Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-Finance BELPUKUR NADIA | NADIA | WEST BENGAL | ₹28.7 L | L1 | Accepted-Finance Lowest Bidder |
| 2 | L2₹28.8 L+₹4,887.26 (0.17%)Rejected-Finance RAMESWAR NATH LANE CHOWDHURYPARA PO KRISHNAGAR DIST NADIA PIN 741101 | KRISHNAGAR | NADIA | WEST BENGAL | 741101 | ₹28.8 L+₹4,887.26 (0.17%) | L2 | Rejected-Finance Higher Bidder |
| 3 | L3₹28.8 L+₹8,337.09 (0.29%)Rejected-Finance PALLISREE KRISHNAGAR NADIA PIN 741101 | KRISHNAGAR | NADIA | WEST BENGAL | 741101 | ₹28.8 L+₹8,337.09 (0.29%) | L3 | Rejected-Finance Higher Bidder |
Tender Value
₹28.7 L
EMD Value
₹57,497
Closing Date
7 Aug 2026, 12:00 pmClosed
EXECUTIVEENGINEER_NADIAARSENIC DIVISIONI_PHE_DTE
KALYANI_NADIA
Restoration of damage pipeline due to widening strengthening and construction of Surface Water drain of WBHDCL and PWD roads at different location of Chakdah block under Nadia Arsenic Division I PHE Dte
2026_PHED_1033222_2
WBPHE_05_NAD_I_26_27
Open Tender
CIVIL WORKS
Item Rate
30 days
Chakdah
Please refer Tender documents.
4 documents required · 4 mandatory
₹57,497
14 Aug 2026
20 Jul 2026
10 Aug 2026
20 Jul 2026
7 Aug 2026
21 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supplying, laying, fiting, fixing and jointing of UPVC pipes conforming to IS:4985-2000 with latest revision and amendments, if any, with necessary UPVC/CI specials, CIDF sluice valves, as per relevant I.S. specification including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder ,road sub-grade and its flanks but excluding moorum and laterite or sand stonehard arock including cutting of brick payment without damaging the existing telephone/electrical cable line etc.(in case of damage of any type of cable line during excavation, necessary damaged charges as applicable by the respaective authority will be borne by the agency in his own cost. Loading, unloading, carrying of pipes, specials, valves from the local store to work site and lowering laying of pipes specials valves carefully in trenches maintaining proper levels and alignment ,jointing the pipe and specials including supplying of good quality/approved brand solvent cement (as per IS:14182-1994 including cost of all fabricated PVC fitting i.e. tees,bend, reducers, adopter etc.as per IS:101-1988 and making flange joints including supplying required quantity of nuts, bolts and rubber insertion (CIDF sluice valves will be supplied by the department free of cost) as required at site by adopting suitable method so as to facilate the maintenance of pipe line locally as per conventional method including back filling the trenches with good earth obtained from excavation of trenches including consolidation with watering in layer not exceeding 150mm thk. with maintaining an average depth of cushion of 1.10mtr. from the top of pipe line including making interconnection with distribution pipes etc. all complete as per drawing direction and satisfaction of the E.I.C. N.B. i) Manufacturer’s test certificate for UPVC pipe & specials to be produced before laying of pipe line. ii) 3rd party inspection of UPVC pipe & specials to be done by CEPET or (India) SGS/NTH Kolkata or as per direction of EIC as per approved vender list. iii)No part payment at any stage on account of supply of materials shall be entertained. iv)Payment will be made on actual consumption of materials. v)UPVC pipes for the works to be supplied as per approved vendor list and as per direction & satisfaction of EIC. No pipes will be allowed beyond recommendated vendor list. vi)Submission of drawing of pipe line with statement of materials consumed between node to node points against each R.A. & final bill.if so. vii) Any deviation from required clear cover of 1.10mtr.due to site adverse condition, prior permission is to be obtained from EIC and payment for such work will be made on prorate basis over the rate of entire item. viii)All pipe connection shall be completed in all respect and as per directionof EIC. Decision of EIC in this respect is final & binding. In case of any deviation/or any left out pipe connections an amount of Rs.10,000.00 for each pipe connection will be realized/recovered from the bill.
(ii) Laying of pipe line including cost of pipe & fittings/specials but excluding cost of valves.
a) 125mm OD UPVC line | - | mtr | 643 | - |
| 1.02 | b) 160mm OD upvc line | - | mtr | 974 | - |
| 1.03 | Supply & delivery of internal diameter M.S. Pipe of wall thickness 9.5 mm of TATA/SAIL make (spirally welded) as per IS 3589-2001 or as ammended to be delevered at site inclusive of all duties, taxes charges and cost of transporation, loading & unloading & stacking all complete at lifting and destination points all complete as per the direction of E.I.C.( 8 mm thick )
a) 200 mm dia (Rs 3128.32 for suuply and Rs 221.26 for lowering) | - | mtr | 4,149.38 | - |
| 1.04 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) B) Do- by fine sand. | - | %cum | 95,183 | - |
| 1.05 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.
(a) upto 150 mm. Thick | - | cum | 939 | - |
| 1.06 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per direction . | - | cum | 5,170.17 | - |
| 1.07 | Road restoration with Jhama metal / Jhama Chellyor Stone metal. | - | cum | 2,141.41 | - |
| 1.08 | Supply and delivery of CIDF sluice valve (Special type) PW-1.00 of different dia make with CI double flanged non rusting spindle sluice valves conforming to IS 14846 -2000 with latest emended having body dome/bonnet and cover of C.I.Gr-F.G 210mtr. spindle of IS-6603 G.R- 12/Gr-13 non-magnetic, nuts seat rings are of Gunonetal as per IS:318 LTB-2 flanges and drilled to IS:1538 Part IV & VI valves are suitable for max. working pressure of 10kg/cm2(seat test) and body tested to 15kg/cm2 .N.B: The above item should be procured from the reputed manufactures as per deptt. approved vender list
a) 200 mm dia | - | each | 16,632 | - |
| 1.09 | Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified] i) 200 mm dia | - | each | 16,045 | - |
| 1.1 | Add 18% GST (SGST-9% CGST-9%) (Payment to be made as per prevailing rules in vogue & as per actual executed ) | - | L.S. | 4,34,196.04 | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
Tendernotice_2.pdf
PDF • 0.74 MB
BOQ_2537503.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .