AEE
PWD ESD KALPETTA
GENERAL-NMSM Government College, Kalpetta-Urgent Maintenance work of Sarangi Auditorium - Electrification-General Electrical Work
2026_PWD_857711_1
PWD/BLDG/EST/18480/2025_6_1_1
Open Tender
Electrical Works
Item Wise
180 days
KALPETTA
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,030
₹11,652
15 Jul 2026
25 Jun 2026
9 Jul 2026
25 Jun 2026
2 Jul 2026
25 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrification | |||||
| 1.001 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | - | point | 1,576.54 | - |
| 1.002 | 1.54.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C | - | point | 1,175.94 | - |
| 1.003 | 90.3.20.3:Supply & installation of light fittings on TW round block
Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture | - | each | 1,262.82 | - |
| 1.004 | OD172875/2025-2026:Supply conveyance, installation, testingof Back lit Led Downlight Luminaire having
power consumption not more than 18W and light output
not less than 2000 Lumens with System efficacy> 110
Lumen/Watt. Housing Shall be made of pressure die
cast aluminum body with 40mm height suitable for
installation in low heights and polycarbonate diffuser to
reduce glare. The Luminaire should be having Minimum
50000 Burning hours(L70B50) with CRI ≥80,
SDCM<5and Co-related color temperature (CCT) of
6500K.The luminaire must have 2.5KV surge protection
integrated in driver, PF≥0.95, Total harmonic distortion
THD≤10%,EMI/EMC Compliant and Operating voltage
range 160-270V .Luminaire and driver shall be
separately BIS approved of same make equivalent to
Philips DN296B LED20S 6500 / kesslec /Osram.
LM80,LM79 ,Type Test certificate and Bis certificate
need to be submitted. | - | each | 2,927.46 | - |
| 1.005 | OD171647/2025-2026:SITC of Philips make surface mounting type 20 w LED round/ Square fitting , Model Number: SM200C LED16S 6500/4000 PSU OD WH /Equivalent make ) and giving connection etc. as required. | - | each | 3,678.28 | - |
| 1.006 | OD368930/2025-2026:Supply ,installation,testing and commissioning of 700lm pressure die cast housing Bulk head with IP65 protection & IK 08 having efficacy not less than 105lm/W and giving connection with 3 core flex wire as required. | - | each | 1,121.4 | - |
| 1.007 | OD171651/2025-2026:Supply and providing the following types and power rated lamps in the existing fittings as required. B22 LED bulb 9W | - | each | 126.55 | - |
| 1.008 | 90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | - | each | 5,045.42 | - |
| 1.009 | 90.15.4.6:Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | - | each | 8,599.61 | - |
stage.html
html • 0.02 MB
finance_1449864.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
conditions.pdf
Tender Documents • 0.08 MB
ML.pdf
Tender Documents • 0.55 MB
BOQ_1449864.xls
BOQ • 0.36 MB
viewsbd.pdf
Tender Documents • 2.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .