Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹22.8 LAdmitted-Finance 117 2 KAKA DEV KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | -43.00% | ₹22.8 L | L1 | Admitted-Finance |
| 2 | L2₹31.1 LAdmitted-Finance | -21.98% | ₹31.1 L | L2 | Admitted-Finance |
Tender Value
₹39.9 L
EMD Value
₹80,000
Closing Date
10 Feb 2026, 5:00 pmClosed
GM JAL
Sector-5, Noida
M/o Sewerage (Raising of Sewer Manholes and Making water Connection Chambers in Udyog Vihar LIG Apartment Duplex Sector-82) Noida.
2026_NOIDA_1112354_1
16/SM-JAL-III/2025-26
Open Tender
Civil Works - Others
90 days
NOIDA
Please refer to tender document
3 documents required · 3 mandatory
₹2,124
NOIDA
₹80,000
11 Mar 2026
4 Feb 2026
11 Feb 2026
4 Feb 2026
10 Feb 2026
4 Feb 2026
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge.
C/fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality EHD - 35 Circular shape (New)
560 mm internal dia (Cover Frame Free of Cost From Div. Store)
C/Fixing FRC manhole cover with frame i/c loading, unloading cartage at site labour charges for fixing etc. complete in all respect as per direction of E/I.(Old cover frame available at site)
a) Circular shape 560 mm dia precast R.C.C. manhole cover with frame - H.D. - 20 (Old) DSR-2018
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 100 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand)
Centering & Shuttering i/c strutting, proping etc. and removal of form for
a) Foundations, footings, bases of columns etc. for mass concrete
Cement Concrete with 2 cm gauge approved stone ballast coarse sand & cement in the proportion of 8:4:1 including supply of all materials labour tool & plants etc required for proper completion of the work.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m,disposed earth to be levelled and neatly dressed. .The contractor has to detect different utilities like sewer line,water supply line, electric cable,telephone cable,gas pipe line etc.using utility detecting machine before start of excavation and shall start excavation only after getting permission of Engineer-in-Charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing & Laying Non Pressure NP-2 class RCC Spigot Socketed pipe confirming to 458:2003 with latest ammendment laying in true alignment & Position on Craddle i/c rubber rings (Confirming to IS :5382 with latestammendmen) testing of laid pipe as per direction of Engineer in Charge complete in all respect (A.O.R.)
a) 250 mm dia NP-2
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :
Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test
as per specifications and having manufactrue's permanent identification mark to be visible even after fixing, including fixing in manholes with 30 x 20 x 15 cm cement concrete block 1:3:6 (1 cement : 3 c.sand : 6 graded stone agg.20 mm n.s.) complete as per design.
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
For pipes 250 to 300 mm diameter
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead upto 50 m and lift upto 1.5 m.
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge
20 mm nominal outer dia Pipes
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20 mm nominal bore
Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :
15 mm nominal bore
Please Enable Macros to View BoQ information
CAPABILITY STATEMENT
* It is compulsory for the bidder to fill this statement and the bidder must upload only those document that support this statement
Tender Reference No :
Tender : M/o Sewerage (Raising of Sewer Manholes & Making water Connection Chambers in Udyog Vihar LIG Appartment Duplex Sector-82) Noida.
Not Provided
Name of Tenderer
TOTAL NIT COST OF PROJECT (In Rs.) (In lacs)
Minimum Value
SOLVENCY (Issued within a period of maximum six months).
EXPERIENCE (WITH GOVERNMENT/SEMI- GOVERNEMTN/ PSUs ONLY) completed works during the last 7 years ending last day of the month previous to the one in which applications are invited
NOT QUALIFIED
NOT QUALIFIED
Two similar completed works each costing not less than the amount equal to 60% of estimated cost put to tender
NOT QUALIFIED
One similar completed works costing not less than the amount equal to 80% of estimated cost put to tender
RESULT OF EXPERIENCE
TURNOVER (During the immediate LAST 3 consecutive financial years)
Average annual financial turnover on construction works should be atleast 30% of the estimate cost during the immediate last 3 consecutive financial years.
Required Technical Staff
Required Machinary
Character certificate of Individual/Partners/directors issued from District Magistrate.
Affidavit of Not blacklisted.
Address Proof/ Id.Proof of Individual/partners/directors.
GST Registration certifcate.
Latest Income Tax Certificate
Filled in form Capability Statement..
Self declaration affidavit on Rs. 100/- Notarised Stamp paper
No Blood Relation decleration affidavit on Rs.-100 Notrarised Stamp paper
Certified Copies of relevant pages of following documents:
RESULT
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.