Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹11.3 L+₹2.0 L (21.4%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹12.0 L+₹2.7 L (29.1%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹21.6 L+₹12.3 L (132.9%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | Rejected-Technical F 209 INSTITUTE FOR INDUSTRIAL RESEARCH TOXICOLOGY UPSIDC MG ROAD GHAZIABAD GHAZIABAD UTTAR PRADESH 201013 INDIA | GHAZIABAD | UTTAR PRADESH | 201013 | - | Rejected-Technical Non Responsive as per order no 584 DATED 4.9.2025 |
| Sl No | Description | Qty | Unit | ITL Labs Pvt. Ltd. L2 | Jagdamba Laboratories L1 | devansh testing and research laboratory pvt ltd L4 | SHREE KRISHNA ANALYTICAL SERVICES PVT LTD L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Absorbable Surgical Suture (Sterile Catgut),BP/USP Needled Suture Chromic (3/8 Cir RB Needle 40mm Length 76 cm) | 1.1 | 12 Foils | 2,400 ₹2,832 Lowest | 2,500 ₹2,950 | 6,000 ₹7,080 | 4,000 ₹4,720 |
| 2.00 | Absorbable Surgical Suture (Sterile Catgut),BP/USP Needled Suture Chromic (l/2 Cir RB Needle 20mm Length 76 cm) | 1.1 | 12 Foils | 2,400 ₹2,832 Lowest | 2,500 ₹2,950 | 6,000 ₹7,080 | 4,000 ₹4,720 |
| 3.00 | Absorbable Surgical Suture (Sterile Catgut),BP/USP Needled Suture Chromic (l/2 Cir RB Needle 30mm Length 76 cm) | 1.1 | 12 Foils | 2,400 ₹2,832 Lowest | 2,500 ₹2,950 | 6,000 ₹7,080 | 4,000 ₹4,720 |
| 4.00 | Absorbable Surgical Suture (Sterile Catgut), BP/USP Needled Suture Chromic (l/2 Cir RB Needle 30mm Length 76 cm) | 1.1 | 12 Foils | 2,400 ₹2,832 Lowest | 2,500 ₹2,950 | 6,000 ₹7,080 | 4,000 ₹4,720 |
| 5.00 | Absorbable Surgical Suture (Sterile Catgut), BP/USP Needled Suture Chromic (l/2 Cir RB Needle 40mm Length 76 cm) | 1.1 | 12 Foils | 2,400 ₹2,832 Lowest | 2,500 ₹2,950 | 6,000 ₹7,080 | 4,000 ₹4,720 |
| 6.00 | Absorbable Surgical Suture (Sterile Catgut), BP/USP Needled SutureChromic (3/8 RB Needle 30mm Length 76 cm) | 1.1 | 12 Foils | 2,400 ₹2,832 Lowest | 2,500 ₹2,950 | 6,000 ₹7,080 | 4,000 ₹4,720 |
| 7.00 | Absorbable Surgical Suture (Sterile Catgut),BP/USP Needled Suture Chromic (1/2 Cir RB Needle 45 mm Length 100 cm) | 1.1 | 12 Foils | 2,400 ₹2,832 Lowest | 2,500 ₹2,950 | 6,000 ₹7,080 | 4,000 ₹4,720 |
| 8.00 | Absorbable Surgical Suture (Sterile Catgut), Needled Suture Chromic (3/8 Cir RCutting Needle 26mm, Length 76 cm) | 1.1 | 12 Foils | 2,400 ₹2,832 Lowest | 2,500 ₹2,950 | 6,000 ₹7,080 | 4,000 ₹4,720 |
| 9.00 | Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin
/Polyglycolic Acid / Poly(Glycolide-co-L-lactide) | 1.1 | 12 Foils | 2,400 ₹2,832 Lowest | 2,500 ₹2,950 | 6,000 ₹7,080 | 4,000 ₹4,720 |
| 10.00 | Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin
/Polyglycolic Acid / Poly(Glycolide-co-L-lactide) 1/2 Cir RB | 1.1 | 12 Foils | 2,400 ₹2,832 Lowest | 2,500 ₹2,950 | 6,000 ₹7,080 | 4,000 ₹4,720 |
Tender Value
₹1.2 Cr
EMD Value
₹25,000
Closing Date
5 May 2025, 6:00 pmClosed
MD RMSCL
Swasthyabhawan, Tilak Marg, Jaipur
E-BID FOR THE EMPANELMENT OF ANALYTICAL TESTING LABORATORIES FOR THE TEST AND ANALYSIS OF SURGICAL AND SUTURES MEDICAL DEVICES (30.06.2027)
2025_RMSCL_457433_1
F02 188 RMSCL LAB EMPANELMENT SS NIB01 2025 250 Dt 8.4.25
Open Tender
Medicines
Item Wise
21 days
RMSCL Jaipur
RISL Fees, tender Fees, bid security, turn over and all annexure
4 documents required · 4 mandatory
₹2,360
MD RMSCL
₹25,000
Yes
RMSCL
9 Sept 2025
9 Apr 2025
6 May 2025
9 Apr 2025
5 May 2025
23 Apr 2025
17 Apr 2025
Absorbable Surgical Suture (Sterile Catgut),BP/USP Needled Suture Chromic (3/8 Cir RB Needle 40mm Length 76 cm)
Absorbable Surgical Suture (Sterile Catgut),BP/USP Needled Suture Chromic (l/2 Cir RB Needle 20mm Length 76 cm)
Absorbable Surgical Suture (Sterile Catgut),BP/USP Needled Suture Chromic (l/2 Cir RB Needle 30mm Length 76 cm)
Absorbable Surgical Suture (Sterile Catgut), BP/USP Needled Suture Chromic (l/2 Cir RB Needle 30mm Length 76 cm)
Absorbable Surgical Suture (Sterile Catgut), BP/USP Needled Suture Chromic (l/2 Cir RB Needle 40mm Length 76 cm)
Absorbable Surgical Suture (Sterile Catgut), BP/USP Needled SutureChromic (3/8 RB Needle 30mm Length 76 cm)
Absorbable Surgical Suture (Sterile Catgut),BP/USP Needled Suture Chromic (1/2 Cir RB Needle 45 mm Length 100 cm)
Absorbable Surgical Suture (Sterile Catgut), Needled Suture Chromic (3/8 Cir RCutting Needle 26mm, Length 76 cm)
Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-co-L-lactide)
Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-co-L-lactide) 1/2 Cir RB
Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-co-L-lactide) 1/2 Cir RB
Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-co-L-lactide) 1/2 Cir Tapercut Needle (Heavy) 35-40mm length 75-90 cm
Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-co-L-lactide)
Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-co-L-lactide) (1/2 Cir
Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-co-L-lactide)(1/2 Cir RB Needle 20mm length 70 cm)
Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-co-L-lactide ) (1/2 Cir RB
Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-co-L-lactide) (1/2 Cir RB
Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-co-L-lactide) 3/8 Circle
Absorbable Surgical Suture (Synthetic) Sterilised Surgical Needled Suture (Braided) Coated Polyglactin /Polyglycolic Acid / Poly(Glycolide-co-L-lactide)
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE BLACK BRAIDED SILK (1/2 Cir RB Needle 20mm, Length 76 cm)
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE BLACK BRAIDED SILK (3/8Cir Reverse Cutting Needle 26mm,
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE BLACK BRAIDED Silk (3/8Cir Reverse Cutting Needle 45mm,
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE POLYAMIDE MONOFILAMENT BLACK (NYLON)
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE POLYAMIDE MONOFILAMENT BLACK (NYLON)
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE POLYAMIDE MONOFILAMENT BLACK (NYLON)
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE POLYAMIDE MONOFILAMENT BLACK (NYLON)
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE POLYAMIDE MONOFILAMENT BLACK (NYLON) (3/8 Cir R Cutting Needle 40-45mm Length 60-70 cm.)
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE POLYAMIDE MONOFILAMENT BLACK (NYLON)
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (1/2 Cir
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (3/8Cir
NON ABSORBABLE SURGICAL SUTURE,STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (3/8Cir
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (1/2
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (1/2 Cir
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (1/2 Cir tapercut double needle cutting size 16-17mm Length 70- 90 cm)
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (1/2 Cir
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (1/2 Cir
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (1/2 Cir
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (1/2 Cir
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (1/2 Cir
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE USP(3/8 Cir Conventional Cutting PC-3Needle 15mm Length 60cm)
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (3/8 Cir
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (1/2 Cir
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (3/8 Cir
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (l/2 Cir
NON ABSORBABLE SURGICAL SUTURE, ,STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (3/8 Cir RB , 8mm Double Needle, Suture Length of 70Cm)
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (1/2
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (1/2 Circle CC 13mm Needle, Suture Length of 70cm) DOUBLE
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (1/2 Circle Tapercut Needle 17mm Suture Length of 90cm) Double Arm
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYPROPYLENE BLUE (1/2 Cir
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE BRAIDED COATED POLYSTER,GREEN/WHITE or BLUE/WHITE Polybutylate / Silicon Coated Polyster Braided green/ blue (1/2 Cir Tapercut ,17 mm Double Needle, length 75
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE BRAIDED COATED POLYSTER,GREEN/WHITE or BLUE/WHITE Polybutylate / Silicon Coated Polyster Braided White (1/2 Cir Tapercut ,17 mm Double Needle, length 90 cm)
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE BRAIDED COATED POLYSTER,GREEN/WHITE or BLUE/WHITE Polybutylate / Silicon Coated Polyster Braided Green / Blue (1/2 Cir Tapercut ,17 mm Double Needle, length 90
Non absorbable surgical suture sterilized surgical needled suture Polybutylate / Silicon Coated with Polyster Braided (Green / Blue) 1/2 Circle Taper cut , 17mm Double armed Needle, Suture Length of 90cm with pledgets Size 6 X 3 X l.5mm
Non absorbable surgical suture sterilized surgical needled suture Polybutylate / Silicon Coated with Polyster Braided (Green / Blue) *with 1/2 Circle Taper cut , 25mm Double armed Needle, Suture Length of 90cm with pledgets Size 6 X 3 X l.5mm
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE BRAIDED COATED POLYSTER,GREEN/WHITE or BLUE/WHITE Coated Polyster Braided (Green / Blue) with 1/2 Circle Tapercut Double Needle 25mm,
ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE POLYGLECAPRONE / Polyglyconate, MONOFILAMENT SUTURES (1/2 Circle Oval RB Needle 26mm Needle, Suture Length of 70cm)
ABSORBABLE SURGICAL SUTURES POLYGLECAPRONE / Polyglyconate, MONOFILAMENT SUTURES (l/2 Circle Oval RB Contrast Needle 26mm, suture
ABSORBABLE SURGICAL SUTURES Monofilament sutures Polyglecaprone /Polyglyconate (l/2 Circle Cutting 16mm Needle,suture length 70cm)
ABSORBABLE SURGICAL SUTURES POLYGLECAPRONE / Polyglyconate, MONOFILAMENT SUTURES (3/8 Circle
Absorbable Surgical Suture (Synthetic) Sterilised Needled Suture Monofilament Polydioxanone Violet (1/2 Circle Reverse Cutting 40-50 mm Length 70- 90cm)
ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYDIOXANONE Violet (1/2 Circle RB 31mm Needle, Length
ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE MONOFILAMENT POLYDIOXANONE Violet (1/2 Circle RB 30mm Needle, Length
Absorbable Surgical Suture (Synthetic) antibacterial coated sterilised needled suture (Braided coated Polyglactin/ Polyglycolic Acid violet) 1/2 Circle CT round bodied 40mm, GS needle, suture length 90 cm/
Absorbable Surgical Suture (Synthetic) antibacterial coated sterilised needled suture (Braided coated Polyglactin/ Polyglycolic Acid violet)1/2 circle CT round bodied 40mm, GS needle, suture length 90 cm
Absorbable Surgical Suture (Synthetic) antibacterial coated sterilised needled suture (Braided coated Polyglactin / Polyglycolic Acid violet)1/2 circle round bodied
Absorbable Surgical Suture (Synthetic) antibacterial coated sterilised needled suture (Braided coated Polyglactin/ Polyglycolic Acid violet)1/2 circle Reverse Cutting,OS
Absorbable Surgical Suture (Synthetic) antibacterial coated sterilised needled suture (Braided coated Polyglactin / Polyglycolic Acid violet)1/2 circle Reverse Cutting 36mm, OS needle, suture length 90 cm/
Absorbable Surgical Suture (Synthetic) antibacterial coated sterilised needled suture (Braided coated Polyglactin / Polyglycolic Acid violet) 1/2 circle round bodied
Absorbable Surgical Suture (Synthetic) antibacterial coated sterilised needled suture (Braided coated Polyglactin/ Polyglycolic Acid violet)3/8 circle R Cutting, PS-
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE POLYAMIDE MONOFILAMENT BLACK (NYLON) (3/8 Cutting spatulated Edge Needle, Double arm Needle 6 mm,
Absorbable Surgical Suture (Sterile Catgut), Needled Suture Chromic (3/8 Cir RCutting Needle 16mm, Length 76 cm)
Absorbable Surgical Suture (Sterile Catgut), Needled Suture Chromic (3/8 Cir Cutting Needle 8mm, Length 35 cm)
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE BLACK BRAIDED SILK WITH NEEDLE Silk (3/8 Cir
NON ABSORBABLE SURGICAL SUTURE, STERILISED SURGICAL NEEDLED SUTURE BLACK BRAIDED SILK WITH NEEDLE Silk (3/8 Cir
Absorbable Surgical Suture (Sterile Catgut), Needled Suture Chromic (3/8 Cir RCutting Needle 19mm Length 76 cm)
Absorbable Surgical Suture, Sterilised Surgical Needled Suture Polyglyconate, Monofilament Sutures (1/2 Circle Oval RB Needle 26-30mm Needle, Suture Length of 70cm)
Absorbable Surgical Suture Polyglyconate, Monofilament Sutures (l/2 Circle Oval RB Contrast Needle 20-26mm, suture length 70cm)
Absorbable Gelatin Sponge IP 66, Size 80(+-10) mm x 50 mm x 10 mm should be sterlized.
Asepto Syringe with Transparent Bulb Sterile, 60 ml
Blood Administration Set / Blood Transfusion Set Sharp and easy piercing spike suitable for blood bags and standard blood containers Transparent cylindrical drip chamber with filter. Filter size should be 200+20 micrometer. 150 cm long smooth kink resistant tubing Efficient roller clamp to control and adjust the transfusion rate As per IS 9824(Part 3):1996
Disposable Sterile Surgical Rubber Gloves Size 6 ½ Inches Made of natural rubber Latex, powdered, without tear, properly folded in a paper Free of holes, with Acceptable Quality Level (AQL) of 1.5 or less Tensile strength as per EN 455-2 Powder should be non-allergenic As per IS 13422 ISI marked / CE certified / FDA approved
Disposable Sterile Surgical Rubber Gloves Size 6 ½ Inches Made of natural rubber Latex, powder free (Polymer /Silicon Coated), without tear, properly folded in a paper Free of holes, with Acceptable Quality Level (AQL) of 1.5 or less Tensile strength as per EN 455-2 As per IS 13422 ISI marked / CE certified / FDA approved (CE Certification / FDA Approval for item is
Disposable Sterile Surgical Rubber Gloves Size 7 Inches Made of natural rubber Latex, powdered,,without tear, properly folded in a paper Free of holes, with Acceptable Quality Level (AQL) of 1.5 or less Tensile strength as per EN 455-2 Powder should be non-allergenic As per IS 13422 ISI marked / CE certified / FDA approved
Disposable Sterile Surgical Rubber Gloves Size 7 Inches Made of natural rubber Latex, powder free (Polymer /Silicon Coated), without tear, properly folded in a paper Free of holes, with Acceptable Quality Level (AQL) of 1.5 or less Tensile strength as per EN 455-2 As per IS 13422 ISI marked / CE certified / FDA approved (CE Certification / FDA Approval for item is
Disposable Sterile Surgical Rubber Gloves Size 7½ Inches Made of natural rubber Latex, powdered, without tear, properly folded in a paper Free of holes, with Acceptable Quality Level (AQL) of 1.5 or less Tensile strength as per EN 455-2 Powder should be non-allergenic As per IS 13422 ISI marked / CE certified / FDA approved
Disposable Sterile Surgical Rubber Gloves Size 7 ½ Inches Made of natural rubber Latex, powder free (Polymer /Silicon Coated), without tear, properly folded in a paper Free of holes, with Acceptable Quality Level (AQL) of 1.5 or less Tensile strength as per EN 455-2 As per IS 13422 ISI marked / CE certified / FDA approved (CE Certification / FDA Approval for item is
n Catheter, Sterile. Size: FG 5 (For use in respiratory tract) Soft, kink resistant tubing Rounded open tip with lateral eye Colour coded universal funnel connector for safe connection to standard suction equipment Length 50 cm (min.)
Suction Catheter, Sterile. Size: FG 6 (For use in respiratory tract) Soft, kink resistant tubing Rounded open tip with lateral eye Colour coded universal funnel connector for safe connection to standard suction equipment Length 50 cm (min.)
Suction Catheter, Sterile. Size: FG 8 (For use in respiratory tract) Soft, kink resistant tubing Rounded open tip with lateral eye Colour coded universal funnel connector for safe connection to standard suction equipment Length 50 cm (min.)
Suction Catheter, Sterile. Size: FG 10 (For use in respiratory tract) Soft, kink resistant tubing Rounded open tip with lateral eye Colour coded universal funnel connector for safe connection to standard suction equipment Length 50 cm (min.)
Suction Catheter, Sterile. Size: FG 12 (For use in respiratory tract) Soft, kink resistant tubing Rounded open tip with lateral eye Colour coded universal funnel connector for safe connection to standard suction equipment Length 50 cm (min.)
Suction Catheter, Sterile. Size: FG 14 (For use in respiratory tract) Soft, kink resistant tubing Rounded open tip with lateral eye Colour coded universal funnel connector for safe connection to standard suction equipment. As per IS0 8836:2014
Suction Catheter, Sterile. Size: FG 16 (For use in respiratory tract) Soft, kink resistant tubing Rounded open tip with lateral eye Colour coded universal funnel connector for safe connection to standard suction equipment Length 50 cm (min.)
Suction Catheter, Sterile. Size: FG 18 (For use in respiratory tract) Soft, kink resistant tubing Rounded open tip with lateral eye Colour coded universal funnel connector for safe connection to standard suction equipment Length 50 cm (min.)
Suction Catheter, Sterile. Size: FG 20 (For use in respiratory tract) Soft, kink resistant tubing Rounded open tip with lateral eye Colour coded universal funnel connector for safe connection to standard suction equipment Length 50 cm (min.)
Suction Catheter, Sterile. Size: FG 22 (For use in respiratory tract) Soft, kink resistant tubing Rounded open tip with lateral eye Colour coded universal funnel connector for safe connection to standard suction equipment Length 50 cm (min.)
Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size 8 FG Made of Silicone elastomer bonded with Latex Should have hard plastic valve Smooth distal end with smooth eyes for atraumatic intubation Symmetrical foley balloon Balloon capacity 3- 5 ml As per IS 11497 Color coding marking to identify size Length, wall thickness and balloon capacity should be mentioned as per IS 11497. Specification for B,C,D,E,F,G should be mentioned as per IS 11497 for particular size
Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size10 FG Made of Silicone elastomer bonded with Latex Should have hard plastic valve Smooth distal end with smooth eyes for atraumatic intubation Symmetrical foley balloon Balloon capacity 3- 5 ml Color coding marking to identify size Length, wall thickness and balloon capacity should be mentioned as per IS 11497. Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size
Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size16 FG Made of Silicone elastomer bonded with Latex Should have hard plastic valve Smooth distal end with smooth eyes for atraumatic intubation Symmetrical foley balloon Balloon capacity 30 ± 1 ml As per IS 11497 Color coding marking to identify size Length, wall thickness and balloon capacity should be mentioned as per IS 11497. Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size
Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size18 FG Made of Silicone elastomer bonded with Latex Should have hard plastic valve Smooth distal end with smooth eyes for atraumatic intubation Symmetrical foley balloon Balloon capacity 30 ± 1 ml As per IS 11497 Color coding marking to identify size Length, wall thickness and balloon capacity should be mentioned as per IS 11497. Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size
Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size20 FG Made of Silicone elastomer bonded with Latex Should have hard plastic valve Smooth distal end with smooth eyes for atraumatic intubation Symmetrical foley balloon Balloon capacity 30 ± 1 ml As per IS 11497 Color coding marking to identify size Length, wall thickness and balloon capacity should be mentioned as per IS 11497. Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size
Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size22 FG Made of Silicone elastomer bonded with Latex Should have hard plastic valve Smooth distal end with smooth eyes for atraumatic intubation Symmetrical foley balloon Balloon capacity 30 ± 1 ml Color coding marking to identify size Length, wall thickness and balloon capacity should be mentioned as per IS 11497. Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size
Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size 24 FG Made of Silicone elastomer bonded with Latex Should have hard plastic valve Smooth distal end with smooth eyes for atraumatic intubation Symmetrical foley balloon Balloon capacity 30 ± 1 ml As per IS 11497 Color coding marking to identify size Length, wall thickness and balloon capacity should be mentioned as per IS 11497. Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size
Infant Feeding Tube Size:10FG length 50 cm (min.) Two lateral eyes at distal end Soft, kink resistant non-toxic PVC tubing, non irritant to delicate mucosa With female flexible mount with in-built closure Radio opaque line Sterile
Sterile Disposable Perfusion Set with Airway and Needle (Adult Use) For gravity feed only Sharp and easy piercing spike with air vent Transparent and flexible drip chamber 150 cm long smooth kink resistant tubing Self sealing latex bulb which will also act as an port for extra medication Efficient roller clamp to control and adjust the fluid rate 21 G needle
Sterile Disposable Perfusion Set (Infusion set) with Airway and Needle (Paediatric Use) Burette type measured volume chamber of 100 ml Drop size of approx 60 drops per ml Injection port,latexfree, for intermittent medication. Floating auto shut off valve (latex free) in burette. Soft and kink resistant PVC tubing. Roller controller for flow control Tube length 150 cm 23G needle
Disposable Infusion Set with Microdrip (I.V.) Microdrip Infusion set with drop size reduced to approx 60 drops per ml Sharp and easy piercing spike Transparent and flexible drip chamber 150 cm long smooth kink resistant tubing Efficient roller clamp to control and adjust the fluid rate
Insulin syringe ( 40 units) with (fixed) 30 G needle As per (phle Shall conform to tha )IS 12227
Sterile Disposable (Single Use) Teflon / PTFE I.V. Cannula with integrated 3 Way stop cock. Size 16G Should be packed in transparent, single blister pack.
Sterile Disposable (Single Use Teflon / PTFE I.V. Cannula with integrated 3 Way stop cock. ) Size 18G Should be packed in transparent, single blister pack.
Sterile Disposable (Single Use) Teflon / PTFE I.V. Cannula with integrated 3 Way stop cock. Size 20G Should be packed in transparent, single blister pack.
Sterile Disposable (Single Use) Teflon / PTFE I.V. Cannula with integrated 3 Way stop cock. Size 22G Should be packed in transparent, single blister pack.
Sterile Disposable (Single Use) Teflon/ PTFE I.V. Cannula without port. Size 24G Suitable for paediatric & neonatal use Should be packed in transparent, single blister pack. As per IS 10555 standard
Mucus Extractor Sterile Clear transparent container Antibacterial filter Soft, kink resistant PVC tubing Tube Size 10 FG; Length 40 cm (min.)
Nasal Oxygen Cannula (Set), Twin Bore (accessory for compressed air breathing) All Sizes (Adult) Soft and kink resistant PVC tubing Multichannel / star lumen to preventing accidental kinking Twin bores should ensure equal volume of oxygen to both air passages Connector for easy connection to the oxygen source
Nasal Oxygen Cannula (Set), Twin Bore (accessory for compressed air breathing) All Sizes (Pediatrics) Soft and kink resistant PVC tubing Multichannel / star lumen to preventing accidental kinking Twin bores should ensure equal volume of oxygen to both air passages Connector for easy connection to the oxygen source As per IS 12655 - 4 standard
ive Surgical Paper Tape (with cutter) Size 1" X 9.0 mts Breathable, Hypo-allergenic, Latex Free, Non-woven and micro- porous backing material. High quality water soluble adhesive for gentle bonding, holds well on damp skin and clean removal with minimal residue. Should conform to the Standard and test prescribed in applicable IS (14944) and
ive Surgical Paper Tape (with cutter) Size 2" X 9.0 mts Breathable, Hypo-allergenic, Latex Free, Non-woven and micro- porous backing material. High quality water soluble adhesive for gentle bonding, holds well on damp skin and clean removal with minimal residue. Should conform to the Standard and test prescribed in applicable IS (14944) and
ive Surgical Paper Tape (with cutter) Size 3" X 9.0 mts Breathable, Hypo-allergenic, Latex Free, Non-woven and micro- porous backing material. High quality water soluble adhesive for gentle bonding, holds well on damp skin and clean removal with minimal residue. Should conform to the Standard and test prescribed in applicable IS (14944) and
Plaster of Paris Bandages 15cm X 2.7mts / Roll Testing Parameter Should Be Followed As Per BP Standard
Plaster of Paris Bandages 10cm X 2.7mts / Roll Testing Parameter Should Be Followed As Per BP Standard
Ryle's Tube / Nasogastric Tube (P.V.C.) with radio opaque lining. Size: 10 Soft, kink resistant PVC tubing for atraumatic intubation Closed distal end should be coned with radio opaque material for accurate intubation Four lateral eyes for greater efficiency Radio opaque line Marking at 50, 60, 70 cm from tip Colour coded funnel With luer connector / closure
Ryle's Tube / Nasogastric Tube (P.V.C.) with radio opaque lining. Size: 12 Soft, kink resistant PVC tubing for atraumatic intubation Closed distal end should be coned with radio opaque material for accurate intubation Four lateral eyes for greater efficiency Radio opaque line Marking at 50, 60, 70 cm from tip Colour coded funnel Length 105 cm
Ryle's Tube / Nasogastric Tube (P.V.C.) with radio opaque lining. Size: 14 Soft, kink resistant PVC tubing for atraumatic intubation Closed distal end should be coned with radio opaque material for accurate intubation Four lateral eyes for greater efficiency Radio opaque line Marking at 50, 60, 70 cm from tip Colour coded funnel With luer connector / closure
Ryle's Tube / Nasogastric Tube (P.V.C.) with radio opaque lining. Size: 16 Soft, kink resistant PVC tubing for atraumatic intubation Closed distal end should be coned with radio opaque material for accurate intubation Four lateral eyes for greater efficiency Radio opaque line Marking at 50, 60, 70 cm from tip Colour coded funnel With luer connector / closure
Ryle's Tube / Nasogastric Tube (P.V.C.) with radio opaque lining. Size: 18 Soft, kink resistant PVC tubing for atraumatic intubation Closed distal end should be coned with radio opaque material for accurate intubation Four lateral eyes for greater efficiency Radio opaque line Marking at 50, 60, 70 cm from tip Colour coded funnel With luer connector / closure
Vein Set (Disposable): Size 18G Butterfly shaped wings for easy handling and attachment with skin. Colour coded Needle should be bevelled, siliconised and should ensure atraumatic cannulation Female luer fitting at one end Soft, kink resistant, non-toxic, non irritant tube Sterile
Vein Set (Disposable): Size 20G Butterfly shaped wings for easy handling and attachment with skin. Colour coded Needle should be bevelled, siliconised and should ensure atraumatic cannulation Female luer fitting at one end Soft, kink resistant, non-toxic, non irritant tube Sterile
Scalp Vein Set (Disposable): Size 22G Butterfly shaped wings for easy handling and attachment with skin. Colour coded Needle should be bevelled, siliconised and should ensure atraumatic cannulation Female luer fitting at one end Soft, kink resistant, non-toxic, non irritant tube
Scalp Vein Set (Disposable): Size 24G Butterfly shaped wings for easy handling and attachment with skin. Colour coded Needle should be bevelled, siliconised and should ensure atraumatic cannulation Female luer fitting at one end Soft, kink resistant, non-toxic, non irritant tube
Hypodermic Syringe with Needle attached, 24G, Single Use - 2 ml Clear transparent chamber Prominent graduation Inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow Sharp needle ensuring minimum trauma during penetration As per IS 12050 Packing: Needle should be attached with the syringe and packed in unit ribbon pack The words "DESTROY AFTER SINGLE USE" or equivalent should be written
Hypodermic Syringe with Needle attached, 24G, Single Use - 5 ml Clear transparent chamber Prominent graduation Inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow Sharp needle ensuring minimum trauma during penetration As per IS 12050 Packing: Needle should be attached with the syringe and packed in unit ribbon pack The words "DESTROY AFTER SINGLE USE" or equivalent should be written
Sterile Hypodermic Syringe with Needle attached, 22G, Single Use - 10 ml Clear transparent chamber Prominent graduation Inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow Sharp needle ensuring minimum trauma during penetration As per IS 12050 Packing: Needle should be attached with the syringe and packed in unit ribbon pack The words "DESTROY AFTER SINGLE USE" or equivalent should be written
Sterile Hypodermic Syringe with Needle attached, 22G, Single Use - 20 ml Clear transparent chamber Prominent graduation Inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow Sharp needle ensuring minimum trauma during penetration As per IS 12050 Packing: Needle should be attached with the syringe and packed in unit ribbon pack The words "DESTROY AFTER SINGLE USE" or equivalent
Surgical Blade Sterile, Size 11 Single peel pack in metal foil The tip of the blade shall be well defined, central and sharp. There shall be no waviness, jags, feathers, nicks, or other defects on the cutting edge. The surfaces of the blade shall be smooth and free from tool marks and any sign of corrosion. As per IS 3319
Surgical Blade Sterile, Size 15 Single peel pack in metal foil The tip of the blade shall be well defined, central and sharp. There shall be no waviness, jags, feathers, nicks, or other defects on the cutting edge. The surfaces of the blade shall be smooth and free from tool marks and any sign of corrosion. As per IS 3319
Surgical Blade Sterile, Size 22 Single peel pack in metal foil The tip of the blade shall be well defined, central and sharp. There shall be no waviness, jags, feathers, nicks, or other defects on the cutting edge. The surfaces of the blade shall be smooth and free from tool marks and any sign of corrosion. As per IS 3319
Sterile Disposable Spinal Needle for Single Use 22G x 3 ½ inch Clear / transparent hub
Sterile Disposable Spinal Needle for Single Use 25G x 3 ½ inch Clear / transparent hub
Urine Collecting Bag, Disposable 2000 ml Transparent sheet Kink resistant flexible tubing not less than 90 cm in length should have non-return valve Top drainage outlet Graduated bag
Double J Stent, Sterile, Both Ends Open - size 4F, length 16 cm Radio opaque Should be of inert material, non- irritant to tissue
Double J Stent, Sterile, Both Ends Open, size 5F, length 20 cm Radio opaque Should be of inert material, non- irritant to tissue
Double J Stent, Sterile, One End Closed - size 4F, length 16 cm Radio opaque Should be of inert material, non- irritant to tissue
Double J Stent, Sterile, One End Closed, size 5F, length 20 cm Radio opaque Should be of inert material, non- irritant to tissue
Endotracheal Tube, Plain - Size 2.5mm Transparent Standard 15 mm connector at proximal end Radio-opaque line throughout the length Tip suitable for nasal and oral intubation
Endotracheal Tube, Plain - Size 3mm Transparent Standard 15 mm connector at proximal end Radio-opaque line throughout the length Tip suitable for nasal and oral intubation
Endotracheal Tube, Plain - Size 3.5mm Transparent Standard 15 mm connector at proximal end Radio-opaque line throughout the length Tip suitable for nasal and oral intubation
Endotracheal Tube, Plain - Size 4mm Transparent Standard 15 mm connector at proximal end Radio-opaque line throughout the length Tip suitable for nasal and oral intubation Sharp tip which should ensure minimal puncture trauma
Endotracheal Tube, Plain - Size 4.5mm Transparent Standard 15 mm connector at proximal end Radio-opaque line throughout the length Tip suitable for nasal and oral intubation
Endotracheal Tube, Plain - Size 5mm Transparent Standard 15 mm connector at proximal end Radio-opaque line throughout the length Tip suitable for nasal and oral intubation
Endotracheal Tube, Plain - Size 5.5mm Transparent Standard 15 mm connector at proximal end Radio-opaque line throughout the length Tip suitable for nasal and oral intubation
Endotracheal Tube, Plain with radio-opaque line, Sterile, Single Use - Size 6mm Transparent Standard 15 mm connector at proximal end Radio-opaque line throughout the length Tip suitable for nasal and oral intubation Single use, sterile
Endotracheal Tube, Plain - Size 6.5mm Transparent Standard 15 mm connector at proximal end Radio-opaque line throughout the length Tip suitable for nasal and oral intubation
Endotracheal Tube, Plain - Size 7mm Transparent Standard 15 mm connector at proximal end Radio-opaque line throughout the length Tip suitable for nasal and oral intubation
Endotracheal Tube, Plain - Size 7.5mm Transparent Standard 15 mm connector at proximal end Radio-opaque line throughout the length Tip suitable for nasal and oral intubation
Endotracheal Tube, Plain - Size 8mm Transparent Standard 15 mm connector at proximal end Radio-opaque line throughout the length Tip suitable for nasal and oral intubation
Endotracheal Tube, Plain - Size 8.5mm Transparent Standard 15 mm connector at proximal end Radio-opaque line throughout the length Tip suitable for nasal and oral intubation
Endotracheal Tube, Cuffed - Size 4mm Soft cuff towards the distal end Kink resistant inflation tube Murphy eye at distal end with polished smoothness Radio-opaque line Standard 15 mm connector Sterile, single use
Endotracheal Tube, Cuff - Size 4.5mm Soft cuff towards the distal end Kink resistant inflation tube Murphy eye at distal end with polished smoothness Radio-opaque line Standard 15 mm connector Sterile, single use
Endotracheal Tube, Cuff - Size 5mm Soft cuff towards the distal end Kink resistant inflation tube Murphy eye at distal end with polished smoothness Standard 15 mm connector Sterile, single useCurved shaped blister pack – suiting the shape of product
Endotracheal Tube, Cuff - Size 6mm Soft cuff towards the distal end Kink resistant inflation tube Murphy eye at distal end with polished smoothness Radio-opaque line Standard 15 mm connector Sterile, single use
Endotracheal Tube, Cuff - Size 6.5mm Soft cuff towards the distal end Kink resistant inflation tube Murphy eye at distal end with polished smoothness Radio-opaque line Standard 15 mm connector Sterile, single use
Endotracheal Tube, Cuff - Size 7mm Soft cuff towards the distal end Kink resistant inflation tube Murphy eye at distal end with polished smoothness Radio-opaque line Standard 15 mm connector Sterile, single use
Endotracheal Tube, Cuff - Size 7.5 Soft cuff towards the distal end Kink resistant inflation tube Murphy eye at distal end with polished smoothness Radio-opaque line Standard 15 mm connector Sterile, single use
Endotracheal Tube, Cuff - Size 8 Soft cuff towards the distal end Kink resistant inflation tube Murphy eye at distal end with polished smoothness Radio-opaque line Standard 15 mm connector Sterile, single use
Endotracheal Tube, Cuff - Size 8.5 Soft cuff towards the distal end Kink resistant inflation tube Murphy eye at distal end with polished smoothness Radio-opaque line Standard 15 mm connector Sterile, single use
Endotracheal Tube, Cuff - Size 9 Soft cuff towards the distal end Kink resistant inflation tube Murphy eye at distal end with polished smoothness Radio-opaque line Standard 15 mm connector Sterile, single use
Tracheostomy Tube (PVC), Plain, Sterile, Single Use - All Sizes Soft flexible flange at for easy fixation 15 mm connector at terminal end which can be rotated in 360 degree direction Non-irritant Radio-opaque line
Tracheostomy Tube (PVC), Cuffed, Sterile, Single Use - All Sizes Soft flexible flange at for easy fixation 15 mm connector at terminal end which can be rotated in 360 degree direction Non-irritant Radio-opaque line Balloon with non return valve
Abdominal Drain Kit, Sterile, Having drainage catheter and Collection Bag (2000 ml) (size 24) Graduated Bag Should have well fitting cap Soft drainage catheter 50 cm long, with radio opaque line Rounded open distal end with smooth atraumatic eyes in catheter
Abdominal Drain Kit, Sterile, Having drainage catheter and Collection Bag (2000 ml) (size 28) Graduated Bag Should have well fitting cap Soft drainage catheter 50 cm long, with radio opaque line Rounded open distal end with smooth atraumatic eyes in catheter
Abdominal Drain Kit, Sterile, Having drainage catheter and Collection Bag (2000 ml) (size 32) Graduated Bag Should have well fitting cap Soft drainage catheter 50 cm long, with radio opaque line Rounded open distal end with smooth atraumatic eyes in catheter
Polypropylene Nonabsorbable Synthetic Surgical Mesh 7.5 cmX 15 cm soft to feel fast edges,slightly stretchbonding.
Polypropylene Nonabsorbable Synthetic Surgical Mesh 15 cmX 15 cm soft to feel fast edges,slightly stretchbonding.
Sterilized Umbilical Cotton Tape Width 3 mm, Length 75 cm Should conform to Schedule F(III) of Drug and Cosmetic Act 1940
Bone Wax Sterilised
Skin Graft Knife Blade (Sterile) (disposable ) Skin Grafting Knife Blade (Sterile) made of carbon steel or stainless steel material 158 mm long individually wrapped in wrapper corrosion inhibitor paper in single packet,. In packs of 10. The edge must be sharp enough to cut the skin in a single shave and should snugly fit in the handle As per IS IS 3759.
K Wire, length 375 mm; 1mm Length of wire should be mentioned with specification. As per IS 8261
K Wire, length 375 mm;1.6mm Length of wire should be mentioned with specification.
K Wire, length 375 mm; size 1.8mm Length of wire should be mentioned with specification. As per IS 8261
Face Mask, Disposable • Should be manufactured from non woven poly prop fabric • Should be 3 ply construction • Should have high bacterial filtration efficiency • Should be heat sealed to keep 3 layers together • Standard size 17.5 x9 cm • Color green/blue • There should be a string each at all four corners,length of string should be 40cm • Nose clip should be there
Surgical Cap, Disposable (For Surgeons) Should be manufactured from non woven fabric. Strip for tying the cap stitched on the back for proper grip on the forhead. Green colour Ultrasonically stitched Air permeable/breathable Should retain skin and hair particle.
Surgical Cap, Disposable ( For Nurses) Should be manufactured from non woven fabric Blue / Green colour Round upon wearing, with elastic Air permeable / breathable
Foldable Intra Ocular lense with injector (Size + 11 D to +17.5 D) Size:6mm optics. 12-13mm total diameter 1. Made of foldable Acrylic (Hydrophobic) material 2. Bi-Convex single piece IOL with aspheric optics 3. Size:6mm optics. 12-13mm total diameter. 4. Modified C loop haptic/plate haptics ( 5. IOL should have UV blocking capability 6. IOL should have 360°square edge.. 7. foldable and insertion by injector with disposable cartridge As per IS 8261insertable by a sub 2.8 mm incision size or smaller incision 8. Diopters- + 11 D to +17.5 D at 0.5 D step. 9. Supplying unit should be ISO accredited and IOL should be CE/US FDA certified.
Foldable Intra Ocular lense with injector (Size + 18 D to + 24 D) Size:6mm optics. 12-13mm total diameter 1. Made of foldable Acrylic (Hydrophobic) material 2. Bi-Convex single piece IOL with aspheric optics 3. Size:6mm optics. 12-13mm total diameter. 4. Modified C loop haptic/plate haptics 5. IOL should have UV blocking capability 6. IOL should have 360°square edge.. 7. foldable and insertion by injector with disposable cartridge insertable by a sub 2.8 mm incision size or smaller incision 8. Diopters- + 18 D to + 24 D at 0.5 D step. 9. Supplying unit should be ISO accredited and IOL should be CE/US FDA certified.
Foldable Intra Ocular lense with injector (Size + 24.5 D to + 28.5 D ) Size:6mm optics. 12-13mm total diameter 1. Made of foldable Acrylic (Hydrophobic) material 2. Bi-Convex single piece IOL with aspheric optics 3. Size:6mm optics. 12-13mm total diameter. 4. Modified C loop haptic/plate haptics 5. IOL should have UV blocking capability 6. IOL should have 360°square edge.. 7. foldable and insertion by injector with disposable cartridge insertable by a sub 2.8 mm incision size or smaller incision 8. Diopters- + 24.5 D to + 28.5 D at 0.5 D step. 9. Supplying unit should be ISO accredited and IOL should be CE/US FDA
Standard PMMA Intra Ocular Lenses (Size + 11 D to +17.5 D) • 6mm optic size 12.5 - 13.0 mm total diameter, Biconvex 1. PMMA optics and haptics single piece with hole 2. 6mm optic size 12.5 to 13mm total diameter, Biconvex 3. IOL haptics – modified C shaped with 5° -10° anterior angulation. 4. Should have 360° square edges. 5. IOL should have UV blocking capability 6. Diopters- + 11 D to +17.5 D at 0.5 D step. 7. Supplying unit should be ISO accredited and IOL should be CE/US FDA certified.
Standard PMMA Intra Ocular Lenses (Size + 18 D to + 24 D) 6mm optic size 12.5 - 13.0 mm total diameter, Biconvex A optics and haptics single piece with hole optic size 12.5 to 13mm total diameter, Biconvex haptics – modified C shaped with 5° -10° anterior angulation. d have 360° square edges. should have UV blocking capability 6. Diopters- + 18 D to + 24 D at 0.5 D step. plying unit should be ISO accredited and IOL should be CE/US FDA certified.
Standard PMMA Intra Ocular Lenses (Size + 24.5 D to + 28.5 D ) 6mm optic size 12.5 - 13.0 mm total diameter, Biconvex 1. PMMA optics and haptics single piece with hole 2. 6mm optic size 12.5 to 13mm total diameter, Bioconvex 3. IOL haptics – modified C shaped with 5° -10° anterior angulation. 4. Should have 360° square edges. 5. IOL should have UV blocking capability 6. Diopters- + 24.5 D to + 28.5 D at 0.5 D step. 7. Supplying unit should be ISO accredited and IOL should be CE/US FDA certified.certified.
Disposable Sterile Surgical Rubber Gloves Size 8 Inches made of natural rubber latex powdered,without tear,properly folded in a paper As per IS 13422 ISI marked/CE certified/FDA approved Colour code marking to designate size
Disposable Sterile Surgical Rubber Gloves Size 8 Inches made of natural rubber latex powder free,without tear,properly folded in a paper As per IS 13422 ISI marked/CE certified/FDA approved Colour code marking to designate size
Rubber examination gloves made of natural rubber latex. Non-sterile, Ambidextous, AQL 1.5 Micro Textured Powdered with absorbable dusting powder USP. Extra Small. Should bear BIS certificate of IS 15354 CE marked/ISO 13485 (for importer)
Rubber examination gloves made of natural rubber latex. Non-sterile, Ambidextous, AQL 1.5 Micro Textured Powdered with absorbable dusting powder USP. Small Should bear BIS certificate of IS 15354 CE marked/ ISO 13485 (for importer)
Rubber examination gloves made of natural rubber latex. Non-sterile, Ambidextous, AQL 1.5 Micro Textured Powdered with absorbable dusting powder USP. Medium Should bear BIS certificate of IS 15354 CE marked /ISO 13485 (for importer)
Rubber examination gloves made of natural rubber latex. Non-sterile, Ambidextous, AQL 1.5 Micro Textured Powdered with absorbable dusting powder USP. Large Should bear BIS certificate of IS 15354 CE marked/ ISO 13485 (for importer)
Pressure Monitoring Line / High Pressure Extension Line Suitable for high pressure monitoring and for connection between syringe infusion pump and patient Male luer lock at one end and female luer lock at other end ; should fit all standard equipment. Luer lock connectors should provide secure fitting. Pressure upto 800 psi Length 200 cm
Urine Collecting Bag for new born / Paediatric urine collecting Bag Should have suitability for both male and female patients Should be provided with adhesive for fixation and good grip with minimal risk of allergy and injury Capacity 100 ml
Umbilical Catheter (for New Born) All sizes Radio opaque line With female flexible mount Colour coded connector Open tip should be soft, rounded, atraumatic
Umbilical Cord Clamp Suitable for clamping umbilical cord of new born Security lock to prevent accidental opening after clamping
Absorbable Oxidized Regenerated Cellulose net size 2”x 3” Topical Absorbable Haemostatic Bactericidal Property
Close wound Drainage Device under negative pressure (Closed Wound Suction Unit) Option to use one or two catheters simultaneously Bellow chamber with capacity 800 ml Bellow unit with connector Graduated Bellow Connecting tube with clamp and “Y”connector Curved needle / trocar with catheter Multiperforated catheter / Radon drain with radio opaque line Catheter 16 FG
Close wound Drainage Device under negative pressure (Closed Wound Suction Unit) Option to use one or two catheters simultaneously Bellow chamber with capacity 800 ml Bellow unit with connector Graduated Bellow Connecting tube with clamp and “Y”connector Curved needle / trocar with catheter Multiperforated catheter / Radon drain with radio opaque line Catheter 18 FG
Bone cement with antibiotics,fast and slow setting
Sanitary Napkins (for Menstrual Hygiene) Specifications:- Sanitary Napkin consists of an outer covering provided with sufficient number of channels for leak protection and an absorbent filler material. The Sanitary Napkins shall have a soft feel and when worn shall not chafe or give any uncomfortable feeling. Should be odourless. The material used in fabrication shall be non allergenic. Shall be free from acids and alkali. Each primary package shall contain 6 napkins in a polyethylene bag of good quality which As per IS size of product and sealed properly. Both upper and lower sheets shall be white in colour. As per IS 5405.
Sanitary Napkin, Beltless1. Covering – Covering of the absorbent filler shall be good quality knitted sleeve or non-woven fabric which has sufficient porosity to permit the assembled napkin to meet the absorbency requirements. The napkins shall have a non absorbent barrier on one side which shall have an identifying mark indicating the side of the barrier. 2. Absorbent Filler – The filler material shall consist of cellulose pulp/ wadding, and shall be free from lumps, oil spots, dirt or foreign material, etc. 3. Back Strip – A back strip for sticking the sanitary napkin onto the underwear should be there using good quality adhesive material. 4. Size - The size of absorbent section / complete sanitary napkin shall be as follows: ( in mm) Absorbent section Total Pad Length 210 +_ 10 230 +_ 10 Width 60 to 75 70 to 85 Thickness 8 +_ 2 5. Weight : Not more than 10 gm . . Instruction for usage should be mentioned on every packet Instruction for usage should be mentioned on every packet (B). Disposable Individual Pouch/Wrapper for Each Sanitary Napkin (as per notification of Ministry of Environment, Forest and Climate Change Dated 08.04.2016) Pouch/Wrapper Specifications:- 1- Pouch/wrapper should be of the size of Sanitary Napkin being supplied. 2- It should have adhesive to seal the sanitary napkin within. 3- Pouch/Wrapper should not be transparent. Instruction for use of disposable pouch/wrapper must be written in Hindi on disposable pouch/wrapper - “bLrseky fd;s gq;s lsusVjh usifdu dks eksM dj Disposable Pouch/Wrapper esa Mkys ,oa Pouch/Wrapper dks xksan yxh iV~Vh ls cUn dj lqjf{kr rjhds ls dwMsnku esa MkysaA ”
Sanitary Napkin, Belttype 1. Covering – Covering of the absorbent filler shall be good quality knittedsleeve or non-woven fabric which has sufficient porosity to permit the assembled napkin to meet the absorbency requirements. The napkins shall have a non absorbent barrier on one side which shall have an identifying mark indicating the side of the barrier. 2. Absorbent Filler – The filler material shall consist of cellulose pulp/ wadding, and shall be free from lumps, oil spots, dirt or foreign material, etc 3. Size - The size of absorbent section / complete sanitary napkin shall be as follows: ( in mm) Absorbent section Absorbing Pad Length 220 +_ 10(overall pad length 550+-10mm) with absorbing pad lying in the center Width 70 +_ 5 Thickness 17 +_ 3 4. Weight : 12 +_ 3 gm 5. Pack – Six napkins in a pack. 6. Elastic Belt with loops shall be provided in each pack. 7. Absorbency: The napkin should be able to absorb not less than 30 ml of normal saline or coloured water or test fluid when poured on to the centre of the napkin at the rate of 15
Name of Item- Belt-less Sanitary Napkin with wings 1. Covering (Absorbing top sheet character)–Good Quality knitted sleeve or non woven fabric of rash free, non irritant and soft to touch material which has sufficient porosity to permit the assembled napkin to meet absorbency requirements. The napkins shall have a non absorbent barrier on one side with adhesive covered by a differently identifiable paper 2.Overall Length (mm) 230 ± 5 3.Core length 220 mm± 10 4.Fluff core/pad length 220 mm± 10 5. Over all width with wings 160mm+_5 6.Fluff core/pad length 70 mm± 5 7.Thickness of a single pad 9-10mm 8. Weight of a single pad : 8-10 gm 9. Pack Six napkins in a pack. 10 Type.- Belt-less Sanitary Napkin with wings 11. Minimum Absorbency: 50ml 12.pH value of absorbent material 6-8.5 B. DISPOSABLE Individual pouch for each sanitary napkin(as per notification of ministry of environment, forest and climate change dated 08.04.2016) Pouch specifications:- 1. Pouch should be of the size of sanitary napkin being supplied. 2. It should have adhesive to seal the sanitary napkin within. 3. Pouch should not be transparent. Note:-Instructions for use of disposable pouch must be written in Hindi on disposable pouch. bLrsrky fd;s gq;s lsusVjh usifdu dks eksM dj Disposable Pouch esa Mkys ,oa Disposable Pouch dks xksan yxh iV~Vh ls cUn dj lqjf{kr rjhds ls dwMsnku esa MkysaA
mask (Adult) Mould Facemask with adjustable elastic strap for proper position of mask on the mouth and nasal area Friendly soft medical PVC material fitting better and more comfortable. Aluminium nasal clip provides better fixation. Anatomical design provides lighter seal. Latex free elastic strap available.
Oxygen mask (Paediatric) Mould Facemask with adjustable elastic strap for proper position of mask on the mouth and nasal area Friendly soft medical PVC material fitting better and more comfortable. Aluminium nasal clip provides better fixation. Anatomical design provides lighter seal. Latex free elastic strap available. Mask connector 4M
Catheter, single Use, for Urinary Drainage(Foley Balloon Catheter), 2 way, Size 14 Made of Silicone elastomer bonded with Latex Should have hard plastic valve Smooth distal end with smooth eyes for a traumatic intubation Symmetrical Foley Balloon Balloon Capacity 30+-1 ml As per IS 11497 Color coding marking to identify size Length, wall thickness and ballon capacity should be mentioned as per IS 11497 Specification for B,C,D,E,F,G should be mentioned as per IS 11497
Nelaton catherer size14FG al end is close and proximal end has female colour code connector Soft, Kink resistant medical grade PVC tube Length:40 cm
ECG Electrode •Reliable trace, •High conductivity,• Easy to handle
Surgical Blade Sterile, Size 23 • Single peel pack in metal foil • The tip of the blade shall be well defined, central and sharp. There shall be no waviness, jags, feathers, nicks, or other defects on the cutting edge. The surfaces of the blade shall be smooth and free from tool marks and any sign of corrosion.
Sterile Hypodermic Syringe with Needle attached, 22G, Single Use - 50 ml • Clear transparent chamber • Prominent graduation • Inert material gasket at the piston to minimise friction during movement • Sharp needle ensuring minimum trauma during penetration • As per (phle Shall conform to tha )IS 12050 • Packing: Needle should be attached with the syringe and packed in unit ribbon pack • The words "DESTROY AFTER SINGLE USE" or equivalent should be
Urethral Catheter 90 (FG-14), made up of medical grade PVC
Urethral Catheter 91 (FG-10), made up of medical grade PVC
Vaccum Suction Set, 2.5 meter Length, •Suction handle with Suction Tube •Sterile,• Pyrogenic Free, •Latex free,• Single use & prevent leakage and back flow
Epidural Minipack 18G, 80mm – 90mm, Metal Stylet For Single Use only, •Sterile, •Epidural catheter 20G, L 90 cm, • 3 to 6 Lateral Holes closed end, •Borst Adapter •Epidural Catheter Flat filter 0.2 micro meter •Thread Assist Guide
Vascular Catheter 16G/5FR, double lumen length 40cm.USFDA/ four digit notified CE approved, should have two guide wire 45cm & 80cm or more (Logline IV.) Peel-Away Sheath Glide Thru 5fr*10 cm, Guide wire Nitinol 80 cm, Guide wire Nitinol 45 cm Introducer Needle 21 G *7 CM, Syringe - 10 ml tuer-lock, Skin Protectant Prep Pad, second site Adjustable Hub, Measuring Tape, 5 fr pressure Injectable PICC Line with blue flex tip 40 cm, Dressing STATLOOCK stabilization Device (Suture less)
Vascular Catheter with metal Guide wire, 4Fr Single Lumen, distalvalve, saline flush only Size 45cm or more USFDA/ four digit notified CE approved (Logline IV.) Internal stylet, Statlock Stabilization device (Suture less), Introducer Needle, Micro introducer with Vessel Dilator, Guide wire- 50 Cm Nitinol, Safety Scalpel,Suture Wing, End Cap
Vascular Catheter with metal Guide wire 3Fr single lumen,micro introducer,contrast Media compatible, Size 45cm or more (Logline IV.) USFDA/ four digit notified CE approved Syringe 12 ml,Internal stylet,Measuring Tape,Stat lock catheter Stabilization device (Suture less), Introducer safety peripheral IV catheter 20G, Micro introducer with Vessel Dilator,Guide wire-50 Cm Nitinol,Needle introducer 21 G, Safety Scalpel, End Cap
Vascular Catheter 7FR-16 CM with chlorhexidine, silver sulfadiazine coated triple lumen USFDA/four digit notified CE approved. Introducer Needle 18 G., spring guide wire 45 cm J tip, Dilator 8.5 Fr., Raulerson spring Introduction syringe 5 ml
Vascular Catheter 5Fr/16G, double lumen length 50cm.USFDA/four digit notified CE approved. should have two guide wire 45 cm & 80cm or more(Logline IV.) Peel-Away Sheath Glide Thru 5fr *10 cm, Guide wire Nitinol 80 cm, Guide wire Nitinol 45 cm, Introducer Needle 21 G *7 CM, Syringe-10 ml luer-lock, Skin Protectant Prep Pad, second site Adjustable Hub, Measuring Tape,5 fr pressure Injectable PICC Line with blue flex tip 50 cm, Dressing STATLOOCK stabilization Device (Suture less)
Vascular Catheter 5fr/16G, double lumen length 55cm.USFDA/ four digit notified CE approved, should have two Guide wire 45cm & 80cm or more (Logline IV.) Peel-Away Sheath Glide Thru 5fr *10 cm,Guide wire Nitinol 80 cm,Guide wire Nitinol 45 cm,Introducer Needle 21 G*7 CM, Syringe- 10 ml luer-lock, Skin Protectant Prep Pad, second site Adjustable Hub, Measuring Tape,5 fr pressure Injectable PICC Line with blue flex tip 55cm, Dressing STATLOOCK stabilization Device (Suture less)
Vascular Catheter with metal Guide wire 5Fr Double lumen, Introducer safety PIV Catheter20G, 45cm or more (Logline IV.) USFDA/ four digit notified CE approved Syringe 12 ml, Internal stylet, Measuring Tape, Stat lock catheter Stabilization device (Suture less), Introducer safety peripheral IV catheter 20G,Micro introducer with Vessel Dilator,Guide wire-50 Cm Nitinol,Needle Introducer 21 G,Safety Scalpel, End Cap
Vascular Catheter with Metal Guide wire,5Fr Triple Lumen, Size range 55cm or more (Logline IV:) USFDA/four digit notified CE approved Syringe 12 ml, Internal stylet, Measuring Tape, Stat lock catheter Stabilization device (Suture less), Introducer safety peripheral IV catheter 20G,Micro Introducer with Vessel Dilator, Guide wire-50 Cm Nitinol, Needle Introducer 21 G, Safety Scalpel,End Cap
3 Way Stop Cock , Non Pyrogenic & Single Use, should be leak proof, with smooth movements
3 Way Stop Cock with extension Tube (Vein-O Extension line) size 10 cm (Non Pyrogenic & Single Use)
3 Way Stop Cock with extension Tube (Vein-O Extension line) size 50 cm (Non Pyrogenic & Single Use)
3 Way Stop Cock with extension Tube (Vein-O Extension line) size 100 cm (Non Pyrogenic & Single Use)
3 Way Stop Cock with extension Tube (Vein-O Extension line size 150 cm (Non Pyrogenic & Single Use)
Abdominal Drain Kit, Sterile, having drainage catheter and Collection Bag (2000 ml) (size 16) • Graduated Bag, • Should have well fitting cap • Soft drainage catheter 50 cm long, with radio opaque line • Rounded open distal end with smooth atraumatic eyes in catheter
Abdominal Drain Kit, Sterile, having drainage catheter and Collection Bag (2000 ml) (size 20) • Graduated Bag • Should have well fitting cap • Soft drainage catheter 50 cm long, with radio opaque line • Rounded open distal end with smooth atraumatic eyes in catheter
Nasal Pronge Neonatal (Flexible Medical Grade, 2 Meter Long, Multichannel Kink Resistance Tube
Elastic Adhesive Bandage BP 10 cm x 1 mtr Stretched Length Adhesive material should have good quality sticking property, non-allergic
Sterile Disposable (Single Use Teflon/PTFE I.V Cannula with integrated 3 way stop cock Size 26G · Should be packed in transparent single blister pack · Should confirm to IS 10555 standard
NIV Mask (Noninvasive Ventilation Mask) Adult · Should be light weight silicon based full face & nasal mask with face & forehead soft cushion pads should have variable pressure inflatable cushion for adults in Large size. Should be with ergonomically designed clips/straps for easy disengagement of the head gear. Should be Single Use for Ventilator without vent. Non allergic, leak proof, contour should be
NIV Mask (Noninvasive Ventilation Mask) Adult • Should be light weight silicon based full face & nasal mask with face &forehead soft cushion pads should have variable pressure inflatable cushion for adults in Large size. Should be with ergonomically designed clips/straps for easy disengagement of the head gear. Should be Single Use for BiPAP with vent.Non allergic, leak proof, contour should be maintained.
NIV Mask (Noninvasive Ventilation Mask) Adult · Should be light weight silicon based full face & nasal mask with face &forehead soft cushion pads should have variable pressure inflatable cushion for adults in Large size.Should be with ergonomically designed clips/straps for easy disengagement of the head gear. Should be Single Use for BiPAP with vent.Non allergic, leak proof, contour should be maintained.
NIV Mask (Noninvasive Ventilation Mask) Adult • Should be light weight silicon based full face & nasal mask with face &forehead soft cushion pads should have variable pressure inflatable cushion for adults in Medium size.Should be with ergonomically designed clips/straps for easy disengagement of the head gear. Should be Single Use for BiPAP with vent. Non allergic, leak proof, contour should be maintained.
NIV Mask (Noninvasive Ventilation Mask) Paediatric • Should be light weight oro nasal mask with soft cushion pads in small size • Should be with ergonomically designed clips/straps for easy disengagement of head gear • Should be Single Use with Bronchoscopy port CO2 &O2 port with chin support
1. Compatibile with any standard Nebulizer/high/flow oxygen. 2. Made of transparent ,soft,clear,non-toxic, non-irritant , latex free material. 3. Storage Humidity Range = 90%RH 4. Soft, kink resistant minimum 2 meter long non- collapsible extension on tubing to be connected with Nebulizer/oxygen source. 5. Consist of Adult (Large) Mask with pull through elastic strip to hold in place . 6. Anatomically contoured for comfort /nose clip on mask preferable. 7. Should have leak/spillage proof nebulizer chamber. 8. The mask nebulizer chamber and tubing should be sterilizable . 9. Should with stand gas flow of at least 10ltr/min. 10.Particles sizes should be below 5 microns if used with oxygen or nebulizer 11. Nebulizes 3cc within 10 minutes.
1. Compatibile with any standard Nebulizer/high/flow oxygen. 2. Made of transparent ,soft,clear,non-toxic, non-irritant , latex free material. 3. Storage Humidity Range = 90%RH 4. Soft, kink resistant minimum 2 meter long non- collapsible extension on tubing to be connected with Nebulizer/oxygen source. 5. Consist of Paediatric Mask with pull through elastic strip to hold in place. 6. Anatomically contoured for comfort /nose clip on mask preferable. 7. Should have leak/spillage proof nebulizer chamber. 8. The mask nebulizer chamber and tubing should be sterilizable . 9. Should with stand gas flow of at least 10ltr/min. 10.Particles sizes should be below 5 microns if used with oxygen or nebulizer 11. Nebulizes 3cc within 10 minutes.
Chemotherapy Port &Non-coring needles(Adult) • Valved catheter need only saline flush, catheter with intermediate size port with small septum and silicon filled suture holes, should be MRI compatible with cathlock radio- opaque ring. 8FR with silicon material with peel apart percutaneous introducer system. • Chemo port huber needle 20g and 22g.
Chemotherapy Port &Non-coring needles(Pediatric) • catheter need only saline flush, catheter with intermediate size power port with large septum and silicon filled suture holes, should be MRI compatible with cathlock radio- opaque ring. 6FR with silicon material with peel apart percutaneous introducer system • Chemo port huber needle 20g and 22g.
Core biopsy instrument with compatible co-axial needle (Automatic disposal ) Should be bevel tip.Should have adjustable penetration depth of 18mm and 25 mm with automatic and semi-automatic firing modes in single instrument/gun. Should have fire ready indicator to reduce the risk of premature instrument firing.Should have advanced Echogenic Technology for enhanced visibility in ultrasound. Should be available with compatible coaxial needle in a single kit. Instrument / Gun Size: 18 Gauge, 16cm with Coaxial Needle Size: 17
Disposable bone marrow biopsy needle Should have ergonomic two- piece T-handle design. Should have trocar tapered stylet point for easy coring of bone.Should have triple crown cannula tip with 6 cutting cannula facets.Should be available with marrow acquisition cradle with sample size verification marking. 11Gauge, 4 inch Length
Eyelid occlusion dressing Should have width of 3.5 to 4.0 cm & Length of 9.5 to 10.0cm, Dual Zonel with Central Zone as Transparent window, Material-100% polyurethane Clear Film layer, Made up of Polyester Non-Woven Fabric, Latex Free, Solvent based Acrylic adhesive, A set of 2 sterile dressing , CE Certified.
Eye pressure shield Should be made up of Soft Foam and Rigid Plastic Shield, Length of 178 to 185 mm and width of 83 to 88mm, Foam Thickness of 17 to 19mm. Plastic Type Triton TX-2001, Enough holes on Nasal rib and either side of the shield to prevent condensation, Weight
Belt-less Sanitary Napkin with wings 1. Covering (Absorbing top sheet charactor)–Good Quality knitted sleeve or non woven fabric of rash free, non irritant and soft to touch material which has sufficient porosity to permit the assembled napkin to meet absorbency requirements. The napkins shall have a non absorbent barrier on one side with adhesive covered by a differently identifiable paper 2.Overall Length (mm) 280 ± 5 3.Core length 265 mm± 5 4.Fluff core pad length 265 mm± 5 5. Overall width with wings (mm) 160mm+_5 6.Thickness of a single pad (mm) 9-10mm 7. Weight of a single pad : 8-10 gm 8. Pack Six napkins in a pack. 9 Type.- Belt-less Sanitary Napkin with wings 10. Minimum Absorbency: 50ml 11.pH value of absorbent material 6-8.5 12. DISPOSABLE Individual pouch for each sanitary napkin(as per norms ministry of environment, forest and climate change dated 08.04.2016) Pouch specifications:- 1. Pouch should be of the size of sanitary napkin being supplied. 2. It should have adhesive to seal the sanitary napkin within. 3. Pouch should not be transparent. 4.It should have UDAAN logo on the sanitary napkin packet. 5.Instruction for use of disposable pouch must be written in Hindi. Note:-Instructions for use of disposable pouch must be written in Hindi on disposable pouch . bLrseky fd;s gq;s lsusVjh usifdu dks eksM dj Disposable Pouch esa Mkys ,oa Disposable Pouch dks xksan yxh iV~Vh ls cUn dj lqjf{kr rjhds ls dwMsnku esa MkysaA
Qunituple Penta Blood Bag 450 ml CPDA
Qunituple Penta Blood Bag 350 ml CPDA
Single Blood Bags {350ml)
Double Blood Bags with SAGM (350ml)
Double Blood Bags with SAGM (450ml)
Triple Blood Bags with SAGM (350ml)
Triple Blood Bags with SAGM (450ml)
Quadruple Blood Bags with SAGM (350ml)
Quadruple Blood Bags with SAGM (450ml)
Specifications of Bed side Leucodepletion Filters for Blood Transfusion:-( For one unit of red cell) 1. Filters should be able to leuco-deplete red cells form leukocyte contamination separately for 1 unit of red cells. 2. Filters should be having the capacity of log 4 reduction (99.99%) 3. Filters should not carry any charges it should be neutrally charged. 4. Filters material should be polyester woven / non- woven. 5. Leukocytes should be consistently averaging less than 0.5x105 residual leucocytes for one unit of red cell. RBC recovery should be averaging more than 90%. 6. Filters should have hard / soft housing for optical monitoring. 7. Filtration loss should not be more than 35 ml for one unit red cell. 8. Should have integrated ≥ 40 µm, micro aggregate filter. 9. Should be US FDA/ European CE Certified. 10. Filter should have air vent, to achieve transfusion with minimum loss. 11. Packing Unit – Filter should have individual packing with bulk box pack. Quantity
Specifications of Bed side Leucodepletion Filters for Blood Transfusion:-(For two unit of red cell ) 1. Filters should be able to leuco-deplete red cells form leukocyte contamination separately for 1 unit of red cells and for 2 units of red cells each. 2. Filters should be having the capacity of log 4 reduction (99.99%) 3. Filters should not carry any charges it should be neutrally charged. 4. Filters material should be polyester woven / non- woven. 5. Leukocytes should be consistently averaging less than 0.5x105 residual leucocytes for one unit of red cell and 0.2*106 for two units of red cell. RBC recovery should be averaging more than 90%. 6. Filters should have hard / soft housing for optical monitoring. 7. Filtration loss should not be more than 35 ml for one unit red cell. 8. Should have integrated ≥ 40 µm, micro aggregate filter. 9. Should be US FDA/ European CE Certified.
HIV (ELISA) testing kits IV generation. 1. Should be solid phase micro plate coated HIV I & II recombinant and/or synthetic peptide antigens and antibody to HIV 1 p24. 2. The assay should detect HIV 1 and II antibodies and HIV 1p24 antigen. 3. Micro wells coated with a mixture of recombinant HIV antigens gp120, gp41 and gp36 & monoclonal antibodies to HIV p24 antigen. 4. Analytical sensitivity of p24 Ag should not be less than 20 pg/ml. 5. Adequate documents detailing the principle, components, details of antigen for antibody, detection of HIV 1 and 2 Antigen, bio- safety, methodologies validity, criteria interpretation of results, performance characteristics, storage conditions, limitation of assays manufacturing, & expiry dates should be provided with each kit. 6. The kit should have approval of the statutory authority in its country of origin. 7. In case of imported kits it should be registered and licensed under the provisions of Drugs & cosmetics Act and rules/ or Medical devices rules 2017 in India. 8 In case of indigenous manufacturers should be licensed under the provisions of Drugs & cosmetics, Act and rules and or medical devices rules 2017 issued by the competent authority defined under Drugs and Cosmetics Act, 1940, 9. The kit should have minimum remaining shelf- life of 5/6" or 12 months {Whichever is more) the port of discharge of consignees, 10. The assay component should include reactive (for both antibody as well as antigen) and non- reactive controls with each kit. 11. The assay should have sensitivity level of 100% and specificity level of more than or equal to 99%. 12. The manufacturer should ensure maintenance of cold chain during storage & transport the kits at 2°c - 8°C. The temperature indicator should be placed on every pack of kit. 13. The pack size should be 96 tests/kit.
Hepatitis B Surface Antigen (Elisa) Testing Kits IV Generation/High sensitive 1. An ELISA reader based qualitative test 2. Should have polyclonal antibodies coated on the solid. phase & monoclonal antibodies in the conjugate to detect all subtypes & mutant strains. The assay should be able to detect surface antigen to hepatitis B virus. 3. Total incubation time should not be more than 90 minutes. 4. Adequate documents detailing the principle components, bio- safety methodologies, validity criteria, interpretation of results, performance characteristics storage conditions, limitation of assays manufacturing & expiry dates should be provides with each kit. 5. The kit should have approval of the statutory authority in its country of origin. 6. In case of imported kits it should be registered and licensed under the provisions of Drugs & Cosmetics act and rules and/or medical devices rules 2017 in India, 7. In case of indigenous manufacturers should be licensed under the provisions of Drugs & cosmetics Act and rules and or medical devices rules 2017 issued by the competent authority defined under Drugs and cosmetics act, 1940. 8. The kit should have minimum shelf- life of 5/61h or 12 months (whichever is more) at the port of discharge of consignees. 9. The assay component should include reactive and non- reactive controls. 10. The assay should have sensitivity of 100% and specificity of more than or equal to 99% 11. The assay should have analytical sensitivity of detecting less than or equal to 50pg/ml. 12. All the reagents should in ready to use form. Only wash buffer concentrate to be reconstituted before use. The manufacturer should ensure maintenance of cold chain during storage & transport the kits at 2°c - 8°C. Temperature indicator to be placed on every box of kits. 13. The kit size should be 96 tests/kit.
HCV (Elisa) Testing Kits IV Generation 1. Microplate ELISA coated with recombinant/ synthetic peptide antigens for core. NS3 NS4 and NSS and antibody to HCV core Antigen. 2. Should be based on Indirect Assay for Antibody detection & Sandwich for Antigen detection. 3. Total Incubation time should not be more than 150 minutes. 4. Positive & negative controls for antigen & antibody should be ready to use. 5. Adequate documents detailing the principle, components, bio- safety methodologies validity criteria, interpretation of results, performance characteristics, storage conditions, limitation of assays manufacturing & expiry dates should be provided with each kit. 6. The kit to be procured should have approval of the statutory authority in its country of origin. 7. In case of imported kits it should be registered and licensed under the provisions of Drugs cosmetics Act and rules and/or medical devices rules 2017 in India. 8. In case of indigenous manufacturers should be licensed under the provisions of Drugs &cosmetics Act and rules and or medical devices rules 2017 issued by the competent authority defined under Drugs and cosmetics act 1940. 9. The kit should have minimum shelf- life of 5/61hor 12 months (whichever is more) at the port of discharge of consignees. 10. The assay component should include reactive (for both antibody and antigen) and non- reactive controls. 11. The assay should have a sensitivity of 100% and specificity of more than or equal to 98%. 12. The manufacturer should ensure maintenance of cold chain during storage & transport the kits at 2°c - 8°c. The time temperature indicator should be placed on every pack of kits. 13. The pack size should be 96 tests/kit.
HIV (Rapid) testing kits 1. Test should be a solid coated HIV 1 & HIV II recombinant and/or synthetic peptide antigens. 2. The assay/test assay should detect total antibodies (lgG, lgM & lgA) specific to HIV-1 & HIV-2 in human serum, plasma & whole blood. 3. The assay should utilize recombinant HIV-1 capture antigens i.e. gp41 and gp120) for detection of HIV 1 antibodies & recombinant HIV-2 capture antigen i.e. gp36 detection of HIV 2 antibodies. 4. Adequate documents detailing the principle, components, details of antigen for antibody detection of HIV 1 and 2, bio- safety methodologies validity criteria interpretation of results performance characteristics storage conditions limitation of assays manufacturing & expiry dates should be provided with each kit. 5. The kit should have approval of the statutory authority in its country of origin. 6. In case of imported kits it should be registered and licensed under the provisions of drugs & cosmetics act and rules and/ or medical devices rules 2017 in India. 7. In case of indigenous manufacturers should be licensed under the provisions of drugs & cosmetics act and rules and or medical devices Rules 2017 issued by the competent authority defined under drugs and· cosmetics act, 1940. 8. The kit should have minimum shelf- life of 5/61hor 12 months (whichever is more) at the port of discharge of consignees. 9. The time required of performing the test should not be more than 20 minutes. 10. The control dot/ band should be able to detect the presence of human immunoglobulin and should not be just a "procedural control" or meant for merely checking the flow of reagents or integrity of the antigen. Except for lateral flow assays 11. The assay should have sensitivity of 100% and specificity of 99 % or more with documentary evidence. 12. The test kit should be packed such that there is a provision to conduct single test at a time. 13. The pack size should not be more than 50 tests/kits. 14. The storage & transport temperature of the Kit should be 2-30°C.
Hepatitis B surface antigen (Rapid) testing kits 1. Should be solid phase/ particle coated with monoclonal antibodies to HBsAg 2. The assay should be able to detect surface antigen to Hepatitis B virus. 3. The assay should be able to detect all 11 sub types of HBsAg. 4. The assay should utilize the combination of Monoclonal & polyclonal antibodies to HBsAg for detection. 5. Adequate documents detailing the principle components, bio- safety methodologies, validity criteria, interpretation of results, performance characteristics storage conditions, limitation of assays manufacturing & expiry dates should be provides with each kit. 6. The kit should have approval of the statutory authority in its country of origin.7. In case of imported kits it should be registered and licensed under the provisions of Drugs & Cosmetics act and rules and/or medical devices rules 2017 in India. 8. In case of indigenous manufacturers should be licensed under the provisions of Drugs & cosmetics Act and rules and. or medical devices rules 2017 issued by the competent authority defined under Drugs and cosmetics act, 1940, 9. The kit should have minimum shelf- life of 5/6th or 12 months (whichever is more) at the port of discharge of consignees. 10. The total procedure time shall not be more than 30 minutes. 11. Assay should have Sensitivity 100% & specificity 100% or more with documentary evidence. 12. The storage & transport temperature of the Kit should be 2-30°C. 13. The pack size should not be more than 50 tests wherein each test is individually packed.
HCV (Ragid) testing kits 1. Should be solid phase/ particle coated with recombinant and / or synthetic peptide antigens for Core, NS3, NS4 and NSS. 2. The assay should able to detect total antibodies (lgG, lgM & lgA) specific to HCV in human serum, plasma or whole blood. 3. Adequate documents detailing the principle, components, bio- safety methodologies, validity criteria interpretation of results, performance characteristics storage conditions, limitation of assays manufacturing & expiry dates should be provided with each kit. 4. The kit to be procured should have approval of the statutory authority in its country of origin. 5. The kit should have approval of the statutory authority in its country of origin. 6. In case of imported kits it should be registered and licensed under the provisions of drugs & cosmetics act and rules and/ or niedical devices rules 2017 in India. 7. In case of indigenous manufacturers should be licensed under the provisions of drugs & cosmetics act and rules and or medical devices rules 2017 issued by the competent authority defined under drugs and cosmetics act, 1940. 8. The kit should have minimum shelf- life of 5/6" or 12 months (whichever is more) at the port of discharge of consignees. 9. The total procedure time shall not be more than 20 minutes. 10. Assay should have Sensitivity 100% & specificity 100% or more with documentary evidence 11. The storage & transport temperature of the Kit should be 2-30°C. 12. The pack size should not be more than 50 tests wherein each test is individually evidence.
SyphilisAntibody (Rapid) detection kits 1. The assay should be based on Rapid chromatographic immunoassay for qualitative detection of Antibodies (lgG, lgA & lgM) to TP in serum, plasma & whole Blood. 2. The assay should utilize recombinant Treponemal antigens i.e. Tp15, Tpl7, Tp47 against Syphilis. 3. The assay should be in card format. 4. Adequate documents detailing the principle components, bio- safety methodologies, validity criteria, interpretation of results, performance characteristics storage conditions, limitation of assays manufacturing & expiry dates should be provides with each kit. 5. The kit should have approval of the statutory authority in its country of origin. 6. In case of imported kits it should be registered and licensed under the provisions of Drugs & Cosmetics act and rules and/or medical devices rules 2017 in India. 7. In case of indigenous manufacturers should be licensed under the provisions of Drugs & cosmetics Act and rules and or medical devices rules 2017 issued by the competent authority defined under Drugs and cosmetics act, 1940. 8. The kit should have minimum shelf- life of 5/6th or 12 months (whichever is more) at the port of discharge of consignees. 9. Read result time should not be more than 20 minutes. 10. Assay should have Sensitivity 100% & specificity 99 %or more with documentary evidence. 11. The storage & transport temperature of the Kit should be 2-30°C. 12. The pack size should not be more than 50 tests wherein each test is individually
Malaria Antigen (Rapid) detection test 1. Test should be based on lmmunochromatographic assay. 2. The test should able to differentially detects Antigen of P. falciparum (HRP-2/ LDH) and Pan Plasmodia against P. falciparum, P. vivax, P. ovale, P. malariae (LDH) from human whole blood.in two different brand/lines. 3. The test band & control band should have different colours/same colours for differentiation of control & Test band with respect to use of whole blood as a sample. 4. The membrane strip should be pre-coated with the antibodies specific to Histidine-rich protein II (HRP II) of P. falciparum on Pf test line and specific to the lactate Dehydrogenase (pLDH) Plasmodium species (P. falciparum, P. vivax, P. malariae, P. ovale) on Pan test line separately 5. The test should be in card format not in strip. 6. Adequate documents detailing the principle components, bio- safety methodologies, validity criteria, interpretation of results, performance characteristics storage conditions, limitation of assays manufacturing & expiry . dates should be provides with each kit. 7. The kit should have approval of the statutory authority in its country of origin. 8. In case of imported kits it should be registered and licensed under the provisions of Drugs & Cosmetics act and rules and/or medical devices rules 2017 in India. 9. In case of indigenous manufacturers should be licensed under the provisions of Drugs & cosmetics Act and rules and or medical devices rules 2017 issued by the competent authority defined under Drugs and cosmetics act, 1940. 10. The kit should have minimum shelf- life of 5/6th or 12 months (whichever is more) at the port of discharge of consignees. 11. Read result time should not be more than 30 minutes. 12. The storage & transport temperature of the kit should be 2-30°C. 13. The pack size should not be more than 50 tests wherein each test is individually packed.
apid Test)- NE-69 1. Should be coated with monoclonal antibodies covering all subtypes and variants of HBsAg 2. The assay should be able to detect surface antigen to Hepatitis B virus. 3. Should be compatible with plasma and serum both. 4. Adequate documents detailing the principle, components, biosafety, methodologies, validity criteria, interpretation of results, performance characteristics, storage conditions, limitation of assays, manufacturing and expiry dates should be provided with each kit. 5. The kit should have approval of the statutory authority from the country of origin 6. In case of imported kits it should be registered and licensed by the DCG(I) 7. In case of indigenous manufactures should be licensed by the competent authourity/licensing authority defined under Drugs and Cosmetics Act (1940) and medical device rule 2017 8. The kit should have minimum shelf life of 60% or 12 months (whichever is more) at the port/place of discharge of consignees. 9. The total procedure time shall not be more than 30 minutes. 10. The assay components should include positive and negative controls sufficient for conducting 20% of the tests (10% negative and 10% positive controls) which may be provided along with the kits if not a part of the kit. 11. The assay should have sensitivity of 100% and specificity of more than or equal to 98% as per the office order of MoHFW vide F. No 29/Misc./4/2016-DC(65) dated 13/6/2017 12. The control dot/band should be able to detect the presence of human immunoglobulin and should not be just a “procedural control”or meant merely for checking the flow of reagents or integrity of antigens except except lateral flow technology General specifications 1. The manufacturer/ authorized agent should ensure maintenance of cold chain during storage and transport of kits at 2-8 C. The cumulative time temperature indicator technology should be used on each kit and be per-qualified by WHO. 1. The pack size should not be more than 50 tests wherein each test is individually packed . 2. 8 Kits should be supplied along with the procurement lot of which four kits will be used for validation, subject to which the kits of each batch and lot no. will be supplied to program and four kits will be retained for evaluation close to the expiry of the kit or in case of legal dispute with regards to performance of the kit as per specified parameters 3. The kit will bw evaluated on the above parameters by the centers approved by the program The committee approved the specification of HBsAg(rapid test) trol dot/band should be able to detect the presence of human immunoglobulin and should not be just a “procedural control” or meant merely for checking the flow of reagents or integrity of antigens General specifications 1. The manufacturer/authorized agent should ensure maintenance of could chain during storage and transport of kits at 2-8° C. The cumulative time temperature indicator technology should be used on each kit and be pre-qualified by WHO. 2. The pack size should not be more than 50 tests wherein each test is individually packed. 3. 8 kits should be supplied along with the procurement lot of which four kits will be used for validation, subject to which the kits of each batch and lot no. will be supplied to program and four kits will be retained for evaluation close to the expiry of the kit or in case of legal dispute with regards to performance of the kit as per specified parameters 4. The kit will be evaluated on above perameters by the centers approved by the program committee approved the specifications for Hepatitis B surface Antigen (Rapid Test)
Antibody (Rapid Test)- NE-70 1. Should utilize recombinant and /or synthetic peptide antigens for core, NS3, NS4 and NS5. 2. The assay should detect total anti HCV antibodies 3. Should be compatible with plasma and serum both. 4. Adequate documents detaling the principle, components, biosafety, methodologies, validity criteria, interpretation of results, performance characteristics, storage conditions, limitation of assays, manufacturing and expiry dates should be provided with each kit. 5. The kit should have approval of the statutory authority from the country of origin 6. In case of imported kits it should be registered and licensed by the DCG (I) 7. In case of indigenous manufactures should be licensed by the competent authority/Licensing authority defined under Drugs and Cosmetics Act (1940) and medical device rule 2017 8. The kit should have minimum shelf life of 60% or 12 months (whichever is more) at the port/place of discharge of consignees. 9. The total procedure time shall not be more than 30 minutes. 10. The assay component should include positive and negative controls sufficient for conducting 20% of the tests (10% negative and 10% positive controls) which may be provided along with the kits if not a part of the kit. 11. The assay should have sensitivity more than or equal to 99% and specificity of more than or equal to 98% as per the office order of MoHFW vide F. No 29/Misc./4/2016-DC (65) Dated 12/7/2017 12. The control dot/band should be able to detect the presence of human immunoglobulin and should not be just a “ procedural control” or meant merely for checking the flow of reagents or integrity of antigens except in lateral flow technology. General Specifications 1. The manufacturer/ authorized agent should ensure maintenance of cold chain during storage and transport of kits at 2-8 C. The cumulative time temperature indicator technology should be used on each kit and be per-qualified by WHO. 2. The pack size should not be more than 50 tests wherein each test is individually packed. 3. 8 kits should be supplied along with the procurement lot of which four kits will be used for validation, subject to which the kits of each batch and lot no. will be supplied to program and four kits will be retained for evaluation close to the expiry of the kit or in case of legal dispute with regards to performance of the kit as per specified parameters 4. The kit will be evaluated on the above parameters by the centers approved by the program The committee approved the specification of Anti HCV antibody (rapid test) 11. The assay should have sensitivity more than or equal to 99% and specificity of more than or equal to 98% as claimed by the manufacturer in the kit literature 12. The control dot/band should be able to detect the presence of human immunoglobulin and should not be just a “procedural contol” or meant merely for checking the flow of reagents or integrity of antigens General Specifications 1. The manufacturer/ authorized agent should ensure maintenance of cold chain during storage and transport of kits at 2-8° C. The cumulative time temperature indicator technology should be used on each kit and be pre-qualified by WHO. 2. The pack size should not be more than 50 tests wherein each test is individually packed. 3. 8 kits should be supplied along with the procurement lot of which four kits will be used for validation, subject to which the kits of each batch and lot no. will be supplied to program and four kits will be retained for evaluation close to the expiry of the kit or in case of legal dispute with regards to performance of the kit as per specified parameters 4. The kit will be evaluated on the above parameters by the centers approved by the program The committee approved the specifications for Anti-HCV Antibody Kits (Rapid test)
Braided E Caprolactone Coated Lactomer 1, 90cm GS- 25,37-40MM1/2 CIRCLE TAPER POINT
Braided E Caprolactone Coated Lactomer 2-0 90cm GS- 25,3OMM1/2 CIRCLE TAPER POINT
Braided E Caprolactone Coated Lactomer 1 90cm Gs- 25,37-40MM1/2 CIRCLE REVERSE CUTTING
Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per USP Specifition, Purest Form Of Triclosan,40mm Needle, Size 1, 1/2 Circle Taper Point, 90 Cm
Braided E-Caprolactone Coated Lactomer 3-0 75CM C-14 , UNDYED 24MM 3/8 Circle Reverse Cutting
Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per USP Specifition, Purest Form Of Triclosan,30mm Needle, Size 2-0, 1/2 Circle Taper Point, 90 Cm
Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per USP Specifition, Purest Form Of Triclosan,40mm Needle, Size 1, 1/2 Circle Reverse Cutting OS Needle, 90 Cm
Braided E-Caprolactone Coated Lactomer 0 90CM GS-24 , VIOLET 40MM 1/2 Circle Taper Point
Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure As Per USP Specifition, Purest Form Of Triclosan,20mm Needle, Size 3-0, 1/2 Circle Taper Point, 70 Cm
Braided E-Caprolactone Coated Lactomer 1-0 90CM GS-25 , UNDYED 37-40MM 1/2 Circle Reverse Cutting
Polyglactin 910 Violet Braided, 1, 35 CM 1/2 Circle Reverse Cutting (Heavy) 23 MM -25 MM Needle
Polyglactin 5-0 RB Oval ½ Circle 16 Mm 45 Cm
Polyglactin 5-0 CC 3/8 Circle 16 Mm 45 Cm
Polyglactin910 (90% Glycolide & 10 % Lactide) Coated With 370 Polyglactin & Calcium Stearate, Impregnated With 97-103% Pure MP, Purest Form Of Triclosan, 26mm Needle, Size 2-0, 3/8 Circle Cutting, 90 Cm
Absorbable surgical suture sterilized surgical needled suture monofilament Polydioxanone Coated with Purest form of Triclosan violet 1/2 circle Taper Point, 17 mm needle, length 70cm size 3-0 [NRR- 16]
Absorbable surgical suture sterilized surgical needled suture monofilament Polydioxanone Coated with Purest form of Triclosan ,violet 1/2 circle Taper Point RB-1, 17 mm needle, length 70cm size 4-0 [NRR-17]
Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone, Violet 1/2 Circle Taper Point RB-2, Double Needle, 13 Mm Needle, Length 70cm SIZE 5-0
Absorbable Surgical Suture Sterilized Surgical Needled Suture Monofilament Polydioxanone, Violet 3/8 Circle Taper Point, BB SGLE ARMED Needle 17 Mm Needle, Length 70cm SIZE 5-0
Absorbable Surgical Suture Sterilized Surgical DOUBLE ARMED Needled Suture Monofilament Polydiaxanone Violet 6-0 RB 17 MM NEEDLE LENGTH 90 CM
Absorbable Surgical Suture Sterilized Surgical DOUBLE ARMED Needled Suture Monofilament Polydiaxanone Violet 6-0 RB 11 MM NEEDLE LENGTH 90 CM
Absorbable Surgical Suture Sterilized Surgical DOUBLE ARMED Needled Suture Monofilament Polydiaxanone Violet 5-0 RB 11 MM NEEDLE LENGTH 90 CM
Absorbable Surgical Suture Sterilized Surgical SINGLE ARMED Needled Suture Monofilament Polydiaxanone Violet 5-0 RB 17 MM NEEDLE LENGTH 90 CM
Monofilament Polyglyconate 1 150cm Gs-25 Loop, Green 48mm 1/2 Circle Taper Point
Monofilament Polyglyconate 2-0, 75cm GREEN 26- 30MM 1/2 Circle Taper Point
Monofilament Polyglyconate 3-0, 75cm GREEN 20- 26MM 1/2 Circle Taper Point
Monofilament Polyglyconate 4-0, 75cm GREEN 17-20MM 1/2 Circle Taper Point
Monofilament Synthetic Absorbable Suture Polydioxanone - Violet EP 3- 0,70 Cm,1/2 Circle R.B.,20 Mm
Monofilament Synthetic Absorbable Suture Polydioxanone - Violet EP 4- 0,70 Cm,1/2 Circle R.B.,20 Mm
Monofilament Synthetic Absorbable Suture Polydioxanone - Violet EP 5- 0,70 Cm,1/2 Circle R.B.,13 Mm
Monofilament Glycomer 1 90cm Gs-21 , Volet 37mm 1/2 Crcle Taper Pont
Monofilament Glycomer 2-0 90cm Gs-21 , Volet 37mm 1/2 Crcle Taper Pont
Non Absorbable Surgical Suture, Sterilized Surical Needled BLACK BRAIDED SILK WITH NEEDLE 1/2 Circle Round Bodied 30 Mm Needle , Length 70 Cm Size 2-0
Braided Coated Non Absorbable Suture USP 1-0 75 Cm X 2
Braided Coated Non Absorbable Suture USP 2-0 75 Cm X 2
Braided Coated Non Absorbable Suture USP 3-0 75 Cm X 2
Silk Reel 4-0
Braided Polyester Caoted With Silicon 2, 26MM 1/2 Circle RC 75cm
Braided Polyester Caoted With Silicon 5, 55MM 1/2 Circle RC 75cm
Polypropylene Blue Monofilament, 2-0, 90 CM 1/2 Circle Round Body Double Needle 26 MM
POLYPROPYLENE BLUE MONOFILAMENT USP 3/0,2,90 Cm,1/2 Circle Taper Point (Double Armed),26 Mm
Polypropylene Blue Monofilament, 4-0, 75 Cm 1/2 Circle Round Body Double Needle 17 Mm
POLYPROPYLENE BLUE MONOFILAMENT USP 5/0,1,90 Cm,1/2 Circle Taper Point (Double Armed),18 Mm
Polypropylene Blue Monofilament, 6-0, 75 CM 3/8 Circle Round Body (380 Microns) Double Needle (Cutting) 13 MM
Non Absorbable Polypropylene Surgical Sutures Size:7- 0,3/8 Circle C1 Taper Point CV Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,8 Mm,60 Cm
Monofilament Polybuetester Coated With Polytribiolate 6- 0 75CM 2XCV-1X36 , BLUE 9MM 3/8 Circle Taper Point
Monofilament Polybuetester Coated With Polytribiolate 4- 0 90CM 2XCV-23X36 , BLUE 17MM 1/2 Circle Taper Point
Monofilament Polybuetester Coated With Polytribiolate 7- 0 60CM 2XMV-175-8 , BLUE 8MM 3/8 Circle Taper Point
Monofilament Polybuetester Coated With Polytribiolate 2- 0 90CM 2XV-20X36 , BLUE 26MM 1/2 Circle Taper Point
Monofilament Polybuetester Coated With Polytribiolate 3- 0 90CM 2XV-20X36 , BLUE 26MM 1/2 Circle Taper Point
Non-Absorbable Synthetic Unidrectional Dual Cut Angle Barb With Welded Loop Or Tab End Made Up With Polybeutester Size 1, 37mm, 30cm, 1/2 Circle, TP
Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polybeutester Blue Size 2-0, 1/2 Circle, 37mm, 30cm TP,
Absorbable Synthetic Unidirectional Dual Cut Angle Barbed With Welded Loop Or Tab End Made Up With Polyglyconate 2-0 26-30 Mm 30 Cm 1/2 Circle Taper Point
Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polyglyconate Green Size 1- 0, 1/2 Circle, 37mm, 30cm TP
Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polyglyconate Green Size 2- 0, 1/2 Circle, 26mm, 30cm TP
Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop Or Tab On End Madeup With Polyglyconate Green Size 3- 0, 1/2 Circle, 26mm, 30cm TP
Synthetic Absorbable Wound Closure Device With Dual Cut Barb With Velded Loop On End Madeup With Glycomer Blue Size 2-0, 1/2 Circle, 24mm, 30-45cm RC
Polyester Ethylene Terephthalate Nonabsorbable Surgical Suture Polyester Suture Is A Nonabsorbable, Braided, Sterile, Surgical Suture Composed Of Poly (Ethylene Terephthalate.) It Is Prepared From Fibers Of High Molecular Weight, Long-Chain, Linear Polyesters 1 /2 Circle Tapercut 2 X V-5 Double Needle 26 Mm 90 Cm Green Color Size 2-0
Laproscopic Knotless PGA -PCL Bidirectional Taper Point Surgical Suture Self Fixation Device With Autolock Mechanism Made Up Of PGA -PCL Bidirectional Taper Point 17 Mm & 32cm
Absorbable Antibacterial Polydiaxonone Monofilament Taper Point Surgical suture Absorbable Antibacterial suture made up of Polydiaxonone coated with triclosan Voilet Monofilament 1/2 Circle Taper Point CT-1 40 mm needle 90 cm Suture size 1 [NRR-75]
Braided Coated Non Absorbable Suture Natural Silk - Black Dyed USP 1- 0,90 Cm,1/2 Circle R.B.,30 Mm
Non-Absorbable Surgical Suture Black Braided Silk 1-0 RC 3/8 Circle 45 Mm 76 Cm
Non-Absorbable Surgical Suture Black Braided Silk 5-0 RC 3/8 Circle 12 Mm 76 Cm
Braided Coated Non Absorbable Suture Natural Silk - Black Dyed USP 5- 0,76 Cm,3/8 Circle R.B,12 Mm
Non-Absorbable Surgical Suture Black Braided Silk 6-0 RC MP 3/8 Circle 8 Mm
Braided Coated Polyglactin Absorbable Suture Polyglactin 910 -Undyed 2-0, 1/2 Circle Taperpoint, 36 Mm,100 Cm
Absorbable Surgical Suture (Synthetic )Coated Polyglactin/PGA 910 Voilet 6-0 RB Micro Point ¼ Circle 8 Mm 45 Cm '2670'
Absorbable Surgical Suture (Synthetic )Coated Polyglactin/PGA 910 Voilet 4-0 CC 3/8 Circle 16 Mm 45 Cm '2442'
Absorbable Surgical Suture (Synthetic )Coated Polyglactin/PGA 910 Voilet 3-0 CC 3/8 Circle 16 Mm 45 Cm '2442'
Absorbable Surgical Suture (Synthetic )Coated Polyglactin/PGA 910 Voilet 5-0 CC 3/8 Circle 16 Mm 45 Cm '2442'
Absorbable Surgical Suture (Synthetic )Coated Polyglactin/PGA 910 Voilet 5-0 RB Oval 1/2 Circle 16 Mm 45 Cm
Non Absorbale Surgical Suture Sterlised Surgical Needle Suture Polyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 26mm Length 70cm3-0
Non Absorbable Surgical Suture Sterilized Surgical Needle Suture Polyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 16mm Length 70cm4-0
Non Absorbale Surgical Suture Sterlised Surgical Needle Suture Polyamide Mono Filament Black (Nylon) 3/8 Conventional Cutting Needle 16mm Length 70cm 5-0
Non Absorbable Polypropylene Surgical Sutures Size:6- 0,3/8 Circle 175- 6 Taper Point /RC BV Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,9.3 Mm,60 Cm 13 Mm
Non Absorbable Polypropylene Surgical Sutures Size:7- 0,Compound Curve ( 1/2 & 3/8 Circle) Circle 175-6 Taper Point Blackmatte Needle Made Of Tungsten - Rhenium Alloy And Finished With Multilayer Silicon Coating Double Armed,9.3 Mm,60 Cm
Monofilament Synthetic Absorbable Suture Poliglecaprone 25 - Undyed EP 3-0,70 Cm,1/2 Circle Oval R.B. J.B. Needle,26 Mm
Braided Coated Polyglactin Absorbable Suture Polyglactin 910 -Undyed 3-0, 3/8 Circle Reverse Cutting,PS Prime 24 Mm,75 Cm
ITL Labs Pvt. Ltd. (BID ID -3141317)
SHREE KRISHNA ANALYTICAL SERVICES PVT LTD (BID ID -3139803)
devansh testing and research laboratory pvt ltd (BID ID -3145806)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .