BRIDCUL Unit Pithoragarh
9 Apr 2026
12 Feb 2026
24 Feb 2026
12 Feb 2026
24 Feb 2026
19 Feb 2026
18 Feb 2026
Wiring for light point/Ceiling/Wall fan point /exhaust fan/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit with modular switch modular plate suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required. Group C
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit with 2 way modular switch modular plate suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, Single core cable in surface/ recessed PVC conduit as required . 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, Single core cable in surface/ recessed PVC conduit as required . 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, Single core cable in surface/ recessed PVC conduit as required . 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and flxing brass batten/angle holder including connection etc. as required.
Supplying and fixing 3 pin, 5 amp. ceilling rose on the existing junction box/ wooden block including connection etc. as required
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).4way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
S/F of 12-18 WATT LED BULB.
Supply and Fixing of LED Tube Light with batten suitable for up to 1x22 watt LED tube Light fitting including tube on surface complete in all respect.
Supply and fixing of recess mounting round 15 to 18 watt LED Down lighter having power coated die cast aluminium housing with heat sink,diffuser/Reflector and driver set complete in all respect.
Supply and fixing of LED Street light fitting having die cast aluminium body and diffuser with driver set suitable for 50 watt.Confirming to IP 66 protection complete in all respect.
S/F of ceiling fan 1200 mm size
S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16 S.W.G. MS sheet incorporating 10mm dia. M.S bar round and duly painted with red oxide along with all work.
S/F of 9inch size Exhaust Fan.
S & F surface/Flush mounting 4 Ways V TPN distribution board with additional metal door without MCB Complete in all respect as directed at site by Engineer in charge.
Supply and burring of safe Earthing Electrode T-19 Zn-Zinc Coated,Length 2000mm,Outer pipe 48.4mmx3.2mm,inner pipe 26.9mmx2.6mm,terminal Dia12mm,Coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conducative property with 50kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square CI Frame with hinged cover and masonary housing(from electrode terminal to switch board cost of 25x3 G.I Strip will be extra).As per C.P.R.I Certified.
S&F of 200 AMP Four pole Mouled case type on load change over switch with enclosure including the cost of labour,T & P and material required for proper completion of the work as per direction and satisfaction of Engineer in charge.
Supply and Erecation of 200 Amp TPN rising Mains complete with Top end cover plate etc,On angle iron wall brackets complete in all respect.
Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm .thick sand all around and protected with burnt bricks on sides and on top.On surface the cable run shall be fixed on M.S Clamps etc. of suitable size or as directed by the Engineer-Incharge complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 70 sq.mm 3.5 core
Supply and fixing of plain or pin type copper in plated cable socket (lug) to the cable leads,insulting with tape and making connection etc.complete in all respects as per direction of the Engineer-Incharge.70 sqmm,3.5 core
Supply and fixing of brass nickle plate compression gland for pvc insulated and armoured served sheathed,under ground cable including rubber rings etc complete in all respect.The armouring of the cable shall be properly connected with the earth as per direction of Engineer Incharge.70 sqmm,3.5 core
Fire Fighting work.Supply,Installation,Testing and Commissioning of Main Pumps set with electric driven motor pumps,The pump shall be join with 7.5 HP Fire pump.
Supply,Installation,Testing and commissioning of AUTO Manual starter with all fitting
SITC of 4 core 2.5 mm Aluminium Armoured cable
SITC of Tank nipple
SITC of Butterfly 3 inch
SITC of Air Realase valve with Nipple
SITC of NRV 3 Inch
SITC of Flanch 3 Inch
SITC of Redusser with Nipple 65mm x 100 mm
SITC of 1 inch Ball valve with nipple
Hole Tite
SITC of Pressure gauge with nipple
Supply,Installation,Testing and Commissioning of Hydrent line with riser with B Class MS Pipe including welding,Primer,paint with all fitting such as MS Socket,clamps fasteners,teflon tape. 80 mm Dia
Supply,Installation,Testing and Commissioning of Hydrent line with riser with B Class MS Pipe including welding,Primer,paint with all fitting such as MS Socket,clamps fasteners,teflon tape. 25 mm Dia
Supply,Installation,Testing and Commissioning of 25mm dia 30 mtr long swing type 180 degree adjustable with complete drum set first aid hose reel with nosel(Brass nosel) with complete fitting.
Supply,Installation,Testing and Commissioning of (SS) single head landing wall complete set (63 mtr Dia).
Supply,Installation,Testing and Commissioning of set of RRL pipe for the use of landing valve including with male female coupling,Life saftey safe ex index(A set of 1 pipe with the length of 15 mtr)
SITC of Branch pipe with Nosel
SITC of Double door hose box with key
SITC of Hydrent fleanch ,Gas kit with nut bolt
SITC of Fire smoke detector in wireless smoke detector with nippo battery
SITC of Stand Alone Alarm
Supply,Installation of ABC Type 4 Kg Fire Extinguisher(map 50)
Supply,Installation of CO2 Type 2 Kg Fire Extinguisher
Supply,Installation of Foam Type Fire Extinguisher 9 Ltr.
3 Inch Core cutting
Air Terminal(Horizontal)/Down Conductor. SITC of Vertical air terminal with accessories :Air terminal as per IS-IEC 62305 part-3 16mm rod tappred to 10mm aluminium rod,3 mtr air terminal: semi hard (EAIMgSIO5) suitable for high wind load.Accessories:System consist of fang fix with base and clamp on the top air terminal is erected.Fang fix clamp made of SS Lighting tested for 100 KA 10/350 micro sec waveform,16 Kg stone of 365 mm diameter high level of stability,Concreate frost-resistant can be stacked.
SITC OF 8 mm Aluminum Round conductor & meets the requirments of IS/IEC 62305.Cross section 50 Sqmm,semi hard AL Mg Si 0.5
SITC of Roof Conductor holder for sheet.Roof conductor holder of polyamide bottom section stainless steel with Dia 8.5 mm slot.Weather and temperature resistant from -35 degree Cc To +90 Degree C
SITC of HOT dip galvanized cross connector for T and cross connection BET Tested for round conductor 8-10 mm with hexagonal boalts M6X16(VA0
SITC of vario quick connector FT for cross and parallel connectors.
SITC of HOT dip galvanized Test joint suitable to connect 8-10 mm round conductor and max by 5 mm GI strip with 4 hexagonal boalts stainless steel M6X12 BET Tested & Meets the requirments IS/IEC 62305
SITC Of Flat conductor holder suitable for FL 30 Installed with 2 hexagonal bolts.
SITC of Flat strip 30x3mm hot dip Galvanized steel strip meets the requirments of IS/IEC 62305 and Zinc coating of 500 g/m2(apporoxx70μm)
SITC Of cable bracket with cross bar an 2 hexagonal bolt with loose round pin.
SITC of Maintenance free copper bonded earth rod of 2000mm electrode having diameter of 14.2 mm with 250 micron copper coating.Earth enhancing mineral compound 25kg which is not required frequent addition of water.FRP Earth pit chamber.The system is conforming to IEC 60364,IEC 62561,IS/IEC 62305 & IS 3043
SITC Of 200ltr Non-Pressurised solar water Gyser plant system with interconnected Hot water pipe complete work done as per Engineer Incharge.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_108899.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
sbdworkingwomenhostelpithorgarhf.pdf
Tender Documents • 1.76 MB
BOQ_108899.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid