Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹25.5 L+₹2.6 L (11.2%)Rejected-Finance MOH SWAMI PADAM JAHANGIRPUR GREATER NOIDA GAUTAM BUDH NAGAR UP 203141 | GREATER NOIDA | GAUTAM BUDH NAGAR | UTTAR PRADESH | 203141 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹27.3 L+₹4.3 L (18.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
23 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-71/2021-22 MAINTENANCE OF MISCELLANEOUS SMALL COOLING APPLIANCES AT AF STATION AMBALA UNDER GE (AF) AMBALA
2022_MES_509896_1
GE AF/AMB-71/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
Yes
GE AF AMBALA
₹50,000
Yes
5 Apr 2022
23 Feb 2022
25 Mar 2022
23 Feb 2022
23 Mar 2022
10 Mar 2022
2 Mar 2022 - 7 Mar 2022
60 days
Amount
M&L for servicing of split type AC 1.5/2TR capacity, cleaning of cooling coil, air filters/plasma filters, etc. (indoor unit), condenser, compressors, fan motor, etc. (outdoor unit) with vacuum cleaner and cleaning solutions, etc. and checking serviceability of the AC unit complete all as specified and as directed
M&L for servicing of pillar type AC 4TR capacity, cleaning of cooling coil, air filters / plasma filters, etc. (indoor unit), condenser, compressors, fan motor, etc. (outdoor unit) with vacuum cleaner and cleaning solution, checking serviceability of AC unit complete all as specified and as directed
M&L for servicing of casette type AC 2TR capacity, cleaning of cooling coil, air filters / plasma filters, etc. (indoor unit), condenser, compressors, fan motor, etc. (outdoor unit) with vacuum cleaner and cleaning solution, checking serviceability of AC unit complete all as specified and as directed
M&L for servicing of window type AC 1.5/2TR capacity for required servicing, cleaning of cooling coil, air filters / plasma filters, etc. (indoor unit), condenser, compressors, fan motor, etc. (outdoor unit) with vacuum cleaner and cleaning solution, checking serviceability of AC unit complete all as specified and as directed
M&L for noting down and attending day to day complaint of split type AC/ window type AC/pillar type AC/casette type AC of any capacity, of any make & type and finding out defect, taking out unserviceable electrical / electronic parts (except evaporator coil, cooling coil, blower motor, condensor motor & compressor sealed units) viz. capacitor, single phasing contactor, thermostat switch, lit lawn sheet, fan blade, wiring kit, remote control, PCB, etc. and replacing with serviceable spare parts ensuring the AC unit in satisfactory working conditions complete all as specified and as directed Note: (i) Spares used and refrigerant,capillary filter, refrigerant choking and topping up will be measured and paid under respective items herein. (ii) Cost of repairs involving labour only such as water leaking, sounding, electric supply fault, supply bypass due stablizer unserviceability shall be included in the quoted rate. and repair invoving shall be measured and paid seprately
Supply only running capacitor 45MFD / 50MFD
Supply only starting capacitor 100-120MFD
Supply only capacitor 6MFD
Supply only capacitor 4MFD
Supply only capacitor 2.5MFD
Supply only single phasing contactor
Supply only thermostat switch any type
Supply only starting relay 1022/1622
Supply only starting relay 2000
Supply only lit lawn sheet 6mm thick and 1000mm wide
Supply only condenser fan blades for window type AC units of capacity 1.5T/2T
Supply only condenser fan blades for spilt type AC units of capacity 1.5T/2T
Supply only thermocol sheet 40x20inch and 20mm thick
Supply only wiring kit for window / split type AC units 1.5/2TR
Supply only universal remote control for window / split ACs of capacity 1.5/2TR
Repair of main printed circuit board (PCB) with electric accessories and sensors of split / window Acs of capacity 1.5/2TR
Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for split / window ACs of capacity 1.5/2TR
Supply only front louvers (front panel) for window type AC units 1.5/2T
Supply only suction and discharge valve set for type split AC 1.5/2T
Supply only refrigerant gas R-134A for window type / split type AC
Supply only refrigerant gas R-22 for window type / split type AC
Supply only compressor oil for window type / split type AC
M&L for shifting of split AC of capacity 2/1.5TR involving disconnecting from mains and taking out from existing location, transporting, installing at new location including making electric connections, making suction and discharge copper pipe connections, insulating copper pipes, charging of refrigerant and commissioning complete all as specified and as directed
M&L for shifting of window AC of cap 2/1.5TR involving disconnecting from mains and taking out from existing location, transporting, installing at new location including making electric connections & air tighting the recess with insulation around AC casket and commissioning complete all as specified and as directed
M&L for disconnecting from mains and taking out existing unserviceable split type air conditioner units of capacity 2/1.5Ton, of any make, type from any location, carting to workshop, etc. for required repairs, cleaning and removing dust/dirt from the cooling coil, condenser coil, etc. with necessary modification (capilary tube, etc.), charging of gas R-22/R-134A and refixing, commisioning and testing complete all as specified and as directed Notes: (i) Transportation, loading, unloading, etc. from site to workshop and back to original location after repair shall be deemed to be included in unit rate quoted (ii) Overhauling shall be got done from manufacturer's authorised service centres as approved (ii) Repaired units shall bear a guarantee for a period of 24 calender months from date of installation of repaired unit. Such documentation shall be kept on records duly signed by both the parties
Supply, installing, testing and commissioning of compressors of AC units in any location / position including disconnecting electrical mains, remove the refrigerant and capture it in a storage cylinder, cutting line sets, removing the condenser coil and everything around the compressor, taking out the condenser unit, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally put the rest back together and balance charging of refrigerant gas F-22/R-134A (if required) including disposing of old unserviceable condensor unit complete all as specified and as directed for the following types and capacities: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
Window type air conditioner of capacity 2Ton
Window type air conditioner of capacity 1.5Ton
Split type air conditioner of capacity 2Ton
Split type air conditioner of capacity 1.5Ton
M&L for taking down unserviceable burnt out door condensor fan motor of split AC of capacity 1.5 / 2.0TR, repairing / rewinding the same with super enamelled copper conductor of existing gauge, replacing the set of bearing including lathe works for making bearing seat, re-installing the same in position, commissioning and testing complete all as specified and as directed
M&L for taking down unserviceable burnt out condensor cum blower double shaft fan motor of window AC of capacity 1.5 / 2.0TR, repairing / rewinding the same with super enamelled copper conductor of existing gauge, replacing the set of bearing including lathe works for making bearing seat, re-installing the same in position, commissioning and testing complete all as specified and as directed
M&L for taking down unserviceable burnt Indoor blower fan motor of split AC of capacity 1.5 / 2.0TR, repairing / rewinding the same with super enamelled copper conductor of existing gauge, replacing the set of bearing including lathe works for making bearing seat, re-installing the same in position, commissioning and testing complete all as specified and as directed
Supply, installing and testing of condenser coils of split AC capacity 1.5 /2.0TR in any location / position including disconnecting electrical mains, removing the clutter, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and reassembling together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed Note: Charging of refrigerant will be measured and paid seprately under respective item herein
Supply, installing and testing of condenser coils of window AC capacity 1.5 /2.0TR in any location / position including disconnecting electrical mains, removing the clutter, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed Note: Charging of refrigerant will be measured and paid seprately under respective item herein
Supply, installing and testing of evaporator coils of split AC capacity 1.5 /2.0TR in any location / position after disconnecting electrical mains, removing the clutter, wires, sensor, cleaning, removing dust / dirt, etc., around and replacing evaporator coil and finally put the rest back together and commissioning including disposing of old unserviceable evaporator coil complete all as specified and as directed Note: Charging of refrigerant will be measured and paid seprately under respective item herein
Supply, installing and testing of evaporator coils of window AC capacity 1.5/2.0TR in any location / position after disconnecting electrical mains, removing the clutter, wires, sensor,cleaning, removing dust / dirt, etc. around and replacing evaporator coil and finally put the rest back together and commissioning including disposing of old unserviceable evaporator coil complete all as specified and as directed Note: Charging of refrigerant will be measured and paid seprately under respective item herein
S&F copper pipe with all necessary brazing, welding, providing isulation, butt bolts and screws of required sizes, clamps, etc. including taking down old unserviceable copper pipes of any sizes / dia and disposing off complete all as specified and as directed for the following sizes:
M&L for detecting leakages of gas in window / split type AC units of capacity 1.5/2TR in any location / position, rectifying the same by brazing and pressure testing complete all as specified and as directed Note: Charging of refrigerant will be measured and paid seprately under respective item herein
M&L for replacement of capillary filter for rectification of refrigerant choking in window / split type ACs of capacity 1.5/2TR in any location / position, rectifying the same by brazing and pressure testing complete all as specified and as directed Note: Charging of refrigerant will be measured and paid seprately under respective item herein
M&L for charging refrigerant gas F-22/R-134A in split type AC units of capacity 1.5 / 2.0TR including vacuuming the unit with vacuum pump to requisite level, as required, testing and commissioning in satisfactory working conditions complete all as specified and as directed
M&L for charging refrigerant gas F-22/R-134A in window type AC units of capacity 1.5/2.0 TR including required staging / taking down of compressor units, etc. as required and testing and commissioning in satisfactory working conditions complete all as specified and as directed
Supply, installing and testing outdoor unit of 2T split type air conditioner in any location / position including disconnecting electrical mains, removing the wires etc. and commissioning including disposing of old unserviceable outdoor unit and depositing in MES AC section yard complete all as specified and as directed Notes: (i) Charging of refrigerant will be measured and paid seprately under respective item (ii) Cost of all loading, unloading, carting, etc. for transporting to MES yard shall be included in the quoted rate
Supply, installing and testing Indoor unit of 2T split type air conditioner in any location / position including disconnecting electrical mains, removing the wires etc. and commissioning including disposing of old unserviceable outdoor unit depositing in MES AC section yard complete all as specified and as directed Notes: (i) Charging of refrigerant will be measured and paid seprately under respective item (ii) Cost of all loading, unloading, carting, etc. for transporting to MES yard shall be included in the quoted rate
M&L for submain wiring using 2 runs of 4sqmm single core PVC insulated, un-sheathed, multistranded copper conductor cable, 1100V grade, ISI marked drawn through and including non-metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories viz. tee, bends, elbow, etc. fixed on wall//ceiling/truss and PVC moulded box of suitable size having minimum depth of 50mm, ISI marked for housing of electrical accessories, and one run of PVC insulated, unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100volts, ISI marked, green colour as earth continuty conductor connected to common earth dolly for metal clad switch sockets 20A including taking down of old submain wiring with accessories, fixtures, etc. and disposing off complete all as specified and as directed Notes: (i) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth- Green (ii) 2 runs of 4sqmm main cable, 1 run of earth conductors and 1 run of PVC casing caping as per item shall be measured as one length
Notes for item No. 55 contd..: (iii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire (iv) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit as per requirement at site
S&F in repairs metal clad switch socket outlet with single pole and neutral enclosure with two pin and earth plug socket with 01No. single pole MCB 20A 10kA complete all as specified and as directed
S&F MCB SP, 240V, 25 to 40A, 10kA including taking old unservicable MCBs of any type and disposing off complete all as specified and as directed
M&L for collecting unserviceable voltage stabilizer of capacity 3kVA from the MES store yard (AGE E/M-I), transporting to workshop, disassembling the unit for locating the fault including checking serviceability of electrical/electronic parts viz. circuits relays, etc. and replacing the defective spare parts, re-assembling after making connections, testing by applying low and high voltage input to get the 230V correct output and transporting back the same to MES store yard complete all as specified and as directed
M&L for collecting unserviceable voltage stabilizer of capacity 4 to 5kVA from the MES store yard (AGE E/M-I), transporting to workshop, disassembling the unit for locating the fault including checking the serviceability of electrical/electronic parts viz. circuits relays, etc. and replacing the defective spare parts, re-assembling after making connections, testing by applying low and high voltage input to get the 230V correct output and transporting back the same to MES store yard complete all as specified and as directed
Notes for item Nos. 59 & 60: (i) Cost of all loading, unloading, carting, etc. for transporting to MES yard shall be included in the quoted rate (ii) Replacement of defective spares / rewinding of transformers of voltage stabilizers will be measured and paid separately under respective items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted in this item
Supply only printer circuit control card suitable for 4kVA to 5kVA voltage stablizer
Supply only input/output switch
Supply only push on switch
Supply only indicator complete with bulbs
Supply only trigger transformer for 3kVA to 5kVA voltage stablizer
Supply only relay for 3 to 5kVA voltage stablizer
Supply only time delay and high/low voltage cut off circuit with relay suitable for 3kVA to 5kVA
M&L for taking out burnt windings of transformers of voltage stablizers and prepairing core after cleaning by suitable cleaning agent and rewinding the transofrmer with super enamel copper wire of existing gauge and number of windings including varnishing, heating and refitting complete all as specified and as directed for the following capacities of voltage stabilizers:
3 to 4kVA
M&L for opening electric / control panels, general cleaning and repairing / replacing defective parts / components and checking overall serviceability and making panels functional complete all as specified and as directed Notes: (i) New spares / parts required will be measured and paid separately under respective items herein (ii) Labour charges for taking out defective spares / parts and fixing of new spares / parts shall deemed to be included in the quoted rate against this item
M&L for disconnecting from mains and taking down for repair / servicing water coolers including cleaning the cooling coil, air filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc. and making the water cooler to satisfactory working conditions all as specified and as directed for the following capacities: Note: Spares / parts / componenets reaplaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement shall be deemed to be included in the unit rate quoted
Capacity 40litres
Capacity 150litres
Supply only over load protector device No. 12420 for 40/150litres capacity water coolers
Supply only starting relay open type/box type suitable for 40litres (No. 82010167) capacity water coolers
Supply only starting relay open type/box type suitable for 150litres (No.1062) capacity water coolers
Supply only starting capacitor 80-100MFD for 150litres water cooler
Supply only running capacitor 10MFD for 40litres water Cooler
Supply only running capacitor 36MFD for 150litres water cooler
Supply only drain hose pipe 40mm bore
Supply only condenser plastic fan blade for fan motor 1/10/ to 1/16HP,1/32,1/35
Supply only self-closing push taps for water coolers of capacity 150/40litres
S&F company made new sealed compressor units including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed for the following capacities of water coolers: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
Capacity 40litres
Capacity 150litres
S&F condensor fan motor of capacity 1/10, 1/16HP, single phase AC 220V suitable for water coolers of capacity 150litres including disconnecting the electric mains and taking out and disposing off the unserviceable fan motor and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
S&F condensor fan motor of capacity 1/32HP, single phase AC 220V suitable for water coolers of capacity 40litres including disconnecting the electric mains and taking out and disposing off the unserviceable fan motor and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
S&F condenser coil fins suitable for water coolers of capacity 150litres including disconnecitng the mains and taking out and disposing off unserviceable condenser coil fins complete all as specified and as directed
S&F condenser coil fins suitable for water coolers of capacity 40litres including disconnecitng the mains and taking out and disposing off unserviceable condenser coil fins complete all as specified and as directed
S&F evaporator / cooling coils as per existing pattern suitable for water coolers including disconnecting the electric mains and taking out and disposing off the unserviceable fan motor and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
M&L for base for water coolers made out of MS sheet and angle iron for 40/150litres capacity including cutting the rusted unserviceable base as per required size and shape including all welding, etc. complete all as specified and as directed
M&L for charging refrigerant gas R-22/R-134A in water coolers of capacity 40/150litres including required staging / taking down of compressor units, etc. as required and testing on commissioning in satisfactory working conditions complete all as specified and as directed
M&L for dismantling water coolers 40/150litres capacity, taking out the copper tank, brazing and welding, etc. to check leakages in tank and refixing and connecting up nuts bolts, rubber washers, etc. including inserting glass wool, tarpaulin sheet and refixing unit, testing and commissioning complete all as specified and as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to water coolers of 40/150litres capacity with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide primer complete all as specified all as directed
M&L for tracing out leakages in water coolers of capacity 40 to 150litres in any section, condensor coil, evaporator coil and rectifying the same by copper brazing, changing the capillary filter, pressure testing the complete circuit, vacuum the circuit and charging the refrigerant to required pressue and commissioning complete all as specified all as directed Note: Refrigerant R-22/R-134A will be measured and paid separately under respective item herein
M&L for taking out water cooler tanks from water coolers of capacity 40 to 150litres capacity and repairing the tank with brazing, welding, etc. as required to stop leakages including inserting glass wool, tarpaulin sheet, etc. and re-installing in original position including testing and commissioning complete all as specified and as directed
M&L for sheet steel repair works to body of water coolers including replacement of rusted nut bolts & screws, including applying two coats of synthetic enamel paint (tint as approved) by spray gun over a coat of red oxide primer entirely over MS body parts complete all as specified and as directed of the following capacities:
Capacity 40litres
Capacity 150litres
S&F top door made out of stainless steel 20 gauge sheet, with handle and locking arrangement with double keys, door gasket and recommended insulation material and PVC inner sheet of suitable thickness, as per eixsiting size and shape, including welding works, nuts, bolts & washers as required complete all as specified and as directed for the following capacities of water coolers:
Capacity 40litres
Capacity 150litres
S&F in repairs PVC connections 15mm bore with PTMT nuts, of length 900mm complete all as specified and as directed
S&F in repairs 15mm dia stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed
S&F steel water tubing, 15mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors required for connections including taking up/down old unserviceable tubings and disposing off complete all as specified and as directed
M&L for disconnecting from mains and taking down for repair / servicing of refrigerator / deep freezer of capacity 165 to 310litres including labour for detecting the leakage of gas, repairing leakage and recharging refrigerant, cleaning of cooling coil, condenser, compressors, with vacuum cleaner and cleaning solution, checking servicibility of electrical / electronic circuits relays, wiring kit, thermostat switches, knobs, etc. and keeping the units in satisfactory working conditions complete all as specified and as directed Note: Spares / parts / componenets/ refrigerant gas will be measured and paid separately under relevant items hereinafter and labour charges for replacement shall be deemed to be included in this unit rate quoted
Supply only thermostat switch with knob
Supply only starting relay 1/8HP to 1/6HP open type with OLP
Supply only copper filter, single capillary, pencil type
Supply only vegetable tray / defrost tray / ice tray /bottle shelve/ water tray /chiller tray of PVC for 165 to 310litres capacity freezers / refrigerators of original make and type
Supply only freezer door PVC for 165/180/280/300/310litres capacity refrigerators / freezers of existing make, type, design and size
Supply only door switch for refrigerator 165 to 310litres
Supply only interior light fittings with bulb for refrigerators
Supply only suitable door handles of approved design and type for refrigerators
Supply only suitable refrigerator compartment glass of existing thinkness with PVC / plastic beading all round, of approved design and type
S&F company made new sealed compressor units for refrigerators including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed for the following capacities: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
Capacity 165 to 180litres
Capcity 210/280/300/310litres
S&F in repairs evaporator / freezer made out of aluminium pressed type of capacity 165 to 310litres capacity with freezer frame and door including connecting up complete all as specified and as directed
Supply of refrigerant gas any type i.e. R-22/R-134A/R-302, etc. in standard can cartrage for recharging refrigerator complete all as specified and as directed
Supply only capacitor 4MFD
Supply only wood wool cooler pads (set of three) 70cm long having weight of 500gm each set
Supply only MS / plastic front grill as per exisitng size and type
Supply only PVC pipe 1/2" with plastic elbow as per exisiting length (set of three)
Supply only PVC distirbutor box of existing or suitable size
Supply only Plastic / aluminium fan blades for cooler motor fan
Supply only wooden ply of size 6mm thick and sheet size 900x1800mm water proof for desert cooler fixing of desert cooler/window AC
Supply only plug top 3pin 15A
Supply only PVC insulated and overall PVC sheathed copper cable 1.5sqmm 3 core
S&F cooler fan motor 1/10HP capacity single speed, single phase, 240V, including taking down unserviceable fan motor by disconnecting mains, reconnecting electric mains and testing on completion complete all as specified and as directed
S&F water lifting pump, heavy duty, of existing capacity, single phase 240volts by disconnecting the mains, taking out, replacing the existing unserviceable pump and disposing off, reconneting electric mains and testing on completion complete all as specified and as directed
S&F stands for desert cooler/window ACs, etc. made out of angle iron 40x40x5mm of required size with four legs including leg supports duly painted with two coats of synthetic enamel paint (tint as approved) over one coat of red oxide primer including taking out unserviceable or rusted angle iron stands and disposing off complete all as specified and as directed
S&F side panels fabricated out of MS sheets of 6mm thick or of existing thickness with and including Khus Khus pad set of size 70x70cms having weight 500gms each set for desert coolers including all bolting, screwing, etc. as required complete all as specified and as directed
M&L for preparation of surfaces of desert cooler by scrapping old paint with sand paper, cleaning inner and outer surfaces of body and spray painting the inner surfaces and grills with two coats of black anticorrosive paint and outer surfaces with two coats of alluminium paint, over one coat of zinc chrome primer complete all as specified and as directed
M&L for replacement of outdoor condensor fan with condenser coil unit of upto 7.5TR capacity and existing make complete all as specified and as directed
M&L for replacement of condensor fan 3 phase 415V of air modular unit with condenser coil unit of upto 12.5TR capacity and existing make complete all as specified and as directed
Supplying, topping up, filling of compressor oil (non-freezing) of viscocity 68 in AC plant at any locations / positions complete all as specified and as directed
S&F FRP side panel (set of four) for circular type cooling tower capacity upto 60TR including fins, fan motor, fan blade and sprinkler complete all as specified and as directed
S&F FRP side panel (set of four) for circular type cooling tower capacity upto 100TR including fins, fan motor, fan blade and sprinkler complete all as specified and as directed
M&L for installing in position scroll type compressor capacity 12.5Ton, of existing make and type, commissioning and including all tests on installation complete all as specified and as directed Notes: (i) Work shall be done by authorised rep of OEM or authorised service centres of equipment manufacturer (ii) The unit shall bear guarantee of manufacturer minimum of 5yrs from date of commissioning (iii) Al cartage, loading, unloading, etc. all as required at site shall be deemed to be included in the quoted rate
Supplying, hoisting, fixing and connecting up rotational moulded polythylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. and diposing off old damaged tank complete all as specified and as directed of the following capacities:
5000litres
2000litres
M&L for fabrication iron works using channel/angle/flats/plates including all cutting / welding /grinding, etc. for cooler stands, etc. and similar works complete all as specified and as directed
M&L for rewinding of electric motor of capacity 3 phase operating on 50Hz 415V comprising of the underlaid activities complete all as specified and as directed for the following capacities: (a) Disconnecting & removing the electric motor from AHU/booster from the installed position and loading / unloading transporting to contractor’s workshop for repairs (b) Dismantling existing burnt winding from the motor, preparing for rewinding complete with super enamelled copper winding wire of existing gauge including all insulating materials such as insulation paper, sleeves, tape, varnish, etc. and painting with two coats of super enamel paint over a coat of primer and greasing of bearings (c) Loading/unloading/transporting motor to the site, installing in position, checking and confirming alignment, electric connection, commissioning and testing in actual working conditions for 8hours continuously (d) Motors shall be handed over during the currency of contract on as and when required basis. Each motor shall be returned duly repaired within 10days from the date of handing over. Date of commencement of guarantee period of 2year shall commence from the date of testing & successful taking over by the Department when installed after repairs
1HP 1400RPM
2HP 1440RPM
5HP 1440RPM
S&F thermal expansion valves suitable for 11TR of existing make and model complete all as specified and as directed
S&F MCB TP 415V, 63A 10kA complete all as specified and as directed
S&F MCB TP 415V, 40A 10kA complete all as specified and as directed
S&F MCB TP 415V, 32A 10kA complete all as specified and as directed
S&F set of indicator bulbs Red, Blue and Green for phases, ISI marked complete all as specified and as directed
S&F rotary switch 5A Red, Blue and Green for phases ISI marked complete all as specified and as directed
S&F On / Off switch to start / stop for AHU motors (set of two) complete all as specified and as directed
S&F flair nut 5/8" complete all as specified and as directed
S&F flair nut 3/4" complete all as specified and as directed
S&F flair nut 1/2" complete all as specified and as directed
S&F flair nut 1/4" complete all as specified and as directed
S&F V type fan belt bearing as per existing size and make complete all as specified and as directed
S&F sprinkler PVC for cooling tower of different capacity of existing make complete all as specified and as directed
S&F tie rod with strainer and clamp for cooling tower of existing aluminium distribution 120mm link as per existing make complete all as specified and as directed
S&F aluminium distributor hub for standard bore pipe as per existing make and type complete all as specified and as directed
S&F PVC distribution pipe 80mm of existing length with HDPE flapper as per existing make and type complete all as specified and as directed
M&L for repairs and general servicing of three phase servo voltage stablizer including dismantling of AVR from AC plants, disconnection from AC supply, draining of transformer oil, lifting of AVR from oil tank with the help of chain pulley block and tripod and checking of any fault in the AVR assembly, replacing defective parts/spares as reqquired viz. electronic control card for voltage regulation, carbon brushes, indicator, RC network, micro-switch, voltmeters, rubber gasket and packing, oven baking of series transformers including re-varnishing & re-taping, series transformer coil, cleaning of all contacts, tightening of all nuts and bolts, thimbles, all inter-connections, making adjustment of electronic control circuits, indicators, output adjustment potentiometer, voltmeter, etc. filling and top up of transformer oil after dehyderation and filltering of old and used transformer oil at site and testing of AVR for satisfactory operation and testing on completion complete all as specified and as directed for the following voltage stabilisers: Notes: (i) Payment of new parts/ components against defective parts / component shall be made seperately as 'supply only' under relevant items and labour charges for fixing of new spares parts shall deemed to be included in the quoted rates (ii) Carting to workshop including all loading / unloading, etc. shall be deemed to be inclusive in the quoted rate
Supply only carbon brushes of existing type and make complete all as specified
Supply only electronic control card for voltage regulation of existing type and make complete all as specified
Supply only auto variable transformer coils of existing type and make complete all as specified
Supply only indicator bulbs Red, Blue and Green for phases ISI marked complete all as specified
Supply only rubber gaskets & packings of existing type and make complete all as specified
Supply only servo motors as per existing make, type and capacity complete all as specified
Supplying and re-charging of refrigerant gas R-22 in central/package type AC plant including detection of leakage if any and rectification of same in the system by using carbon di-oxide gas and flushing the entire system throughly with nitrogen gas complete all as specified and as directed
Supplying and re-charging of refrigerant gas R-134/407 in central/package type AC plant including detection of leakage if any and rectification of same in the system by using carbon di-oxide gas and flushing the entire system throughly with nitrogen gas complete all as specified and as directed
Notes for serial item Nos. 179 & 180: (i) Refrigerant shall be brought at site from authorised dealer/ manufacturer in company's sealed cyclinders of standard packings with requisite test certificates and PVs (ii) Re-filling shall be done in the presence of rep of Dept. The empty cylinders after using the gas brought shall be returned to the Contractor & for payment purppose, only gas to the required extent used for charging shall be considered (iii) The unit rate quoted is inclusive of cost of nitrozen gas & CO2 gas required for leakage test to pressure test
M&L for electric motor of capacity 10HP, 3 phase, 50Hz, 415V, 1440RPM including disconnecting and dismantling of old electric motor of cooling tower/sewage pump/diaphram doser installed at any position, cutting of the burnt copper coil, cleaning of stator, rewinding with and including super enamelled copper conductor wire of sutable size & guage (as per existing), servicing with provision of insulation paper, packing, threads, sleeves, etc. dry machining, welding, cleaning, greasing of bearings, etc. recomissioning and testing on full load complete all as specified and as directed
Notes for item No. 182: (i) Quoted rates shall also be deemed to be inclusive of loading, unloading, transporting of motor/pump sets, installing in position, setting alignment, making electric connections, commissioning and testing for 8hour continuously in actual working conditions (ii) Motors shall be handed over during the currency of Contract on as and when required basis (iii) Each motor shall be returned duly repaired within 10days from the date of handing over to the contractor for re-winding and repairs (iv) Guarantee period of two years shall commence from the date of testing & successful taking over by the Department
Radhe Krishn Engineering
Star Electricals Udyog
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .