Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC 72 546A ERATHARA H LIBERTY LANE KALOOR PO KOCHI 682 017 | KOCHI | ERNAKULAM | KERALA | 682017 | L1 | Accepted-AOC CA No. GE (AF)/ TVM/ 50 OF 2019 - 2020 | |
| 2 | L2₹9.1 L+₹1.2 L (14.5%)Rejected-Finance REVATHY TC 79 1020 3 SREE RAGAM ROAD KARIKKAKOM KARIKKAKOM PO THIRUVANANTHAPURAM 695021 | THIRUVANANTHAPURAM | KERALA | 695021 | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹9.2 L+₹1.2 L (15.3%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted |
Tender Value
₹11.5 L
EMD Value
₹23,000
Closing Date
11 Mar 2020, 6:00 pmClosed
GE AF Trivandrum
Office of Garrison Engineer AF, Pulayanarkotta, Thuruvikkal Post, Trivandrum-11
REPAIR TO INTERNAL ELECTRIC SUPPLY SYSTEM INCLUDING REPLACEMENT OF U/S FITTINGS WITH LED LIGHTS FOR ACCNS OF 17FBSU, SHANGUMUGHAM, 257 SU MUKKUNNIMALA, KEW COMPLEX AND KUDANKULAM UNDER GE AF TRIVANDRUM
2020_MES_321277_1
GE AF TVM/ 8208
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Trivandrum
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF Trivandrum
₹23,000
Yes
26 Mar 2020
3 Feb 2020
13 Mar 2020
3 Feb 2020
11 Mar 2020
17 Feb 2020
Amount
SCHEDULE 'A'
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors etc all as directed.
M&L for point wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 V grade multi stranded copper conductor drawn through non metallic rigid PVC conduit of size 20mm dia and accessories in surface of walls/ceilings including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including 1.22 mm thick pressed steel terminal boxes with 3.00 mm thick laminated sheet cover to house switch/regulators etc all as specified and directed.
One fan/light point controlled by one switch/bell push
One bell point controlled by one bell push
One switch socket outlet 5 Amps on independent board
One switch socket outlet 5 Amps on the same board
One light point controlled by two way switch
All as per Item No 3 here-in- before but with 4 Sqmm PVC insulated multistranded copper conductor with 4 sqmm cable as earth continuity conductor for power Socket on independent board on the existing/new PVC surface conduit all as directed.
All as per Item No 3 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated copper cable as earth continuity conductor for one switch socket outlet 15 Amps on independent board all as directed.
Supply and fix switch piano flush button single pole one way 5 amps complete all as specified and directed.
Supply and fix switch piano flush button single pole two way 5 amps complete all as specified and directed.
Supply and fix in repairs switch socket combination 3 pin 5 Amps, flush type, four screw type, for 50 Hz 230 Volts AC supply complete all as specified and directed.
Supply and fix switch socket outlet multipurpose, 3 pin 5 and 15 Amp, universal flush type, for 50 Hz 230 Volts AC supply complete all as specified and directed.
Supply and fix ceiling rose surface bakelite with three terminals, for 50 Hz 230 Volts AC supply complete all as specified and directed.
Supply and fix bell push flush type 5 Amps, for 50 Hz 230 Volts AC supply complete all as specified and directed.
S & F in repairs electric bell Ding Dong, for 50 Hz 230 Volts AC supply complete all as specified and directed.
S & F in repairs buzzer, AC 230 volts complete all as specified and directed.
M & L for submain wiring with two runs of 6 sqmm and one run of 6 sqmm for earth continuity using 1100V grade single core multistranded PVC insulated unsheathed FRLS grade copper conductor cable drawn through and including medium grade rigid PVC conduit of 25 mm dia includung accessories such as bends, supports etc including taking down complete all as specified and directed. Note: Two runs of cable, one run of earth wire and one run of conduit shall be measured as unit length.
S & F SPN 4 way distribution board, double door with 100 Amps busbar including disconnecting the connections, reconnecting to new DB and making good the disturbed surfaces including taking down complete all as specified and directed.
All as per item No 15 here in before but SPN 8 way complete all as specified and directed.
All as per item No 15 here in before but SPN 12 way complete all as specified and directed.
S & F in repairs sheet metal enclosure distribution board for fixing MCBs with double door, TPN 4 way, 415 volts with 100 Amps neutral busbar, earth links etc complete all as specified and directed.
S & F in replacement Sheet Metal Enclosure for MAIN DBs, Triple Pole & Neutral, 4 Way , 415 Volts with 100 Amps rated neutral bus bar double door vertical type, grouting the DB and making good the disturbed surfaces with extra cement without any additional cost suitable for TP/SP outgoing to accomodate and including MCCB 100A 16 KA as incoming all as directed
S & F in repairs MCCB of following capacities for 415 Volts 50 Hz AC complete all as specified and directed.
MCCB 4 pole, 63 Amps, 16 kA breaking capacity
MCCB 4 pole, 100 Amps, 16 kA breaking capacity
S & F in repairs metal plug and socket, single phase, two pin and earth plug with MCB SP 20 Amps and steel enclosure complete all as specified and directed.
S & F in repairs electronic type fan regulator rotary step 120/280 watt complete all as specified and directed.
Taking down ceiling fan of 1200mm/ 1400mm sweep from any height and bringing down to floor, dismantling, re-assembling and refixing in position after repairs complete all as specified and directed. Note: Spares will be measured and paid separately
All as per Item No. 23 above but for exhaust fan 300mm/450mm sweep including replacing of rusted nut and bolts complete all as specified and directed.
All as per Item No. 23 abovebut for Pedestal / wall mounting fan of 400/450mm sweep including replacing of rusted nut and bolts complete all as specified and directed.
M & L for cutting & removing the burnt winding of ceiling fan of 1200/ 1400 mm sweep, cleaning the slot, rewinding with super enamelled copper wire of suitable size, varnishing, heating and insulating and reassembling the spares complete all as specified and directed.
All as per item No. 26 above but for exhaust fan 300mm sweep complete all as specified and directed.
All as per item No. 26 above but for exhaust fan 450mm sweep complete all as specified and directed.
Supply only fan motor for wall mounting fan/ pedastal of 400/450mm sweep complete all as specified and directed.
Supply only ball bearing suitable for fans of following sizs complete all as specified and directed.
Ceiling fan of 1200/1400 mm sweep( 6201/6202)
Exhaust fan of 300 mm sweep
Exhaust fan of 450 mm sweep
M & L for preparation of old surfaces of following fans and applying one coat of synthetic enamel paint of existing colour by spray painting including writing MES number of fans complete all as specified and directed.
Ceiling fan of 1200/1400 mm sweep
Exhaust fan of 300/450 mm sweep
Supply only capacitor 2.5 mfd suitable for ceiling fan complete all as specified and directed.
Supply only capacitor 4 mfd suitable for exhaust fan complete all as specified and directed.
S & F in repairs MCB of following capacities for 230 Volts 50 Hz AC with rupturing capacity 9KA supply complete all as specified and directed.
MCB TPN 6A - 32A
MCB TPN 40A - 63A
MCB TP6A-32A
S & F in repairs MCB of following capacities for 230 Volts 50 Hz AC with rupturing capacity 10KA supply complete all as specified and directed.
MCB SP 6A - 32A
MCB SPN 6A -32A
Supply and fix new energy efficent LED Box type fitting 1 x 20 watts 4 feet long CRCA body powder coated white batten type MCL LED type all prewired including connection with twin core flexible PVC 0.5 Sqmm complete all as specified and directed. Make: Wipro Cat Part No.LL20-281-XXX-65AL1 or Philips cat No.BN021 LED20S PSU CW GR 52 or Havells Model No. LUMILINEPLUSBS20WLED865SPCSS
Supply and fix new energy efficent LED Box type fitting 1 x 10 watts 2 feet long CRCA body powder coated white batten type MCL LED type all prewired including connection with twin core flexible PVC 0.5 Sqmm complete all as specified and directed. Make Wipro Cat Part No.LL20-281-XXX-65AL1 or Philips cat No BN021 LED10S 6500 PSU GR 51 or Havells Model No. LUMILINEPLUSBS10WLED865SPCSS
S&F in repairs energy efficient LED building security light Fitting 25 Watts on existing backets including connection with twin coe flexible PVC 0.5 Sqmm cable complete all as secified and as directed as per Philips Model No. BRP022 LED20 CW MR S1 PSU GR or Cat No. ENDURAPEARLSL25WLED757SASYTOPC of Havells or Wipro Cat No. LR02-291-XXX-57-XX
S&F in repair addressible multisensor detector with heat and smoke detector photoelectric/ optical with base ,with self built intelligence complete all specified and directed
S & F in repairs addressable sounder complete all as specified and directed.
Servicing and programming of mother bord and SMPS of of single loop addressible alarm panel complete all as specified and directed
Servicing and programming of conventional type 12 Zone panel complete all as specified and directed
S & F in repairs LED tube rod for 4 feet long tube light fittings, 18 W, for 50 Hz 230 Volts AC supply complete all as specified and directed. Make: Philps Cat No. 20W865T8I or equivalent
S&F Driver for following light fittings complete
25/35 W for bldg security Lights Make : Wipro/Crompton
20 W Batten Fitting Make :Wipro/Crompton
36 W recess/ ceiling Fittings Make :Wipro/Crompton
M&L for preparation of surfaces of Meter Box and applying one coat of synthetic enamel paint over one coat of red oxide Primer complete all as specified and directed.
Taking down the existing water heater from wall and refixing to same location after cleaning and painting and fixing to wall by using proper clamps and nut bolt completely all as directed by Engr-in- Charge.
S & F in repairs heating coil of geyser of cap 1.0 KW complete all as specified and directed.
S & F in repairs thermostat for geysers complete all as specified and directed.
M & L for point wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed 1100 V grade multi stranded copper conductor cable drawn through and including non-metallic rigid PVC conduits and accessories(Concealed) of suitable size on walls/ ceiling etc and including 1.5 Sqmm dia PVC insulated multistranded copper cable as earth continuity conductor fabricated branted Modular metal flush box concealed in walls with Modular suitable plate with cover and suitable screws for housing switches sockets outlets fan regulators etc for the following complete all as specified and directed.
One light/fan point controlled by one way switch
One switch socket outlet 5 Amps on independent board
One socket outlet 5 Amps on the same board
One bell point controlled by one bell push
All as per Item No.48 but with copper conductor cable FRLS 2.5 sqmm for one 3 pin socket outlet 15 Amps concealed and including provision of 2.50 sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board complete all as specified and directed.
Switch Modular type one way 6 Amps , one module
Modular Socket 2/3 pin combined 2 module 6 Amps
Switch Modular type one way 16 Amps One module
Modular Socket 6A/16A-2/3 pin combined 2 module 6 Amps
Modular bell Push 6 Amps
Sub Total of Schedule 'A'
SCHEDULE OF CREDIT
Schedule of Credit (Minus) Rs. 8,470.00 B/F from Ser page No.96. NOTE: Bidder shall insert credit amount as rate Rs. 8,470.00 in Green field under Col-5.
Sub Total of Schedule of Credit
DEFT GROUP ELECTROMECHANICAL
CHITHRANI TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .