| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.5 LAdmitted-Finance | ₹55.5 L | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | BIDHAN DEB L1 |
|---|---|---|---|---|
| 1.00UG TANKS | ||||
| 1.01 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and
disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil. | 298.36 | cum | 257 ₹76,678.52 |
| 1.02 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level
1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 7.64 | cum | 7,799 ₹59,584.36 |
| 1.03 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more. | 5,851.92 | kg | 105 ₹6.1 L |
| 1.04 | Centering and shuttering including strutting, propping etc. and removal of form for
5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | 452 | sqm | 833 ₹3.8 L |
| 1.05 | 5.9.20 Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick | 87.6 | sqm | 1,017 ₹89,089.20 |
| 1.06 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 73.56 | cum | 8,954 ₹6.6 L |
| 1.07 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) | 13.5 | cum | 7,296 ₹98,496 |
| 1.08 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. | 8 | sqm | 5,745 ₹45,960 |
| 1.09 | Supplying fitting and fixing iron removal filter filling with treated sand, pebbles, manganish dioxide and other required materials of various filtration rate per hour of AQUAFIZER make with all necessary fittings such as valve,bib cock,pipe connection etc.
6,000 liters / hour capacity 3 nos | 5 | nos | 1,66,000 ₹8.3 L |
Tender Value
₹56.2 L
EMD Value
₹1.1 L
Closing Date
5 Mar 2026, 11:00 amClosed
EXECUTIVE ENGINEER CIVIL I/C
ENGINEERING SECTION, ASSAM UNIVERSITY SILCHAR
C/O 4 nos UG Tanks 25,000 ltr. Capacity (plus 3750 ltr. Free board)including RCC motor shed , Iron removal filter and 7 nos. deep tube wells at variouslocations - i) Central Library, Maths, Law, Earth Science, Library Science, ii) NearBengali and Lin
2026_AUS_900422_1
AU/ENGG/CONST/07/2026
Open Tender
Civil Works
120 days
ASSAM UNIVERSITY SILCHAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
Assam University Silchar
₹1.1 L
6 Mar 2026
26 Feb 2026
6 Mar 2026
26 Feb 2026
5 Mar 2026
26 Feb 2026
UG TANKS
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.20 Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Supplying fitting and fixing iron removal filter filling with treated sand, pebbles, manganish dioxide and other required materials of various filtration rate per hour of AQUAFIZER make with all necessary fittings such as valve,bib cock,pipe connection etc. 6,000 liters / hour capacity 3 nos
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 18.7.4 32 mm nominal outer dia. Pipes.
40 mm nominal outer dia. Pipes.
50 mm nominal outer dia. Pipes.
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 32 mm nominal bore (Horizontal )
40 mm nominal bore (Vertical )
50 mm nominal bore Horizontal
Tube well
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 23.1.1 All types of soil 23.1.1.1 300 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & up to 150 metre depth below ground level 23.2.2 Rocky strata including Boulder 23.2.2.2 300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge 23.3.2 150 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 23.4.2 150 mm nominal size dia
Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. {(0.30)2x3.14 – (0.15)2x3.14}x150.00 =31.89x7
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete 23.14.2 150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I) 23.15.2 150 mm dia
Site preparation , motor shed painting etc.
Any other items if requires during execution
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_946426.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid